Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Coliform" wg kryterium: Temat


Tytuł:
Effect of heat treatment on microbiological and keeping quality of milk stored at 4°C±2°C
Wpływ obróbki termicznej mleka na jego jakość mikrobiologiczną i trwałość podczas przechowywania w temp. 4°C±2°C
Autorzy:
Molska, I.
Zmarlicki, S.
Konarzewska, G.
Janicki, A.
Powiązania:
https://bibliotekanauki.pl/articles/1399527.pdf
Data publikacji:
1989
Wydawca:
Instytut Rozrodu Zwierząt i Badań Żywności Polskiej Akademii Nauk w Olsztynie
Tematy:
milk thermization
coliform bacteria
psychrotrophs
Opis:
The heating of milk at 65, 69 and 72°C for 15 s destroyed 85.2, 91.2 and 94.0% of psychrotrophic bacteria, respectively, and reduced total bacteria number by 74.4, 78.4 and 86.3%, respectively. Coliform bacteria were destroyed so effectively, that none was found in 0.1 cm³ of milk heated at any of the applied temperature. Thermization at 65°C for 15 s extended the keeping quality of milk to three day at 4°C ± 2°C.
Mleko zbiorcze z gospodarstwa doświadczalnego SGGW-AR oraz z punktu skupu poddawano obróbce termicznej w temp. 65°C 69°C i 72°C przez 15 s w laboratoryjnym aparacie płytowym. Częśćmleka surowego jak i poddanego obróbce termicznej przechowywano następnie w temp. 4°C + 2°C w ciągu 3 dni. Po czasie 0, 24, 48 i 72 h mleko poddawano analizie, głównie mikrobiologicznej. Stwierdzono że stosowane warianty obróbki termicznej mleka nie różniły się pomiędzy sobą statystycznie istotnie pod względem zniszczenia bakterii ogółem i psychrotrofowych. W mleku poddanym stosowanym wariantom obróbki cieplnej stopień zanieczyszczenia bakterii ogółem wynosił odpowiednio 74,4% 78,4% i 86,3%, zaś bakterii psychrotrofowych 85,2%, 91,2% i 94,0%. Bakterie z grupy coli uległy zniszczeniu w takim stopniu, że były nieobecne w 0,1 cm³ ogrzewanego w różnej temperaturze i przechowywanego mleka. Dynamika przyrostu ogólnej liczby bakterii była w czasie przechowywania mleka ogrzewanego 9-krotnie niższa a psychrotrofów ok. 16-krotnie niższa niż w mleku surowym. Termizacja mleka (o średniej jakości mikrobiologicznej) w temp. 65°C/15 s pozwoliła na przedłużenie jego trwałości na okres co najmniej 3 dni w temp. 4°C + 2°C, dzięki zniszczeniu znacznej części zawartych w nim bakterii.
Źródło:
Acta Alimentaria Polonica; 1989, 15(39), 1; 25-34
0137-1495
Pojawia się w:
Acta Alimentaria Polonica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Antibiotic resistance of fecal coliform bacteria inhabiting sea water and sand of marine recreation beach in the southern Baltic Sea
Antybiotykooporność bakterii kałowych z grupy coli zasiedlających wodę morską i piasek rekreacyjnej plaży na obszarze Bałtyku Południowego
Autorzy:
Mudryk, Z.J.
Perlinski, P.
Robak, D.
Powiązania:
https://bibliotekanauki.pl/articles/84879.pdf
Data publikacji:
2016
Wydawca:
Akademia Pomorska w Słupsku
Tematy:
antibiotic resistance
fecal coliform bacteria
sea water
sand
sea beach
recreation beach
Baltic Sea
coliform bacteria
Opis:
The results of the present study showed variability in resistance of FC bacteria isolated from beach sand and sea water against tested antibiotics. Enteric bacteria were the most resistant to clindamycin and penicillin while the most sensitive to ciprofloxacin, gentamycin, neomycin, rifampicin and streptomycin. Fecal coliform bacteria inhabiting sand were more resistant to nearly all tested antibiotics compared to bacteria isolated from sea water. The majority of bacteria inhabiting sea water and sand of the studied beach were resistant to only 1-4 antibiotics out of the 12 antibiotics tested. Fecal coliform bacteria isolated from Ustka beach were the most resistant to β-lactam and lincosamide antibiotics, while the most susceptible to aminoglycosides.
Badano oporność na antybiotyki bakterii fekalnych wyizolowanych z wody morskiej i piasku rekreacyjnej plaży znajdującej się na południowym wybrzeżu Morza Bałtyckiego. Uzyskane wyniki badań wykazały zmienność w oporności bakterii z grupy coli wyizolowanych z piasku i wody morskiej wobec badanych antybiotyków. Mikroorganizmy te były najbardziej odporne na penicylinę i klindamycynę, a najbardziej wrażliwe na ciprofloksacynę, gentamycynę, neomycynę, ryfampicyny i streptomycyny. Bakterie kałowe z grupy coli zasiedlające piasek były bardziej odporne na prawie wszystkie badane antybiotyki niż te izolowane z wody morskiej. Większość bakterii zasiedlających wodę morską i piasek badanej plaży była odporna na zaledwie 1-4 antybiotyków z 12 badanych. Bakterie kałowe z grupy coli izolowane na plaży w Ustce były najbardziej oporne na antybiotyki beta-laktamowe oraz linkozamidy, a najbardziej podatne na aminoglikozydy.
Źródło:
Baltic Coastal Zone. Journal of Ecology and Protection of the Coastline; 2016, 20
1643-0115
Pojawia się w:
Baltic Coastal Zone. Journal of Ecology and Protection of the Coastline
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Application of Membrane Bioreactor for Greywater Treatment
Autorzy:
Fikri, Elanda
Zulkarnain, Oryza Filial
Azizah, R.
Latif, Mohd Talib
Firmansyah, Yura Witsqa
Powiązania:
https://bibliotekanauki.pl/articles/24201755.pdf
Data publikacji:
2023
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
membrane bioreactor
wastewater
greywater
BOD
COD
total coliform
Opis:
Urban planning management should consider wastewater as a challenge. Wastewater, in this case, grey water, is full of dangerous contaminants and, at specific concentrations, can turn into a substance that affects the environment. The effluent of the released waste must therefore be managed to ensure that it complies with the government’s quality standard criteria. The membrane bioreactor (MBR) technology process produced waste effluents with low concentrations of biological oxygen demand (BOD5), chemical oxygen demand (COD), and total organic carbon (TOC), proving its higher efficiency as a biological processing stage. Total coliforms and E. coli are not present in processed products, detergents and total suspended solid (TSS) are effectively degraded. This is made possible by the considerably lower organic load; as a result, biomass accumulation slows and mixed liquor suspended solids (MLSS), which have low value, are produced. With the assistance of continuous airflow, and without the use of chemicals or backwashing, an ultrafiltration module (UF) with a membrane cut-off size small enough to be able to create a constant permeate flux during the grey water treatment process is necessary. Although processed grey water does not pass denitrification, all parameters linked to the quality of the effluent water exceed environmental quality criteria.
Źródło:
Journal of Ecological Engineering; 2023, 24, 6; 207--213
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Bacteriological Quality Assessment of Shallow Wells in Sabion Gari settlement of Girei Local Government Area of Adamawa State
Autorzy:
Mbahi, A. M.
Jafaru, M. I.
Onoshe, S.
Amos, P. I.
Powiązania:
https://bibliotekanauki.pl/articles/1112767.pdf
Data publikacji:
2018
Wydawca:
Przedsiębiorstwo Wydawnictw Naukowych Darwin / Scientific Publishing House DARWIN
Tematy:
Coliform
Escherichia
Klebsiella
Sabon Gari
Water
Opis:
Shallow well water is one of the major source of drinking water in Girei Local Government. In the Present study, the bacteriological quality and physico-chemical properties (pH and temperature) of water samples collected from selected shallow wells in the study area were assessed. Therein, the organisms isolated from the well water are Escherichia and Klebsiellaspp. The coliform count of the water sample collected from the wells as determined by most probable number method falls between 350-1800+ coliforms / 100m1, while the heterotropic bacteria from the sample were in the range of 7.2 × 103 - 2.88 × 104 cfu/ml. Moreover, the pH and temperature of the water falls around 5.5-7.1 and 15-21 °C, respectively. This study showed that the water samples obtained from wells in Sabon Gari are heavily contaminated with coliforms. This is of serious concern because of the association of the coliforms with pathogenic enterobacteriaceae.
Źródło:
World News of Natural Sciences; 2018, 17; 56-62
2543-5426
Pojawia się w:
World News of Natural Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The influence of nitrates addition to milk on chosen properties of cheese
Współzalezność między zróżnicowanym dodatkiem saletry do mleka, zawartością azotanów i azotynów w serze, jego jakością i liczebnością bakterii z grupy coli
Autorzy:
Płuta, A.
Zmarlicki, S.
Olech, B.
Budzyńska, B.
Gaweł, J.
Powiązania:
https://bibliotekanauki.pl/articles/1399523.pdf
Data publikacji:
1989
Wydawca:
Instytut Rozrodu Zwierząt i Badań Żywności Polskiej Akademii Nauk w Olsztynie
Tematy:
nitrates and nitrite
cheese ripening
coliform bacteria
Opis:
The nitrates content in cheese was proportional to the amount of saltpetre added to the milk and this relationship remained unchanged for a long time during cheese ripening if the number of coliform bacteria did not exceed 10³ g. The nitrates reduction rate was proportional to the number of coliform bacteria. The nitrites content grew (up to a point) with the increase of the number of these bacteria. The saltpetre addition to the milk reduced the multiplication rate of coliform bacteria in the cheese only when the milk used to produce the cheese was strongly contaminated with these bacteria. In such a case the advantageous effect of saltpetre on cheese quality was also apparent.
Wykonano cztery serie doświadczeń w których prowadzono wyrób sera edamskiego z różnym dodatkiem saletry do mleka, tj. 0,5, 10 i 20 g KNO₃ na 100 l mleka (po 3 wyroby w każdej serii). Mleko używane w serii 1, 2 i 4 pasteryzowano w temp. 74°C + 1 przez 10-15 s, zaś w serii 3 użyto do wyrobu mleko surowe. W serii nr 4 do mleka dodawano namnożoną hodowlę bakterii z grupy coli. Stwierdzono że szybkość rozkładu azotanów w serze zależy głównie od liczebności bakterii z grupy coli. Przy zawartości tych bakterii wynoszącej 10⁵-10⁶/g sera całkowity rozkład azotanów następował już po 2 tygodniach dojrzewania (przy dodatku 0,02% KNO₃ do mleka) podczas gdy w serach zawierających nie więcej niż 10³ bakterii/g nawet po 9 tygodniach spadek zawartości azotanów nie przekraczał 20-30% (rys. 2). Zawartość azotynów w serze w czasie dojrzewania w niewielkim stopniu zależna była od wielkości dodatku saletry do mleka serowarskiego natomiast wzrastała do pewnej granicy wraz ze wzrostem liczby bakterii z grupy coli. Przy bardzo dużej liczebności bakterii coli zanikają szybko zarówno azotany jak i azotyny. Nie stwierdzono wpływu dodatku saletry do mleka na liczebność bakterii z grupy coli w serze jeśli ich zawartość nie przekraczała 10⁵/g sera. Natomiast przy silnym zakażeniu mleka serowarskiego tymi bakteriami obserwuje się niższą ich zawartość w serze przy wyższym dodatku saletry do mleka (tab. 3 i 4). Nie stwierdzono różnic w ocenie organoleptycznej serów otrzymanych przy różnym dodatku saletry do mleka, jeśli liczebność bakterii z grupy coli była niższa niż 10⁵/g sera. Korzystny wpływ dodatku saletry do mleka na cechy organoleptyczne sera ujawnił się natomiast w przypadku serów silniej zakażonych ww. bakteriami.
Źródło:
Acta Alimentaria Polonica; 1989, 15(39), 1; 35-44
0137-1495
Pojawia się w:
Acta Alimentaria Polonica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of the coliform in the Wilga River (southern Poland)
Autorzy:
Greczek-Stachura, Magdalena
Zagata Leśnicka, Patrycja
Ślęczka, Mateusz
Powiązania:
https://bibliotekanauki.pl/articles/2182151.pdf
Data publikacji:
2016-12-31
Wydawca:
Uniwersytet Pedagogiczny im. Komisji Edukacji Narodowej w Krakowie
Tematy:
coliform
Escherichia coli
water contaminations
Wilga River
Opis:
Rzeka Wilga należy do najbardziej zanieczyszczonych rzek w Krakowie. Zanieczyszczenie tej rzeki wynika głównie z obecności obiektów przemysłowych w jej pobliżu. Analizy miana coli próbek wody pobranych w 16 miejscach (począwszy od źródła rzeki w Raciborsku aż do Podgórza w Krakowie) wzdłuż rzeki przeprowadzone zostały w 2014 roku. Analiza ta jest podstawową metodą służącą do wykazania obecności ścieków w ciekach wodnych i jest oparta na pojawieniu się pęcherzyka powietrza w rurce Durhama, co z kolei jest efektem fermentacji laktozy prowadzonej przez bakterie Escherichia coli. Wodę o największej czystości wykazano w środkowym biegu rzeki, gdzie zaobserwowano szybki nurt oraz brak zabudowań gospodarczych w pobliżu rzeki. Wodę złej jakości stwierdzono nawet przy źródle rzeki, gdzie miano coli wynosiło 0,1. Wilga wykazuje tendencję do samooczyszczania się, co można było zaobserwować na odcinkach: Janowice-Sygneczów-Gołkowice oraz Swoszowice-Łagiewniki. Rzeka ta wykazałaby sporą tendencję do samooczyszczania się w przypadku braku ścieków odprowadzanych w sposób pośredni i bezpośredni. Samooczyszczanie się rzek jest procesem długotrwałym, dlatego przy znacznym dopływie ścieków proces ten jest hamowany i przez to trudny do zaobserwowania.
Źródło:
Annales Universitatis Paedagogicae Cracoviensis Studia Naturae; 2016, 1; 190-195
2543-8832
2545-0999
Pojawia się w:
Annales Universitatis Paedagogicae Cracoviensis Studia Naturae
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Bacteriological quality assessment of two sources of water supplies in Mubi, North-eastern Nigeria
Autorzy:
Tula, M. Y.
Onyeje, G. A.
John, A.
Powiązania:
https://bibliotekanauki.pl/articles/1162572.pdf
Data publikacji:
2018
Wydawca:
Przedsiębiorstwo Wydawnictw Naukowych Darwin / Scientific Publishing House DARWIN
Tematy:
Bacteriological
Coliform
Heterotrophic plate count
Mubi
water supplies
Opis:
Water is essential for all life forms and the provision of safe drinking water to the populace cannot be overemphasized. This study examined the bacteriological quality of two sources of water supplies in Mubi, North-eastern Nigeria. A total of 72 water samples were analysed. These include 30 from 10 brands of sachet water and 42 from 21 boreholes in seven different wards of Mubi. Heterotrophic plate count (HPC) was determined by pour plate technique and the total coliform count was determined by 3-3-3 regimen using most probable number (MPN) technique. Escherichia coli and other isolates were identified by standard protocols. The mean HPC for both borehole and sachet water samples were variable and ranged from 3.3 × 102 – 4.7 × 104 cfu/ml for sachet water and 1.1 – 6.0 × 104 cfu/ml for borehole water samples. The HPC of borehole water samples were significantly higher than those of sachet water (P = 0.006). The results showed that the mean MPN index for sachet water samples from brand HCM, KGN, OYM and YNS were zero (0). Brand UDS had the highest mean MPN index (1966.7), while other brands had low mean MPN index that ranged from 3.0 -9.1. In the same vein, the mean MPN index of borehole water samples were high, variable and ranged from 3.7 – 1750. Statistically, the mean MPN index/100ml of borehole water samples were significantly higher than those of sachet water samples (P = 0.006). A total of 49 non-repetitive bacterial species were isolated from the two sources of water. These include E. coli (30), Enterobacter spp (3), P. aeruginosa (5) and Citrobacter spp (11). The distributions of bacterial isolates from the two sources of water showed that E. coli was detected in two brands of sachet water SDK and DYJ and 20 representative boreholes in all the locations, while other organisms were variably distributed. The presence of these organisms constitutes public health significance.
Źródło:
World Scientific News; 2018, 111; 100-110
2392-2192
Pojawia się w:
World Scientific News
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of Low-Frequency Ultrasound on the Disintegration of Coliform and Fecal Coliform Bacteria
Autorzy:
Hawrylik, Eliza
Butarewicz, Andrzej
Powiązania:
https://bibliotekanauki.pl/articles/1955566.pdf
Data publikacji:
2021
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
coliform bacteria
ultrasonic disintegration
low frequency ultrasound
treated wastewater
Opis:
Wastewater contains an abundance of pathogenic microorganisms, which, if they infiltrate into the environment, can cause many bacterial diseases. The lack of widespread use of the wastewater disinfection process raises more and more concerns about the sanitary quality of the wastewater leaving treatment plants. This article aimed to test the effectiveness of the ultrasonic disintegration process against coliform bacteria and fecal coliforms in the treated wastewater. The paper presents the research on the use of ultrasound with a frequency of 20 and 40 kHz, with a variable and constant operating mode of an ultrasonic cleaner. The obtained test results confirm the effectiveness of the applied method. In most of the analyzed cases, 25-minute sonication reduced the number of tested microorganisms by over 90% compared to the control sample. Ultrasonic disintegration can therefore be successfully used in municipal wastewater treatment plants. The use of ultrasound for disinfection can improve the sanitary safety of the wastewater discharged into water or soil.
Źródło:
Journal of Ecological Engineering; 2021, 22, 9; 192-197
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Microbiological characterization of vegetables and their rhizosphere soil in Eastern Poland
Autorzy:
Kłapeć, Teresa
Cholewa, Alicja
Cholewa, Grażyna
Dutkiewicz, Jacek
Wójcik-Fatla, Angelina
Powiązania:
https://bibliotekanauki.pl/articles/989616.pdf
Data publikacji:
2016
Wydawca:
Instytut Medycyny Wsi
Tematy:
microbiological quality
vegetables
soil
aerobic bacteria
enterobacteriaceae
coliform bacteria
salmonella
clostridium
perfringens
Opis:
The aim of this study was to investigate the bacteriological quality of 5 kinds of vegetables (lettuce, dill, radish, beetroot, carrot) and their rhizosphere soil, originating from conventional farms located in the Lublin Province of Eastern Poland. A total number of 35 samples of fresh vegetables (FV) taken immediately from soil, 35 samples of soil from rhizosphere of these vegetables (SR) and 35 samples of vegetables sold at retail in the markets in Lublin (VR) were examined. The samples were analysed for the content of: aerobic mesophilic bacteria (AMB) grown at 30 °C and 37 °C, Gram-negative bacteria of Enterobacteriaceae family, faecal coliform (FC) bacteria, Salmonella spp., and Clostridium perfringens. Median AMB values determined at 30 °C for FV, SR and VR were 5.27, 5.00, and 5.00 log10 CFU g-1, respectively, being significantly greater compared to those recorded at 37 °C. The exceeding of the threshold value of 6.0 log10 CFU g-1 proposed by Gelosa (1998) was noted only in 5 FV samples grown at 30 °C (14.3%), and in 3 FV samples grown at 37 °C (8.6%). The threshold value was never exceeded in SR and VR samples. Median concentrations of Enterobacteriaceae determined for FV, SR and VR were 4.03, 3.87, and 3.04 log10 CFU g-1, respectively. Eleven species of Enterobacteriaceae were identified in the FV, SR and VR samples. The percent of samples containing Escherichia coli was greatest for VR (22.9%), smaller for FV (17.1%) and smallest for SR (5.7%). The median concentrations of the faecal coliform bacteria (FC), determined by culture at 44oC, were low, amounting to 1.000 log10 CFU g-1 for FV and SR and 0.00 for VR. All examined vegetable and soil samples tested negative for the presence of Salmonella. The median concentrations of Clostridium perfringens were low, amounting to 0.00 log10 CFU g-1 for all categories of samples. This bacterium was relatively common in soil samples with the prevalence of 40.0%, but very rare in vegetable samples (occurring in 5.7% of FV and in none of VR samples). In conclusion, the results of the present study generally indicate that the microbiological quality of Polish vegetables grown on conventional farms is satisfactory and safe for consumers.
Źródło:
Annals of Agricultural and Environmental Medicine; 2016, 23, 4
1232-1966
Pojawia się w:
Annals of Agricultural and Environmental Medicine
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Optimization of Slow Sand Filtration for the Raw Municipal Wastewater Treatment by Using the Blood Cockle (Anadara granosa) Shell as an Alternative Filter Media through the Response Surface Methodology
Autorzy:
Fitriani, Nurina
Ni'matuzahroh
O'Marga, Timothy Tjahja Nugraha
Radin Mohamed, Radin Maya Saphira
Wahyudianto, Febri Eko
Imron, Muhammad Fauzul
Isnadina, Dwi Ratri Mitha
Soedjono, Eddy Setiadi
Powiązania:
https://bibliotekanauki.pl/articles/2105267.pdf
Data publikacji:
2022
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
domestic wastewater
response surface methodology
slow sand filter
total coliform
Opis:
This research aimed to investigate the optimum conditions of slow sand filter (SSF) media modification by using ground Anadara granosa shell waste and the effect of the ripening period on the total coliform (TC) removal efficiency. The response surface methodology with the central composite design was conducted with three factors, namely, seeding time (2–3 weeks), running time (0–20 days), type of SSF media (i.e., river sand, A. granosa shell, and their combination), as independent variables. The results showed that the ripening period factor interacted insignificantly by improving the TC removal efficiency due to short ripening time (p > 0.05). The optimum conditions of the SSF to achieve maximum TC removal efficiency (99.70 ± 21.50%) were as follows: combination media of river sand and ground A. granosa shell waste, 2.8 weeks (20 days) of ripening period, and 20 days of operation. In conclusion, the optimum operating parameters of the slow sand filter revealed that the combination of river sand and A. granosa shell as well as prolonged ripening and running times could increase the removal efficiency of TC. Hence, the A. granosa shell has good application potential as filter media to remove TC from the municipal wastewater.
Źródło:
Journal of Ecological Engineering; 2022, 23, 6; 100--111
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Effectiveness of Melt-Blown Filter Cartridge and UV-C Rays on the Reduction of Total Coliform and Water Hardness in Production Process Water
Autorzy:
Fikri, Elanda
Putri, Nursyifa Yuliani
Djuhriah, Nanny
Hanurawaty, Neneng Yetty
Khair, Amar Sharaf Eldin
Powiązania:
https://bibliotekanauki.pl/articles/2086408.pdf
Data publikacji:
2022
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
melt blown
filter cartridge
ultraviolet C
UVC
total coliform
water hardness
Opis:
Water is one of the humans’ basic needs that are essential in daily lives. The water use related to the production of the food processing industry must at least meet the quality standards required for drinking water. The Production process water is obtained from the artesian well that has been treated with a physical treatment process. The microbiological examination result of total Coliform is 8.6 MPN/100 ml meaning that it does not meet the quality standard requirements, which is 0 MPN/100 ml (The Minister of Health Regulation Number 492 of 2010, concerning Drinking Water Quality Requirements), it is necessary to treat the production process water using a Melt Blown Filter (MBF) and UV-C rays. The purpose of this study was to determine the differences in the variation of the 1, 3, and 5-micron of Melt Blown Filter cartridge 10” in reducing the amount of total Coliform, as well as the water hardness and their effect on disinfection using UV-C rays. The type of research used is experimental research with a pretest-posttest without control research design. There is a reduction in the average total Coliform after the treatment using a Melt Blown Filter, with a result of 1, 3, and 5-micron as 2.95 MPN /100ml, 3.61 MPB/100 ml, and 7.31 MPN/100 ml with a percentage reduction of 100%, 94.5%, and 82.4%, respectively. The average total Coliform using the Melt Blown Filter equipped with the UV-C rays treatment resulted in a reduction of 1, 3, and 5-micron as 2.95 MPN/100 ml, 3.95 MPN/100 ml, 8.88 MPN/100 ml respectively, with a reduction percentage of 100%, for each treatment. The data analysis for total coliform using the One-Way ANOVA test resulted in a pvalue of 0.001, the effective variation obtained is 1-micron MBF equipped with UV-C rays. The analysis of results pertaining to the water hardness data showed that the use of Melt Blown Filter could not reduce water hardness, but the UV-C rays could still be used accordingly. The data analysis for water hardness was performed using KruskalWallis with a p-value of 0.820, meaning that there are no differences in Melt Blown Filter variation on the results of total water hardness value.
Źródło:
Journal of Ecological Engineering; 2022, 23, 4; 181--190
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Integrated Assessment of Groundwater Pollution from the Landfill of Sewage Sludge
Autorzy:
Dregulo, Andrey Mikhailovich
Bobylev, Nikolai Gennadievich
Powiązania:
https://bibliotekanauki.pl/articles/1839551.pdf
Data publikacji:
2021
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
landfill
sewage sludge
groundwater
heavy metals
organic pollution
fecal coliform bacteria
Gulf of Finland
Opis:
The purpose of this study was to assess the groundwater contamination from a sewage sludge landfill. The analysis was carried out in 2017 in accordance with the requirements of the national legislation for monitoring landfills and priority pollutants. The samples of groundwater from the landfill were taken from 25 observation wells, from depths of 45–60 m. The status and dynamics of changes in the landfill groundwater quality were estimated according to the data from the groundwater observation wells of the city observation network with regard to the chemical composition of groundwater and national standards of groundwater quality. The forecast estimates of a low level of pollutants entering groundwater through the soils characterized by low filtration properties were not justified. The concentration of heavy metals in groundwater was within the following range: Fe > Mn > Zn > Al > Cu > Ni > Pb > Cd > Hg. The excess concentration of the nitrogen-containing pollutants was observed within the range from 1.5 to 76 (on average 10 times) above the background value. The organic contamination of landfill groundwater (COD) is 2–9 times and BOD5 – 1.5–3 times higher than the average background value of groundwater observation wells in the city network. The probable cause for the pollutants entry into groundwater is associated with lithogenous and exogenous fracturing of the rocks and insufficient efficiency of the existing anti-filtration system of the landfill.
Źródło:
Journal of Ecological Engineering; 2021, 22, 1; 68-75
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Motijheel Lake - Victim of Cultural Eutrophication
Autorzy:
Biswas, Manali
Mandal, Debjani
Sonar, Ritesh
Dey, Bipraprasad
Ghosh, Shrabana
Ghosh, Subhamoy
Chatterjee, Joeeta
Bhattacharyya, Bibhas
Saha, Indranil
Ahmed, Shamsuzzaman
Basu, Abhishek
Powiązania:
https://bibliotekanauki.pl/articles/1055277.pdf
Data publikacji:
2018
Wydawca:
Przedsiębiorstwo Wydawnictw Naukowych Darwin / Scientific Publishing House DARWIN
Tematy:
Carlson’s Trophic State Index
Coliform analysis
Dissolved Oxygen
Eutrophication
Motijheel Lake
Opis:
Destruction of natural water bodies due to cultural eutrophication is a predominant problem in India. Motijheel Lake of Murshidabad district is an environmentally, economically and historically significant water body. However, Anthropogenic activities including unplanned settlements around this lake and its over exploitation have deteriorated its water quality to a great extent. Motijheel Lake acts as a sink for domestic sewage, human and animal excreta. Surface runoffs are discharged into the lake which further adds to the list of pollutants. High phosphate, nitrate and nitrite-Nitrogen and chlorophyll content of the lake categorizes it as hypereutrophic one. Also, the amount of phosphate, nitrite and iron present in Motijheel Lake exceed the permissible limit in drinking water, as prescribed by US Environmental Protection Agency and Bureau of Indian Standards. When the Below Poverty Line residents of the surrounding area consume such water, they become susceptible to various fatal diseases. The low level of Dissolved Oxygen in the lake water signifies huge amount of organic matter deposited in the lake and indicates the lake water to be poor in quality. The high load of coliform bacteria in the lake water further corroborates the deposition of domestic, human and animal wastes. If water with such high concentration of faecal coliform is consumed, it could lead to fatal gastrointestinal and enteric diseases.
Źródło:
World News of Natural Sciences; 2018, 21; 154-163
2543-5426
Pojawia się w:
World News of Natural Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Detection of coliforms in drinking water and its effect on human health - a review
Autorzy:
Pal, P.
Powiązania:
https://bibliotekanauki.pl/articles/11602.pdf
Data publikacji:
2014
Wydawca:
Przedsiębiorstwo Wydawnictw Naukowych Darwin / Scientific Publishing House DARWIN
Tematy:
detection
coliform bacteria
drinking water
human health
Escherichia coli
water contamination
health hazard
public health
Opis:
The coliform group has been used extensively as an indicator of water quality and has historically led to the public health protection concept. Total coliforms are a group of bacteria commonly found in the environment, for example in soil or vegetation, as well as the intestines of mammals, including humans. Total coliform bacteria are not likely to cause illness, but their presence indicates that the water supply may be vulnerable to contamination by more harmful microorganisms. Escherichia coli (E. coli) is the only member of the total coliform group of bacteria that is found only in the intestines of mammals, including humans. The presence of E. coli in water indicates recent fecal contamination and may indicate the possible presence of disease-causing pathogens, such as bacteria, viruses, and parasites. Although most strains of E. coli bacteria are harmless, certain strains, such as E.coli 0157:H7, may cause illness. About 80 % of communicable diseases in the world are waterborne. According to WHO estimate about 80 % of water pollution in developing country, like India is carried by domestic waste. In India 70 % of the water is seriously polluted and 75 % of illness and 80 % of the child mortality is attributed to water pollution. The improper management of water systems may cause serious problems in availability and quality of water. The major pathogenic bacteria responsible for water borne disease are spread by the faeco-oral route, in which water may play an intermediate role. The aim of this review is to examine methods currently in use for the detection of coliforms in drinking water and also to evaluate the possible health hazards associated with drinking water contaminated with coliforms.
Źródło:
International Letters of Natural Sciences; 2014, 12, 2
2300-9675
Pojawia się w:
International Letters of Natural Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Microbial transport in soil caused by surface and subsurface drip irrigation with treated wastewater
Autorzy:
Kouznetsov, M.Y.
Pachepsky, Y.A.
Gillerman, L.
Gantzer, C.J.
Oron, G.
Powiązania:
https://bibliotekanauki.pl/articles/24290.pdf
Data publikacji:
2004
Wydawca:
Polska Akademia Nauk. Instytut Agrofizyki PAN
Tematy:
bacteriophage
subsurface drip irrigation
fecal coliform
waste water
surface drip irrigation
microbial transport
soil
irrigation
Źródło:
International Agrophysics; 2004, 18, 3
0236-8722
Pojawia się w:
International Agrophysics
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies