Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "indoor air quality" wg kryterium: Wszystkie pola


Tytuł:
Perceived indoor air quality, air-related symptoms and ventilation in Finnish hospitals
Autorzy:
Hellgren, Ulla-Maija
Hyvärinen, Markku
Holopainen, Rauno
Reijula, Kari
Powiązania:
https://bibliotekanauki.pl/articles/2185474.pdf
Data publikacji:
2011-03-01
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
evaluation of ventilation
Indoor Air Questionnaire
perceived indoor air quality
Health care workers
Opis:
Objectives: Good ventilation is more important in hospitals than in many other buildings. The objective of this study was to evaluate the effect of the condition, performance and modernity of ventilation systems on the perceived indoor air quality (IAQ) and the indoor air-related symptoms of hospital personnel. Materials and Methods: An inspection and evaluation graded on a 1 to 3 scale of the condition, performance, and modernity of the ventilation systems was carried out in ten central hospitals in Finland. The perceived IAQ and the related symptoms were collected by means of an indoor air questionnaire survey among the workers in these hospitals. Results: The condition, performance and modernity of the ventilation systems were good in 40% of the hospitals included in the research and poor in another 40% of them. In hospitals where the majority of the ventilation systems were assessed to be good, the prevalence of the indoor air-related complaints and symptoms was lower than in hospitals where the majority of the ventilation systems were assessed as needing extensive repairs. Conclusions: The condition and performance of the ventilation systems in hospitals had a significant impact on the perceived IAQ and the symptoms observed among the employees in Finnish hospitals. Therefore, it is important that hospital ventilation systems are maintained properly and regularly. Furthermore, they should be renovated, at the latest when their technical lifespan expires.
Źródło:
International Journal of Occupational Medicine and Environmental Health; 2011, 24, 1; 48-56
1232-1087
1896-494X
Pojawia się w:
International Journal of Occupational Medicine and Environmental Health
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Jakość powietrza w wielorodzinnych budynkach mieszkalnych
Indoor air quality in multifamily buildings
Autorzy:
Telejko, M.
Zender–Świercz, E.
Piotrowski, J.Z.
Powiązania:
https://bibliotekanauki.pl/articles/390643.pdf
Data publikacji:
2013
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Tematy:
jakość powietrza wewnętrznego
mikroklimat
wymiana powietrza
fizyka budowli
indoor air quality
microclimate
air exchange
building physics
Opis:
Obowiązujące aktualnie przepisy prawne regulujące zagadnienia wentylacji naturalnej [1], [2], [3] w wielu obszarach są niejednoznaczne, a niekiedy wręcz sprzeczne. Sytuacja taka prowadzi do stosowania rozwiązań powodujących poważne zaburzenia w działaniu wentylacji grawitacyjnej. W dużej części budynków zaburzenia te są wynikiem dostarczania do pomieszczeń zbyt małej ilości powietrza zewnętrznego. Jak wykazały badania, ze względu na kształtowanie warunków mikroklimatu wnętrz, podstawowe znaczenie ma nie tylko wielkość dostarczanego strumienia powietrza zewnętrznego, ale również rozmieszczenie elementów doprowadzających to powietrze.
The applicable legislation connected with the natural ventilation are ambiguous and sometimes contradictory. This leads to serious problems with natural ventilation. In most cases malfunction of the natural ventilation is due to the insufficient stream of air from the outside. The research showed that the microclimate is influenced not only by the incoming air stream, but also by the layout of the air supply.
Źródło:
Budownictwo i Architektura; 2013, 12, 3; 67-74
1899-0665
Pojawia się w:
Budownictwo i Architektura
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of indoor air quality in a store with additional gas heater
Autorzy:
Wysocka, Monika
Załuska, Maciej
Powiązania:
https://bibliotekanauki.pl/articles/1177489.pdf
Data publikacji:
2018
Wydawca:
Przedsiębiorstwo Wydawnictw Naukowych Darwin / Scientific Publishing House DARWIN
Tematy:
air pollution
carbon dioxide
gas heater
heating
indoor air quality
thermal comfort
ventilation
Opis:
The quality of the internal environment is an extremely important issue, because users of rooms spend a significant part of the day inside buildings. The quality of the environment is largely dependent on the quality of the indoor air. The parameters of the air we breathe affect our health and the comfort of use of the rooms. Poor indoor air quality can cause a decrease in human comfort and various illnesses and ailments. Therefore, care should be taken to ensure adequate ventilation in the rooms, especially those that have an additional source of pollutant emissions. The purpose of this work is to examine the effect of heating a commercial premises room with a gas heater on air quality. The following parameters were measured as part of the tests: carbon dioxide concentration, air temperature and relative air humidity. The most important parameter significantly affecting the deterioration of the quality of the interior microclimate is carbon dioxide, the level of which reached high values, well above the hygienic minimum (1000 ppm). In order to compare the values of the tested parameters, the measurements were carried out in two options - for a period of five days with the stove running and another two days without additional heating.
Źródło:
World Scientific News; 2018, 102; 209-216
2392-2192
Pojawia się w:
World Scientific News
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Indoor air quality in computer labs
Jakość powietrza wewnętrznego w pracowniach komputerowych
Autorzy:
Telejko, M.
Powiązania:
https://bibliotekanauki.pl/articles/402282.pdf
Data publikacji:
2015
Wydawca:
Politechnika Świętokrzyska w Kielcach. Wydawnictwo PŚw
Tematy:
building physics
ventilation
air exchange
indoor air quality
CO2 concentration
fizyka budowli
wentylacja
wymiana powietrza
jakość powietrza wewnętrznego
stężenie CO2
Opis:
The article presents the results of indoor air quality measurements in three university computer labs. In the spaces concerned natural ventilation system has been applied. The obtained results indicate a very low air quality in this type of room.
Źródło:
Structure and Environment; 2015, 7, 4; 194-198
2081-1500
Pojawia się w:
Structure and Environment
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Microbiological indoor air quality in Polish schools
Mikrobiologiczna jakość powietrza w polskich szkołach
Autorzy:
Dumała, S. M.
Dudzińska, M. R.
Powiązania:
https://bibliotekanauki.pl/articles/1818752.pdf
Data publikacji:
2013
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
jakość powietrza
polskie szkoły
Opis:
Większość ludzi spędza ponad 90% swojego życia wewnątrz pomieszczeń m.in.: w domach, biurach i szkołach, gdzie narażeni są na działanie różnych czynników środowiska wewnętrznego (np. bioaerozoli) wpływających na ich zdrowie i kondycję fizyczną. Dlatego w ostatnich latach stale rośnie zainteresowanie badaniami wewnętrznych zanieczyszczeń biologicznych. Celem tych badań jest nie tylko szacunkowa ocena ilości mikroorganizmów w powietrzu, ale również ich identyfikacja i określenie czynników wpływających na skład bioaerozolu wewnątrz pomieszczeń. Biologiczne zanieczyszczenie powietrza w pomieszczeniach jest najczęściej spowodowane przez bakterie i grzyby. Nie tylko samo ich występowanie w formie żywych komórek patogennych może być szkodliwe dla zdrowia, ale również wydzielane przez nie substancje stanowią spore zagrożenie. W artykule zbadano szkoły z terenu Lublina pod kątem zanieczyszczeń mikrobiologicznych. Badania przeprowadzono podczas okresu grzewczego (marzec) i bez ogrzewania (maj). Próbki powietrza pobierano przed lekcją oraz podczas jej trwania. Zidentyfikowano następujące bakterie i grzyby: Bacillus lentus, Bacillus licheniformis, Bacillus pumilus, Bacillus cereus,Pseudomonas stutzeri, Micrococcus ssp., Staphylococcus xylosus, Staphylococcus saprophyticus, Staphylococcus haemolyticus, Acremonium, Aerobasidium, Aspergillus, Aspergillusniger, Alternaria, Cladosporium, Epicocum, Mucor, Penicilinium. Wśród tych drobnoustrojów wykryto obecność mikroorganizmów chorobotwórczych i o silnym działaniu uczulającym.
Źródło:
Rocznik Ochrona Środowiska; 2013, Tom 15, cz. 1; 231-244
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena jakości powietrza wewnętrznego w wybranych przedszkolach
Indoor air quality in a preschool
Autorzy:
Telejko, M.
Powiązania:
https://bibliotekanauki.pl/articles/391209.pdf
Data publikacji:
2014
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Tematy:
fizyka budowli
wentylacja
wymiana powietrza
jakość powietrza wewnętrznego
building physics
ventilation
air exchange
indoor air quality
preschool building
Opis:
W artykule przedstawiono wyniki badań jakości powietrza wewnętrznego przeprowadzonych w 4 przedszkolach samorządowych. W rozpatrywanych obiektach zastosowany został system wentylacji grawitacyjnej. Uzyskane wyniki badań wskazują jednoznacznie na bardzo niską jakość powietrza w tego typy budynkach.
The article presents the results of indoor air quality (IAQ) assessment in four local preschools. The natural ventilation system was used in the buildings. Outdoor air was supplied to the premises through a leak in the external walls and air intakes were of maximum efficiency of 30 m3/h. Parameters describing IAQ were measured, such as: temperature, relative humidity and carbon dioxide concentration. Two series of studies were performed in each preschool. On the basis of the survey, it can be clearly stated that the indoor air quality in preschools is considered to be very low very low. All the analyzed parameters describing the quality do not meet the current legal requirements. Reported values of CO2 concentration exceeded three times the value set of the recommended maximum.
Źródło:
Budownictwo i Architektura; 2014, 13, 4; 41-48
1899-0665
Pojawia się w:
Budownictwo i Architektura
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Próba poprawy jakości powietrza wewnętrznego w przedszkolu
Indoor air quality in a preschool
Autorzy:
Koruba, D.
Zender-Świercz, E.
Piotrowski, J.Z.
Orman, Ł.
Telejko, M.
Powiązania:
https://bibliotekanauki.pl/articles/390993.pdf
Data publikacji:
2014
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Tematy:
fizyka budowli
wentylacja
wymiana powietrza
jakość powietrza wewnętrznego
building physics
ventilation
air exchange
indoor air quality
Opis:
W artykule przedstawiono wyniki badań nad jakością powietrza wewnętrznego (IAQ) w jednym z wybranych przedszkoli. W obiekcie zastosowany został system wentylacji grawitacyjnej. Wstępne badania potwierdziły niską jakość powietrza wewnętrznego w podmiotowym budynku. W trakcie badań zaproponowano dwa usprawnienia mające na celu poprawę jakości powietrza: zwiększenie strumienia powietrza nawiewanego oraz, w drugiej kolejności, montaż urządzeń do uzdatniania powietrza wewnętrznego. Uzyskane wyniki badań wskazują, że wprowadzone usprawnienia wpływają na poprawę jakości powietrza wewnętrznego.
The article demonstrates the results of research on the indoor air quality (IAQ) in one of chosen preschools. In such facilities, the standard solution is a system of natural ventilation. Only a small percentage of such buildings is equipped with a mechanical ventilation system with adjustable parameters of the microclimate. The article presents the results of indoor air quality in the local preschool located in Kielce. In the present facility natural ventilation system was used. Preliminary studies confirmed the poor quality of indoor air in a subjected building. During the study, two improvements aimed at improving air quality were proposed. The first improvement was to increase the supply air stream. The second one concerned the installation of equipment for the treatment of indoor air. The results indicate that under certain guidelines it is possible to improve indoor air quality. As an indicator of indoor air quality, concentration of carbon dioxide was adopted. In addition, microbiological tests were performed indoors.
Źródło:
Budownictwo i Architektura; 2014, 13, 4; 7-13
1899-0665
Pojawia się w:
Budownictwo i Architektura
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Using Gas Chromatography for Indoor-Air Quality Control in Conservation and Renovation Studios
Autorzy:
Ligor, T.
Gorczyca, P.
Buszewski, B.
Powiązania:
https://bibliotekanauki.pl/articles/90290.pdf
Data publikacji:
2005
Wydawca:
Centralny Instytut Ochrony Pracy
Tematy:
volatile organic compounds (VOCs)
air analysis
gas chromatography
occupational exposure
sample preparation
chromatografia gazowa
zagrożenia chemiczne
jakość powietrza
analiza powietrza
kontrola powietrza
Opis:
Investigations were carried out in the Department of Conservation of Painting and Polychrome Sculpture and in the Screen Printing Studio of the Faculty of Art at Nicolaus Copernicus University. Concentration of the vapours of organic solvents was measured in 2 workshops: the Art Conservation Studio and the Screen Printing Studio. This study attempts to evaluate the work environment in both studios by analysing the concentration of vapour solvents over 5 to 7 years of measurements. Volatile solvents—aliphatic and aromatic hydrocarbons, alcohols, esters and ketones—were detected in investigated workplaces. These compounds have a wide range of applications in cleaning and removing old varnishes, lacquers and paints; inhalation is the main route of exposure. Vapour was collected using an active sampling method.
Źródło:
International Journal of Occupational Safety and Ergonomics; 2005, 11, 3; 251-261
1080-3548
Pojawia się w:
International Journal of Occupational Safety and Ergonomics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Indoor Air Quality in Offices and Classrooms in Public Utility Building - a Case Study
Autorzy:
Łuszczyńska, Katarzyna
Powiązania:
https://bibliotekanauki.pl/articles/27314787.pdf
Data publikacji:
2022
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
indoor air quality
bioaerosol
microorganisms
fungi
jakość powietrza w pomieszczeniach
bioaerozol
mikroorganizmy
grzyby
Opis:
A microbiological analysis of indoor air quality in offices, lecture rooms, and hallways in a public utility building has been carried out in the Lubuskie Voivodship (Poland). In one of the storage rooms, the presence of fungi on the building partition was found in the place of water infiltration as a result of a technological failure in the building. A total of 17 nonresidential interiors were examined. The total number of psychrophilic and mesophilic bacteria and the total number of fungi were sampled by the collision method with the air sampler. A qualitative analysis has been performed of fungi present in the indoor air and from building partition of the studied interiors. A total of 11 species of fungi have been specified. Relative humidity and air temperature were measured with a hygrometer. The studies showed that the number of psychrophilic bacteria in indoor air was in the range 0-730 CFU/m3 , while the number of mesophilic bacteria was slightly higher (0-896 CFU/m3 ). A high level of contamination and a large number of fungi (734 CFU/m3 ) were found in the indoor air of storage room, where the problem of biodeterioration of building partitions occurred. In the remaining rooms, the level of microorganisms was low or moderate. Microbiological tests of the outdoor air (background) did not reveal an excessive number of microorganisms in the air.
Źródło:
Civil and Environmental Engineering Reports; 2022, 32, 3; 228--239
2080-5187
2450-8594
Pojawia się w:
Civil and Environmental Engineering Reports
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Numerical investigations of effect of indoor air quality on thermal comfort in residential buildings
Autorzy:
Krzaczek, M.
Tejchman, J
Powiązania:
https://bibliotekanauki.pl/articles/231320.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
budynek mieszkalny
jakość powietrza wewnętrznego
stężenie CO2
komfort cieplny
CFD
strefa oddychania osobista
obciążenie cieplne
wentylacja naturalna
residential building
indoor air quality
CO2 concentration
thermal comfort
personal breathing zone
heat load
natural ventilation
Opis:
The influence of the CO2 concentration in a local air zone in naturally ventilated residential houses on the residents’ behaviour was numerically investigated. A numerical two-dimensional CFD model of the indoor zone based on experiments performed by the authors was used. Different resident locations in the fluid domain and different inlet velocities imposed by wind were considered in simulations. The overall thermal comfort and IAQ indices were also calculated. The investigations results show that in contrast to the overall air quality, the local CO2 was strongly dependent upon the resident location, fresh air inlet velocity and ventilation system type.
Źródło:
Archives of Civil Engineering; 2014, 60, 1; 91-121
1230-2945
Pojawia się w:
Archives of Civil Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of road traffic on indoor air quality
Wpływ ruchu drogowego na jakość powietrza wewnętrznego
Autorzy:
Zender-Świercz, Ewa
Polański, Michał
Powiązania:
https://bibliotekanauki.pl/articles/2174677.pdf
Data publikacji:
2022
Wydawca:
Politechnika Świętokrzyska w Kielcach. Wydawnictwo PŚw
Tematy:
particulate matter PM2.5
particulate matter PM10
Indoor Air Quality
road traffic
pyły zawieszone PM2.5
pyły zawieszone PM10
jakość powietrza wewnętrznego
ruch drogowy
Opis:
The quality of air that people breathe has become a very important parameter of quality of life. Pollution contributes to numerous diseases, problems with the absorption of knowledge, and also reduces work efficiency. The article attempts to find the relationship between road traffic and indoor air quality. The parameter used to assess air pollution was particulate matter (smog). The research was carried out in three localisations with different traffic volumes, in three places for each localisation, in the summer, autumn, and winter periods. It was found that in areas with heavy road traffic, this traffic causes an inflow of pollutants into the rooms. In low-traffic localisations, sources other than road traffic have a greater impact on the indoor air quality, especially in the cool periods (autumn, and winter)
Jakość powietrza, jakim oddycha człowiek, stała się bardzo istotnym parametrem jakości życia. Zanieczyszczenia przyczyniają się do licznych zachorowań, problemów z przyswajaniem wiedzy, a także obniżają wydajność pracy. W artykule podjęto próbę odnalezienia zależności pomiędzy natężeniem ruchu drogowego i jakością powietrza wewnętrznego. Parametrem, który wykorzystano do oceny zanieczyszczenia powietrza, był pył zawieszony (smog). Badania przeprowadzono w trzech lokalizacjach o różnym natężeniu ruchu, w trzech miejscach dla każdej lokalizacji, w okresach lato, jesień i zima. Stwierdzono, że w lokalizacji o dużym natężeniu ruchu pojazdów ruch ten powoduje napływ zanieczyszczeń do pomieszczeń. W lokalizacjach o małym natężeniu ruchu większy wpływ na jakość powietrza wewnętrznego mają inne niż ruch drogowy źródła, szczególnie w okresach chłodnych (jesień, zima).
Źródło:
Structure and Environment; 2022, 14, 4; 142--152
2081-1500
Pojawia się w:
Structure and Environment
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza jakości powietrza wewnętrznego w małym przedszkolu
Analysis of indoor air quality in a small kindergarten
Autorzy:
Gładyszewska-Fiedoruk, K.
Powiązania:
https://bibliotekanauki.pl/articles/271034.pdf
Data publikacji:
2010
Wydawca:
Centralny Ośrodek Badawczo-Rozwojowy Aparatury Badawczej i Dydaktycznej, COBRABiD
Tematy:
wentylacja
jakość powietrza
przedszkola
ventilation
air quality
kindergarten
Opis:
Najczęściej w przedszkolach człowiek zaczyna swoją edukację. Dzieci spędzają w nich od pięciu do dziesięciu godzin dziennie. Dlatego ważna jest jakość powietrza wewnętrznego. Najczęściej stosowanym systemem wentylacji w przedszkolach jest wentylacja naturalna. Dokładniej wentylacja grawitacyjna kanałowa wspomagana okresowym wietrzeniem. W badanym przedszkolu rano stężenie dwutlenku węgla nie przekracza dopuszczalnych norm. Po południu stężenia dwutlenku węgla są znacznie przekroczone - maksymalnie o 190%. Temperatura i wilgotność powietrza znajdują się w granicach normy. Rozszczelniając lub otwierając okna doprowadzamy do pomieszczeń powietrze zewnętrzne, poprawiamy w ten sposób działanie wentylacji grawitacyjnej, poprawiamy jakość powietrza wewnętrznego.
Formal education usually begins in kindergarten. Children spend five to ten hours a day there, so indoor air quality is of paramount importance. Natural ventilation (or to be more precise gravitational channel ventilation system) is by far the most common ventilation method in kindergartens; its efficiency is enhanced by airing the premises from time to time. In the kindergarten in question, carbon dioxide concentration in the morning does not exceed the permissible level. In the afternoon, however, this level is considerably exceeded (by as much as 190%). Temperature and humidity stay within the acceptable range of values. Thanks to unsealing or opening the windows, outdoor air penetrates into the rooms, which boosts the functioning of the gravitational ventilation system thus improving indoor air quality.
Źródło:
Aparatura Badawcza i Dydaktyczna; 2010, 15, 2; 9-14
2392-1765
Pojawia się w:
Aparatura Badawcza i Dydaktyczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ adsorpcji zanieczyszczeń na jakość powietrza w pomieszczeniach
Influence of pollutants adsorption on indoor air quality
Autorzy:
Sowa, J.
Powiązania:
https://bibliotekanauki.pl/articles/362724.pdf
Data publikacji:
2007
Wydawca:
Instytut Fizyki Budowli Katarzyna i Piotr Klemm
Tematy:
jakość powietrza
adsorpcja
modelowanie
węgiel aktywny
air quality
adsorption
modeling
activated carbon
Opis:
W wielu przypadkach ograniczenie się jedynie do procesów adwektywnych przy modelowaniu jakości powietrza prowadzi do znacznych błędów. W artykule przedstawiono podstawowe zależności uproszczonego modułu adsorpcji, który mogły być stosowany z klasycznymi modelami jakości powietrza w skali makro. Przeanalizowano także wpływ adsorp- cji zanieczyszczeń powietrza na stężenia zanieczyszczeń dla hipotetycznego pomieszczenia biurowego przy różnych założeniach. Na podstawie przeprowadzonych analiz, a także na podstawie badań literaturowych, przestawiono uwagi odnośnie wpływu adsorpcji zanieczyszczeń na jakość powietrza w pomieszczeniach.
In many cases limitation just to advective processes during modelling indoor air quality leads to substantial errors. The paper presents basic relations of simplified adsorption model, that could be applied together with classic indoor air quality models of macro scale. The behaviour of hypothetical office has been analysed for different combination of assumptions. On the base of both performed analysis and literature studies some qualitative remarks have been formulated.
Źródło:
Fizyka Budowli w Teorii i Praktyce; 2007, T. 2; 251-254
1734-4891
Pojawia się w:
Fizyka Budowli w Teorii i Praktyce
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena mikrobiologiczna jakości powietrza w zakładach piekarniczych
The assessment of microbiological indoor air quality in bakeries
Autorzy:
Wołejko, E.
Kowaluk-Krupa, A.
Wydro, U.
Butarewicz, A.
Jabłońska-Trypuć, A.
Piekut, J.
Dec, D.
Łoboda, T.
Powiązania:
https://bibliotekanauki.pl/articles/399933.pdf
Data publikacji:
2016
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
piekarnie
bakterie
grzyby
zanieczyszczenie powietrza
bacteria
fungi
indoor air quality
bakeries
Opis:
Celem niniejszej pracy była ocena stanu jakości mikrobiologicznej powietrza w zakładach piekarniczych zlokalizowanych na terenie województwa podlaskiego. Badania wykonano jesienią 2014 roku na terenie trzech zakładów piekarniczych. Próby powietrza pobierano metodą zderzeniową z użyciem próbnika powietrza MAS-100 (Merck, Niemcy). Mikrobiologiczne badania powietrza obejmowały oznaczenie ogólnej liczby bakterii psychrofilnych i mezofilnych, bakterii wskaźnikowych tj. bakterii z gatunku Pseudomonas fluorescens, gronkowców mannitolododatnich i manitoloujemnych oraz grzybów pleśniowych znajdujących się w powietrzu atmosferycznym. Zanieczyszczenie powietrza wewnętrznego w badanych piekarniach pod kątem mikrobiologicznym różniło się w zależności od rodzaju lokalizacji zakładu produkcyjnego. Stężenia występujących wewnątrz zakładów bakterii mezofilnych i Staphylococcus mannitolododatnich oraz mannitoloujemnych przekraczały wartości graniczne określone dla powietrza niezanieczyszczonego. Nie odnotowano natomiast w analizowanych piekarniach nadmiernego zanieczyszczania powietrza grzybami pleśniowymi. Najwyższą liczbę grzybów w powietrzu wykryto w piekarni 1, natomiast w pozostałych piekarniach ich liczba utrzymywała się na poziomie czystego powietrza atmosferycznego.
The aim of this study was to assess microbiological indoor air quality of selected bakeries located in the region of Podlasie. The microbiological studies were conducted in autumn in 2014 in three selected bakeries. Microbiological air counts were measured by impaction using an air sampler MAS-100 NT. The microbiological air studies, comprised the determination of the total number of psychrophilic and mesophilic bacteria, namely indicator bacteria such as: bacteria of the species Pseudomonas fluorescens, mannitol-positive and mannitol-negative Staphylococc, the total number of bacteria from the Enterobacteriaceae family and fungi found in atmospheric air. The results of the study of indoor air polluted with the analyzed groups of microorganisms differed depending on the type of test air and the location of the manufacturing plant. In the plants, the concentration of mesophilic bacteria and mannitol–positive and mannitol-negative Staphylococcus exceeded the limit values of unpolluted air, according to the Polish Standard recommendations.
Źródło:
Inżynieria Ekologiczna; 2016, 47; 182-188
2081-139X
2392-0629
Pojawia się w:
Inżynieria Ekologiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Klasyfikacja jakości powietrza wewnętrznego z zastosowaniem logiki rozmytej
CLASSIFICATION OF INDOOR AIR QUALITY USING FUZZY LOGIC
Autorzy:
SZCZUREK, Andrzej
MACIEJEWSKA, Monika
Powiązania:
https://bibliotekanauki.pl/chapters/1965450.pdf
Data publikacji:
2016
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Opis:
Jakość powietrza wewnętrznego (IAQ) charakteryzuje fizyczny, chemiczny oraz biologiczny stan powietrza w pewnym miejscu i czasie. Informacja o niej jest bardzo potrzebna. Wielkość ta nie jest jednak mierzalna instrumentalnie w sposób bezpośredni. Jedną z możliwości określenia IAQ jest wykorzystanie modelu jej zależności od innych mierzalnych wielkości. W tej pracy rozważono możliwość zastosowania logiki rozmytej do klasyfikacji jakości powietrza wewnętrznego. Klasyfikację przeprowadzono na podstawie trzech paramentów powietrza wewnętrznego: temperatury, wilgotności względnej i stężenia ditlenku węgla. Model rozmyty wykorzystuje wiedzę ekspercką o związku między tymi parametrami a odczuciami człowieka. Porównano wyniki uzyskane z wykorzystaniem modeli bazujących na logice klasycznej i na logice rozmytej. W tym celu wykorzystano dane z monitoringu powietrza w przykładowym pomieszczeniu. Z przedstawionych rezultatów i ich dyskusji wynika, że zastosowana metoda jest dobrą propozycją rozwiązania problemu klasyfikacji jakości powietrza wewnętrznego.
Indoor air quality (IAQ) characterizes physical, chemical and biological state of air in a defined location and time. This quantity is not measurable with analytical methods. One of alternative approaches applied for its determination utilizes the fact that IAQ depends on many factors and those dependencies may be modelled. In this work we considered application of fuzzy logic to the classification of indoor air quality. The classification was carried out based on three parameters: temperature, relative humidity and carbon dioxide concentration. Fuzzy model utilized an expert knowledge about the relationship between these factors and human perception of the conditions around him. We compared results of classification obtained with classical, binary logic and fuzzy logic. Air monitoring data from an exemplary room was utilized for this purpose. Based on the presented results and their discussion, the applied method is an interesting option for solving a problem of indoor air quality classification.
Źródło:
Powietrze atmosferyczne. Jakość – zagrożenia – ochrona; 281-289
9788374939423
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies