Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "aerobic reactors" wg kryterium: Temat


Wyświetlanie 1-3 z 3
Tytuł:
Innovative sequential batch reactor solutions for wastewater treatment
Innowacyjne rozwiązania sekwencyjnych reaktorów porcjowych stosowane w oczyszczaniu ścieków
Autorzy:
Kowalik, Robert
Gawdzik, Jarosław
Gawdzik, Alicja
Gawdzik, Barbara
Powiązania:
https://bibliotekanauki.pl/articles/402272.pdf
Data publikacji:
2019
Wydawca:
Politechnika Świętokrzyska w Kielcach. Wydawnictwo PŚw
Tematy:
wastewater treatment
modern wastewater treatment methods
aerobic reactors
SBR
CASS
UNITANK
ICEAS
oczyszczanie ścieków
nowoczesne metody oczyszczania ścieków
reaktory tlenowe
Opis:
Sequential Biological Reactors (SBR) are widely used for wastewater treatment, which is becoming increasingly contaminated with new and more complex substances. Therefore, it is beneficial to include various configurations and operational modifications in order to purify wastewater more effectively. The paper presents a basic description of the SBR process and its modifications, which lead to better removal of the resulting contaminants. The Cyclic Activated Sludge System (CASS) was characterized as one of the most popular sequential reactor (SBR) processes used for the treatment of municipal wastewater and sewage emissions from a variety of industries, including refineries and petrochemicals. Another example presented in this paper is the Unitank biological wastewater treatment system, which combines the advantages of a traditional process with activated sludge and an SBR reactor. The last example of SBR technology modification, presented in the article, is ICEAS (Intermediate Cycle Extended Aeration System) process, which processes continuous sewage inflow. The variable inlet is supported by a distribution box which distributes the flow evenly over all the tanks in order to avoid overloading a single tank. In each case, the benefits of using a given modification are presented.
Sekwencyjne biologiczne reaktory (SBR) są szeroko wykorzystywane do oczyszczania ścieków, które obecnie stają się zanieczyszczone coraz to nowymi i bardziej złożonymi substancjami. Korzystne zatem staje się włączenie różnego rodzaju rozszerzających się konfiguracji oraz modyfikacji operacyjnych, aby efektywniej oczyszczać ścieki. W pracy przedstawiono podstawowy opis procesu SBR oraz jego modyfikacji, które prowadzą do lepszego usuwania powstających zanieczyszczeń. Scharakteryzowano cykliczny system osadów czynnych (CASS), który jest jednym z najpopularniejszych procesów reaktorów sekwencyjnych (SBR) stosowanych do oczyszczania ścieków komunalnych oraz ścieków z różnych branż, w tym rafinerii i zakładów petrochemicznych. Kolejnym przykładem przedstawionym w pracy jest biologiczny system oczyszczania ścieków Unitank, który łączy w sobie zalety tradycyjnego procesu z osadem czynnym oraz reaktora SBR. Ostatnim przykładem modyfikacji technologii SBR, jaki przedstawiono w artykule, jest proces ICEAS (Intermediate Cycle Extended Aeration System). W reaktorach ICEAS zmienny dopływ jest obsługiwany przez skrzynkę rozdzielającą, która rozdziela przepływ równomiernie na wszystkie zbiorniki tak, aby uniknąć przeciążenia pojedynczego zbiornika. W każdym przypadku przedstawiono korzyści płynące z wykorzystania danej modyfikacji.
Źródło:
Structure and Environment; 2019, 11, 2; 141-152
2081-1500
Pojawia się w:
Structure and Environment
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
An Application of Anaerobic-Aerobic Combined Bioreactor Efficiency in COD Removal
Autorzy:
Kavousi, Rezvan
Borghei, Seyyed Mehdi
Powiązania:
https://bibliotekanauki.pl/articles/27314286.pdf
Data publikacji:
2023
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
hydraulic loading
anaerobic-aerobic combined reactors
COD removal
fixed bed bioreactor
Kaldnes packing
municipal wastewater
industrial wastewater
Opis:
Over the past few decades, anaerobic-aerobic wastewater treatment systems have been widely used in industrial and municipal wastewater treatment. This study was conducted to examine the effects of combined anaerobic-aerobic bioreactors in the removal of chemical oxygen demands (COD) while reducing phosphate concentrations in synthetic wastewater. In this project, a bioreactor with the dimensions of 10 cm × 10 cm × 80 cm with respective Kaldnes packing ratios of 90 and 30% for the anaerobic and aerobic sections was designed. A combined anaerobic-aerobic reactor’s structure made changing hydraulic retention times only possible by adjusting the volume of its aerobic and anaerobic sections. In the first case, the anaerobic and aerobic sections of the reactor occupied 30 and 50 cm of its height, respectively. The height of the anaerobic section decreases to 12.5 cm in the second case. In aerobic and anaerobic sections, pH was within a neutral range, temperature was 37°C. MLSS (mixed liquor suspended solids) was 1220 and 1030 mg/L, and attached growth was 743 and 1190 mg/L respectively. In order to evaluate COD in the wastewater, three different initial phosphorus concentrations were tested: 12.8, 32.0 and 44.8 mg/L, as well as four COD: 500, 1000, 1200 and 1400 mg/L. Considering the results, COD removal is greater than 80% when the valve 2 is in the anaerobic section outlet regardless of the concentration of phosphate. In this case, the best result is for inlet COD of 500, where the reactor can eliminate more than 90%. When the COD concentration reaches 1000 to 1400 ppm, the reactor’s COD removal efficiency declines to 60%.
Źródło:
Geomatics and Environmental Engineering; 2023, 17, 4; 5--18
1898-1135
Pojawia się w:
Geomatics and Environmental Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Enrichment of PAO and DPAO responsible for phosphorus removal at low temperature
Autorzy:
Haiming, Z.
Xiwu, L.
Abualhail, S.
Jing, S.
Qian, G.
Powiązania:
https://bibliotekanauki.pl/articles/207785.pdf
Data publikacji:
2014
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
wastewater treatment
phosphorus removal
bacteria
batch reactors
aerobic condition
polyphosphate accumulating organisms
PAO
denitrifying polyphosphate accumulating organisms
DPAO
oczyszczanie ścieków
usuwanie fosforu
bakteria
reaktory wsadowe
warunki beztlenowe
analiza mikrobiologiczna
biologiczne usuwanie fosforu
organizmy akumulujące polifosforany
Opis:
A new strategy of enrichment of polyphosphate accumulating organisms (PAO) and denitrifying polyphosphate accumulating organisms (DPAO) at low temperature ranging from 8 °C to 11 °C was demonstrated through two lab-scale reactors operated in sequential anaerobic-aerobic (AO) or anaerobic-anoxic (AA) conditions. It was found that the AO reactor is able to achieve a good phosphorus removal performance after 40 days of operation, while a similar stable phosphorus removal can be obtained in the AA reactor after 80 days. This result suggests that the enrichment of PAO was easier than that of DP AO at low temperature. Through switching batch tests, when DPAO is exposed to aerobic conditions, it can immediately exhibit a good phosphorus removal similar to that under anoxic conditions, while PAO can only present poor phosphorus removal when exposed to anoxic conditions, suggesting that two different types of Accumulibacter were enriched both in AA and AO reactors. Microbial analysis with fluorescence in situ hybridization (FISH) and DAPI (4',6-diamidino-2 -phenylindole) staining revealed that Accumulibacter was dominant both in the two reactors, accounting for 61.6% and 79.3% of all bacteria in AA and AO reactors, respectively. Although the different amount of Accumulibacter was enriched in the two reactors, the similar microbial morphologies were observed by using scanning electron micrograph (SEM), both presenting long-rod morphology. This kind of Accumulibacter may display affinities for sodium acetate used as the carbon sources here. This strategy proposed in this study was shown to be effective in achieving a very high enrichment of Accumulibacter at low temperature by linking chemical analysis with microbial observation.
Źródło:
Environment Protection Engineering; 2014, 40, 1; 67-83
0324-8828
Pojawia się w:
Environment Protection Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-3 z 3

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies