Tytuł:
Measurement strategy as a determinant of the measurement uncertainty of an optical scanner
Autorzy:
Koteras, Robert
Wieczorowski, Michał
Znaniecki, Piotr
Swojak, Natalia
Powiązania:
https://bibliotekanauki.pl/articles/94194.pdf
Data publikacji:
2019
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
coordinate measuring machine
optical scanner
measurement strategy
accuracy of measurement
Opis:
The subject of the article is an attempt to determine the impact of the applied measurement strategy on the accuracy of the measurement result. This problem is particularly crucial when measuring large objects. In these cases, it is not always possible to provide ideal conditions for the submission of particular scans. It is necessary to adjust the strategy to specific imposed conditions defined by the geometry of the object and to the time frame of the measurement itself. With regard to the above, an attempt was made to carry out a series of accuracy studies testing the structural light scanner while measuring elements of overall dimensions greater than the measuring capacity of the scanner. At the same time, various potential measuring strategies were simulated in practical applications. Our studies were conducted using a pre-designed test template with a defined distribution pattern of reference points and geometrical elements. Moreover, in order to make an in-depth investigation of the issue, some trials were undertaken with the use of limiting parameters. That means the scanner had both an excess and shortage of information required for a correct assembly of scans. Those scopes were taken into consideration in the study in order to use the acquired knowledge in practical measuring applications. Furthermore, conclusions from the conducted studies indicate peaks and troughs of respective measuring strategies with special care for determining relationships among the used strategies and the measuring accuracy parameters.
Źródło:
Archives of Mechanical Technology and Materials; 2019, 39; 26-31
2450-9469
Pojawia się w:
Archives of Mechanical Technology and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Dokładnie, czyli jak?
Accurately, which is how?
Autorzy:
Gadomska, Aleksandra
Powiązania:
https://bibliotekanauki.pl/articles/952618.pdf
Data publikacji:
2018
Wydawca:
Główny Urząd Miar
Tematy:
metrologia
terminologia
dokładność pomiaru
metrology
terminology
accuracy of measurement
Opis:
Od 100 lat oficjalnie w Polsce mierzymy i ważymy, i robimy to z coraz większą dokładnością. Jednak ten, jakże ważny metrologiczny termin, jest niezwykle często przedstawiany w zupełnie niewłaściwym znaczeniu. Pożądana przez wszystkich metrologów jednolitość, to również jednolicie rozumiana terminologia. Niestety w zakresie „dokładności” sytuacja jest więcej niż niejednoznaczna. Artykuł przedstawia słownikową definicję tego terminu, jego interpretację oraz zawiera przykłady jego niewłaściwego użycia. Wskazuje możliwe kierunki działań służących poprawie terminologicznych niejednoznaczności.
We have been officially measuring and weighing in Poland for 100 years, and we are doing it with increasing accuracy. However, this important metrological term is enormously often presented in a completely wrong meaning. The uniformity desired by all metrologists is also a uniformly understood terminology. Unfortunately, in terms of "accuracy” the situation is more than ambiguous. This article presents a vocabulary definition of this term, its interpretation and contains examples of its misuse. The article summary indicates possible directions of actions to improve terminological ambiguities.
Źródło:
Metrologia i Probiernictwo : biuletyn Głównego Urzędu Miar; 2018, 2 (21); 57-60
2300-8806
Pojawia się w:
Metrologia i Probiernictwo : biuletyn Głównego Urzędu Miar
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Verification of the measurement system in a production organization
Analiza systemu pomiarowego w przedsiębiorstwie produkcyjnym
Autorzy:
Prístavka, Miroslav
Findura, Pavol
Beloev, Ivan
Kuboń, Maciej
Hrdá, Veronika
Kovalyshyn, Stepan
Shchur, Taras
Powiązania:
https://bibliotekanauki.pl/articles/2204298.pdf
Data publikacji:
2022
Wydawca:
Polskie Towarzystwo Inżynierii Rolniczej
Tematy:
accuracy of measurement device
repeatability
reproducibility
przyrząd pomiarowy
sprawność
powtarzalność
odtwarzalność
Opis:
Monitoring the accuracy of meters by qualified workers and managers is a preventive measure of every organization. The paper focuses on monitoring the accuracy of measuring devices and proposes preventive and corrective actions. The discussed measurement device was tested for accuracy using accuracy indexes Cg and Cgk. The identified deviations in measurements showed that the meter was not fully efficient. Consequently, actions were taken to ensuring that the measurement device is accurate.
Monitorowanie sprawności mierników to działanie prewencyjne każdej organizacji. Pracownicy działów jakości oraz osoby odpowiedzialne za kontrolę i pomiary wyrobów końcowych są zobowiązani do ciągłej kontroli sprzętu pomiarowego. W artykule skupiono się na monitorowaniu dokładności przyrządu pomiarowego oraz zaproponowaniu działań zapobiegawczych i korygujących. Dokładność przyrządu pomiarowego określono za pomocą wskaźników dokładności Cg i Cgk. Stwierdzono, że odchylenia w pomiarach świadczą o tym, że miernik nie jest w pełni sprawny. W związku z tym podjęto działania naprawcze, które zapewniły sprawność przyrządu pomiarowego.
Źródło:
Agricultural Engineering; 2022, 26, 1; 81--90
2083-1587
Pojawia się w:
Agricultural Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Accuracy of land parcel area measurement
Dokładność pomiaru powierzchni parcel gruntowych
Autorzy:
Kwinta, A.
Powiązania:
https://bibliotekanauki.pl/articles/385460.pdf
Data publikacji:
2012
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
dokładność pomiaru
pomiar powierzchni
technologia satelitarna
accuracy of measurement
area measurement
satellite technology
Opis:
In connection with direct subsidies to agriculture in European Union, each year hundreds of thousands of measurements of crops and allotments are performed. Area measurements are performed directly on site using geodetic or aerial photogrammetry methods. It is widely used for the control of the hand (navigation) satellite receivers. The receiver has recorded a trace of movement along the land. This measurement method is quick and not expensive. Comparison of results of measurements made in this type of technology with the allowable tolerance of an area shows that the theoretically obtained accuracy is suffcient. In real measurements a main source of error is improper identification of crops borders which – in many cases – are ambiguous.
W Unii Europejskiej w związku z dopłatami bezpośrednimi do rolnictwa rocznie wykonuje się setki tysięcy bezpośrednich pomiarów powierzchni zasiewów i działek gruntowych. Pomiary powierzchni wykonuje się bezpośrednio w terenie metodami geodezyjnymi lub fotogrametrycznie na podstawie zdjęć lotniczych. Powszechnie do kontroli wykorzystuje się ręczne (nawigacyjne) odbiorniki satelitarne. W odbiorniku rejestruje się ślad przemieszczania się wzdłuż granic działki. Taka metoda pomiarowa jest szybka i niedroga. Porównanie wyników pomiarów wykonywanych tego typu technologią z dopuszczalna tolerancją powierzchni wskazuje, że teoretycznie uzyskiwane dokładności są wystarczające. W rzeczywistych pomiarach głównym źródłem błędów jest niewłaściwa identyfikacja granic zasiewów, które w wielu przypadkach są niejednoznaczne.
Źródło:
Geomatics and Environmental Engineering; 2012, 6, 2; 71-83
1898-1135
Pojawia się w:
Geomatics and Environmental Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Z precyzją do miliardowych części sekundy
Autorzy:
Czubla, A.
Powiązania:
https://bibliotekanauki.pl/articles/1426045.pdf
Data publikacji:
2013
Wydawca:
Główny Urząd Miar
Tematy:
pomiar czasu
zegary atomowe
dokładność pomiaru
time measurement
atomic clocks
accuracy of measurement
Opis:
Przeczytaj, jak jest ustalany czas urzędowy w Polsce.
Źródło:
Metrologia i Probiernictwo : biuletyn Głównego Urzędu Miar; 2013, 1; 14-15
2300-8806
Pojawia się w:
Metrologia i Probiernictwo : biuletyn Głównego Urzędu Miar
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Elektryczny kalibrator elektrod redox
Electrical calibrator of redox electrodes
Autorzy:
Suchocki, K.
Powiązania:
https://bibliotekanauki.pl/articles/152779.pdf
Data publikacji:
2010
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
pomiar potencjału redox
kalibracja
dokładność pomiaru
measurements of redox potential
calibration
accuracy of measurement
Opis:
Pomiar wartości potencjału redox jest wykorzystywany do oceny stanu środowiska naturalnego, dlatego bardzo istotna jest dokład-ność z jaką jest on wykonywany. Duży wpływ ma na nią między innymi kalibracja elektrod redox wraz z dołączonymi do nich urządzeniami pomiarowymi. Do chwili obecnej kalibrację elektrod redox wykonuje się przy pomocy roztworów redox, co niestety nie gwarantuje jej dużej dokładności. W celu jej poprawy opracowano koncepcję elektrycznego kalibratora redox. Urządzenie to charakteryzuje się prostą konstrukcją i pozwala na szybką i dokładną kalibrację elektrod redox napięciem bipolarnym w bardzo szerokim zakresie. W artykule omówiono budowę elektrycznego kalibratora redox, a także przeanalizowano czynniki wpływające na rozkład potencjału pola elektrycznego w jego elektrodzie kalibracyjnej. Omówiono także wpływ konstrukcji kalibratora na szybkość ustalania się rozkładu potencjału pola elektrycznego i dokładność przeprowadzanej kalibracji elektrod redox.
Measurements of the redox potential value are used in estimation of the natural environment condition, for this reason it is important to take the measurements accurately. The redox electrodes calibration together with measuring devices connected to the electrodes influ-ence the measurement accuracy significantly. Nowadays the cali-bration of the redox electrodes is performed with use of redox solutions which, unfortunately does not always provide the adequate accuracy. Therefore, an electrical redox calibrator has been devel-oped. This device has a simple construction and allows fast and accurate calibration of the redox electrodes in a broad range with use of bipolar voltage. In the paper the electrical structure of the redox calibrator is presented. The factors influencing the decomposition of the electric field potential are analysed. Additionally, the influence of the calibrator construction on the speed of the electric potential field decomposition settlement as well as the accuracy of the performed redox electrodes calibration are discussed.
Źródło:
Pomiary Automatyka Kontrola; 2010, R. 56, nr 8, 8; 848-850
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The influence of condition of the ionosphere on the accuracy of Real Time Kinematic GPS measurements
Wpływ stanu jonosfery na dokładność pomiarów RTK GPS
Autorzy:
Pluta, M.
Powiązania:
https://bibliotekanauki.pl/articles/385414.pdf
Data publikacji:
2013
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
dokładność pomiarów
jonosfera
pomiar RTK
accuracy of measurement RTK GPS
condition of the ionosphere
Real Kinematic Measurement GPS
Opis:
The aim of this paper is to examine the influence of the ionosphere on the RTK (Real Time Kinematic) GPS accuracy results. Precision of the measurement in the land surveying indicates the correctness of the execution of the task. The value is recognized as correct when the correlations between results of measurement and estimate parameters are compiled. Also assumptions of mean error and correlations between measuring parameters are important. The measurement with using satellite systems, taking into the way which a signal must cross, meaning from the satellite to the receiver, is a technological complicated task. There are many factors affecting the quality of the received signal, which determine the measurement accuracy, and one of them is the ionosphere. The complex physicochemical processes that take place in the ionosphere, have a profound effect on the propagation of electromagnetic waves, and thus they cause an ionospheric delay. A ionospheric delay is a direct cause of the decrease of accuracy of the RTK GPS measurements. The main purpose of this paper was to find the correlation between the activity of the ionosphere, expressed by the index 195, and the season of the year and the time of a day, and therefore to indicate the most beneficial time to carry out the measurement with the use of RTK GPS technique.
Artykuł przedstawia wyniki badań wpływu stanu jonosfery na dokładność pomiarów RTK GPS. Dokładność pomiaru, w pracach geodezyjnych, świadczy o poprawności wykonania danego zadania. Pomiar z wykorzystaniem systemów satelitarnych - biorąc pod uwagę drogę, jaką musi przejść sygnał od satelity do odbiornika - jest niezwykle trudny pod względem technologicznym. Istnieje wiele czynników wpływających na jakość sygnału odbieranego, warunkujących dokładność pomiaru. Jednym z tych czynników, omawianych w niniejszej pracy, jest jonosfera. Zachodzące w niej złożone procesy fizykochemiczne istotnie wpływają na propagację fal elektromagnetycznych, powodując opóźnienie jonosferyczne będące bezpośrednią przyczyną zmniejszenia dokładności pomiaru RTK GPS. Celem autorki było znalezienie zależności między aktywnością jonosfery wyrażaną wartością indeksu 195 a porą dnia oraz porą roku. Zależność ta wskazuje czas najkorzystniejszy dla przeprowadzenia pomiaru techniką RTK GPS.
Źródło:
Geomatics and Environmental Engineering; 2013, 7, 2; 59-69
1898-1135
Pojawia się w:
Geomatics and Environmental Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Współrzędnościowe pomiary kół zębatych walcowych
Coordinate measurement of gears
Autorzy:
Grzelka, M.
Powiązania:
https://bibliotekanauki.pl/articles/156170.pdf
Data publikacji:
2007
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
koła zębate
technika współrzędnościowa
dokładność pomiarów
korekta współrzędnych
gears
Coordinate Measuring Technique
accuracy of measurement
correction of coordinates
Opis:
Kołom zębatym, jako elementom odpowiedzialnym za przenoszenie ruchu, stawiane są coraz większe wymagania dotyczące ich dokładności wykonania. Przemysł samochodowy i lotniczy oprócz wymogów dokładności geometrycznej stawia warunki na dokładność kinematyczną a w najbliższej perspektywie dynamiczną. Prace prowadzone w Zakładzie Metrologii i Systemów Pomiarowych dotyczą zarówno analizy dokładności pomiarów geometrycznych kół zębatych, jak również odchylenia kinematycznego i dynamicznego przekładni zębatych. W artykule przedstawiono szczegółową analizę dokładności pomiarów współrzędnościowych kół zębatych wraz z porównaniem z pomiarami na specjalizowanych maszynach pomiarowych do kół zębatych. Na podstawie przeprowadzonych badań, analiz i symulacji przedstawiono ogólną postać błędów pomiarów współrzędnościowych i przedstawiono wytyczne dotyczące możliwości zastosowania odpowiedniej klasy maszyn współrzędnościowych do pomiaru kół zębatych walcowych wykonanych w określonych klasach dokładności.
The gears are responsible for transmission of movement, and their accuracy requirements are going higher. The motor and plane industry apart of geometrical accuracy emphasizes conditions on the cinematic accuracy, and in close perspective on the dynamic accuracy. The researches of the Division of Metrology and Measurement System are directed not only towards the higher accuracy of gears geometry measurement, but also towards the measurement of cinematic and dynamic deviations. In the paper, the detailed analysis of the accuracy of coordinate measurement of gears compared with the measurement using specialized gears measurement devices have been carried out. The performed researches and analysis led to the general conclusions on the coordinate gears measurement inaccuracy. The recommendations on the application of appropriate coordinate measuring machine accuracy class for the measurement of cylindrical gears with particular tolerance, have been presented, too.
Źródło:
Pomiary Automatyka Kontrola; 2007, R. 53, nr 9 bis, 9 bis; 489-492
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Uwagi o wykorzystaniu tachimetrów bezlustrowych w inwentaryzacji architektonicznej
Some remarks concerning the use of reflectorless total stations for architectural recording
Autorzy:
Klimkowska, H.
Wróbel, A.
Powiązania:
https://bibliotekanauki.pl/articles/1050662.pdf
Data publikacji:
2006
Wydawca:
Stowarzyszenie Geodetów Polskich
Tematy:
inwentaryzacja architektoniczna
dokładność pomiaru
tachimetr
bezlustrowy pomiar odległości
object documentation
accuracy of distance measurement
total station
reflectorless distance measurement
Opis:
W ostatnich latach obserwuje się szybki rozwój instrumentów wykorzystujących pomiar odległości bez konieczności stosowania luster. Przeprowadzono badania, które wykazały, że dokładność pomiaru odległości do płaskich i równych ścian wynosi około ±3 mm Z dotychczasowych doświadczeń stosowania takich tachimetrów w pomiarach inwentaryzacyjnych wynika, że pojawiają się problemy z dokładnością pomiaru narożników obiektu. Pomiar odległości odbywa się, bowiem za pomocą wiązki lasera, która daje na obiekcie plamkę o średnicy kilka do kilkudziesięciu mm w zależności od odległości. Odległość jest mierzona nie do punktu, a do pewnej powierzchni. Powoduje to błędy w pomiarze odległości do narożników. Z przeprowadzonych przez autorów badań wynika, że pomiar odległości do narożnika wklęsłego charakteryzuje się błędem systematycznym zmniejszającym wartość odległości o kilka mm (efekt zaokrąglenia narożnika). Pomiar narożników wypukłych jest obarczony podobnym błędem na plus, ale pod warunkiem, że cała wiązka lasera odbija się od bliskiego otoczenia narożnika. Jeżeli celujemy na narożnik tak, iż część wiązki trafia obok narożnika i odbija się od dalszych obiektów, błędy pomiaru odległości mogą wynosić od kilkunastu do kilkudziesięciu mm, a czasami nawet więcej.
In recent years, there has been rapid progress of instruments which are able to measure distance without using reflectors. This method of measurement has been adopted in laser scanners and in some total stations. The range of distance measurement, as well as its accuracy, make it useful for architectural measuring purposes. According to the producers’ information, the accuracy of distance measurement with reflectorless total stations varies between 3 and 5 mm, with the range of measurement up to 1 200 m. The accuracy of object documentation required by Polish technical standards (G-3.4) is 1÷3 cm (for well-preserved objects) – thus, the usage of reflectorless total stations fulfills the accuracy requirements. Experiments using reflectorless total stations in architectural documentation measurements show some problems with pointing onto the wall-corner points. The distance measurement take place with a laser bundle, which illuminates a spot on the object’s surface. The size of the spot is a dozen or so for 50m distance from object, and it increases along with the distance from the object. This means that the resulting measuring distance is the average of the spot surface distances. When the measuring point is the corner of a wall, such an average distance does not match the proper corner point distance. There are two cases of corners (convex or concave corner) and the results of measurements are different for both of them. In case of concave corners, the average distance of the spot is smaller than the real corner distance. The test measurements shows, that this difference is not greater than a few millimeters. Such a difference can be disregarded. The worse case is with convex corners – part of the spot can touch further objects, so the result can differ more, from over a dozen up to several dozen millimeters (max. 130 mm). In such cases, a good solution could be achieved with a proper method of pointing – the whole spot should touch the wall, close to the corner. The result of test measurements (with the execution of pointing requirements) gives the standard deviation of the measured distance ca ±3 mm. Such accuracy proves that reflectorless total stations can be used not only for direct documentation measurements, but also for determination of photogrammetric control points (signalized or not).
Źródło:
Archiwum Fotogrametrii, Kartografii i Teledetekcji; 2006, 16; 297-303
2083-2214
2391-9477
Pojawia się w:
Archiwum Fotogrametrii, Kartografii i Teledetekcji
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Identifying an Appropriate Forecasting Model for Forecasting Total Import of Bangladesh
Autorzy:
Khan, Tanvir
Powiązania:
https://bibliotekanauki.pl/articles/465624.pdf
Data publikacji:
2011
Wydawca:
Główny Urząd Statystyczny
Tematy:
ARIMA model
Holt Winters’ trend and seasonality method
VAR model
Forecasting accuracy
Out-of-sample accuracy measurement
Opis:
Forecasting future values of economic variables are some of the most critical tasks of a country. Especially the values related to foreign trade are to be forecasted efficiently as the need for planning is great in this sector. The main objective of this research paper is to select an appropriate model for time series forecasting of total import (in taka crore) of Bangladesh. The decision throughout this study is mainly concerned with seasonal autoregressive integrated moving average (SARIMA) model, Holt-Winters’ trend and seasonal model with seasonality modeled additively and vector autoregressive model with some other relevant variables. An attempt was made to derive a unique and suitable forecasting model of total import of Bangladesh that will help us to find forecasts with minimum forecasting error.
Źródło:
Statistics in Transition new series; 2011, 12, 1; 179-192
1234-7655
Pojawia się w:
Statistics in Transition new series
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Application of selected statistical tests in levelling studies
Zastosowanie wybranych testów statystycznych w badaniach pomiarów wysokościowych.
Autorzy:
Czempas, T.
Godek, K.
Krupiński, W.
Powiązania:
https://bibliotekanauki.pl/articles/100641.pdf
Data publikacji:
2018
Wydawca:
Uniwersytet Rolniczy im. Hugona Kołłątaja w Krakowie
Tematy:
mathematical statistics
statistical tests
analysis of measurement accuracy
precise levelling
statystyka matematyczna
niwelacja precyzyjna
dokładność pomiarowa
analiza dokładności pomiarowej
Opis:
The following paper presents a comparative application of three selected tests (L’Abbé’s, Kolmogorov’s, and Kuiper’s) in order to verify the normality of the distribution of measurement errors in precise levelling. The calculations were made on the basis of observations obtained from the levelling test network, established at the LZD experimental station in Krynica. The tests subjected to the comparison have demonstrated that the distribution of error in the studied tests is a normal distribution, and that there are no systematic errors in the measurements.
Poniższa praca przedstawia porównanie wykorzystania trzech wybranych testów (Abbe`go, Kołmogorowa i Kuipera) w celu sprawdzenia normalności rozkładu błędów pomiarowych w niwelacji precyzyjnej. Obliczeń dokonano na podstawie obserwacji uzyskanych z testowej sieci niwelacyjnej założonej w LZD Krynica. Porównane testy wykazały, że rozkład w błędu w badanych testach jest rozkładem normalnym, oraz, że nie występują błędy systematyczne w pomiarach.
Źródło:
Geomatics, Landmanagement and Landscape; 2018, 4; 7-15
2300-1496
Pojawia się w:
Geomatics, Landmanagement and Landscape
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Usefulness assessment of standard measuring instruments installed on sea-going ships to perform energy measurements
Autorzy:
Górski, Z.
Cwilewicz, R.
Powiązania:
https://bibliotekanauki.pl/articles/260338.pdf
Data publikacji:
2007
Wydawca:
Politechnika Gdańska. Wydział Inżynierii Mechanicznej i Okrętownictwa
Tematy:
standard measurement instrumentation
ships
accuracy of measurements
Opis:
The presented work is a contribution to discussion on usefulness of application of measurement instrumentation used on sea-going ships for energy measurement and scientific research purposes. Contemporary sea-going ships are equipped as a rule with up-to-date measurement instrumentation usually based on electronic data processing and computer technique. These authors have made many times use of such instruments in their research work. This way it was not necessary to install any special instruments, that significantly reduced measurement cost. In such cases to obtain a sufficient accuracy of measurements constitutes a crucial problem. In this paper was presented an analysis of measurement errors of some operational parameters of ship and its main propulsion system, elaborated within the frame of the KBN research project no. 9 T12D 033 17. Results of the analysis confirm usefulness of the standard measurement instrumentation installed on ships, and its sufficient accuracy.
Źródło:
Polish Maritime Research; 2007, 1; 23-27
1233-2585
Pojawia się w:
Polish Maritime Research
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Dokładność rozdrabniania liści mięty pieprzowej
Accuracy of grinding of peppermint leaves
Autorzy:
Flizikowski, J.
Taranowska, U.
Powiązania:
https://bibliotekanauki.pl/articles/2073134.pdf
Data publikacji:
2016
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
rozdrabnianie ziół
dokładność pomiaru
grinding of herbs
measurement accuracy
Opis:
Sprawdzono możliwości realizacji nowego procesu i określono dokładności wybranych charakterystyk rozdrabniania mięty pieprzowej. Rozdrabnianie przeprowadzono w rozdrabniaczu wielotarczowym produkcji ZBPP w Bydgoszczy. Gromadzenie, analizę i przetwarzanie danych na wskaźniki stanów zrealizowano w środowisku oprogramowania LabVIEW.
The feasibility of new process and determination of accuracy of selected grinding characteristics of peppermint were checked. The shredding was performed in the disengaged chipper made by ZBPP in Bydgoszcz. The collection, analysis and processing of data into state indicators were performed in the LabVIEW software environment.
Źródło:
Inżynieria i Aparatura Chemiczna; 2016, 4; 132--133
0368-0827
Pojawia się w:
Inżynieria i Aparatura Chemiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Programowe zwiększenie dokładności wykonania przedmiotu na obrabiarce NC
Software implementation of increasing the accuracy of the worpiece produced on the CNC machine tool
Autorzy:
Chrzanowski, J.
Powiązania:
https://bibliotekanauki.pl/articles/270121.pdf
Data publikacji:
2012
Wydawca:
Wrocławska Rada Federacji Stowarzyszeń Naukowo-Technicznych
Tematy:
dokładność obróbki
CAM
pomiary dokładności
CNC
accuracy of machining
computer-aided manufacturing*
measurement accuracy
Opis:
Systemy komputerowego wspomagania wytwarzania oraz obrabiarki sterowane numerycznie otworzyły możliwości programowego wpływania na dokładność wymiarową wytwarzanych przedmiotów. Możliwe stało się osiągnięcie wysokiej wymaganej dokładności wykonania nawet na obrabiarce, która nie spełnia wymogów stawianych w normach dotyczących badania obrabiarek. W niniejszym artykule opisano metody i sposoby programowych modyfikacji, dokonywanych w trakcie procesu projektowania obróbki, zwiększające dokładność wykonania przedmiotu. Opisano również zagadnienia związane z niedokładnością obrabiarki w funkcji prędkości posuwu oraz metodę korekcji tej niedokładności.
Computer-aided manufacturing and CNC machine tools have opened the possibility of the program influencing on the dimensional accuracy of manufactured products. It became possible to achieve high accuracy required for the implementation of even the machine that does not meet the requirements of the standards for testing machine tool. This article describes the methods and ways for software modifications made during the design process, increasing the accuracy of the workpiece. It also describes the issues related to the inaccuracy of the machine as a function of feed rate and method of correction this inaccuracies.
Źródło:
Inżynieria Maszyn; 2012, R. 17, z. 2; 19-30
1426-708X
Pojawia się w:
Inżynieria Maszyn
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Opisy dokładności układu oczka 4R zasilanego klasycznie oraz dwuprądowo jako przetwornika rezystancji w pomiarach dwuparametrowych (2D)
Description of the accuracy of conventional and double current supplied 4R mesh circuit as resistance converter in 2D measurements
Autorzy:
Warsza, Z. L.
Idźkowski, A.
Powiązania:
https://bibliotekanauki.pl/articles/156757.pdf
Data publikacji:
2014
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
przetwornik
mostek rezystancyjny
błąd pomiaru
niepewność pomiaru
converter
resistance bridge
accuracy
error of measurement
uncertainty of measurement
Opis:
Rozpatrzono zastosowania układu czterech rezystancji (4R) połączonych w oczko w pomiarach dwuparametrowych (2D) jako przetwornika różnych kombinacji przyrostów tych rezystancji na dwa napięcia wyjściowe, jako odchyłowego mostka sensorowego przy zasilaniu klasycznym, prądowym lub napięciowym oraz przy zasilaniu niekonwencjonalnym dwuprądowym - równolegle do ramion przeciwległych. Podano zracjonalizowane iloczynowe postacie funkcji rozwarciowych współczynników przetwarzania tych układów oraz wzory dla propagacji ich błędów przy dowolnych przyrostach rezystancji ramion układu z wyodrębnieniem składników dla stanu początkowego i dla funkcji przetwarzania. Jako przykład, przy obu rodzajach zasilania prądowego układu 4R o jednakowych rezystancjach początkowych, przedstawiono i porównano przebiegi funkcji błędów granicznych dla względnych zmian dwu sąsiednich rezystancji.
The single mesh circuit of arbitrary variable four arm resistances (4R), as primary converter of different combinations of their increments to two output voltages is considered. This 4R circuit can be supplied conventionally from current or voltage source as the deflection sensor bridge or supplied unconventionally by two current sources parallel to opposite arms. Functions of circuit transfer coefficients in 2D measurements by both type of supply and input resistance in rationalized forms for the unloaded outputs are given. Their error propagation formulas and limit errors in rationalized double component forms for zero error and increment error are find. As the example, limit errors of 4R circuit of similar initial resistances and of two arbitrary changed adjacent arms as functions of related resistance increments for both types of current supply, are presented in figures and compared.
Źródło:
Pomiary Automatyka Kontrola; 2014, R. 60, nr 11, 11; 1002-1005
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies