Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "biological reactor" wg kryterium: Temat


Wyświetlanie 1-14 z 14
Tytuł:
Technical and economic aspects of industrial laundry wastewater treatment
Techniczne i ekonomiczne aspekty oczyszczania ścieków pralniczych
Autorzy:
Bering, S.
Mazur, J.
Tarnowski, K.
Powiązania:
https://bibliotekanauki.pl/articles/395838.pdf
Data publikacji:
2011
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
pralnia
ścieki pralnicze
biologiczne oczyszczanie ścieków
laundry
wastewater
membrane biological reactor
rotating biological contactor
sponge activated sludge reactor
Opis:
Three biological methods of laundry wastewater purification were tested, in pilot scale, in Fliegel Textilservice laundry in Nowe Czarnowo. Among tested methods, rotating biological contactor, membrane bioreactor and sponge activated sludge reactor, the last one has been pointed out as optimal for laundry wastewater treatment. Biological treatment of laundry wastewater, assisted by nitrogen addition, phosphorus chemical precipitation and neutralisation, generated purified wastewater with satisfactory quality. Case study of industrial laundry shows that total costs of wastewater utilization may be reduced by 39% and payback period of total investment costs is estimated at 7-8 years.
Wiele zakładów przemysłowych doświadcza problemu wysokich kosztów odprowadzania ścieków. Szczególnie dotyka to zakłady, w których prowadzone są procesy o wysokim zapotrzebowaniu na wodę. Jako alternatywę do odprowadzania surowych lub podczyszczonych ścieków, do komunalnych systemów kanalizacyjnych, należy rozważać budowę własnego systemu oczyszczania ścieków i ich zrzut do wód powierzchniowych. W przemysłowej pralni Fliegel Textilservice, w Nowym Czarnowie, przetestowano trzy metody biologicznego oczyszczania ścieków pralniczych. Wśród testowanych metod: biologiczne złoże obrotowe, bioreaktor membranowy i osad czynny utwierdzony na gąbkach, ostatnia z wymienionych wskazana została jako optymalna do oczyszczania ścieków pralniczych. Biologiczne oczyszczanie ścieków pralniczych, wspomagane dozowaniem azotu, chemicznym strącaniem fosforu i neutralizacją, generowało ścieki oczyszczone o satysfakcjonującej jakości. Analizowany przypadek wskazuje na możliwość redukcji kosztów gospodarki ściekowej o 39% oraz okres zwrotu nakładów inwestycyjnych rzędu 7-8 lat.
Źródło:
Civil and Environmental Engineering Reports; 2011, 7; 129-137
2080-5187
2450-8594
Pojawia się w:
Civil and Environmental Engineering Reports
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Warbud buduje "Czajkę"
Autorzy:
Ambroża-Urbanek, B.
Powiązania:
https://bibliotekanauki.pl/articles/364196.pdf
Data publikacji:
2010
Wydawca:
Nowoczesne Budownictwo Inżynieryjne
Tematy:
ekologia
inwestycje
oczyszczalnia ścieków Czajka
reaktor biologiczny
Warszawa
biological reactor
ecology
investment
Sewage-Treatment Plant Czajka
Warsaw
Opis:
Po latach protestów i przymiarek ruszyła wreszcie inwestycja rozbudowy i modernizacji Oczyszczalni Ścieków "Czajka". Ta największa inwestycja ekologiczna Warszawy, ma niebagatelne znaczenie nie tylko dla środowiska. Obok budowy Mostu Północnego i metra to inwestycja kluczowa dla funkcjonowania stolicy.
Źródło:
Nowoczesne Budownictwo Inżynieryjne; 2010, 3; 22-25
1734-6681
Pojawia się w:
Nowoczesne Budownictwo Inżynieryjne
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Budowa i modernizacja oczyszczalni Kujawy w Krakowie
Construction and modernization of Kujawy water treatment plant in Kraków
Autorzy:
Biedrzycka, A.
Powiązania:
https://bibliotekanauki.pl/articles/364223.pdf
Data publikacji:
2013
Wydawca:
Nowoczesne Budownictwo Inżynieryjne
Tematy:
oczyszczalnia ścieków
modernizacja
gospodarka wodno-ściekowa
reaktor biologiczny
wastewater treatment plant
modernization
water-sewage management
biological reactor
Opis:
Wodociągi Krakowskie rozbudowują oczyszczalnię ścieków Kujawy. Powstała w Nowej Hucie w latach 90. XX w., początkowo przede wszystkim z myślą o utylizacji ścieków fenolowych z kombinatu metalurgicznego, przyjmuje dziś ścieki bytowe nie tylko z terenu dzielnicy. Oczyszczalnia zostanie zmodernizowana, gdyż nie spełnia już unijnych wymagań ekologicznych. Inwestycja, określana jako budowa i modernizacja oczyszczalni Kujawy, musi zostać ukończona szybko z uwagi na konieczność dostosowania jakości ścieków do wymogów dyrektywy 91/271/EWG (tzw. dyrektywy ściekowej) do końca 2015 r.
Źródło:
Nowoczesne Budownictwo Inżynieryjne; 2013, 6; 38-41
1734-6681
Pojawia się w:
Nowoczesne Budownictwo Inżynieryjne
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
"Sitkówka" w fazie prób generalnych
Autorzy:
Gładyszowska-Dawid, M.
Powiązania:
https://bibliotekanauki.pl/articles/363968.pdf
Data publikacji:
2010
Wydawca:
Nowoczesne Budownictwo Inżynieryjne
Tematy:
ochrona środowiska
oczyszczalnia ścieków
oczyszczalnia ścieków Sitówka
reaktor biologiczny
biological reactor
environment protection
sewage treatment plant
sewage treatment plant Sitówka
Opis:
Nowy reaktor biologiczny w Oczyszczalni Ścieków .Sitkówka. rozmiarami dorównuje boisku piłkarskiemu, a każdy z czterech zbudowanych tu osadników wtórnych wielkością i kształtem przypomina mały stadion. Zarówno skala obiektów, jak i stopień skomplikowania technologicznego pokazują, jak wiele wysiłku wymaga oczyszczanie ścieków i ich przywrócenie obiegowi wody w przyrodzie. Patrząc na uruchomiony właśnie w ramach projektu Funduszu Spójności Rozbudowa i modernizacja Oczyszczalni Ścieków .Sitkówka. dla miasta Kielce pierwszy ciąg technologiczny oczyszczalni, widać gołym okiem, że warto...
Źródło:
Nowoczesne Budownictwo Inżynieryjne; 2010, 5; 48-50
1734-6681
Pojawia się w:
Nowoczesne Budownictwo Inżynieryjne
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowanie symulacji komputerowej procesu osadu czynnego do minimalizowania potencjału eutrofizującego ścieków oczyszczonych
Computer simulation of activated sludge process to obtain the minimum eutrophication potential of municipal wastewater
Autorzy:
Kowalewski, Z.
Neverova-Dziopak, E.
Preisner, M.
Powiązania:
https://bibliotekanauki.pl/articles/236334.pdf
Data publikacji:
2016
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
oczyszczanie ścieków
reaktor biologiczny
substancje biogenne
potencjał eutrofizujący
modelowanie komputerowe
BioWin
sewage treatment
biological reactor
nutrients
eutrophication potential
computer modeling
Opis:
Po 15 latach wdrażania Ramowej Dyrektywy Wodnej, której podstawowym celem było osiągniecie w 2015 r. dobrego stanu wszystkich wód w państwach unijnych, okazało się, że tylko 53% wód powierzchniowych w Europie osiągnęło ten cel, a nadmiar substancji biogennych występuje w około 30% wód w 17 państwach członkowskich, w tym także w Polsce. Taki stan powoduje dalszy rozwój eutrofizacji i związane z tym poważne komplikacje w zakresie wszystkich kategorii użytkowania wód. Fakty te wskazują na niekorzystny bilans poniesionych kosztów i uzyskanych korzyści w zakresie zapobiegania negatywnym skutkom eutrofizacji poprzez ograniczanie wprowadzania do wód powierzchniowych substancji biogennych z oczyszczalni ścieków, a także na brak osiągnięcia założonych efektów ekologicznych przy ogromnych nakładach inwestycyjnych i eksploatacyjnych. Oznacza to, że nadal występują luki w zakresie ustalania warunków wprowadzenia ścieków do wód, które nie uwzględniają wiedzy na temat postaci substancji biogennych potęgujących proces eutrofizacji. W środowisku wodnym takimi formami biogenów są ich formy bioprzyswajalne (mineralne), bezpośrednio dostępne dla autotroficznych organizmów roślinnych. Wyniki przeprowadzonych badań symulacyjnych, nakierowanych na poszukiwanie prostszych i tańszych technologii biologicznego usuwania substancji biogennych i odprowadzanie do odbiornika ścieków oczyszczonych o niskim potencjale eutrofizującym, potwierdziły możliwość doboru skutecznych technologii usuwania substancji biogennych, które jednocześnie pozwolą na ograniczenie kosztów inwestycyjnych i eksploatacyjnych oczyszczania ścieków i bardziej skuteczną ochronę odbiorników przed eutrofizacją.
15 years from starting the implementation of Water Framework Directive, primary objective of which was to achieve good status of all waters in the EU countries by 2015, only 53% of surface waters in Europe have reached the set goal, and excessive amounts of nutrients are observed in about 30% of water bodies in 17 member states, including Poland. Consequently, the eutrophication progresses causing serious complications with regard to all the water use categories. These facts indicate an unfavorable cost-benefit balance in terms of preventing adverse effects of eutrophication by reducing nutrient discharge from wastewater treatment plants and failure to achieve the set ecological goals despite huge capital expenditures and operating costs. This means that gaps in respect of determining the conditions of wastewater discharge into the receivers still exist, which prevent taking into account the knowledge on nutrient forms accelerating eutrophication. In the aquatic environment such forms of nutrients are their bioavailable mineral forms, immediately assimilable by autotrophic plant organisms. The results of computer simulations, aimed at identification of simpler and cheaper technologies of biological nutrient removal and discharge of an effluent of low eutrophication potential, confirmed feasibility of selecting effective nutrient removal technologies that would also limit the investment and operational costs of sludge wastewater treatment and provide more effective protection of receivers against eutrophication.
Źródło:
Ochrona Środowiska; 2016, 38, 3; 23-28
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ stałego pola magnetycznego na proces usuwania związków biogennych ze ścieków mleczarskich w reaktorze typu SBR
Influence of static magnetic field on removal of biogenic compounds from dairy wastewater in Sequencing Batch Reactor
Autorzy:
Zieliński, M.
Hajduk, A.
Dębowski, M.
Powiązania:
https://bibliotekanauki.pl/articles/949873.pdf
Data publikacji:
2017
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
stałe pole magnetyczne
ścieki mleczarskie
sekwencyjny reaktor biologiczny
związki biogenne
constant magnetic field
sewage dairy
sequential biological reactor
biogenic compounds
Opis:
Modyfikacje profilu produkcji w zakładach przemysłowych wpływają bezpośrednio na zmiany w ilości oraz składzie powstających ścieków. W związku z tym istnieje konieczność ciągłego poszukiwania nowych i skutecznych metod intensyfikujących usuwanie i neutralizację zanieczyszczeń. Przeprowadzone do tej pory badania pozwalają sądzić, iż czynnikiem pozytywnie wpływającym na różnego rodzaju jednostkowe procesy oczyszczania ścieków jest stałe pole magnetyczne (SPM). Celem badań było określenie wpływu stałego pola magnetycznego (SPM) o indukcji 0,6T na efektywność usuwania związków biogennych ze ścieków mleczarskich w reaktorach typu SBR. Badania przeprowadzono w warunkach laboratoryjnych, w dwóch wariantach różniących się obciążeniem osadu czynnego ładunkiem zanieczyszczeń. W trakcie badań udowodniono, iż zastosowanie SPM sprzyjało procesowi usuwania związków biogennych, choć znaczenie tego czynnika w większości wariantów nie było istotne. Niezależnie od wariantu eksperymentu obserwowano bardzo wysoką skuteczność usuwania związków azotu i fosforu z testowanych ścieków mleczarskich.
Modifications to the profile of production in factories directly affect the changes in the amount and composition of the resulting wastewater. Therefore, there is a continued search for new and effective methods for to intensify the removal of pollutants and neutralization. The studies conducted so far suggest that a constant magnetic field (CMF) constitutes a positive factor for various unit processes of wastewater treatment. The objective of the study was to determine the effect of a constant magnetic field (CMF) with the induction of 0.6T on the removal efficiency of nutrients from dairy wastewater in SBRs. Tests were performed under laboratory conditions, in two variants, different load of activated sludge and impurities. During the research, it was proven that the use of CMF was conducive to the elimination of biogenic compounds, although the significance of this factor in the majority of variants was not significant. Regardless of the variant of the experiment, a very high efficiency of nitrogen and phosphorus removal from the tested dairy wastewater was observed.
Źródło:
Inżynieria Ekologiczna; 2017, 18, 4; 7-12
2081-139X
2392-0629
Pojawia się w:
Inżynieria Ekologiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowanie procesu Fentona i sekwencyjnych reaktorów porcjowanych do oczyszczania ścieków z produkcji okien drewnianych
Application of fentons process and sequencing batch reactors for treatment of wastewater from wood windows manufacture
Autorzy:
Piaskowski, K.
Świderska-Dąbrowska, R.
Powiązania:
https://bibliotekanauki.pl/articles/1819655.pdf
Data publikacji:
2010
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
proces Fentona
reaktor biologiczny
oczyszczanie ścieków produkcyjnych
produkcja okien
Fenton process
biological reactor
treatment of wastewater production
production of windows
Opis:
Przeprowadzone badania nad oczyszczaniem ścieków klejowych po procesie Fentona z neutralizacją w reaktorze SBR pozwoliły na sformułowanie następujących wniosków: 1. Ścieki klejowe po procesie Fentona nie wykazywały negatywnego oddziaływania bezpośrednio na aktywność osadu czynnego w SBR, poprawiały natomiast właściwości sedymentacyjne kłaczków osadu. 2. Dozowanie ścieków klejowych po procesie Fentona z neutralizacjązwiększały pH do 8 oraz przewodność właściwą ścieków oczyszczonych, będącą pozostałością katalizatora procesu utleniania. 3. Wzrost ładunku węgla organicznego w reaktorze eksperymentalnym intensyfikował biologiczne usuwanie ortofosforanów, jednocześnie obniżając usuwanie związków azotu w procesie nitryfikacji. 4. Pomimo zastosowania chemicznego utleniania odczynnikiem Fentona, część węgla organicznego nie podlegała biodegradacji i kumulowała się w reaktorze, zwiększając stężenie OWO w ściekach oczyszczonych.5. Usunięcie węgla organicznego ze ścieków klejowych uzyskano w okresie prowadzonych badań na poziomie 44,8÷71,3%. 6. Wraz ze wzrostem obciążenia osadu ładunkiem organicznym od 53,3 do 398,5 mgC/gosźd, rosło jednostkowe usunięcie węgla organicznego od 23,9 do 284,1 mgC/gosźd.
The advanced oxidation process with Fenton's reagent can be used in industrial wastewater treatment, especially in the degradation of not easily biodegradable contaminations. Chemical oxidation of industrial wastewater or other substances as a pre-treatment before biological treatment is the most effective method of wastewater treatment. However, besides many advantages, the method has some restrictions: it requires low-pH (2-4) of wastewater and final neutralisation has to be performed, production of great amounts of iron-containing sediment. This paper presents laboratory experiments on treatment of adhesive wastewater in an SBR reactor after the Fenton process, with neutralisation at the end. The experiment sought to determine the effect of that purification system on the state of the activated sludge, the course of biological processes (nitrogen and phosphorus removal) and the effectiveness of wastewater treatment.The study was conducted on the test stand, which scheme is shown in Figure 1. This stand consisted of two sequential batch reactors SBR with working capacity of 3 liters. In such configuration SBR-1 reactor was the control reactor, while, in addition to the other one chemical wastewater after the Fenton process were added (SBR-2). The research was carried out on wastewater from the company producing of windows and doors. Wastewater come from washing and rinsing of adhesive installations. Adhesive wastewater after Fenton's process showed no negative impact directly on the activity of activated sludge in SBR, improving the sedimentary characteristics of sludge floes. Dosing of adhesive wastewater after Fenton's process with neutralisation increased the pH to 8, and the conductivity of the treated wastewater, which is a remnant of a catalyst for oxidation process. The increase of organic carbon load in the experimental reactor intensified biological removal of orthophosphates, while decreasing removal of nitrogen compounds in the process of nitrification. Despite application of chemical oxidation with Fenton's reagent, part of organic carbon was not subject to biodégradation and cumulated in the reactor, increasing the concentration of TOC in treated wastewater. Removal of organic carbon from adhesive wastewater obtained during research period was 44.8-71.3%. With the increase of sludge loading with organic load from 53.3 to 398.5 mgC/g0S-d, the unit removal of organic carbon increased from 23.9 to 284.1 mgC/g0S-d.
Źródło:
Rocznik Ochrona Środowiska; 2010, Tom 12; 503-523
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowanie biopreparatów do intensyfikacji oczyszczania ścieków metodą osadu czynnego
Application of biopreparation to intensify the treatment of wastewater with activated sludge
Autorzy:
Puszczało, E.
Świerczyńska, A.
Bohdziewicz, J.
Powiązania:
https://bibliotekanauki.pl/articles/126785.pdf
Data publikacji:
2015
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
biopreparat
osad czynny
sekwencyjny reaktor biologiczny
SBR
odcieki ze składowisk odpadów komunalnych
biopreparation
activated sludge
sequential biological reactor
municipal landfill leachates
Opis:
Celem badań było zastosowanie biopreparatu jako czynnika wspomagającego współoczyszczanie odcieków ze ściekami syntetycznymi metodą osadu czynnego. Badania prowadzono w sekwencyjnych reaktorach biologicznych o pojemności 3 dm3 (SBR). Stężenie osadu czynnego w SBR utrzymywano na poziomie 4,0 g/dm3, obciążenie osadu ładunkiem zanieczyszczeń kształtowało się na poziomie 0,05-0,1 g ChZT/g s.m. d, natomiast stężenie tlenu w komorze napowietrzania utrzymywano na poziomie 3 mg O2/dm3. Układ pracował w cyklu 12-godzinnym. Udział procentowy odcieków w mieszaninie ze ściekami syntetycznymi wynosił 5% obj. Substratem badań były odcieki pochodzące ze składowiska odpadów komunalnych w Tychach oraz ścieki syntetyczne przygotowane na bazie bulionu zgodnie z normą PN-72/C-04550. ChZT odcieków kształtowało się na poziomie średnio 3000 mg O2/dm3, a BZT5 wynosiło 280 mg O2/dm3. Stosunek BZT5/ChZT był bardzo niski i wahał się w przedziale 0,06-0,1. W odciekach ze składowisk odpadów komunalnych występowały również wysokie stężenia azotu amonowego przekraczające znacząco jego ilość w ściekach syntetycznych. Kryterium oceny stopnia oczyszczenia ścieków była zmiana wartości wskaźników zanieczyszczeń, tj.: ChZT, BZT5, OWO, stężenia P-PO4, Ncał, N-NO3, N-NH4. Stwierdzono, że dodatek biopreparatu w ilości 3 mg/dm3 poprawił stopień usunięcia fosforu fosforanowego, azotu azotanowego i całkowitego.
The aim of this study was the application of biopreparation to intensify the treatment of leachate with synthetic sewage sludge method. The experiments were performed in sequential biological reactor (SBR) of 3 dm3. The concentration of the activated sludge in the SBR was equal to 4.0 g/dm3, and the oxygen concentration in the aeration chamber was at the level of 3.0 g O2/m3. The sludge loading with contaminants was established at the level of 0.05 and 0.1 g COD/gTSd. The percentage share of leachates was 5 vol.%. The operational cycle of the bioreactor took 12 h. The substrate used in that studies was the leachate taken from the municipal landfill in Tychy and synthetic wastewater prepared from of broth according to standard PN-72/C-04550. COD was on the level of 3000 mg O2/dm3, and BOD5 was 280 mg O2/dm3. The ratio BOD5/COD of those leachates was very low and varied from 0.06. to 0.1. The municipal landfill leachates posses also significant amount of the ammonium nitrogen, which are much higher than those present in the synthetic sewage. The main criterion for the estimation of the effectiveness of the treatment process was the change of parameters indicating impurities content such as: COD, BOD5, contents of TOC, TC and concentrations P-PO4, Ntot, N-NO3, N-NH4. An addition of biocomponent to activated sludge bioreactor at amount of 3 mg/dm3 reduces P-PO4, N-NO3 and Ntot.
Źródło:
Proceedings of ECOpole; 2015, 9, 2; 677-683
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modelling of carbon and nitrogen compounds removal from domestic wastewater in a modernized biological reactor
Autorzy:
Makowska, M.
Jadanowski, S.
Tränckner, J.
Powiązania:
https://bibliotekanauki.pl/articles/207574.pdf
Data publikacji:
2018
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
biological reactor
domestic wastewater
activated sludge process
hybrid technology
removal nitrogen
reaktor biologiczny
ścieki domowe
proces osadu czynnego
proces hybrydowy
usuwanie azotu
Opis:
Upgrading concepts for the Bioblok MU200a wastewater treatment plant have been presented. The main goals were to achieve an effective nitrogen removal and reduce energy demand. The reference version has been presented, followed by two retrofitting options: introduction of intermittent aeration for alternating aerobic and anoxic conditions, additionally including a retrofitting option to a hybrid technology that combines advantages of activated sludge and biofilm. To design and assess both variants, the ASM3 model was used, running on the Simba# simulator. A rather complex biofilm model, necessary for the hybrid concept, was bypassed by installing a separate activated sludge process differing in terms of sludge age and disposal of its excess sludge to the reactor. In this way, favorable technological parameters for efficient wastewater treatment could be assessed. Both upgrading concepts can be recommended for their satisfactory treatment effectiveness, feasibility in existing plants and considerable energy savings. The significance of the modelled effects was statistically confirmed two-tailed Student’s t-test.
Źródło:
Environment Protection Engineering; 2018, 44, 4; 69-83
0324-8828
Pojawia się w:
Environment Protection Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wplyw parametrow technologicznych na ilosc biomasy w reaktorze biologicznym ze zlozem ruchomym
Influence of technological parameters on biomass in moving bed biological reactor
Autorzy:
Makowska, M.
Powiązania:
https://bibliotekanauki.pl/articles/40139.pdf
Data publikacji:
2007
Wydawca:
Szkoła Główna Gospodarstwa Wiejskiego w Warszawie. Wydawnictwo Szkoły Głównej Gospodarstwa Wiejskiego w Warszawie
Tematy:
reaktory z ruchomymi zlozami biologicznymi
reaktory biologiczne
osady czynne
blony biologiczne
biomasa
parametry technologiczne
oczyszczanie sciekow
active deposit
bacterial jelly
biological reactor
biomass
sewage treatment
technological parameter
Źródło:
Acta Scientiarum Polonorum. Architectura; 2007, 06, 2; 59-70
1644-0633
Pojawia się w:
Acta Scientiarum Polonorum. Architectura
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The impact of the sewer system rinsing on the wastewater composition
Autorzy:
Sadecka, Z.
Płuciennik-Koropczuk, E.
Myszograj, S.
Suchowska-Kisielewicz, M.
Jakubaszek, A.
Powiązania:
https://bibliotekanauki.pl/articles/207804.pdf
Data publikacji:
2013
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
sewers
pollution
sewage
sewage pumping plants
water treatment plants
biological reactor
sewage pollutions
wastewater treatment plants
kanalizacja
ścieki
przepompownie ścieków
stacje uzdatniania wody
reaktor biologiczny
zanieczyszczenia ścieków
oczyszczalnie ścieków
Opis:
The paper presents the results of research on the influence of the operational rinsing of a sewer system on the composition of raw sewage, the effectiveness of the operation of the mechanical part of a wastewater treatment plant and changes in the technological parameters of the biological reactor. The results of the research have shown an increase in sewage pollution during the rinsing of the sewer system. The value of the COD indicator increased from 799 to 1306 mg/dm3, BOD5 from 538 to 1044 mg/dm3, and total suspended solids from 259 to 1508 mg/dm3. The calculations indicate that an increase in the concentrations of pollution during the rinsing of the sewer system requires a high working efficiency of the mechanical part of the wastewater treatment plant. With a low efficiency the volume of the biological reactor can increase even by 30%.
Źródło:
Environment Protection Engineering; 2013, 39, 2; 5-13
0324-8828
Pojawia się w:
Environment Protection Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Stan awaryjny reaktorów biologicznych A i B znajdujących się na oczyszczalni ścieków w Wałczu jako skutek popełnionych błędów przy ich projekcie i użytkowaniu
Emergency state of biological reactors located in the area of sewage treatment plant in Walcz as a result of commited faults during their projection process and expliotation
Autorzy:
Przybyłowicz, E.
Pikos, M.
Powiązania:
https://bibliotekanauki.pl/articles/160299.pdf
Data publikacji:
2017
Wydawca:
Polski Związek Inżynierów i Techników Budownictwa
Tematy:
oczyszczalnia ścieków
zbiornik na ścieki
reaktor biologiczny
zbiornik żelbetowy
stan techniczny
pęknięcie
destrukcja betonu
analiza przyczyn
wastewater treatment plant
sewage tank
biological reactor
reinforced concrete tank
technical condition
crack
concrete destruction
causes analysis
Opis:
W pracy omówiono uszkodzenia i przyczyny, które doprowadziły do stanu awaryjnego dwóch reaktorów biologicznych na remontowanej oczyszczalni ścieków w Wałczu. Powstałe uszkodzenia ścian i den zbiorników stworzyły zagrożenie skażenia środowiska ściekami komunalnymi. Bezpośrednią przyczyną tego stanu były popełnione błędy na etapie projektowania konstrukcji zbiorników bez zachowania odpowiednich zasad odnośnie posadowienia, rozwiązań dylatacji, zbrojenia i wymagań co do jakości betonu. W reaktorach nie zastosowano odpowiednich powłok ochronnych na betonie, co w połączeniu ze złą jakością betonu doprowadziło do całkowitej degradacji obiektów i podjęcia decyzji o ich rozbiórce z uwagi na nieopłacalny remont.
Present paper discusses the damages and causes that led to the emergency condition of two biological reactors on the renovated sewage treatment plant in Walcz. Resulting damages of walls and bottom of tanks caused a risk of contamination of the environment with municipal sewage. The direct cause of this condition was mistakes/errors made at the stage of structural design of the tanks without maintaining proper rules of foundation process, construction of dilation, propositions of suitable reinforcements and concrete quality requirements. In the reactors appropriate protective coatings on a concrete were not used, which, in combination with poor quality of concrete, led to complete degradation of objects and decided to demolish them due to unprofitable repairs.
Źródło:
Przegląd Budowlany; 2017, 88, 9; 86-88
0033-2038
Pojawia się w:
Przegląd Budowlany
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza skuteczności działania oczyszczalni ścieków pracującej w systemie SBR
Performance analysis of sewage treatment plant working in the SBR system
Autorzy:
Bartkowska, I.
Klaus, W.
Powiązania:
https://bibliotekanauki.pl/articles/908416.pdf
Data publikacji:
2013
Wydawca:
Fundacja Ekonomistów Środowiska i Zasobów Naturalnych
Tematy:
gospodarka ściekowa
projektowanie oczyszczalni
oczyszczalnia ścieków
skuteczność oczyszczania ścieków
sewage treatment
biological sequencing batch reactor
designing sewage treatment plant
sewage treatment plant
effluent treatment effect
Opis:
Technologia oczyszczania ścieków osadem czynnym w systemach porcjowych znana już była na początku XX wieku. W 1912 roku Fowler zastosował do oczyszczania ścieków miejskich w Manchesterze napowietrzanie ścieków strumieniem pęcherzyków powietrza wytwarzanych w sposób pneumatyczny wraz z następującym po nim etapem sedymentacji. W 1914 roku studenci Fowle'a – Ardern i Lockett – zaprezentowali oczyszczanie ścieków w systemie z napełnianiem i dekantacją bez pozbywania się biologicznych osadów nagromadzonych w czasie cyklicznego napowietrzania ścieków.
This paper presents an assessment of wastewater treatment plants operating in the technological sequence of biological reactors (SBR) as an example Olecko. This paper presents qualitative characteristics of raw sewage to the treatment plant infl uent and effl uent. Assesses the work of the treatment on the basis of tests erformed and operating experience. The analysis is based on the results of the following indicators of pollutants: OD5, COD, pH, concentration of total nitrogen, total phosphorus and total suspended solids. A description of modernized in 2009 technology of sewage treatment plant and sewage sludge management was presented.
Źródło:
Ekonomia i Środowisko; 2013, 4; 107-117
0867-8898
Pojawia się w:
Ekonomia i Środowisko
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ obecności węglowodorów aromatycznych (BTX) w ściekach komunalnych na proces biologicznej defosfatacji
The influence of aromatic hydrocarbons (BTX) presence in municipal sewage on the biological dephosphatation process
Autorzy:
Mrowiec, B
Powiązania:
https://bibliotekanauki.pl/articles/400086.pdf
Data publikacji:
2013
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
węglowodory aromatyczne (BTX)
proces osadu czynnego
biologiczna defosfatacja
reaktor SBR
aromatic hydrocarbons (BTX)
activated sludge process
biological dephosphatation
SBR reactor
Opis:
W badaniach analizowano efektywność procesu biologicznej defosfatacji w warunkach występowania węglowodorów aromatycznych (BTX) w stężeniu od 1,0 do 5,3 mg/ dm3. Jako materiał badawczy zastosowano ścieki syntetyczne, ścieki komunalne oraz ścieki wzbogacone cieczą osadową. Efektywność usuwania fosforu dla ścieków z dodatkiem BTX wahała się od 36,4 do 86,3 %, natomiast w przypadku prób kontrolnych – bez BTX od 22,5 do 83,8%. Wyliczone średnie efektywności defosfatacji wynosiły: dla ścieków z BTX – 72,9%, a dla ścieków bez węglowodorów – 67,4%. Z analizy efektywności usuwania fosforu wynika, że dla niższych stężeń fosforu ogólnego w ściekach surowych uzyskano wyższą efektywność usuwania fosforu w próbach z BTX.
The efficiency of biological dephosphatation under conditions of the presence of aromatic hydrocarbons (BTX) in the concentration of 1.0 to 5.3 mg/L has been investigated. As the research material synthetic wastewater, municipal wastewater and the wastewater enriched by supernatant sludge were used. Phosphorus removal efficiency in wastewater treatment process with BTX ranged from 36.4 to 86.3% while, in case of control samples from 22.5 to 83.8%. The estimated average values of dephosphatation efficiency amounted to 72.0% and 67.4% for wastewater treatment with BTX and wastewater treatment without hydrocarbons respectively. The analysis of phosphorus removal efficiency shows that for the lower values of phosphorus concentration in raw wastewater the higher efficiency of phosphorus removal in the samples with BTX were achieved.
Źródło:
Inżynieria Ekologiczna; 2013, 32; 131-138
2081-139X
2392-0629
Pojawia się w:
Inżynieria Ekologiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-14 z 14

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies