Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Wierszycki, M." wg kryterium: Autor


Wyświetlanie 1-4 z 4
Tytuł:
Numerical verification of two-component dental implant in the context of fatigue life for various load cases
Autorzy:
Szajek, K.
Wierszycki, M.
Powiązania:
https://bibliotekanauki.pl/articles/307214.pdf
Data publikacji:
2016
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
implant stomatologiczny
optymalizacja
trwałość zmęczeniowa
algorytm genetyczny
dental implant
optimization
fatigue life
genetic algorithm
Opis:
Purpose: Dental implant designing is a complex process which considers many limitations both biological and mechanical in nature. In earlier studies, a complete procedure for improvement of two-component dental implant was proposed. However, the optimization tasks carried out required assumption on representative load case, which raised doubts on optimality for the other load cases. This paper deals with verification of the optimal design in context of fatigue life and its main goal is to answer the question if the assumed load scenario (solely horizontal occlusal load) leads to the design which is also “safe” for oblique occlussal loads regardless the angle from an implant axis. Methods: The verification is carried out with series of finite element analyses for wide spectrum of physiologically justified loads. The design of experiment methodology with full factorial technique is utilized. All computations are done in Abaqus suite. Results: The maximal Mises stress and normalized effective stress amplitude for various load cases are discussed and compared with the assumed “safe” limit (equivalent of fatigue life for 5e6 cycles). Conclusions: The obtained results proof that coronial-appical load component should be taken into consideration in the two component dental implant when fatigue life is optimized. However, its influence in the analyzed case is small and does not change the fact that the fatigue life improvement is observed for all components within whole range of analyzed loads.
Źródło:
Acta of Bioengineering and Biomechanics; 2016, 18, 1; 103-113
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Optimization of dental implant using genetic algorithm
Optymalizacja wszczepu stomatologicznego z wykorzystaniem algorytmu genetycznego
Autorzy:
Łodygowski, T.
Szajek, K.
Wierszycki, M.
Powiązania:
https://bibliotekanauki.pl/articles/279418.pdf
Data publikacji:
2009
Wydawca:
Polskie Towarzystwo Mechaniki Teoretycznej i Stosowanej
Tematy:
design optimization
genetic algorithm
dental implant
Opis:
The subject of the present work is optimization of the modern implant system Osteoplant, which was created and is still developed by Foundation of University of Medical Sciences in Poznań. Clinical observations point to the occurrence of both early and late complications in the case of all two-component implant systems. In many cases, these problems are caused by mechanical fractures of the implants themselves. The obtained results of the previous studies focused on necessary changes of the implant mechanical behavior, which helped to achieve the required long-term strength. However, modifications of the present dental implant system are not obvious. In this paper, an optimization of the Osteoplant dental implant system, with the use of FEA and genetic algorithms is discussed.
Przedmiotem prezentowanej pracy jest problem optymalizacji systemu implantologicznego Osteoplant, który został opracowany i wciąż jest ulepszany przez Fundację Uniwersytetu Medycznego w Poznaniu. Obserwacje kliniczne potwierdzają występowanie powikłań zarówno we wczesnej, jak i późnej fazie użytkowania implantu. Dotychczas otrzymane wyniki wskazują, że wydłużenie bezawaryjnego okresu użytkowania implantu wymaga wprowadzenia zmian w jego pracy mechanicznej. Jednakże, ustalenie szczegłów modyfikacji nie jest oczywiste. W artykule została opisana procedura optymalizacji systemu implantologicznego Osteoplant z użyciem analizy metodą elementów skończonych oraz algorytmu genetycznego.
Źródło:
Journal of Theoretical and Applied Mechanics; 2009, 47, 3; 573-598
1429-2955
Pojawia się w:
Journal of Theoretical and Applied Mechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Numerical complexity of selected biomechanical problems
Numeryczna złożoność wybranych problemów biomechaniki
Autorzy:
Wierszycki, M.
Kąkol, W.
Łodygowski, T.
Powiązania:
https://bibliotekanauki.pl/articles/280688.pdf
Data publikacji:
2006
Wydawca:
Polskie Towarzystwo Mechaniki Teoretycznej i Stosowanej
Tematy:
biomechanika
trwałość implantów
sztywność segmentów kręgosłupa
biomechanical
finite element method
fatigue analysis
dental implant
spine segment
Opis:
The paper describes various aspects of numerical modeling of biomechanical problems by the finite element method. The authors would like to present what they mean by the numerical complexity of modeling of biomechanical problems. The attention is focused on numerical simulation of dental implants and human lumbar spine motion segment (L4-L5). In both cases, acquisition and creation of geometry, number of DOFs, combining different types of elements, properties of the material, contact definitions, loads and boundary conditions are difficult tasks. The acquisition of geometric data of living body parts can be realized only by using noninvasive techniques like NMR or CT. The processing of these data requires specialized software and methods. The methodologies of defining mechanical parameters of human tissues are usually inaccurate and have to be used in practice on living people very carefully. The constitutive data in literature are usually grossly inconsistent. In numerical simulations, custom material formulations and modeling techniques should be used. It is difficult to describe real-world loads and boundary conditions since both are very complex and changing. Load scheme models are global and force values are very difficult to obtain. Boundary conditions are necessarily very simplified but they should reflect specific biological behaviors and conditions. Nevertheless, the numerical simulation by means of the finite element method can be helpful and useful during solving biomechanical problems like fatigue analysis of dental implants or estimating the stiffness of human lumbar spine segment.
Praca opisuje wybrane aspekty modelowania numerycznego z wykorzystaniem Metody Elementów Skończonych (MES) zagadnień biomechaniki. Autorzy starają się podkreślić złożoność takiej analizy MES. Uwagę skupiono na dwóch przykładach: analizie wszczepu stomatologicznego oraz ruchomości segmentu kręgosłupa ludzkiego (L4-L5). W obu analizowanych i modelowanych przypadkach odtworzenie geometrii, liczba typów elementów i stopni swobody modeli, przyjęcie modeli i właściwości konstytutywnych materiałów biologicznych, definicje problemów kontaktowych czy warunków początkowo-brzegowych stanowią o poziomie trudności podejmowanych zadań. Pokonanie wymienionych trudności, a co za tym idzie zbudowanie modeli numerycznych odtwarzających zachowanie się rzeczywistych elementów biomechanicznych jest przedmiotem podejmowanej w pracy dyskusji. Pomimo tej złożonościzadań, zastosowanie MES do oceny zachowania się implantów bądź segmentu ruchowego prowadzi do wystarczająco zgodnej z eksperymentem oceny trwałości implantów lub sztywności segmentów kręgosłupa.
Źródło:
Journal of Theoretical and Applied Mechanics; 2006, 44, 4; 797-818
1429-2955
Pojawia się w:
Journal of Theoretical and Applied Mechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Experimental verification of two component implant optimization results in context of fatigue life
Weryfikacja eksperymentalna wytrzymałości zmęczeniowej zoptymalizowanego implantu stomatologicznego
Autorzy:
Szajek, K.
Wierszycki, M.
Topoliński, T.
Łodygowski, T.
Powiązania:
https://bibliotekanauki.pl/articles/301799.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Polskie Naukowo-Techniczne Towarzystwo Eksploatacyjne PAN
Tematy:
implant zębowy
optymalizacja
wytrzymałość zmęczeniowa
testy eksperymentalne wytrzymałości zmęczeniowej
dental implant
optimization
fatigue
experimental fatigue test
Opis:
W artykule przedstawiono weryfikację zoptymalizowanego implantu zębowego w kontekście wytrzymałości zmęczeniowej przy pomocy testów laboratoryjnych. Optymalne rozwiązanie otrzymano przy zastosowaniu modelu numerycznego metodą elementów skończonych oraz strategii łączącej algorytm genetyczny z procedurą Hooke-Jeeves. Dla projektu bazowego oraz ulepszonego rozwiązania przeprowadzono serię testów na maszynie Instron 8874 używając metody Locati przyśpieszonego badania zmęczeniowego. Prezentowane badania są weryfikacją efektywności przyjętej strategii optymalizacji. Z powodu zastosowanej metodologii badań eksperymentalnych, efekty optymalizacji poddano tylko porównaniu jakościowemu.
In this paper the verification of the optimal dental implant design is presented. It is focused on fatigue fracture and is carried out with experimental tests. The optimal design was obtained with an optimization strategy using finite element model and genetic algorithm hybridized with Hooke-Jeeves technique. The fatigue tests of the prototype and initial designs of dental implants have been performed on Instron 8874 testing system using Locati method of an accelerated fatigue testing. The presented studies are excepted to verified the effectiveness of optimization strategy. Due to used methodology for experimental verification only qualitative effects of the optimization are compared. The work is a part of long term project under the grant R13 0020 06 “Development and preparation of dental implant prototypes”.
Źródło:
Eksploatacja i Niezawodność; 2017, 19, 2; 166-171
1507-2711
Pojawia się w:
Eksploatacja i Niezawodność
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-4 z 4

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies