Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "electric power networks" wg kryterium: Wszystkie pola


Tytuł:
Methods of voltage unbalance estimation in electric power networks
Autorzy:
Olczykowski, Z.
Wąsowski, A.
Powiązania:
https://bibliotekanauki.pl/articles/262813.pdf
Data publikacji:
2006
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie
Tematy:
voltage unbalance
symmetric component
differential coefficient
differential angle
Opis:
Methods of voltage unbalance estimation based on the theory of symmetrical components and the method of differential — angular coefficients of asymmetry have been discussed. It has been proposed the last one to estimate the asymmetry of square absolute voltage value, as useful for distorted processes.
Źródło:
Electrical Power Quality and Utilisation. Journal; 2006, 12, 2; 71-76
1896-4672
Pojawia się w:
Electrical Power Quality and Utilisation. Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wahania napięcia w wiejskich sieciach elektroenergetycznych
Voltage fluctuations in rural electric power networks
Autorzy:
Trojanowska, M.
Nęcka, K.
Powiązania:
https://bibliotekanauki.pl/articles/291442.pdf
Data publikacji:
2009
Wydawca:
Polskie Towarzystwo Inżynierii Rolniczej
Tematy:
wiejska sieć elektroenergetyczna
wahanie napięcia
rural electric power network
voltage fluctuation
Opis:
W oparciu o wyniki pomiarów prowadzonych w wiejskich stacjach transformatorowych 15/0,4 kV i na końcach linii niskiego napięcia zasilających odbiorców wiejskich z terenów Małopolski przeprowadzono analizę wahań napięcia pod kątem zgodności z obowiązującymi przepisami. Stwierdzono, że chociaż wartość napięcia zasilającego nie przekracza wartości dopuszczalnej, to warunki zasilania odbiorców wiejskich ze względu na wahania napięcia nie zawsze są prawidłowe. Odnosi się to w szczególności do odbiorców przyłączonych w pobliżu końców linii zasilających. Z przeprowadzonych badań wynika, że przeciętny odbiorca wiejski może się spodziewać w ciągu dnia ok. 8 wahań napięcia o amplitudzie przekraczającej 5% wartości napięcia znamionowego sieci, przy średnim czasie ich trwania 1,3 s.
Results of measurements carried out at rural transformer stations 15/0.4 kV and at ends of low-voltage lines supplying rural consumers in Małopolska Province have been used to analyse voltage fluctuations from point of view of compliance with applicable regulations. It has been observed that although supply voltage value does not exceed admissible value, power supply conditions for rural consumers are not always correct due to voltage fluctuations. In particular, this applies to consumers connected to the network near ends of supply lines. Completed research proves that every day average rural consumer may expect approximately 8 voltage fluctuations with amplitude exceeding 5% of network rated voltage value, at their average duration 1.3 s.
Źródło:
Inżynieria Rolnicza; 2009, R. 13, nr 5, 5; 289-294
1429-7264
Pojawia się w:
Inżynieria Rolnicza
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wykorzystanie algorytmu Tabu Search do lokalizacji baterii kondensatorów w sieci elektroenergetycznej
Application of the Tabu Search algorithm for localization of capacitor banks in a power system
Autorzy:
Wicher, P.
Wilkosz, K.
Powiązania:
https://bibliotekanauki.pl/articles/397304.pdf
Data publikacji:
2011
Wydawca:
ENERGA
Tematy:
sieć elektroenergetyczna
kondensator
electric power networks
capacitor
Opis:
Artykuł traktuje o znajdowaniu najkorzystniejszej lokalizacji baterii kondensatorów w sieci elektroenergetycznej. Po ogólnym omówieniu rozwiązywania tego zadania autorzy skupili uwagę na wykorzystaniu algorytmu poszukiwania z tabu (Tabu Search). W dalszej części pracy znajdujemy zasady postępowania według algorytmu poszukiwania z tabu. Po tym zaprezentowano charakterystykę różnych metod znajdowania optymalnej lokalizacji baterii kondensatorów, których wspólną cechą jest stosowanie algorytmu poszukiwania z tabu. Na zakończenie artykułu dokonano porównania przedstawionych metod lokalizacji baterii kondensatorów.
The paper discusses the process of finding the most optimal locations for capacitor banks within a power network. After general presenting the solution of this task, the authors focused on the application of the tabu search algorithm. A further part of the paper presents rules for applying the tabu search algorithm to the considered task, and various methods for finding the optimal capacitor bank locations using that algorithm are presented. Finally, the previously presented methods for finding the optimal capacitor bank locations are compared.
Źródło:
Acta Energetica; 2011, 2; 67-73
2300-3022
Pojawia się w:
Acta Energetica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Pomiary synchroniczne w optymalnej pracy sieci elektroenergetycznych
Autorzy:
Golub, I. I.
Powiązania:
https://bibliotekanauki.pl/articles/397293.pdf
Data publikacji:
2011
Wydawca:
ENERGA
Tematy:
system elektroenergetyczny
sieci elektroenergetyczne
urządzenie PMU
electric power networks
Opis:
W niniejszej pracy przedstawiono dwa algorytmy wyznaczania minimalnej liczby urządzeń PMU (Moduły Pomiaru Fazora) w sieci elektroenergetycznej. Urządzenia tego typu umieszcza się w węzłach i liniach elektroenergetycznych w celu zapewnienia topologicznej obserwowalności systemu w warunkach normalnej pracy sieci oraz w celu utrzymania wiarygodności takiej obserwowalności w przypadku awarii poszczególnych łączy i urządzeń PMU. Opracowane algorytmy zaimplementowano w środowisku MATLAB. Ich efektywność potwierdzono obliczeniami wykonanymi dla dużej liczby testowych modeli IEEE oraz dla rzeczywistych systemów elektroenergetycznych.
Źródło:
Acta Energetica; 2011, 3; 15-21
2300-3022
Pojawia się w:
Acta Energetica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowanie formatu CIM w modelowaniu sieci elektroenergetycznej w systemie SYNDIS-PLANS
The application of the CIM format in the modelling of an electrical power system in the SYNDIS-PLANS System
Autorzy:
Zdun, Z.
Wawrzyniak, M.
Powiązania:
https://bibliotekanauki.pl/articles/397297.pdf
Data publikacji:
2011
Wydawca:
ENERGA
Tematy:
sieci elektroenergetyczne
system SYNDIS-PLANS
electric power networks
SYNDIS-PLANS system
Opis:
W artykule przedstawiono zastosowanie standardu CIM w modelowaniu sieci przesyłowej w systemie SYNDIS- PLANS. System SYNDIS jest systemem typu SCADA i został zintegrowany z pakietem PLANS, powszechnie stosowanym w KSE do wykonywania obliczeń i analiz rozpływowych. W elektroenergetyce stosowane są różne programy, które działają na podstawie własnych modeli danych. Wymiana danych pomiędzy różnymi pakietami jest utrudniona. Pojawiła się więc potrzeba opracowania wspólnego modelu danych, która znacznie upraszcza wymianę danych pomiędzy aplikacjami. Prace nad stworzeniem wspólnego opisu sieci elektroenergetycznej były prowadzone w EPRI i doprowadziły do standardu opisu sieci – modelu CIM (ang. Common Information Model). W referacie zaprezentowano podstawowe zasady modelowania zgodne ze standardem CIM, z opisem podstawowych klas CIM wykorzystanych w modelowaniu sieci przesyłowej w systemie SYNDIS-PLANS wraz z opisem przeglądarki elementów sieci elektroenergetycznej. Artykuł zawiera również opis sposobu integracji pakietu do obliczania rozpływów mocy PLANS z systemem SYNDIS. Przedstawiono też wykaz zastosowań pakietu SYNDIS- -PLANS w elektroenergetyce.
This paper presents the application of the CIM standard in the modelling of a transmission grid in the SYNDIS-PLANS system. The SYNDIS system is a SCADA type environment and has been integrated with the PLANS package, which is widely used in the NPS for calculation and analysis of power distribution. The electrical power engineering industry uses various programs the work of which is based on their proprietary data models. The data exchange between different packages is difficult. Hence there was a need for developing a common data model which greatly simplifies the data exchange between applications. The development work on the common definition of the electrical power system was conducted at EPRI and resulted in the standard system/grid description, i.e the CIM (Common Information Model). This paper presents the basic rules of modelling in compliance with the CIM standard, including the description of basic CIM classes used in the modelling of the transmission grid in SYNDIS-PLANS, supplemented by a description of the electrical power system elements browser. This article also describes the method of integrating the PLANS power distribution calculation package with the SYNDIS system. A list of SYNDIS-PLANS application in electrical power engineering is also provided.
Źródło:
Acta Energetica; 2011, 2; 83-90
2300-3022
Pojawia się w:
Acta Energetica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ zakłóceń w sieci elektroenergetycznej na momenty skrętne w wale turbozespołu dużej mocy
The effect of disturbances in the electrical power system on torque moments of the high-power turbine set shaft
Autorzy:
Wiśniewski, J.
Powiązania:
https://bibliotekanauki.pl/articles/397308.pdf
Data publikacji:
2011
Wydawca:
ENERGA
Tematy:
sieci elektroenergetyczne
zakłócenia
turbozespoły dużej mocy
electric power networks
noise
high-power turbine sets
Opis:
Ustalono parametry mechaniczne zespołu turbin i generatora mocy 1000 MW bloku referencyjnego, pracującego przy parametrach nadkrytycznych. Przy użyciu metody modalnej obliczono częstotliwości drgań własnych układu wirującego. Zbadano wartości momentów skrętnych, jakie mogą się pojawić w odcinkach wałów podczas zakłóceń w sieci elektroenergetycznej, takich jak bliskie zwarcia, działanie automatyki SPZ, synchronizacja lub oddziaływanie od strony sieci momentów elektromagnetycznych wprowadzających układ w drgania rezonansowe.
Mechanical parameters are determined for a set of turbines and power generator of 1000 MW of the reference power unit operated at super-critical parameters. The modal method is used to calculate the frequencies of intrinsic vibrations of the vibrating systems. The paper investigates the values of torqu moments which may occur in the sections of shafts upon disturbances in the electrical power system, e.g. near faults, action of automatic reclosing systems, synchronisation or interaction of electromagnetic moments from the grid side which introduce the system into resonance vibration.
Źródło:
Acta Energetica; 2011, 2; 75-81
2300-3022
Pojawia się w:
Acta Energetica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wybrane zagadnienia kompensacji mocy biernej w sieci dystrybucyjnej
Selected problems of the reactive power compensation in distribution networks
Autorzy:
Kulig, S.
Bąchorek, W.
Brożek, J.
Powiązania:
https://bibliotekanauki.pl/articles/266726.pdf
Data publikacji:
2013
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
sieci elektroenergetyczne
kompensacja mocy biernej
rozpływy mocy
electric power networks
reactive power compensation
load model
power flow
Opis:
Przesył mocy biernej w sieci elektroenergetycznej jest niezbędny do funkcjonowania urządzeń zasilanych napięciem przemiennym jednak wpływa on niekorzystne na parametry jej pracy. Jednym ze sposobów ograniczenia tego wpływu jest instalacja urządzeń do kompensacji mocy biernej. Moc tych urządzeń ustalana jest najczęściej na podstawie obciążenia szczytowego sieci, tak aby spełnione zostały wymagania w zakresie dyrektywnego współczynnika mocy tg. Często moc takich źródeł mocy biernej jest stała, z zatem nie jest dostosowywana do zmian obciążenia sieci. W dolinie obciążenia przy braku tzw. kompensacji nadążnej może wystąpić problem przekompensowania co wpływa na poziomy napięć sieci zasilających. W artykule przedstawia się wybrane problemy kompensacji mocy biernej w sieci dystrybucyjnej. Przedstawiono przykłady i wyniki analiz ilustrujące wpływ sposobu kompensacji mocy biernej w sieci rozdzielczej na warunki pracy sieci elektroenergetycznej.
In the paper, the selected problems of reactive power compensation in a distribution network are presented. Reactive power is indispensable for a proper functioning of alternating current devices. The negative influence of the transfer of reactive power on the working of an electric power system makes the electric power operators to reduce its consumption by determining the required value of the directive power factor in the consumer’s network. In order to meet the value of the directive factor, the consumers compensate the reactive power. If they decide to use the reactive power compensator for peak loads, it is likely that overcompensation will take place at low loads. In such cases, the load becomes a receiver of the reactive power. Such a load results in the increased voltage at the connection point even above the admissible levels. In the paper, the influence of the direction of change in the reactive power flow on the levels of voltage in an electric power system is analyzed.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2013, 36; 127-130
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Optimization of urban MV multi-loop electric power distribution networks structure using Artificial Intelligence methods
Autorzy:
Parol, M.
Baczyński, D.
Brożek, J.
Powiązania:
https://bibliotekanauki.pl/articles/205678.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Instytut Badań Systemowych PAN
Tematy:
electric power distribution networks
optimization of network structure
evolutionary algorithms
artificial neural networks
Opis:
Urban medium voltage (MV) electric power distribution networks are supplied with primary (HV/MV) substations. These networks supply secondary (MV/LV) transformer substations and are often built as closed structures - loop arrangements. The design problem of optimal urban MV distribution network structure consists of determining the number of primary substations, establishing the number of MV loops supplied with the primary substations, and assigning the secondary MV/LV transformer substations to the MV loops. The optimization task becomes especially complex when the number of the primary substations is greater than one. The minimum of total annual costs is sought. The total annual costs include: fixed (investment) costs, variable (operating) costs and supply-interruption costs. Typical constraints are also accounted for. The so defined optimization problem is a complicated mathematical problem in respect of computational effort. In order to resolve the mathematical model of the optimization problem, evolutionary algorithms and artificial neural networks have been used. Exemplary computational experiments have been executed on the model of urban MV multi-loop electric power distribution networks. The results from the evolutionary algorithm and the artificial neural network calculations have been compared.
Źródło:
Control and Cybernetics; 2012, 41, 3; 667-689
0324-8569
Pojawia się w:
Control and Cybernetics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Proces podejmowania decyzji o stanie elektroenergetycznych sieci zakładów górniczych w aspekcie jakości energii elektrycznej
The process of decision making as to the condition of the mining electric power networks in the scope of the quality of the electric power
Autorzy:
Jasiński, M.
Powiązania:
https://bibliotekanauki.pl/articles/131342.pdf
Data publikacji:
2017
Wydawca:
Uczelnia Jana Wyżykowskiego
Tematy:
jakość energii elektrycznej
JEE
proces decyzyjny
zasilanie zakładów górniczych
generacja rozproszona
odnawialne źródła energii
power quality
decision-making process
mining plant supply
distributed generation
renewable sources of energy
Opis:
Artykuł prezentuje sformalizowaną strukturę procesu decyzyjnego we wnioskowaniu o stanie elektroenergetycznych sieci zakładów górniczych na podstawie parametrów energii elektrycznej. Zaprezentowano schemat procesu oraz opisano poszczególne jego elementy z ukierunkowaniem na zakłady górnicze kopalni rud miedzi w Zagłębiu Miedziowym. Wskazano również potencjalne korzyści wynikające ze stosowania takiego procesu, ze szczególnym uwzględnieniem wspierania przyłączania nowych instalacji źródeł odnawialnych do sieci górniczych oraz poprawy bezpieczeństwa pracy górników.
The article presents a decision-making process structure of electric power network conditions supported by power quality data. The process towards to mining plant of cooper ore in Zagłębie Miedziowe. The article points pross of such process to development of renewable sources of energy locations to mining plant network and improvement of safety of miners work.
Źródło:
Zeszyty Naukowe Uczelni Jana Wyżykowskiego. Studia z Nauk Technicznych; 2017, 6; 111-117
2543-6740
Pojawia się w:
Zeszyty Naukowe Uczelni Jana Wyżykowskiego. Studia z Nauk Technicznych
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Measuring accuracy of electric energy in HV power networks
Autorzy:
Jałmużny, W.
Powiązania:
https://bibliotekanauki.pl/articles/262655.pdf
Data publikacji:
2005
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie
Tematy:
electric energy measuring
instrument transformers
measuring accuracy
Opis:
The article presents the effect of secondary circuits of inductive current and voltage transformers on measuring accuracy in HV power networks. The basic parameters of instrument transformers were defined, such as errors or rated output. The impedance effect of the leads connecting secondary terminals with measuring instruments and the impact of burden power on the energy measuring error were analyzed. The calculation samples illustrate the procedure when assessing energy (power) measuring error. The algorithm may be applied, with positive results, by the operating personnel of measuring circuits with instrument transformers.
Źródło:
Electrical Power Quality and Utilisation. Journal; 2005, 11, 1; 3-15
1896-4672
Pojawia się w:
Electrical Power Quality and Utilisation. Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Optymalizacja struktur elektroenergetycznych sieci promieniowych z wykorzystaniem algorytmów sztucznej inteligencji
Optimization of the structure of electric power radial networks with the use of AI algorithms
Autorzy:
Bąchorek, W.
Brożek, J.
Powiązania:
https://bibliotekanauki.pl/articles/377553.pdf
Data publikacji:
2012
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
struktury elektroenergetyczne sieci promieniowych
elektroenergetyczna sieć promieniowa
algorytm genetyczny
AG
algorytm symulowanego wyżarzania
SW
sztuczna inteligencja
Opis:
W artykule przedstawiono metodę optymalizacji projektowania struktur dwunapięciowych elektroenergetycznych sieci promieniowych. Metoda wykorzystuje algorytm genetyczny (AG) i algorytm symulowanego wyżarzania (SW). Oba algorytmy optymalizują tą samą funkcję celu. Funkcję celu stanowi koszt roczny sieci elektroenergetycznej, który na etapie działania algorytmów jest minimalizowany. Działanie każdego algorytmu z osobna generuje, w czasie możliwym do przejęcia, suboptymalną strukturę sieci. Uzyskanie takich samych rozwiązań dwoma algorytmami zwiększa prawdopodobieństwo, że otrzymana struktura sieci promieniowej jest strukturą optymalną w sensie przyjętej funkcji celu. W metodzie algorytmy wykorzystują przemiennie, jako dane wejściowe, najlepsze uzyskane rozwiązania struktur sieci. W artykule przedstawiono krótki opis algorytmów oraz przykład obliczeniowy ilustrujący zastosowanie opracowanej metody do optymalizacji modelowej struktury elektroenergetycznej sieci promieniowej.
In the paper the method for optimizing the design process of the structures of two-voltage electric power radial networks is presented. The method takes advantage of a genetic algorithm (GA) as well as a simulated annealing algorithm (SA). Both algorithms minimize the same aim function, which is the annual cost of the electric power network. The execution of each of the algorithms generates - within the same acceptable period of time - a suboptimal structure of the network. If the same result is obtained through the utilization of both methods, the probability increases that the obtained network structure is optimal against the accepted aim function. The implemented algorithms use interchangeably - as the input data - the best obtained network structures. In the paper there is also presented an example illustrating the application of the developed computer program to the optimization of a model structure of an electric power radial network.
Źródło:
Poznan University of Technology Academic Journals. Electrical Engineering; 2012, 70; 134-142
1897-0737
Pojawia się w:
Poznan University of Technology Academic Journals. Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Non - productive losses of electric power in the networks of traction power supply of main railways
Autorzy:
Kostin, Nickolai
Mishchenko, Tatyana
Petrov, Andrey
Reutskova, Oksana
Powiązania:
https://bibliotekanauki.pl/articles/34655961.pdf
Data publikacji:
2011
Wydawca:
Sieć Badawcza Łukasiewicz - Poznański Instytut Technologiczny
Opis:
A new method of correlation functions, determinations of power indexes and non-productive (additional) losses of electric power in the traction electric systems of direct-current have been suggested. Non-productive losses have been calculated for a number of feeder areas. It has been shown that these losses are 6... 15% of electric power consumed by electric train.
Źródło:
Rail Vehicles/Pojazdy Szynowe; 2011, 3; 13-16
0138-0370
2719-9630
Pojawia się w:
Rail Vehicles/Pojazdy Szynowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Back-up short circuit protection in underground medium voltage networks
Rezerwowanie zabezpieczeń zwarciowych w kopalnianych sieciach średniego napięcia
Autorzy:
Boron, S.
Joostberens, J.
Powiązania:
https://bibliotekanauki.pl/articles/1361905.pdf
Data publikacji:
2015
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
zabezpieczenia zwarciowe
kopalniane sieci elektroenergetyczne
układy elektroenergetyczne
elektroenergetyka kopalniana
górnicze sieci średniego napięcia
automatyka zabezpieczeniowa w elektroenergetyce
short-circuit protection
electric power networks in mines
electric power systems
electric power engineering in mines
mining power supply networks
protection automation in electric power engineering
Opis:
The paper presents issues related to the implementation of back-up short-circuit protection in the final sections of an underground medium voltage distribution network. The difficulties may arise from regulatory requirements regarding the operation time of protection devices in potentially explosive areas and relatively low values of short-circuit currents compared with load currents. Sample calculations results have been presented to illustrate the problems of selecting current settings of short-circuit protection. A method to overcome these problems by using transformer stations with a circuit breaker on the primary side has been shown.
W artykule przedstawiono trudności związane z z rezerwowaniem zabezpieczeń przed skutkami zwarć międzyfazowych w końcowych odcinkach dołowych sieci średniego napięcia. Trudności te mogą wynikać z wymagań normatywnych dotyczących czasu działania zabezpieczeń w pomieszczeniach zagrożonych wybuchem oraz stosunkowo niewielkich wartości prądów zwarciowych w porównaniu z prądami roboczymi. Zaprezentowano przykładowe wyniki obliczeń ilustrujące problemy doboru nastaw zabezpieczeń zwarciowych oraz przedstawiono sposób wyeliminowania tych problemów przez zastosowanie stacji transformatorowych z wyłącznikiem po stronie GN.
Źródło:
Mining – Informatics, Automation and Electrical Engineering; 2015, 53, 3; 5-11
2450-7326
2449-6421
Pojawia się w:
Mining – Informatics, Automation and Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of the effect of characteristic parameters of a distribution transformer on economic management of electric power transmission in low-voltage networks
Autorzy:
Nawrowski, R.
Stein, Z.
Zielińska, M.
Powiązania:
https://bibliotekanauki.pl/articles/97588.pdf
Data publikacji:
2012
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
electric power transmission
distribution transformer
electrical energy
Opis:
The paper presents an attempt of mathematical description of the effect of, among others, such parameters of modern energetic transformers as magnetizing current or power loss in the core on the power loss and reactive power, in case of power transmission in the distribution networks, particularly of low-voltage.
Źródło:
Computer Applications in Electrical Engineering; 2012, 10; 299-307
1508-4248
Pojawia się w:
Computer Applications in Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Algorytmiczna realizacja oceny wpływu odnawialnych źródeł energii na niezawodność sieci elektroenergetycznej
Алгоритмічна реалізація оцінювання впливу відновлюваних джерел елекроенергії на надійність електричних мереж
Algorithmic realization impacts assessment for renewable sources electric power on reliability electrical networks
Autorzy:
Sobczuk, D.
Powiązania:
https://bibliotekanauki.pl/articles/407811.pdf
Data publikacji:
2015
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Tematy:
niezawodność bilansu energetycznego odnawialne źródła energii
niezawodność systemu
балансова надійність відновлювальні джерела
режимна надійність
carrying reliability renewable energy sources
operating reliability
Opis:
W celu efektywnej eksploatacji rozproszonych źródeł energii i ich kompleksowego wykorzystania w złożonych sieciach elektroenergetycznych przeprowadzono badanie ich właściwości, powstałych w wyniku współdziałania w systemie elektroenergetycznym. Algorytm oceniania wskaźników systemu niezawodności zapewnia wyznaczenie stanu ustalonego. Wyniki obliczeń stanu ustalonego pozwalają na analizę wartości napięć w węzłach sieci oraz odchylenia strat mocy czynnej względem wartości ustalonych normami. Przeprowadzono zaawansowaną analizę dziennych wykresów na podstawie informacji otrzymanej z systemu zdalnego odczytu (АСКОЕ).
З метою ефективної експлуатації розосереджених джерел електроенергії та їх комплексного використання в електричних мережах енергосистем проведені дослідження їх особливостей, які виникають в результаті сумісної роботи в складі електроенеретичної системи. Алгоритм оцінювання показників режимної надійності передбачає розрахунок усталеного режиму. За результатами розрахунків усталеного режиму аналізуються значення рівнів напруги у вузлах мережі та відхилення втрат активної потужності по відношенню до нормативного значення. Розширені можливості аналізу добових графіків шляхом використання інформації отриманої з АСКОЕ.
For the effective operation of distributed energy sources and their use in complex electrical power networks, studies their properties, resulting from joint work in the electric power system. Algorithm of performance assessment regime provides reliability normal mode calculation. The calculations steady mode analyzes the significance of voltage levels at the nodes of the network and the deviation of active power losses in relation to the required value. Advanced analysis of daily schedules by using information obtained from automated system of commercial accounting of electric power.
Źródło:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska; 2015, 1; 93-100
2083-0157
2391-6761
Pojawia się w:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies