Wyszukujesz frazę "Portland cement dust" wg kryterium: Temat


Wyświetlanie 1-3 z 3
Tytuł:
A study on respiratory problems and pulmonary function indexes among cement industry workers in Mashhad, Iran
Analiza problemów ze strony układu oddechowego oraz wskaźników wydolności płuc wśród pracowników przemysłu cementowego w Mashhad w Iranie
Autorzy:
Rafeemanesh, Ehsan
Alizadeh, Ashkan
Afshari Saleh, Lahya
Zakeri, Hosein
Powiązania:
https://bibliotekanauki.pl/articles/2164430.pdf
Data publikacji:
2015-09-14
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
narażenie zawodowe
objawy oddechowe
test wydolności płuc
pył z cementu portlandzkiego
Iran
choroby zawodowe
occupational exposure
respiratory symptoms
pulmonary function test
Portland cement dust
occupational diseases
Opis:
Background The respiratory system is the most vulnerable system in the cement industry. This study was conducted to determine the effects of occupational exposure to cement dust on the respiratory system more thoroughly. Material and Methods In this cross sectional study an interviewer-administered questionnaire on socio-demographic characteristics and respiratory symptoms was completed and pulmonary function tests were carried out on 100 exposed and 120 non-exposed workers at the cement factory in Mashhad, Iran. The data was statistically analyzed by SPSS 16. Results The mean of age and work duration in the exposed group was 37.5±6.3 and 10.7±5.4 years compared with the non-exposed group that was 36.1±7.1 and 10.1±5.7 years, respectively. Levels of exposure to inhalable cement dust in the exposed group were 23.13 mg/m³ (higher than national occupational exposure limits for such particles). Among the exposed group, respiratory symptoms as cough (6% vs. 0.8% of the non-exposed) and sputum (7% vs. 0.8% of the nonexposed) were significantly more prevalent (p < 0.05). Forced expiratory flow 25–75% (FEF25–75%) was significantly lower in the exposed workers compared with non-exposed ones (p < 0.05). Also forced expiratory volume in 1 s / forced vital capacity (FEV₁/FVC) and FEF25–75% had a reverse correlation with the length of employment (p = 0.000 and p = 0.003, respectively). Conclusions The findings of this study showed that occupational exposure to cement dust could be a significant factor of respiratory system dysfunction. Strict implementation of a respiratory protection program is recommended in cement industries. Med Pr 2015;66(4):471–477
Wstęp Układ oddechowy jest tym najbardziej narażonym w przypadku pracy w przemyśle cementowym. Poniższe badanie miało na celu precyzyjne określenie wpływu na układ oddechowy narażenia zawodowego na pył cementowy. Materiał i metody W ramach analizy przekrojowej 100 narażonych oraz 120 nienarażonych na pył pracowników fabryki cementu w Mashhad w Iranie wypełniło kwestionariusz na temat cech społeczno-demograficznych oraz objawów oddechowych, a także poddało się testom wydolności płuc. Otrzymane dane zostały przeanalizowane statystycznie za pomocą SPSS 16. Wyniki Średnia wieku oraz czas zatrudnienia dla grupy badanej wyniosły odpowiednio 37,5±6,3 roku oraz 10,7±5,4 roku, a dla grupy porównawczej 36,1±7,1 roku oraz 10,1±5,7 roku. Poziom narażenia na działanie wdychanego pyłu cementowego w grupie badanej wyniósł 23,13 mg/m³ i przekraczał dozwoloną krajową normę narażenia zawodowego na te cząstki. W grupie badanej takie objawy oddechowe, jak kaszel (6% vs 0,8% w grupie porównawczej) i plwocina (7% vs 0,8%) znacznie przeważały nad innymi (p < 0,05). Wymuszony przepływ wydechowy 25–75% (FEF25–75%) odnotowano na znacznie niższym poziomie w przypadku narażonych pracowników w porównaniu do tych nienarażonych (p < 0,05). Także stosunek natężonej objętości wydechowej pierwszosekundowej do natężonej pojemności życiowej (FEV₁/FVC) oraz FEF25–75% wskazywały na odwrotną korelację z długością zatrudnienia (odpowiednio: p = 0,000 i p = 0,003). Wnioski Narażenie zawodowe na pył cementowy może być ważnym czynnikiem powodującym dysfunkcję układu oddechowego. Ścisłe przestrzeganie programu ochrony układu oddechowego jest zalecane w przemyśle cementowym. Med. Pr. 2015;66(4):471–477
Źródło:
Medycyna Pracy; 2015, 66, 4; 471-477
0465-5893
2353-1339
Pojawia się w:
Medycyna Pracy
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The development of an ecofriendly binder containing high volume of cement replacement by incorporating two by-product materials for the use in soil stabilization
Autorzy:
Jafer, Hassnen
Jawad, Ibtehaj
Majeed, Zaid
Shubbar, Ali
Powiązania:
https://bibliotekanauki.pl/articles/35522654.pdf
Data publikacji:
2021
Wydawca:
Szkoła Główna Gospodarstwa Wiejskiego w Warszawie. Wydawnictwo Szkoły Głównej Gospodarstwa Wiejskiego w Warszawie
Tematy:
soil stabilization
eco-friendly binder
ordinary Portland cement
ground granulated blast furnace slag
cement kiln dust
cement replacement
Opis:
The development of an ecofriendly binder containing high volume of cement replacement by incorporating two waste materials for the use in soil stabilization. This paper investigates the possibility of replacing ordinary Portland cement (OPC) by two waste and by-product materials for the use of a silty clay soil stabilization purpose. The soil was treated by 9.0% OPC where this mixture was used as a reference for all tests. Two by-product materials: ground granulated blast furnace slag and cement kiln dust were used as replacement materials. Consistency limits, compaction and unconfined compression strength (UCS) tests were conducted. Scanning electron microscopy (SEM) analysis was carried out for the proposed binder to investigate the reaction of products over curing time. Seven curing periods were adopted for all mixtures; 1, 3, 7, 14, 28, 52, and 90 days. The results showed that the strength development over curing periods after cement replacement up to 45–60% was closed to those of the reference specimens. The microphotographs of SEM analysis showed that the formation of Ettringite and Portladite as well as to calcium silicate hydrate gel was obvious at curing periods longer than 7 days reflected that the replacing materials succeed to produce the main products necessary for binder formation.
Źródło:
Scientific Review Engineering and Environmental Sciences; 2021, 30, 1; 62-74
1732-9353
Pojawia się w:
Scientific Review Engineering and Environmental Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wodoodporność recyklowanej podbudowy z asfaltem spienionym w aspekcie składu spoiwa drogowego
The water resistance of a recycled base with foamed bitumen in the aspect of road binder composition
Autorzy:
Buczyński, P.
Iwański, M.
Mazurek, G.
Powiązania:
https://bibliotekanauki.pl/articles/391058.pdf
Data publikacji:
2016
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Tematy:
spoiwa drogowe
recykling głęboki
asfalt spieniony
wapno hydratyzowane
cement portlandzki
pyły cementowe
podbudowa recyklowana
hydraulic road binder
cold deep recycling
foamed bitumen
hydrated lime
Portland cement
cement dust
recycled base
Opis:
W referacie przedstawiono rezultaty badań recyklowanej podbudowy wykonanej w technologii recyklingu głębokiego na zimno z asfaltem spienionym oraz spoiwem mieszanym. W badaniach szczególną uwagę zwrócono na jej wodoodporność. Indywidualne projektowanie składu spoiwa pozwala na precyzyjne dostosowanie jego oddziaływania do warunków terenowych oraz wymaganych parametrów recyklowanej podbudowy. Projekt recyklowanej podbudowy z asfaltem spienionym symulował proces recyklingu głębokiego na zimno. Zastosowane składniki mineralne tj. destrukt asfaltowy, kruszywo 0/31,5 mm oraz kruszywo doziarniające 0/4 stanowiły materiał odpadowy z istniejącej konstrukcji. W składzie recyklowanej podbudowy zastosowano spoiwa drogowe, które wytworzono w warunkach laboratoryjnych z wymieszania trzech bazowych składników. Udział procentowy poszczególnych spoiw drogowych określono zgodnych z planem eksperymentu sympleksowo-centroidowego. Na podstawie uzyskanych wyników badań stwierdzono różnorodny wpływ analizowanych składników spoiw drogowych na właściwości mechaniczne oraz wodoodporność recyklowanej podbudowy. W oparciu o zastosowany plan eksperymentu możliwe było określenie składu spoiwa drogowego, które zapewni uzyskanie recyklowanej podbudowy odpornej na działanie wody.
The paper describes research results of recycled base which was performed in a cold deep recycling technology with foamed bitumen and different type of hydraulic mixed binder in the aspect of water resistance. An individual design of a composition of a binder enables to achieve a precise adjustment of a binder’s impact to local conditions and required parameters of a recycled base. The design a recycled base with foamed bitumen simulated a cold deep recycling process with materials from existing crushed bituminous pavement layers ("technology in-situ"). To produce the foamed bitumen a road bitumen of penetration grade 50/70 was used. Moreover, the following mineral components were categorised as a waste material: reclaimed asphalt pavement, 0/31,5 mm aggregate and aggregates for soil gradation improvement 0/4. A composition of the recycled base consisted of the binders prepared in the laboratory as a result of a mix of three basic components. The percentage of individual road binders was determined in line with the plan of the simlex-centroid experiment. For the purpose of determining an influence of such a hydraulic road binder on the water resistance in recycled base, the following tests were carried out: void contents Vm, tensile strength ratio TSR (water resistance). Additionally, an evaluation of increase of indirect tensile modulus (IT-CY) was conducted. On the basis of the test results, a varied impacts of tested hydraulic road binders on mechanical properties and water resistence of recycled base with foamed bitumen were observed. On the basis of the plan of the experiment, it was possible to determine the recommended road binder composition that enabled to obtain the water resistance in the recycled base with foamed bitumen.
Źródło:
Budownictwo i Architektura; 2016, 15, 1; 19-29
1899-0665
Pojawia się w:
Budownictwo i Architektura
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-3 z 3

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies