Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Dyner, M." wg kryterium: Autor


Wyświetlanie 1-3 z 3
Tytuł:
Analysis of forming thin titanium panels with stiffeners
Autorzy:
Adamus, J.
Winowiecka, J.
Dyner, M.
Powiązania:
https://bibliotekanauki.pl/articles/352785.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
commercially pure titanium
sheet
numerical simulation
sheet metal forming
Opis:
The growing demand for light and durable products has caused an increase in interest in products formed of thin sheets. In order to ensure sufficient stiffness of the drawn - parts, stiffening is often performed. Unfortunately, during the forming of stiffeners unwanted deformations of the drawn parts very often appear, which prevent them from further exploitation. In the paper, forming thin titanium panels with stiffeners is analysed. The panels are made of sheets of commercially pure titanium: Grades 2, 3 and 4. In the results of numerical analyses which were performed using PamStamp 2G, taking into consideration the impact of the blank holder force and friction conditions on the strain distribution in the drawn parts, sheet thinning and springback values are presented. The numerical analysis results were compared with the experimental tests. It was concluded that in order to prevent panel deformation being a result of residual stresses, it is necessary to ensure adequate friction conditions on the contact surfaces between the deformed material and tools as well as a suitable blank holder force.
Źródło:
Archives of Metallurgy and Materials; 2017, 62, 1; 173-180
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Numeryczna symulacja stanu naprężeń i odkształceń w pincetach do zastosowań medycznych
Numerical simulation of the stress and strain in the forceps for medical use
Autorzy:
Lacki, P.
Jasiński, J.
Jeziorski, L.
Lubas, M.
Szota, M.
Dyner, M.
Powiązania:
https://bibliotekanauki.pl/articles/257741.pdf
Data publikacji:
2007
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Technologii Eksploatacji - Państwowy Instytut Badawczy
Tematy:
metoda elementów skończonych
MES (metoda elementów skończonych)
pinceta
optymalizacja
narzędzia medyczne
finite element method
FEM
forcep
optimization
medical tools
Opis:
Proces projektowania pincety wymaga optymalizacji wielu parametrów, należy rozważyć wiele funkcji, jakie powinna spełniać, a także uwzględnić ograniczenia projektowe. Należy również uwzględnić hierarchię ich ważności. W niniejszej pracy zaprezentowano część metodyki rozwiązania tego typu problemów. Zaprezentowane w pracy procedury analizy pincet pozwalają na dokładne określenie wymiarów geometrycznych zgodnie z wymaganiami funkcjonalnymi, jakie musi spełnić pinceta. Prezentowana analiza numeryczna opisuje nieznaczny obszar zastosowań pincet, jednak zastosowany algorytm postępowania można dostosować do każdego typu pincet. Przeprowadzone obliczenia pozwalają na określenie parametrów geometrycznych w stosunku do oczekiwanej sztywności sprężyny. Wykresy opracowane na podstawie obliczeń są pomocne na etapie projektowania pincety. Obliczenia numeryczne zwróciły uwagę na istotny problem zmiany powierzchni kontaktu w funkcji obciążenia. Zaobserwowane zjawisko może źle wpływać na funkcjonowanie pincety w przypadku braku uwzględnienia go na etapie projektowania narzędzia.
In order to design forceps properly it is necessary to optimise many parameters and consider the functions which it should fulfil. Of course, some simplifications are necessary respecting calculation methodology. In the paper, the solution procedure of such a problem has been presented. The presented solution allows for the precise determination of the geometrical dimensions according to the functional requirements that forceps should fulfil. The presented numerical analysis describes the small range of forceps application but the algorithm used can be applied in any other type of forceps. The carried out calculations allow for determination of the geometrical parameters with reference to the expected spring rate. The charts elaborated on the basis of the calculations are very useful during the stage of forceps design. The numerical calculations show, the essential problem, namely, the change in contact surface as a function of load. The observed phenomenon can badly affect the forceps functioning.
Źródło:
Problemy Eksploatacji; 2007, 1; 7-21
1232-9312
Pojawia się w:
Problemy Eksploatacji
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
New design of patient-specific, antimicrobial bioactive finger implants for durable functional reconstruction after amputation
Autorzy:
Dyner, Marcin
Byrski, Adam
Major, Roman
Gawlikowski, Maciej
Kasperkiewicz, Katarzyna
Lackner, Juergen M.
Dyner, Aneta
Major, Bogusław
Powiązania:
https://bibliotekanauki.pl/articles/2058387.pdf
Data publikacji:
2021
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
finger implant
thin coatings
microstructure
cytotoxicity
microbiology
implanty
palce
cytotoksyczność
mikrobiologia
Opis:
The absence of even a single finger results in a major impairment in the hand function (precise grasping, grip power), therefore significantly affecting the social and professional life of victims who are frequently young people. Finger amputation is a surgical treatment for ~69.000 patients in the EU after traumatic injury, in which replantation microsurgery fails due to the severity of tissue damage. The surgical reconstruction is currently possible only via autograft transplantation, e.g. a toe-to-hand transfer, thus leading to foot impairment. Some motion functional restoration is also possible using a bone-anchored silicone prosthesis but without the sense revalidation. Our current research focuses on alternatives for surgical reconstruction by means of novel patient- -specific, durable, biomimetic, bioactive and antibacterial implants for reconstructing lost bone and joints. The implant design – and the improved micro(neuro) surgery (beyond the project) – will consist in the fast successful rehabilitation, including the soft-tissue related mobility, the implantation of state-of-the-art nerve conduits as well as the aesthetic appearance. Key issues for the long-term functionality of the biomaterial-based reconstruction of hard tissue are based on surgical demands, such as: (1) perfect integration of a bone-substituting metal with the surrounding bone tissue (a) with no signs of loosening due to stress shielding at the interface and (b) enhanced with protective activity against bacterial inflammation (antimicrobial properties and formation of vascularized bone tissue (ossification)) even months to years after the injury; (2) biomimetic finger joints based on non-wearing materials without ossification meant to prevent the loss of the motion function.
Źródło:
Engineering of Biomaterials; 2021, 24, 161; 8--14
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-3 z 3

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies