Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "micro-CT" wg kryterium: Wszystkie pola


Wyświetlanie 1-13 z 13
Tytuł:
Pomiary porowatości skał metodą rentgenowskiej mikrotomografii komputerowej (Micro-CT)
Rock porosity measurements using Roentgen computed microtomography (Micro-CT)
Autorzy:
Dohnalik, M.
Zalewska, J.
Powiązania:
https://bibliotekanauki.pl/articles/183665.pdf
Data publikacji:
2009
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
porowatość
mikrotomografia
porosity
microtomography
Opis:
Roentgen computed microtomography is an imaging technique that generates high resolution 3D images of internal structure, basing on difference in X-rays absorption inside the sample. Micro-CT provides new possibilities to obtain up to few microns resolution images of reservoir rocks in non destructive way. Such images enables to visualize and quantitative analysis of mineral composition and pore structure (volume, shape and pore throat diameter), which can be used to better understanding petrophysical properties such as permeability. This paper shows test of direct, quantitative porosity measurement based on 3D images obtained using Benchtop device and AVIZO software.
Źródło:
Geologia / Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie; 2009, 35, 2/1; 617-624
0138-0974
Pojawia się w:
Geologia / Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Polymerization shrinkage of new flow-type dental composite using micro-CT
Autorzy:
Pałka, K.
Zaszczyńska, A.
Kleczewska, J.
Powiązania:
https://bibliotekanauki.pl/articles/285431.pdf
Data publikacji:
2016
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
dental composites
polymerization
shrinkage
Źródło:
Engineering of Biomaterials; 2016, 19, 138; 75
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Non-destructive analysis of pathological belemnite rostra by micro-CT techniques
Autorzy:
Hoffmann, R.
Stevens, K.
Picollier, M.-C.
Mutterlose, J.
Klug, C.
Powiązania:
https://bibliotekanauki.pl/articles/2082134.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Instytut Paleobiologii PAN
Tematy:
Cephalopoda
Belemnitida
palaeopathology
rostra
micro computed-tomography
diagenesis
Jurassic
Cretaceous
Germany
Opis:
Previously, palaeopathological features of fossil hardparts were often difficult to interpret because it was impossible to decipher their internal structure without destroying the specimens. We applied high-resolution computedtomo graphy (CT) to document such internal structures. This enabled us to describe a variety of pathologies of Jurassic and Cretaceous belemnite rostra. The examined rostra have been assigned to the taxa ?Acrocoelites sp., Belemnello camax spp., Belemnitella sp., Duvalia emerici, Goniocamax sp., Gonioteuthis spp., Hibolithes jaculoides, Neoclavibelus subclavatus, and Pseudobelus sp. The studied pathologies comprise rostra with two apices, bulges, pearls, broken juvenile rostra, highly porous rostra with abnormal growth increments, blunt-rostra, rostra with callus- like structures, and bent- or knee-shaped rostra. In one rostrum the apex has been turned towards the anterior (alveolus) during ontogeny. Additionally, computed-tomography data were used to document diagenetic alterations of the rostra such as silification, sedimentary infill, pyrite formation. Specimens can also be tested for the presence or absence of internal elements (septa, siphuncle) and surface features. Palaeoecological studies clearly benefit from the application of computed-tomography to gain high resolution images of otherwise invisible internal features of extinct organisms, as demonstrated herein.
Źródło:
Acta Palaeontologica Polonica; 2020, 65, 1; 11-27
0567-7920
Pojawia się w:
Acta Palaeontologica Polonica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Microstructure characterization by means of X-ray micro-CT and nanoindentation measurements
Autorzy:
Rajczakowska, M.
Stefaniuk, D.
Łydżba, D.
Powiązania:
https://bibliotekanauki.pl/articles/178547.pdf
Data publikacji:
2015
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
micro-CT
nanoindentation
microstructure
composite
Opis:
The aim of this paper is to present an example of the material microstructure characterization with the use of X-ray micro-CT and nanoindentation measurements. Firstly, the current scope of application of the aforementioned techniques is provided within different fields of science. Then, background of each of the methods is presented. The methodology of X-ray micro-CT is described with the emphasis on the Beer’s law formulation. In addition, the basics of the nanoindentation technique are outlined and major formulas for the hardness and Young’s modulus calculation are given. Finally, example results for a concrete sample are presented. The microstructure of the selected material is firstly characterized in terms of geometry using the results from the microtomograhy measurements, e.g., porosity and attenuation profiles, pore and aggregate size distribution, shape factor of pores, etc. Next, the results of the nanoindentation tests are provided, namely the hardness and Young’s modulus versus the height of the sample. The influence of the number of tests and statistical analysis on the final results is underlined.
Źródło:
Studia Geotechnica et Mechanica; 2015, 37, 1; 75-84
0137-6365
2083-831X
Pojawia się w:
Studia Geotechnica et Mechanica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Structural variability of lyophilized collagen-based scaffolds: micro-CT 3D analysis
Autorzy:
Bartos, M.
Suchy, T.
Spanko, M.
Foltan, R.
Powiązania:
https://bibliotekanauki.pl/articles/286100.pdf
Data publikacji:
2018
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
bone tissue engineering
scaffolds
regeneration
Źródło:
Engineering of Biomaterials; 2018, 21, 148; 24
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Micro-CT analysis of bonding of conventional and glass fibre composite fillings
Autorzy:
Surowska, B.
Ostapiuk, M.
Tarczydło, B.
Powiązania:
https://bibliotekanauki.pl/articles/284063.pdf
Data publikacji:
2016
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
composite materials
glass fibres
tests
Źródło:
Engineering of Biomaterials; 2016, 19, 138; 39
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badanie 3D struktury przestrzeni porowej cementów metodą mikrotomografii rentgenowskiej (micro-CT)
Examination of internal pore space 3D images of cement rock with use of Roentgen Computed Tomography (Micro-CT)
Autorzy:
Dohnalik, M.
Zalewska, J.
Kut, Ł.
Kaczmarczyk, J.
Powiązania:
https://bibliotekanauki.pl/articles/349787.pdf
Data publikacji:
2010
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
cement
struktura porowa kamieni cementowych
rozwój porowatości
mikrotomografia
cement rock pore structure
pore structure evolution
microtomography
Opis:
Metoda mikrotomografii rentgenowskiej (micro-CT) jest nieniszczącą metodą badawczą, która umożliwia wizualizację budowy wewnętrznej obiektów (w geologii np. skał i cementów). Metoda polega na rejestracji projekcji promieniowania X badanej próbki pod różnymi kątami, a następnie rekonstrukcji na tej podstawie struktury wewnętrznej próbki. Wizualizowanym parametrem jest współczynnik atenuacji liniowej, który zależy od energii promieniowania X, liczby atomowej pierwiastków budujących obiekt oraz gęstości badanej próbki. Micro-CT może być stosowana zarówno do jakościowej wizualizacji wewnętrznej struktury cementów, jak również do pozyskiwania danych ilościowych. Celem tego artykułu jest przedstawienie zastosowania mikrotomografii rentgenowskiej w badaniu cementów. W pracy zaprezentowano, po raz pierwszy w kraju, wyniki mikrotomograficznych badań mikrostruktury zaczynów cementowych w różnym wieku (1 do 28 dni). Wyniki pozwoliły przeanalizować zmiany w sieci porowej zaczynów podczas ich starzenia. Wykazano znaczące różnice w ewolucji porów pomiędzy próbami zaczynów o różnych składach. Wyniki te pokazują możliwości metody micro-CT w badaniu materiałów cementowych. Główną zaletą metody jest możliwość odtworzenia sieci porowej oraz prześledzenia zmian wielkości porów w czasie. Dzięki tej metodzie możliwe jest także badanie nowych cech, takich jak dystrybucja przestrzenna struktury porowej oraz określenie jej przewodności.
The X-ray computed microtomography (micro-CT) is a non-destrictive method for visualization of objects' internal structures (in geology - e.g. rocks or cement stones). Sample's X-ray projections at different angles are recorded and, on the basis of them, the objects' internal structure is reconstructed. Visualized parameter is the linear attenuation coefficient (proportional to X-ray's energy, material's density and atomic number of elements in object's structure). The micro-CT may be used to visualize the cement's internal structure and its quantitative analysis. The aim of this paper is to show application of micro-CT in cementary rocks examination. In this work the results of micro-CT measurement for cements of different age (1-28 days) are shown first time in Poland. Obtained results allowed to analyze changes of pore network during the cement rock's shrinking. Significant pore space evolution changes in case of cement rocks with different composition were observed. Results shown that micro-CT method is applicable for cement rocks examination. The main adventage of micro-CT is the ability to reconstruction of pore space and observation of its changes in time. Also the pores' spatial distribution and tortuosity may be examined.
Źródło:
Górnictwo i Geoinżynieria; 2010, 34, 4; 157-165
1732-6702
Pojawia się w:
Górnictwo i Geoinżynieria
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Methodological add-ons to a non-destructive, micro-CT-based taxonomic/morphometric analysis of characean remains
Autorzy:
Benyó-Korcsmáros, Réka
Gulyás, Sándor
Sebők, Dániel
Benyó, Dániel
Cseh, Péter
Sümegi, Pál
Powiązania:
https://bibliotekanauki.pl/articles/24201075.pdf
Data publikacji:
2023
Wydawca:
Uniwersytet im. Adama Mickiewicza w Poznaniu
Tematy:
characeae
computer tomography
gyrogonite
tomografia komputerowa
gyrogonit
Opis:
Ever since its introduction, computed tomography has come a long way. No longer is it merely a method that is used in clinical diagnostics, but it is becoming more and more popular among palaeontologists because it can be used to analyse both external and internal structures of fossil remains, such as small insects, snail shells and plant remains. The present study describes non-destructive analyses of Late Cretaceous and early Holocene charophyte gyrogonites by using the micro-CT technique, from sample preparation (embedding, fixing) to visualisation and assessment of images obtained. In addition to this non-destructive examination, we wished to test whether or not computed tomography could be used to examine the gyrogonites. Our preliminary results have made it clear that the micro-CT technique is worth employing for further research. It has proved possible to visualise the samples in 3D, rotate them, and observe them from different directions. By using the appropriate parameters, we have also been able to observe density differences between parts of characean remains and to study several important defining features of these.
Źródło:
Geologos; 2023, 29, 2; 69--75
1426-8981
2080-6574
Pojawia się w:
Geologos
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Evaluation of Properties of Cast Metal Foams with Irregular Inner Structure
Autorzy:
Kroupová, I.
Lichý, P.
Ličev, L.
Hendrych, J.
Souček, K.
Powiązania:
https://bibliotekanauki.pl/articles/355316.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
metal foams
irregular structure
precursor
porosity
micro-CT
Opis:
Internal structure of metal foams is one of the most important factors that determine its mechanical properties. There exists a number of methods for studying the nature of the inner porous structure. Unfortunately most of these processes is destructive and therefore it is not possible to reuse the sample. From this point of view, as a suitable method seems to be the ability of using the so-called X-ray microtomography (also micro-CT). This is a non-destructive methodology used in a number of fields (industry, science, archaeology, medicine) for a description of the material distribution in the space (e.g. pores, fillers, defects, etc.). In principle, this technology works on different absorption of X-ray radiation by materials with changing proton number. The contribution was worked out in collaboration with experts from the Faculty of Electrical Engineering and Computer Science of the VŠB-Technical University of Ostrava and it is focused on the analysis of internal structure of the metal foam casting with irregular arrangement of internal pores by using micro-CT. The obtained data were evaluated in the commercial software VGStudio MAX 2.2 and in the FOTOMNG system. For the evaluation of these data a new specialized module was introduced in this system. Several methods of pre-processing the image was prepared for the measurement. This preliminary processing consists, for example, from a binary image thresholding for better diversity between the internal porosity and the material itself or functions for colour inversion.
Źródło:
Archives of Metallurgy and Materials; 2018, 63, 4; 1847-1851
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza mikro-CT zębów trzonowych wypełnianych kompozytem konwencjonalnym i wzmacnianym włóknem szklanym
Micro-CT analysis of molar teeth restored by combining conventional and glass fibre reinforced composites
Autorzy:
Surowska, B.
Ostapiuk, M.
Tarczydło, B.
Powiązania:
https://bibliotekanauki.pl/articles/284782.pdf
Data publikacji:
2016
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
mikrotomografia komputerowa
wypełnienia kompozytowe
adhezja
struktura
computer micro-tomography
fillings
composite restoration
adhesion
structure
Opis:
Utrata tkanek zmineralizowanych zęba zarówno w efekcie procesów patologicznych, jak i samego leczenia jest czynnikiem decydującym o osłabieniu zęba. Najczęściej pojawiają się pęknięcia na powierzchni wypełnienia w następstwie powtarzających się cykli nagryzień. Rozprzestrzeniają się one wówczas w zębie i wypełnieniach. Pęknięcia obok mikroprzecieków są jednym z głównych powodów wymiany wypełnień. Ostatnio najczęściej wybieranymi, zarówno przez lekarzy stomatologów jak i pacjentów, materiałami odtwórczymi są materiały kompozytowe. Istnieje wiele sposobów zwiększania odporności mechanicznej kompozytów stomatologicznych np. umieszczanie ich w formie licowania na konstrukcjach metalowych lub wprowadzania do ich wnętrza różnego rodzaju włókien: szklanych, węglowych, poliaramidowych lub polietylenowych. Jednym z takich innowacyjnych materiałów jest everX Posterior firmy GC, kompozyt wzmocniony krótkim włóknem szklanym. Materiał ten posiada właściwości mechaniczne zbliżone do zębiny, używany jest do wypełnień ubytków w zębach bocznych jako pierwsza warstwa odtwarzająca zębinę. Zaawansowana nieniszcząca technika obrazowania struktur za pomocą tomografii komputerowej (CT) stanowi doskonałe narzędzie analizy jakości materiałów. Dlatego w prezentowanej pracy zastosowano technikę mikro-CT do analizy jakości wypełnienia i połączenia dwóch materiałów do odbudowy ubytków. W badaniu wykorzystano zęby trzonowe trzecie bez próchnicy usunięte ze względów ortodontycznych. Biomateriał kompozytowy wzmocniony włóknem szklanym everX Posterior firmy GC aplikowano jedną 2-3 mm warstwą, a następnie aplikowano kompozyt konwencjonalny Filtek Z250, 3M ESPE metodą warstwową 2-3 mm. Analizowana struktura zęba oraz materiałów kompozytowych potwierdza wysokiej jakości wypełnienia. Brak porowatości oraz szczeliny brzeżnej pozwala na wyeliminowanie mikro-przecieków pomiędzy wypełnieniami a tkanką zęba. Ponadto, granica rozdziału pomiędzy kompozytem wzmacnianym włóknami a kompozytem wzmacnianym nanocząstkami wydaje się doskonała.
The loss of mineralized tissues of the tooth as a result of pathogenic processes and treatment is the principal factor leading to tooth weakening. Most frequently, the cracks occur on the filling surface as a result of repeatable cycles of bites. They propagate in the tooth and the filling. The cracks belong to the reasons of filling's replacement and consequently affecting filling's durability. Recently, composite materials are most frequently selected by the dentists and patients as reconstruction materials. There are many ways of increasing mechanical resistance of dental composites e.g. their location in the form of facing on metal structures or introduction of various fibres made of glass, carbon, aramid or polyethy-lene. EverX Posterior is manufactured by GC in the form of composite reinforced with short glass fibres. The properties of this material are similar to the properties of dentine. Therefore it is used for cavity filling in side teeth as the first layer of dentine reconstruction. Advanced non-destructive structures imaging technique by means of computer tomography (CT) is an excellent tool used for materials quality analysis. So the micro-CT analysis of quality and joining of restorative materials based on different filler was presented in this paper. Third molars without caries, extracted due to orthodontic reasons, have been used in the test. Composite biomaterial reinforced with glass fibre - everX Posterior by GC – was applied in the form of single layer and next Filtek Z250, 3M ESPE conventional composite was applied in the form of layer with a thickness of 2-3 mm. Analysed structure of the tooth and composite materials confirms the high quality of the restoration. The filling received by layer technique is free of porosities, thus suggesting the lack of micro-leakages between the filling and tooth tissues. Moreover, the interface between the fibre reinforced and particle reinforced nanocomposite biomaterials seems to be ideal.
Źródło:
Engineering of Biomaterials; 2016, 19, 137; 13-19
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The ability of S.aureus to form biofilm on the Ti-6Al-7Nb scaffolds produced by Selective Laser Melting and subjected to the different types of surface modifications
Autorzy:
Szymczyk, P.
Junka, A.
Ziółkowski, G.
Smutnicka, D.
Bartoszewicz, M.
Chlebus, E.
Powiązania:
https://bibliotekanauki.pl/articles/306293.pdf
Data publikacji:
2013
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
SLM
micro-CT
scaffolds
Ti-6Al-7Nb alloy
orthopedics
S.aureus
ortopedia
Opis:
The Gram-positive coccus, Staphylococcus aureus, is the leading etiologic agent of limb and life-threatening biofilm-related infections in the patients following the orthopaedic implantations. The aim of the present paper is to estimate the ability of S. aureus to form biofilm on titanium alloy (Ti-6Al-7Nb) scaffolds produced by Selective Laser Melting (SLM) and subjected to the different types of surface modifications, including ultrasonic cleaning and chemical polishing. The results obtained indicate significantly the decreased ability of S.aureus to form biofilm on the surface of scaffolds subjected to the chemical polishing in comparison to the scaffolds cleaned ultrasonically. The data provided can be useful for future applications of the SLM technology in production of Ti-6Al-7Nb medical implants.
Źródło:
Acta of Bioengineering and Biomechanics; 2013, 15, 1; 69-76
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowanie mikrotomografii komputerowej w analizie żywności
The use of micro computed tomography in food analysis
Autorzy:
Zalewska, M.
Powiązania:
https://bibliotekanauki.pl/articles/270843.pdf
Data publikacji:
2016
Wydawca:
Centralny Ośrodek Badawczo-Rozwojowy Aparatury Badawczej i Dydaktycznej, COBRABiD
Tematy:
mikrotomografia komputerowa
struktura żywności
wizualizacja 3D
micro-CT
micro-computed tomography
food structure
3D visualization
Opis:
Celem niniejszej pracy jest przedstawienie metody mikrotomografii komputerowej (micro-CT), jako przydatnego narzędzia do analizy żywności. Micro-CT to nieinwazyjna technika badawcza, która pozwala odwzorować strukturę wewnętrzną badanego obiektu na podstawie jego dwuwymiarowych projekcji zarejestrowanych pod różnymi kątami. Pozwala na odkrycie struktur wewnętrznych bez ingerencji w fizyczną strukturę badanego materiału. Metoda ta znalazła zastosowanie w wielu dziedzinach nauki i techniki. W przemyśle spożywczym może być wykorzystana do analizy produktów żywnościowych, do oszacowania zawartości poszczególnych składników żywności, a także uzyskania informacji na temat ich rozmieszczenia. Zastosowanie mikrotomografii komputerowej pozwala na zachowanie wysokiej jakości produktów podczas procesu produkcyjnego. Metoda ta przydatna jest także w celu optymalizacji procesów, czyli w uzyskaniu informacji na temat parametrów procesu technologicznego. W pracy przedstawiono zastosowanie metody mikrotomografii komputerowej w przemyśle mięsnym, cukierniczym oraz owocowo-warzywnym.
The aim of this study is to present the method of computer microtomography (micro-CT) as a useful tool for the analysis of food. Micro-CT is a nondestructive research technique for studying the internal structure of the sample based on its two-dimensional projection recorded at different angles. Allows for the discovery of internal structures without interfering with the physical structure of the material being tested. This method has been used in many fields of science and technology. Estimated content of each food ingredients as well as provide information about their location. The use of computer microtomography allows to maintain the high quality of the products during the manufacturing process. This method is also useful for process optimization, which is obtained information about the parameters of technology microtomography use in the meat, confectionery and fruit-vegetables industry is presented.
Źródło:
Aparatura Badawcza i Dydaktyczna; 2016, 21, 2; 85-92
2392-1765
Pojawia się w:
Aparatura Badawcza i Dydaktyczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Application of the X-ray micro-computed tomography to the analysis of the structure of polymeric materials
Zastosowanie mikrotomografii komputerowej do analizy struktury materiałów polimerowych
Autorzy:
Szewczykowski, Piotr P.
Skarżyński, Łukasz
Powiązania:
https://bibliotekanauki.pl/articles/947106.pdf
Data publikacji:
2019
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Chemii Przemysłowej
Tematy:
microstructure
non-destructive test
polymeric materials
X-ray micro-CT
mikrostruktura
badanie bezinwazyjne
materiały polimerowe
mikrotomografia komputerowa
Opis:
In this paper the application of X-ray micro-computed tomography (micro-CT) as a non-destructive testing method of polymeric materials is presented. Increasing applicability of polymers in variedend-use industries such as automotive, building and construction, consumer goods, and packaging is propelling the growth of the global polymer processing market. However, controlling of the polymer structure is one of the most important aspects since it affects mechanical properties of the components. The paper contains examples of two- and three-dimensional analysis of selected polymeric materials using of X-ray micro-computed tomography. Due to the complex structure of polymers, their shape and pores that are embedded inside the material and are not connected to the surface, the X-ray micro-computed tomography is an ideal solution for the analysis of the microstructure of polymeric materials to improve the process of their production in order to obtain components with the best possible properties.
Przedstawiono zastosowanie mikrotomografii komputerowej do bezinwazyjnej analizy struktury wewnętrznej materiałów polimerowych. Zwiększenie możliwości zastosowania polimerów w różnych branżach, takich jak: motoryzacja, budownictwo i opakowania, napędza rozwój światowego rynku przetwórstwa polimerów. Kontrola struktury materiałów, mającej ogromny wpływ na właściwości mechaniczne kompozytów polimerowych, jest bardzo istotna. Przedstawiona metoda mikrotomografii komputerowej, służąca ulepszeniu procesu wytwarzania komponentów o jak najkorzystniejszych właściwościach, jest idealnym narzędziem do analizy mikrostruktury materiałów polimerowych ze względu na ich złożoną budowę, kształt oraz liczbę porów zawartych w strukturze materiału (niestykających się z jego powierzchnią zewnętrzną). Podano przykłady dwu- i trójwymiarowej analizy mikrostruktury wybranych materiałów polimerowych z zastosowaniem mikrotomografii komputerowej.
Źródło:
Polimery; 2019, 64, 1; 12-22
0032-2725
Pojawia się w:
Polimery
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-13 z 13

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies