Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "ion exchanger" wg kryterium: Temat


Wyświetlanie 1-10 z 10
Tytuł:
Recovery of crystalline glucose from the last green syrup (so called hydrol)
Odzyskiwanie krystalicznej glukozy z ostatniego odcieku tzw. hydrolu
Autorzy:
Nebesny, E.
Sroczyński, A.
Powiązania:
https://bibliotekanauki.pl/articles/1399007.pdf
Data publikacji:
1987
Wydawca:
Instytut Rozrodu Zwierząt i Badań Żywności Polskiej Akademii Nauk w Olsztynie
Tematy:
improvement of hydro!
glucose
glucoamylase ion exchanger
Opis:
Hydrol was refined and saccharified enzymatically, following which its glucose was crystallized directly or in a mixture with starch hydrolysate.
W przeprowadzonych doświadczeniach, ostatni odciek po krystalizacji glukozy tzw. hydrol o wartości 64 DE, stanowiący produkt uboczny hydrolizy skrobi metodą kwas-enzym poddawano rafinacji wymieniaczami jonowymi (kationitem i anionitem) oraz żywicą adsorpcyjną w celu usunięcia zanieczyszczeń mineralnych i organicznych (tab. 1), w tym głównie białka surowego. Następnie oczyszczony hydrol scukrzono glukoamylazą (0,25%s. s.) w temp. 60°C przy pH 4,5 w ciągu kilku dni (tab. 2). Jednocześnie scukrzano glukoamylazą hydrolizat skrobi o ok. 22 DE po wstępnej kwasowej hydrolizie i mieszaninę hydrolu rafinowanego i hydrolizatu w stosunku 1: 4. Uzyskano znaczne scukrzenie hydrolu rafinowanego do wartości 86 DE, równającej się redukcyjności soku glukozowego produktu II. Scukrzanie glukoamylazą mieszaniny hydrolu i hydrolizatu pozwoliło osiągnąć redukcyjność 92,8 DE zbliżoną do wartości 94,4 DE soku glukozowego produktu I (samego hydrolizatu). Przeprowadzona analiza składu węglowodanowego hydrolu surowego i hydrolu rafinowanego po jego scukrzeniu glukoamylazą pozwoliła stwierdzić podwyższenie prawie 1,5-krotne zawartości glukozy i obniżenie do około połowy zawartości izomaltozy i izomaltotriozy w s. s. hydrolu oraz praktycznie zanik pozostałych oligosacharydów rj. maltozy i jej wyższych homologów. Po zagęszczeniu wymienionych roztworów, scukrzonych glukoamylazą, do ok. 72 Bx i zaszczepieniu ich 1,25% monohydratu glukozy krystalicznej, przeprowadzono w ciągu 2-4 dni w temperaturze stopniowo obniżanej z 44°C krystalizację w nich glukozy. W wyniku tego procesu uzyskano 36,2% glukozy krystalicznej (w przeliczeniu na bezwodną) z hydrolu rafinowanego scukrzonego a nawet 42,4% wykrystalizowanej glukozy z mieszaniny hydrolu i hydrolizatu skrobi (1 : 4) to jest ilość zbliżoną do glukozy wykrystalizowanej z czystego hydrolizatu skrobi- 44,1%, co jest dobrym rezultatem. Powyższe wyniki mają istotne znaczenie z uwagi na kilkakrotnie wyższą cenę glukozy krystalicznej niż glukozy zawartej w hydrolu.
Źródło:
Acta Alimentaria Polonica; 1987, 13, 4; 342-349
0137-1495
Pojawia się w:
Acta Alimentaria Polonica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Multifunctional Coagulants Based on Hidrocarboaluminates Calcium
Autorzy:
Sizyakova, E. V.
Ivanov, P. V.
Powiązania:
https://bibliotekanauki.pl/articles/124466.pdf
Data publikacji:
2017
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
hidrocarboaluminates calcium
water treatment
coagulant
ion exchanger
Opis:
The article describes harmful factors from the environmental point of view that accompany almost all stages of the production of non-ferrous metals. Due to the fact that this industry requires large volume of water, these factors require special attention when cleaning wastewater. The contamination of wastewater by non-ferrous metallurgy is characterized by metal ions, particulate pollutants, acids, SAS, etc. A common feature of all these substances is harmfulness, however, they are often very aggressive and toxic. The article focuses on the possible use of hidrocarboaluminates calcium as an active ion exchanger for cleanup wastewater metallurgical production.
Źródło:
Journal of Ecological Engineering; 2017, 18, 2; 16-20
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zinc(II) removal from model chloride and chloride–nitrate(V) solutions using various sorbents
Autorzy:
Wołowicz, Anna
Powiązania:
https://bibliotekanauki.pl/articles/109382.pdf
Data publikacji:
2019
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
heavy metals
zinc
removal
ion exchanger
Lewatit MonoPlus TP220
Opis:
Zinc(II) complexes removal from aqueous chloride and chloride-nitrate(V) solutions was realized using different type of sorbents such as an ion exchangers of the chelating type (Lewatit MonoPlus TP220, Purolite S984), strongly basic (Lewatit MonoPlus SR7, Purolite A400TL, Dowex PSR2, Dowex PSR3) and weakly basic (Purolite A830) anion exchangers as well as the adsorbent resin Lewatit AF5. The kinetic and equilibrium studies using the static method were carried out in order to examine the rate of zinc(II) removal as well as to obtain the maximum adsorption capacities. The obtained experimental data were analyzed by means of different kinetic and isotherm models as well as the corresponding parameters were calculated. The desorption and reuse studies (three cycles of sorption/desorption) were also discussed. Lewatit MonoPlus TP220 showed the highest efficiency of zinc(II) removal and the maximum sorption capacity was equal to 620 mg/g. The kinetics of zinc(II) sorption is well described by the pseudo-second order kinetic model. The interactions between the sorbent and zinc ions are strong because no quantitative zinc desorption was observed (40% using nitric(V) and sulfuric(VI) acids for Lewatit MonoPlus TP220).
Źródło:
Physicochemical Problems of Mineral Processing; 2019, 55, 6; 1517-1534
1643-1049
2084-4735
Pojawia się w:
Physicochemical Problems of Mineral Processing
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Cooper removal and recovery from aqueous solutions by using selected synthetic ion exchange resins (part I)
Usuwanie i odzysk miedzi z roztworów wodnych przy użyciu wybranych syntetycznych żywic jonowymiennych (część I)
Autorzy:
Orlof-Naturalna, Monika
Bożęcka, Agnieszka
Powiązania:
https://bibliotekanauki.pl/articles/1841489.pdf
Data publikacji:
2020
Wydawca:
Polskie Towarzystwo Przeróbki Kopalin
Tematy:
copper ions
ion exchange
ion exchanger resins
microstructural research
jony miedzi
wymiana jonowa
jonity
badania mikrostrukturalne
Opis:
The paper presents results of research on removal of Cu2+ ions from aqueous solutions by ion exchange method in concentration range of 10–1000 mg/L. For this purpose, following Purolite synthetic ion exchange resins were used: S 910, S 930, S 940, S 950 and C 160. The obtained results were interpreted based on the degree of solution purification and microstructural investigations. The regeneration possibility of used ion exchangers with a 10% hydrochloric acid solution was also investigated. Based on obtained results, it was determined that studied ion exchangers efficiently removed copper(II) ions from aqueous solutions, especially in low concentrations. Microstructural investigation made for tested materials after the sorption process clearly indicate that Cu2+ ions removal process was in accordance with ion exchange mechanism, which was confirmed by recorded SEM images. All ion exchangers except S 910, purified solutions from Cu2+ ions with an efficiency greater than 90% up to a concentration of 100 mg/L. In case of S 930 and S 940 ion exchangers, their efficiency was close to 100%. For higher concentrations, efficiency of studied ion exchangers decreased significantly. The lowest decrease in degree of copper(II) S 910 chelating resin with amidoxime groups was the least efficient. All studied ion exchangers can be regenerated with a 10% hydrochloric acid solution. The efficiency of this process varies from 53.1% to 80.5% depending on the used resins.
W pracy przedstawiono wyniki badań dotyczące usuwania jonów Cu2+ z roztworów wodnych metodą wymiany jonowej w zakresie stężeń 10–1000 mg/L. W tym celu zastosowano żywice jonowymienne firmy Purolite: S 910, S 930, S 940, S 950 i C 160. Otrzymane wyniki zinterpretowano w oparciu o stopień oczyszczenia roztworu i badania mikrostrukturalne. Zbadano również możliwość rege¬neracji użytych jonitów za pomocą 10% roztworu kwasu solnego. Na podstawie otrzymanych wyników stwierdzono, że badane jonity skutecznie usuwały jony miedzi(II) z roztworów wodnych, szcze¬gólnie w niskich stężeniach. Badania mikrostrukturalne wykonane dla badanych materiałów po procesie sorpcji wyraźnie wskazują, że proces usuwania jonów Cu2+ zachodził zgodnie z mechanizmem wymiany jonowej, co potwierdzają zarejestrowane obrazy SEM. Na powierzchni badanych jonitów nie zaobserwowano mikrostrąceń. Wszystkie wymieniacze jonowe z wyjątkiem S 910 oczyszczały roztwory z jonów Cu2+ z wydajnością większą niż 90% do stężenia 100 mg/L. W przypadku jonitów S 930 i S 940 ich skuteczność było bliska 100%. W przypadku większych stężeń wydajność badanych jonitów znacząco malała. Najmniejszy spadek stopnia wydzielenia jonów miedzi(II) zaobserwowano dla kationitu C 160 zawierają¬cego grupy sulfonowe. Najmniej skuteczny okazał się jonit chelatujący S 910 z grupami amidoksymowymi. Wszystkie badane jonity można regenerować za pomocą 10% roztworu kwasu solnego. Wydajność tego procesu waha się od 53,1% do 80,5% w zależności od użytej żywicy jonowymiennej.
Źródło:
Inżynieria Mineralna; 2020, 2, 2; 7-14
1640-4920
Pojawia się w:
Inżynieria Mineralna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ układu oczyszczania wody na zakres stosowalności procesu MIEX®DOC
The effect of the water treatment train on the range of applicability for the MIEX®DOC process
Autorzy:
Mołczan, M.
Karpińska, A.
Powiązania:
https://bibliotekanauki.pl/articles/236894.pdf
Data publikacji:
2007
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
oczyszczanie wody
wymiana jonowa
żywica MIEX
koagulacja
ozonowanie
water treatment
ion exchanger
MIEX® resin
ozonation
Opis:
Analiza położenia zakresu stosowalności procesu MIEX®DOC miała na celu wskazanie racjonalnych wartości podstawowych parametrów tego procesu, tj. dawki żywicy i czasu kontaktu. Wykazano, że zakres ten ograniczony jest skrajnymi wartościami iloczynu dawki żywicy i czasu kontaktu (FPmin; FPmaks), określonymi na podstawie badania przebiegu krzywej kinetycznej. Położenie zakresu stosowalności określono badając wodę powierzchniową ujmowaną do zaopatrzenia Wrocławia, oczyszczaną w układzie technologicznym składającym się z koagulacji, filtracji (sand filtration), ozonowania pośredniego, filtracji przez złoże węglowe (GAC) i dezynfekcji. W badaniach nie stwierdzono wyraźnie powtarzalnych relacji w przebiegach krzywych kinetycznych procesu stosowanego w różnych miejscach układu technologicznego. Wyraźna była natomiast tendencja do obniżania wartości dolnej granicy zakresu stosowalności po kolejnych procesach oczyszczania, z wyjątkiem wody po filtracji przez złoże węgla aktywnego. Podobna tendencja w odniesieniu do górnej granicy zakresu stosowalności była znacznie mniej powtarzalna. Wykazano, że wraz z postępującym stopniem oczyszczenia wody zakres stosowalności procesu MIEX®DOC ulegał zawężeniu oraz nieznacznemu przesunięciu w kierunku niższych wartości iloczynu dawki żywicy i czasu kontaktu. W konsekwencji można wnioskować, że lokowanie procesu wymiany anionowej po kolejnych procesach oczyszczania wody będzie wiązało się z malejącymi nakładami na jego realizację. Biorąc jednak pod uwagę znacznie szybciej malejące ładunki usuwanych zanieczyszczeń, nakłady jednostkowe będą wzrastały.
The position of the range of applicability for the MIEX®DOC process was analyzed in order to indicate the rational values for the basic parameters of the process (resin dosage, contact time). The applicability range was found to be limited by the extreme values of the product of resin dosage and contact time (FPmin; Fpmax) defined from the plot of the kinetic curve. The position of the applicability range was determined by analyzing samples of surface water (taken in for municipal supply to the city of Wroclaw) treated via a treatment train involving coagulation, sand filtration, direct ozonation, GAC filtration and disinfection. The study revealed no apparently repeatable relations in the plots of the kinetic curves for the process applied at various points of the treatment train. However, the lower limit values of the applicability range showed a tendency to decrease after successive unit processes (except after GAC filtration). As for the upper limit values of the applicability range, this tendency was less repeatable. It was demonstrated that as the efficiency of the treatment process increased, the applicability range for the MIEX®DOC process became narrower, and there was a slight shift towards the lower values of the product of resin dosage and contact time. Hence, it can be concluded that the location of the anion exchange process after successive unit processes will involve decreasing operating expenses. But taking into account the decrease in the quantity of the organics removed (which proceeds at a much faster rate), unit expenses will tend to increase.
Źródło:
Ochrona Środowiska; 2007, R. 29, nr 1, 1; 11-17
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Opis i interpretacja wyników testu kinetycznego procesu MIEX®DOC
Kinetic jar test of the MIEX®DOC process: Description and interpretation of results
Autorzy:
Mołczan, M.
Powiązania:
https://bibliotekanauki.pl/articles/1203875.pdf
Data publikacji:
2007
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
oczyszczanie wody
wymiana jonowa
substancje organiczne
żywica MIEX
test kinetyczny
water treatment
organics removal
ion exchanger
MIEX® resin
resin dosage
kinetic jar test
Opis:
Proces MIEX®DOC, stosowany do usuwania zanieczyszczeń organicznych z wody przy pomocy wymiany anionowej, opisują parametry procesowe, do których zalicza się czas kontaktu wody z żywicą anionowymienną, dawkę żywicy oraz krotność wymiany objętości żywicy. Dawka i czas kontaktu są parametrami kinetyki reakcji wymiany i są wspólnie badane w teście naczyniowym określanym mianem testu kinetycznego. Wynikiem testu kinetycznego procesu MIEX®DOC jest zależność pozostałej zawartości usuwanego substratu (ce) od czasu kontaktu (t) i dawki żywicy (d). Metodyczna analiza uzyskanego wyniku wymaga zapisania go w postaci zależności funkcyjnej, która dobrze aproksymuje punkty doświadczalne, a jej współczynniki mają sens fizyczny istotny z punktu widzenia interpretacji wyniku.
The MIEX®DOC process (which aims at removing organic pollutants from water via anion exchange) is described by the following parameters: time of contact between water and anion-exchange resin, resin dosage and bed volumes of resin volume exchange. Since resin dosage and contact time are parameters of the kinetics of the exchange reaction, they are examined using the kinetic jar test. The result of the kinetic jar test for the MIEX®DOC process is a formula that relates the persisting portion of the substrate to be removed (ce) to contact time (t) and resin dosage (d). A prerequisite for the analysis of the result obtained states that the result should be written in the form of a functional relationship which well approximates the experimental points and that the coefficients of the relationship should have a physical meaning which is of significance to the interpretation of the result.
Źródło:
Ochrona Środowiska; 2007, R. 29, nr 1, 1; 45-48
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ procesu wymiany anionowej na zmianę jakości domieszek organicznych wody charakteryzowanych wartościami absorbancji właściwej (SUVA) i barwy właściwej (SCOA)
Effect of the anion exchange process on the change in the quality of organic water pollutants characterized by the specific UV absorbance (SUVA) and specific colour absorbance (SCOA) values
Autorzy:
Mołczan, M.
Powiązania:
https://bibliotekanauki.pl/articles/236935.pdf
Data publikacji:
2007
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
oczyszczanie wody
wymiana anionowa
żywica MIEX
absorbancja właściwa
substancje organiczne
water treatment
organics removal
ion exchanger
MIEX® resin
specific UV absorbance
specific colour absorbance
Opis:
Zarówno barwa, jak i absorbancja w nadfiolecie charakteryzują jakość obecnych w wodzie substancji organicznych. Absorbancja właściwa (SUVA - Specific UV Absorbance) oraz barwa właściwa (SCOA - Specific Colour Absorbance) opisują zagęszczenie cech substancji organicznych związanych z ich potencjalną reaktywnością (SUVA) oraz zdolnością do nadawania wodzie zabarwienia (SCOA). Wartości tych wskaźników pozwalają na ocenę selektywności procesów oczyszczania wody pod kątem usuwania organicznych zanieczyszczeń barwnych (których zawartość jest ograniczona) oraz reaktywnych (których zawartość jest ograniczona pośrednio, np. ubocznych produktów dezynfekcji, środka dezynfekcyjnego itp.). Procesem zdolnym do selektywnego usuwania substancji organicznych cechujących się dużymi wartościami absorbancji w UV oraz barwy właściwej jest wymiana anionowa na namagnetyzowanych żywicach drobnoziarnistych MIEX® . Wykazano, że składniki usuwane z wody w procesie wymiany anionowej wykazują wartość absorbancji właściwej oraz barwy właściwej odpowiednio o 6悝% oraz 5悛% wyższą od wartości charakteryzujących wodę surową. Wodę oczyszczoną cechują natomiast wartości tych wskaźników odpowiednio o 14悯% oraz 12悹% niższe niż w wypadku wody surowej. Stwierdzono, że proces wymiany anionowej może potencjalnie dać podobną skuteczność zmniejszenia wartości SUVA, jaki jest osiągany w całym ciągu technologicznym oczyszczania wody, złożonym z koagulacji, filtracji pospiesznej, ozonowania i biosorpcji.
The quality of the organic substances that are present in the water is characterized both by colour and UV absorbance. Specific UV Absorbance (SUVA) and Specific Colour Absorbance (SCOA) describe the density of the organic matter properties that are indicative of the potential reactivity (SUVA) and capability of the organic substance to colour the water (SCOA). Knowing the values of SUVA and SCOA enables the selectivity of the water treatment process to be assessed with respect to the removal of organic coloured matter (whose content is limited) and reactive substances (whose content is indirectly limited, e.g. by the by-products of disinfection, by disinfectant dosage, etc.). When the organics to be removed are characterized by high SUVA and SCOA values, anion exchange over magnetized fine-grained MIEX® resins is the treatment mode that provides a selective removal of such organic substances. The experiments have revealed the following: the organic pollutants being removed via anion exchange display SUVA and SCOA values that are by 6 to 33% and 5 to 31%, respectively, higher than those characterizing raw water; the SUVA and SCOA values of treated water are by 14 to 51% and 12 to 61% lower than those of raw water. The study has substantiated the potentiality of anion exchange for providing a reduction in the SUVA value similar to the one achieved by the entire water treatment train involving coagulation, rapid filtration, ozonation and biosorption.
Źródło:
Ochrona Środowiska; 2007, R. 29, nr 2, 2; 13-19
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Treatment of Wastewater Containing a Mixture of Heavy Metal Ions (Copper-Zinc, Copper-Nickel) using Ion-Exchange Methods
Autorzy:
Koliehova, Anastasiia
Trokhymenko, Hanna
Melnychuk, Svitlana
Gomelya, Mykola
Powiązania:
https://bibliotekanauki.pl/articles/125436.pdf
Data publikacji:
2019
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
heavy metals
ion exchange
regeneration
cation exchanger
sorption
Opis:
The main aim of the scientific research was to study the ion-exchange processes in the treatment of industrial wastewaters containing a high concentration of heavy metal ions (Cu2+, Zn2+, Ni2+). The sorption results of heavy metal mixtures (Cu-Zn, Cu-Ni) from model solutions of sulfate salts on a strong-acid KU-2–8 cation exchanger in the H+-form were presented. The metals concentration was 10–50 meq/dm3. The efficiency conditions of cation regeneration in Cu2+-Zn2+, Cu2+-Ni2+-forms by 5, 8 and 10 % sulfuric acid solutions were studied. It was shown that the heavy metals from aqueous media can be removed not only from ion exchangers, but can also be restored from regenerative solutions by electrolysis to obtain metals in pure form. In general, the research results showed that the use of ion exchange is very effective in removing the heavy metal ions. The sorption efficiency and regeneration efficiency was about 100%.
Źródło:
Journal of Ecological Engineering; 2019, 20, 11; 146-151
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Demineralizacja wody naturalnej za pomocą wymieniaczy jonowych
Demineralization of natura! water with use of ions exchangers
Autorzy:
Łach, A.
Powiązania:
https://bibliotekanauki.pl/articles/106504.pdf
Data publikacji:
2011
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
wskaźniki jakości wody
oznaczenia analityczne wskaźników
wymieniacze jonowe
demineralizacja wody
reakcje regeneracji jonitów
kationit wodorowy
anionit wodorotlenowy
indicators of quality of water
analytical symbols of indicators
ion exchangers
demineralization of water
reactions of ions exchangers regeneration
hydrogen cation exchanger
hydroxyl anion exchanger
Opis:
W artykule scharakteryzowano pięć wskaźników jakości wody naturalnej oraz przedstawiono przepisy analityczne ich oznaczania. W rezultacie, badając poziom wybranych wskaźników jakości wody, możemy określić efektywność demineralizacji wody naturalnej za pomocą wymieniaczy jonowych. Wymieniaczami jonowymi użytymi w doświadczeniach są: kationit wodorowy i anionit wodorotlenowy. Dodatkowo uwzględniono przykładowe reakcje chemiczne zachodzące na jonitach zarówno w trakcie procesu demineralizacji, jak i ich regeneracji. Badania laboratoryjne przedstawiają prace wymieniaczy jonowych ze szczególnym uwzględnieniem demineralizacji wody naturalnej.
The article contains information on five indicators of natura! water quality. The effectiveness of natural water demineralization by using ions exchangers was shown. The representatives of ions exchangers used in the experiments are hydrogen cation and hydroxyl anion. The article contains technical parameters of these ions exchangers. Additionally, some chemical reactions which take place in ions exchangers during demineralization and regeneration process are also presented.
Źródło:
Chemistry-Didactics-Ecology-Metrology; 2011, 16, 1-2; 97-101
2084-4506
Pojawia się w:
Chemistry-Didactics-Ecology-Metrology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowanie Amberlitu IRA-400 do rozdzielania wapnia i fosforu w produktach spożywczych pochodzenia roslinnego
Primenenie Amberlita IRA-400 pri razdelenii kal'cija i fosfora v pishhevykh produktakh rastitel'nogo proiskhozhdenija
Amberlite IRA-400 used for separation of calcium and phosphorus in food products of plant origin
Autorzy:
Chojnicka, B.
Powiązania:
https://bibliotekanauki.pl/articles/871537.pdf
Data publikacji:
1962
Wydawca:
Narodowy Instytut Zdrowia Publicznego. Państwowy Zakład Higieny
Tematy:
produkty spozywcze
zywnosc pochodzenia roslinnego
wapn
fosfor
oznaczanie
wymiana jonowa
anionity
Amberlit IRA-400
fotometry plomieniowe
food product
plant food
calcium
phosphorus
determination
ion exchange
anion exchanger
Amberlite IRA-400
flame photometry
Źródło:
Roczniki Państwowego Zakładu Higieny; 1962, 13, 3
0035-7715
Pojawia się w:
Roczniki Państwowego Zakładu Higieny
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-10 z 10

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies