Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Polak, M." wg kryterium: Autor


Tytuł:
Fermented ethanol as a component of the rape-seed oil based diesel fuel
Bioetanol jako składnik paliwa (estru) produkowanego na bazie oleju rzepakowego
Autorzy:
Polak, M.
Powiązania:
https://bibliotekanauki.pl/articles/796068.pdf
Data publikacji:
2002
Wydawca:
Szkoła Główna Gospodarstwa Wiejskiego w Warszawie. Wydawnictwo Szkoły Głównej Gospodarstwa Wiejskiego w Warszawie
Opis:
The paper presents the practical results of the performance with the biodiesel and their mixtures with different quantity of fermented ethanol. The ZETOR trademark Czech agricultural tractor and the AVIA trademark Czech truck engines were used in the experiments. Based on the results, it can be said that the most suitable fuel blend is: biodiesel + 2% addition of fermented bioethanol according to following points. This addition significantly reduces the NOₓ emissions. In the AVIA engine the reduction is about 54% in comparison with non additived fuel (0% fuel blend). In the Zetor engine, it decreased by 88% of its primary value. Even in the case of smokiness, the situation is similarly favourable. The power output parameters are almost constant. No significant increase of fuel consumption was observed. However higher share of unburned hydrocarbons depending on increased alcohol content was observed. In with comparison to the commercially available petrol diesel, the total amount of emissions at the fuel blends (especially with small content of alcohol) was lower in all cases, which facilitates the realization of emission limits also in the older types of engines.
W artykule przedstawiono praktyczne wyniki stosowania do silników wysokoprężnych biopaliwa (bioetanol), przy różnej zawartości bioetanolu. W badaniach stosowano silniki wysokoprężne produkcji czeskiej ciężarówki AVIA i ciągnika ZETOR. Wyniki wskazują, że najbardziej odpowiednią mieszanką paliw było biopaliwo z 2% dodatkiem etanolu. Dodatek ten znacznie zmniejszał emisję NOₓ: w silniku AVIA o około 54%, w porównaniu z paliwem bez dodatków, natomiast w silniku ZETOR spadek wyniósł 88% w stosunku do wartości początkowej. Także w odniesieniu do dymienia zjawisko było podobnie korzystne. Parametry mocy silników były prawie stałe. Nie zaobserwowano znaczącego wzrostu zużycia paliwa, jednak zwiększał się udział nie spalonych węglowodorów w miarę wzrostu zawartości alkoholu. W porównaniu z dostępnym na rynku olejem napędowym, przy zastosowaniu mieszanek paliwowych (szczególnie przy niskiej zawartości alkoholu), całkowita emisja była niższa we wszystkich przypadkach, co ułatwia spełnienie wymagań dotyczących emisji w silnikach starszych typów.
Źródło:
Zeszyty Problemowe Postępów Nauk Rolniczych; 2002, 486, 2
0084-5477
Pojawia się w:
Zeszyty Problemowe Postępów Nauk Rolniczych
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ekonomiczna analiza produkcji energii z biomasy
Analysis of energy production from biomass
Autorzy:
Polak, M.
Powiązania:
https://bibliotekanauki.pl/articles/79210.pdf
Data publikacji:
2009
Wydawca:
Zachodniopomorski Uniwersytet Technologiczny w Szczecinie. Wydawnictwo Uczelniane ZUT w Szczecinie
Tematy:
biomasa
biogaz
produkcja energii
energia elektryczna
energia cieplna
analiza ekonomiczna
Opis:
The analysis of amount of the thermal and electric energy produced by utilizing one type of biomass and organic additions as well as the realization of economical analysis of conversion of primary energy of the batch to the end electric and thermal energy were the aim of this work. Investigations were conducted at the biogas production station Kapużany equipped with the cogeneration unit of 120 kW in power. As basic fermentative raw material maize was used besides liquid manure and dung that were used as additions. It was stated that with help of the applied cogeneration unit the acreage needed to maize cultivation was ca 70 ha. It is possible to produce 16 800−19 600 kWh of electricity and ca from 14 000 to 16 000 kWh of heat from 1 ha. The profit achieved from annual exploitation of the biogas station was 869 400 Sk.
Źródło:
Folia Pomeranae Universitatis Technologiae Stetinensis. Oeconomica; 2009, 57
2081-0644
Pojawia się w:
Folia Pomeranae Universitatis Technologiae Stetinensis. Oeconomica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Markery izoenzymowe w badaniach nad zroznicowaniem genetycznym populacji drzew lesnych. Czesc I. Technika i zakres zastosowan
Autorzy:
Polak, M.
Sabor, J.
Powiązania:
https://bibliotekanauki.pl/articles/817779.pdf
Data publikacji:
1997
Wydawca:
Polskie Towarzystwo Leśne
Tematy:
zroznicowanie genetyczne
zastosowanie
populacje roslin
lesnictwo
markery izoenzymatyczne
drzewa lesne
Źródło:
Sylwan; 1997, 141, 11; 49-57
0039-7660
Pojawia się w:
Sylwan
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Awifauna doliny Belnianki pod Daleszycami [woj.Swietokrzyskie] w okresie zimowania i przelotow w latach 1995-1996
Autorzy:
Wilniewczyc, P.
Polak, M.
Powiązania:
https://bibliotekanauki.pl/articles/32795.pdf
Data publikacji:
2002
Wydawca:
Mazowiecko-Świętokrzyskie Towarzystwo Ornitologiczne
Tematy:
awifauna
ptaki
Daleszyce
zimowanie zwierzat
przeloty ptakow
dolina Belnianki
Źródło:
Kulon; 2002, 07, 1-2; 41-72
1427-3098
Pojawia się w:
Kulon
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Algorithms for generation of Ramanujan graphs, other Expanders and related LDPC codes
Autorzy:
Polak, M.
Ustimenko, V.
Powiązania:
https://bibliotekanauki.pl/articles/106138.pdf
Data publikacji:
2015
Wydawca:
Uniwersytet Marii Curie-Skłodowskiej. Wydawnictwo Uniwersytetu Marii Curie-Skłodowskiej
Tematy:
Ramanujan graphs
LDPC codes
Opis:
Expander graphs are highly connected sparse finite graphs. The property of being an expander seems significant in many of these mathematical, computational and physical contexts. For practical applications it is very important to construct expander and Ramanujan graphs with given regularity and order. In general, constructions of the best expander graphs with a given regularity and order is no easy task. In this paper we present algorithms for generation of Ramanujan graphs and other expanders. We describe properties of obtained graphs in comparison to previously known results. We present a method to obtain a new examples of irregular LDPC codes based on described graphs and we briefly describe properties of this codes.
Źródło:
Annales Universitatis Mariae Curie-Skłodowska. Sectio AI, Informatica; 2015, 15, 2; 14-21
1732-1360
2083-3628
Pojawia się w:
Annales Universitatis Mariae Curie-Skłodowska. Sectio AI, Informatica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
LDPC codes based on algebraic graphs
Autorzy:
Polak, M.
Ustimenko, V.
Powiązania:
https://bibliotekanauki.pl/articles/106289.pdf
Data publikacji:
2012
Wydawca:
Uniwersytet Marii Curie-Skłodowskiej. Wydawnictwo Uniwersytetu Marii Curie-Skłodowskiej
Tematy:
algebraic graph
LDPC codes
MAP decoder
Opis:
In this paper we investigate correcting properties of LDPC codes obtained from families of algebraic graphs. The graphs considered in this article come from the infinite incidence structure. We describe how to construct these codes, choose the parameters and present several simulations, done by using the MAP decoder. We describe how error correcting properties are dependent on the graph structure. We compare our results with the currently used codes, obtained by Guinand and Lodge [1] from the family of graphs D(k; q), which were constructed by Ustimenko and Lazebnik [2].
Źródło:
Annales Universitatis Mariae Curie-Skłodowska. Sectio AI, Informatica; 2012, 12, 3; 107-119
1732-1360
2083-3628
Pojawia się w:
Annales Universitatis Mariae Curie-Skłodowska. Sectio AI, Informatica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The optimisation of biomass combustion in small boilers
Autorzy:
Polak, M.
Neuberger, P.
Powiązania:
https://bibliotekanauki.pl/articles/59899.pdf
Data publikacji:
2008
Wydawca:
Polska Akademia Nauk. Stowarzyszenie Infrastruktura i Ekologia Terenów Wiejskich PAN
Tematy:
optimization
biomass combustion
small boiler
boiler
power generation
heat generation
biofuel
Opis:
Biomass contains chemical energy which is a transformed Sun radiation. This energy can be used in many different ways. One of these is a direct combustion which is the most popular. The direct combustion of biomass is a technology which is well proven in large-scale heat and power generation. However, the situation in the small-scale heat generation is not so good. This paper describes results from the experimental combustion with various kinds of biomass in three different combustion devices. Saw dust is used in the experiment described below. The aim is to choose the best biofuel modification and the best way for its combustion from the point of view of power and emission parameters. As for the so far reached results of the experiment, the best in case of saw dust is the combustion with gasification of saw dust briquettes on stable grate without primary air or pellets in bottom supplied burner.
Źródło:
Infrastruktura i Ekologia Terenów Wiejskich; 2008, 06
1732-5587
Pojawia się w:
Infrastruktura i Ekologia Terenów Wiejskich
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Manganese oxides from Zalas, Kraków area, southern Poland
Autorzy:
Polak, M.
Gołębiowska, B.
Rzepa, G.
Powiązania:
https://bibliotekanauki.pl/articles/184692.pdf
Data publikacji:
2016
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
intrusion
volcanic rock
limestone
Opis:
The Zalas quarry is located in the southern, marginal part of the Silesian-Cracovian Monocline. Permian rhyodacite laccolith has been exploited here for over 70 years. The intrusion was formed about 260–280 Ma during the Early Permian transtensional, sinistral tectonic regime predominating in central Europe at that time (Nawrocki et al. 2005). Permian volcanic rocks are overlain by a Middle–Upper Jurassic sedimentary sequence, built from sands and sandstones, substituted with the passing of time by limestones and sandy limestones rich in fossils (Matyszkiewicz et al. 2006). Quarrying operations carried out approximately 10 years ago uncovered a fault zone cutting the Middle Jurassic sandy limestones. Exposed breccias was locally encrusted by a hydrothermal mineralization forming thin veinlets cutting the limestone, or surrounding the breccia clasts. Primary mineralization contained small relics of pyrite, chalcopyrite, chalcocite, galena, native bismuth and barite and was significantly replaced by supergene minerals e.g. Fe and Mn oxides, malachite, cuprite, Cu sulphates, iodargyrite, Bi oxychlorides and Na, K chlorides (Gołębiowska et al. 2006, 2010, 2015). The mineralization is most likely connected with rejuvenation of Early-Paleozoic fault zones during the Sava phase of the Alpine orogeny, and subsequent intensive weathering under semi-arid and arid climate in a period between the Oligocene and Middle Miocene (Gołębiowska et al. 2010). In the sandy limestone encrusted by the oxidized mineralization, very interesting Mn-oxides, enriched in numerous heavy metals were encountered. They filled small fractures and voids within the fault breccia. Among them, Tl-rich varieties have been recently reported. Extremely high thallium content, reaching 20.82 wt% Tl 2 O, makes the oxides unique on a world scale (Gołębiowska et al. 2015). In this paper we focused on the variable admixtures in Mn oxides from oxidation zone in Zalas; for this purpose, SEM-EDS and WDS analyses were carried out. Mn oxides in Zalas are accompanied by malachite, Fe oxides (goethite and hematite) and relics of primary mineralization (Matyszkiewicz et al. 2015). Mn and Fe oxides commonly form the yellowish to red-brownish or black tiny grains or cryptocrystalline aggregates with sizes up to a few millimetres across. Manganese oxides contain variable admixtures of Cu, Ca, Pb, Ba, Fe, Ni, Co and Tl. On the basis of chemical analyses, three major Mn oxide types have been distinguished: those enriched in (i) Ni and Co, (ii) Pb and (iii) Ba and Ca. Co-Ni-bearing Mn oxides, probably asbolane-type, contain 17.01–21.58 wt% CoO and 3.05–8.33 wt% NiO. These phases contain also admixtures of Cu (up to 10 wt% CuO) and Al (up to 7 wt% of Al 2 O 3 ), as well as traces of Fe, Ba, Zn, Mg and Tl (up to 0.5 wt%). Interestingly, in Mn oxides of this type, the admixtures of lead are absent. Pb-bearing Mn oxide, probably coronadite, contain up to 21.48 wt% PbO. In its composition various other elements were also noticed: up to 2 wt% CoO, 0.4 wt% NiO and very high concentrations of CuO up to 8 wt%, as well as up to 1 wt% BaO, FeO, CaO Tl 2 O, Al 2 O 3 and traces of Zn and Mg. Chemical mapping indicates that the Ba- or Ca-bearing Mn oxides occur only in marginal parts of zoned MnO 2 aggregates with almost pure MnO 2 in their cores. They contain 78–84 wt% MnO 2, 3–10 wt% BaO and 2.5–4.5 wt% CaO. High contents of Co, Ni, Pb, Cu and Tl in Mn oxides from Zalas indicate a direct link with the primary ore assemblage. High concentration of cobalt and nickel might suggest some connection with Co and Ni mineralization known from nearby Karniowice Travertine (Czerny 1992). Mineral association, as well as crystal morphologies and sizes could indicate hydrothermal origin of at least part of the Mn oxides. However, identification of the particular minerals as well as concluding on the details of their origin is quite difficult on this stage of research.
Źródło:
Geology, Geophysics and Environment; 2016, 42, 1; 120-121
2299-8004
2353-0790
Pojawia się w:
Geology, Geophysics and Environment
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ recyrkulacji spalin na proces spalania biomasy
Effect of combustion gas recirculation on biomass burning process
Autorzy:
Polák, M.
Neuberger, P.
Rutkowski, K.
Powiązania:
https://bibliotekanauki.pl/articles/291806.pdf
Data publikacji:
2007
Wydawca:
Polskie Towarzystwo Inżynierii Rolniczej
Tematy:
biomasa
spalanie
tlenek azotu
recyrkulacja spalin
biomass
burning
nitrogen oxide
exhaust gas recirculation (EGR)
Opis:
W procesie spalania biopaliw, pochodzenia roślinnego pojawia się problem zwiększonej koncentracji tlenków azotu w odprowadzanych spalinach. Aby obniżyć zawartość tlenków azotu w spalinach kotłów wielkoprzemysłowych stosuje się recyrkulację spalin. Celem prowadzonych badań było sprawdzenie wymienionej technologii w kotłach małej mocy podczas procesu spalania biomasy. Przedmiotem badań był kocioł wodny o mocy 25 kW gdzie jako paliwo stosowano pelety z drewna o średnicy 8 cm oraz ziarno żyta. Uzyskane wyniki badań potwierdziły rozpatrywaną wyżej analogię. Najkorzystniejsze wyniki uzyskano przy recyrkulacji r = 0,3 ze współczynnikiem nadmiaru powietrza [lambda] = 1,3÷1,4 przy spalaniu pelet z drewna, zaś [lambda] = 1,5÷1,6 w przypadku spalania ziarna żyta.
There is a problem of increased concentration of nitrogen oxides in exhaust systems in the process of biofuel originating from plants. Ehaust gas recirculation is used in order to reduce nitrogen oxide content in the industrial boilers. The purpose of research was to apply and observe the mentioned process in small power boilers during the process of biomass burning. A 25 kW water boiler burning 8 cm dia. wood pellets and rye grain was selected as the subject of research. The obtained results confirmed analogy mentioned above. Most beneficial results were obtained at recirculation r = 0.3 using air ratio [lambda] = 1.3÷1.4 while burning wood pellets, while air ratio of [lambda] = 1.5÷1.6 was used for burning of grain.
Źródło:
Inżynieria Rolnicza; 2007, R. 11, nr 7 (95), 7 (95); 169-176
1429-7264
Pojawia się w:
Inżynieria Rolnicza
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ warunków pogodowych w okresie zimowym na skład pokarmu uszatki Asio otus w Lesie Dąbrowa pod Lublinem
The influence of the winter weather conditions on the food of Long-eared Owl Asio otus in Dabrowa Forest near Lublin
Autorzy:
Wiacek, J.
Krawczyk, R.
Polak, M.
Powiązania:
https://bibliotekanauki.pl/articles/880555.pdf
Data publikacji:
2011
Wydawca:
Szkoła Główna Gospodarstwa Wiejskiego w Warszawie. Leśny Zakład Doświadczalny. Centrum Edukacji Przyrodniczo-Leśnej w Rogowie
Tematy:
ptaki
uszatka
Asio otus
sklad pokarmu
zima
warunki atmosferyczne
okolice Lublina
Źródło:
Studia i Materiały Centrum Edukacji Przyrodniczo-Leśnej; 2011, 13, 2[27]
1509-1414
Pojawia się w:
Studia i Materiały Centrum Edukacji Przyrodniczo-Leśnej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Heat recuperation from exhaust air in a sports hall with swimming pool
Autorzy:
Nuberger, P.
Sleger, V.
Polak, M.
Powiązania:
https://bibliotekanauki.pl/articles/60995.pdf
Data publikacji:
2007
Wydawca:
Polska Akademia Nauk. Stowarzyszenie Infrastruktura i Ekologia Terenów Wiejskich PAN
Opis:
This paper deals with the determination of several efficiency types of a cross-current recovery exchanger which is a part of the air venting system in the swimming pool hall on the premises of the Czech University of Life Sciences (CULS) in Prague. The product is a cross-current plate exchanger with a heat-exchanging surface of antirust aluminium. According to the manufacturer, the exchanger is fit for temperatures common in air ventilation systems. The air is forced in by fans at a flow quantity of 16,000 m3, maximum speed 2000 rpm, electric motor output 7.5 kW, filters for the air coming from the outside – grade G4, pressure loss from 42 to 200 Pa, filters for the air coming from the inside – grade G3, pressure loss from 46 to 200 Pa. The results presented are derived from in-process measurements taken on 31 January 2007 and 7 February 2007, from 9.15 to 11.30 on both days. Air temperature and air humidity were measured with 9636-51B-type sensors by Ahlborn, connected to the AHLBORN ALMEMO 5990-2 centre. These sensors were placed into each of the four input/output channels, very close to the exchanger itself (Fig. 2). The data measured were saved in the centre memory every minute. Figures 3, 4, 5 and 6 show the temperature and humidity curves at the exchanger inlets and outlets on measurement days as well as outside air temperature (te) and outside air relative humidity (φe) captured by the met station on the CULS premises. Table 2 shows efficiency ranges calculated according to relations (1), (3), (4), (5), and (6) for air parameters ascertained at exchanger inlets and outlets on 31 January and 7 February 2007 and the calculated flow rates (Table 1). The difference between the outside temperature te and outside humidity φe values taken by the met station and the temperature te1 and humidity φe1 values measured at the recuperator inlet can be explained as resulting from the air being drawn in from the premises affected by the building and 8-m air piping situated in the building’s interior. Heat transmission to the surrounding air occurs despite the mineral wool heat insulation applied to the air piping. The slight increase of thermal efficiency observed on 7 February 2007 resulted from throttling down the recuperator feed air inlet flaps. Reducing the heated air discharge volume (see Table 1) resulted in a greater temperature difference te2 – te1. Energetic efficiency η is lower than thermal efficiency ηt because equation 3 takes into account the effect of condensed vapours in the cooled waste air. According to the manufacturers, the efficiency of top-class exchangers exceeds 70 %. This value might suggest that almost all the air energy available in the given space is utilised. Closer examination reveals that what is presented is thermal efficiency, which is always higher than other kinds of efficiency (see Table 2). Low exergetic efficiency is a sign that there still is a potential in terms of transmission of recovered air utilised energy (exergy).
Źródło:
Infrastruktura i Ekologia Terenów Wiejskich; 2007, 3
1732-5587
Pojawia się w:
Infrastruktura i Ekologia Terenów Wiejskich
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies