Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "usuwanie azotu" wg kryterium: Temat


Wyświetlanie 1-13 z 13
Tytuł:
Usuwanie azotu amonowego z wód podziemnych w procesie dwustopniowej biofiltracji na złożach chalcedonitowych
Removal of ammonia nitrogen from groundwater on chalcedony deposits in two-stage biofiltration process
Autorzy:
Papciak, D.
Kaleta, J.
Puszkarewicz, A.
Powiązania:
https://bibliotekanauki.pl/articles/1819099.pdf
Data publikacji:
2013
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
usuwanie azotu
wody podziemne
biofiltracja
water treatment
biofiltration
Opis:
This paper presents an evaluation of the effectiveness of the removal of ammonia nitrogen from the water with oversize content of iron and manganese. The study was conducted using a two-stage biofiltration process on chalcedony beds. Biofilters operated in series, with counter-gravity flow at the first stage and the second stage gravity biofiltration. The chalcedony bed working at first stage was pre-activated with 0,3% KMnO4 in order to increase the efficiency of manganese removal. The test system was supplied with model solution made on the basis of a tap water with the addition of iron(II) 1g Fe/m3, manganese(II) 1 g Mn/m3, and ammonium 1,15-3,6 g N/m3 The results obtained during the study confirm that the biological processes of water treatment using a two-stage biofiltration through the chalcedony bed are effective in the removal of ammonia nitrogen from groundwater. Despite the diversification of mechanisms to remove these pollutants, the results indicate that the removal of ammonia nitrogen and manganese from water are competitive processes. The presence of manganese affects on the process of nitrification and ammonia nitrogen removal efficiency, and nitrification process may interfere with the effectiveness of manganese removal from water during formation of nitrification deposits. It was found that the presence of both iron and manganese affects the efficiency of the removal of ammonium and formation time of biofilm. Chemical activation biofilter of first stage had an impact on the efficiency of removal of ammonium and manganese ions, and the analysis of content of these pollutants shows that up to 10 day the chemical oxidation processes were dominated in working bed. It is difficult, however, explain the fact that in the second step of biofiltration manganese was removed with high efficiency from the outset of experiment, despite the lack of chemical activation. Previous studies have shown little effectiveness in removing manganese on the type chalcedony. A single-stage of biofiltration used in study was insufficient to carry out the nitrification process and obtain potable water for human consumption. After the first stage biofiltration water did not satisfy the requirements in terms of nitrite, and manganese. The increase in contact time through the use of second-stage of biofiltration allowed to obtain water that meets all the requirements for drinking water. Time for nitrifying chalcedony biofilter to reach full capacity was 64 days. The balance of nitrogen compounds and oxygen consumption shows the complexity of biofiltration. The real oxygen consumption was significantly lower than suggested by stoichiometric calculations and amounted to about 2 mg O2/dm3 per each mg of nitrogen removed, which can suggest that the removal of ammonia nitrogen on researched bed can occur not only in the process of nitrification. The Anammox process as well as the assimilation may have the contribute in the removal of ammonia nitrogen in the biofiltration process.
Źródło:
Rocznik Ochrona Środowiska; 2013, Tom 15, cz. 2; 1352-1366
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wykorzystanie zeolitu do usuwania jonów azotu amonowego z cieczy osadowej
Use of zeolite for removal of ammonium nitrogen from reject water
Autorzy:
Sperczyńska, E.
Powiązania:
https://bibliotekanauki.pl/articles/297762.pdf
Data publikacji:
2016
Wydawca:
Politechnika Częstochowska. Wydawnictwo Politechniki Częstochowskiej
Tematy:
ammonia nitrogen removal
reject water
zeolite
usuwanie azotu amonowego
ciecze osadowe
zeolity
Opis:
Research work on the possibilities of adsorption/ion exchange processes use for ammonium nitrogen removal form reject water was performed. The aim of the study was to evaluate the effectiveness of ammonium nitrogen removal from reject water separated after methane digestion. Zeolites were used from ammonium nitrogen removal. Reject water was taken from municipal wastewater treatment plant of PE over 100 000. They were sampled after mechanical dewatering of digested sewage sludge. High concentrations of biogens were stated in the reject water: nitrogen concentration was equal to 893.4 mg N-NH4+/dm3, whereas phosphorus was equal to 40.8 mg P-PO43-/dm3. COD value was 276 g O2/dm3. Reject water had brown colour and alkaline pH (pH = 7.92). Turbidity of reject water was equal to 94.1 NTU. Removal of ammonium nitrogen was performed on zeolite bed of 50 cm high and with diameter of 3.4 cm. At first model reject water was introduced into the bed. Concentration of ammonium nitrogen in model reject water was equal to 100 mg N-NH4+/dm3 (filtration velocity 5.0 m/h). Removal efficiency of ammonium nitrogen was in the range 80÷90%. Simultaneously increase in turbidity of treated model water was observed. Further experiment were performed with reject water taken from wastewater treatment plant. Filtration velocities were equal to 3.4 and 12.7 m/h. At higher filtration velocity ammonium nitrogen removal was in the range of 20 and 52%. For the last three samples removal efficiency has set at level of 30%, As filtration velocity was lower removal efficiency of ammonium nitrogen increased to 30÷70% in subsequent portions of filtrate. Stabile results were obtained for the fifth portion of filtrate. Removal of ammonium nitrogen from reject water on zeolite beds depends on filtration velocity. As filtration velocity decreases removal efficiency of ammonium nitrogen increases. Stabile results of ammonium nitrogen removal efficiency from reject water by zeolite beds water at level of 30%. It must be emphasised that parameters of reject water differed during the experiment. As concentration of ammonium nitrogen decreased alkalinity, pH and turbidity increased. Turbidity increase was especially visible at low filtration velocities. The same trend was observed in the case of COD.
Badania prowadzono w kierunku określenia możliwości zastosowania procesu adsorpcji/ wymiany jonowej na zeolitach w celu usunięcia azotu amonowego z cieczy osadowych. Do badań wykorzystano ciecze osadowe pochodzące z odwadniania przefermentowanych komunalnych osadów ściekowych z oczyszczalni ścieków o RLM powyżej 100 000. Ciecze osadowe charakteryzowały się bardzo wysokimi stężeniami związków biogennych: azotu (893,4 mg N-NH4+/dm3) oraz fosforu (40,8 mg P-PO43-/dm3). Ponadto ciecze wyróżniały się wysoką brunatną barwą, odczynem zasadowym (pH = 7,92) oraz wysoką mętnością (94,1 NTU). Usuwanie azotu amonowego na złożu zeolitowym prawdzono w pierwszej kolejności dla cieczy modelowej o stężeniu około 100 mg N-NH4+/dm3. Uzyskano od 80 do 90% efektywność usunięcia N-NH4+. Jednocześnie zaobserwowano zwiększenie mętności filtratu. Następnie określono wpływ prędkości filtracji na efektywność usuwania jonów amonowych z cieczy osadowych. Badania prowadzono dla vf = 3,4 oraz 12,7 m/h. Przy wyższej prędkości filtracji uzyskano zmniejszenie zawartości azotu amonowego od 20 do 52%, natomiast przy niższej od 30 do 70% w kolejnych porcjach filtratu. Usunięcie azotu amonowego z cieczy osadowych w warunkach przepływowych jest uzależnione od prędkości filtracji; im mniejsza prędkość filtracji, tym bardziej zwiększa się efektywność usunięcia azotu amonowego. Uzyskano możliwość stabilnego usunięcia azotu amonowego z cieczy osadowych na złożu zeolitowym na poziomie nie większym niż 30%.
Źródło:
Inżynieria i Ochrona Środowiska; 2016, 19, 3; 391-399
1505-3695
2391-7253
Pojawia się w:
Inżynieria i Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Skuteczność eliminacji azotu w przydomowych oczyszczalniach z osadem czynnym
Effectiveness of elimination of nitrogen in domestic sewage treatment plants with activated sludge
Autorzy:
Bugajski, P.
Kaczor, G.
Bergel, T.
Powiązania:
https://bibliotekanauki.pl/articles/61685.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Stowarzyszenie Infrastruktura i Ekologia Terenów Wiejskich PAN
Tematy:
oczyszczalnie sciekow przydomowe
osady czynne
azot ogolny
temperatura sciekow
usuwanie azotu
skutecznosc oczyszczania
Opis:
Celem badań było określenie skuteczności usuwania związków azotu w dwóch przydomowych oczyszczalniach ścieków działających w oparciu o technologię osadu czynnego. Ponadto określono wpływ temperatury ścieków w reaktorach biologicznych na skuteczność eliminacji analizowanego wskaźnika. Analizowane obiekty to oczyszczalnia ścieków Turbojet EP-2 o przepustowości projektowanej od 1,2 do 1,8 m3·d-1, oraz oczyszczalnia Turbojet EP-4 o przepustowości projektowanej 3,5÷5,0 m3·d-1. W okresie badań oba obiekty były niedociążone hydraulicznie. Na podstawie badań prowadzonych w latach 2008-2010 stwierdzono, że średnie stężenia azotu ogólnego w ściekach surowych wynosiły 82,6 mgNog·dm-3 w oczyszczalni Turbojet EP-2 oraz 102,0 mgNog·dm-3 w oczyszczalni Turbojet EP-4, natomiast średnie stężenia azotu ogólnego w ściekach oczyszczonych wynosiły 30,2 mgNog·dm-3 w oczyszczalni Turbojet EP-2 i 65,5 mgNog·dm-3 w oczyszczalni Turbojet EP-4. W okresie badań stwierdzono duże wahania stężeń azotu ogólnego w ściekach oczyszczonych, które wynosiły od 12,2 do 77,1 mgNog·dm-3 w oczyszczalni Turbojet EP-2 i od 15,3 do 130,7 mgNog ·dm-3 w oczyszczalni Turbojet EP-4. Świadczy to o niestabilnie zachodzących procesach nitryfikacji i denitryfikacji. Duży wpływ na skuteczność procesów unieszkodliwiających azot miała temperatura ścieków w reaktorach biologicznych. Wpływ ten potwierdzono zależnością korelacyjną, która w oczyszczalni Turbojet EP-2 była wysoka (rxy=0,67) a w oczyszczalni Turbojet EP-4 bardzo wysoka (rxy=0,72). Skuteczność usuwania azotu ogólnego w oczyszczalni Turbojet EP-2 wyniosła średnio w okresie badań 61,3%, natomiast w oczyszczalni Turbojet EP-4 36,2%. W obu analizowanych obiektach w reaktorach biologicznych zaobserwowano duże wahania temperatury ścieków. Najniższe temperatury ścieków oscylujące w granicach 6÷8oC występowały w okresie 3 miesięcy w okresie rocznym, co przekładało się na niską skuteczność oczyszczania w tym okresie.
The aim of the study was to determine the effectiveness of the removal of nitrogen compounds in two domestic sewage treatment plants operate based on activated sludge technology. In addition, the effect of sewage temperature in the bioreactors analyzed the effectiveness of the elimination rate. Also analyzed the treatment Turbojet EP-2 with a capacity designed from 1.2 to 1.8 m3·d-1, and treatment Turbojet EP-4 with a capacity of 3.5÷5.0 designed m3·d-1. During the study period the two objects were hydraulically underloaded. Based on studies conducted in 2008-2010 found that the average concentration of total nitrogen in raw sewage were 82.6 mgNog·dm-3 in the treatment plant Turbojet EP-2 and 102.0 mgNog·dm-3 in the treatment Turbojet EP-4, the mean concentration of total nitrogen in treated wastewater were 30.2 mgNog·dm-3 in the treatment Turbojet EP-2 and 65.5 mgNog·dm-3 in the treatment Turbojet EP-4. During the study found large fluctuations in the concentrations of total nitrogen in treated wastewater, which ranged from 12.2 to 77.1 mgNog·dm-3 in the treatment Turbojet EP-2 and from 15.3 to 130.7 mgNog·dm-3 in the treatment Turbojet EP-4. This demonstrates the instability occurring processes of nitrification and denitrification. High impact on the percentage of disposal process was nitrogen temperature treatment in bioreactors. This effect was confirmed correlations, which in sewage Turbojet EP-2 was high (rxy=0.67) and treatment Turbojet EP-4 very high (rxy=0.72). The removal efficiency of total nitrogen in wastewater Turbojet EP-2 was on average 61.3% during the study period, while in treatment Turbojet EP-4 36.2%. In both study sites in the bioreactors seen large fluctuations in water temperature. The lowest sewage temperature is oscillating in the range of 6÷8°C occurred during the three months in the year, which translates into a low efficiency of treatment during this period.
Źródło:
Infrastruktura i Ekologia Terenów Wiejskich; 2013, 3/IV
1732-5587
Pojawia się w:
Infrastruktura i Ekologia Terenów Wiejskich
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania kinetyczne procesu denitryfikacji z dawkowaniem zewnętrznego źródła węgla z postaci produktów odpadowych z produkcji alkoholu
Kinetic investigations of denitrification with the addition of external carbon sources in the form of by products from alcohol production
Autorzy:
Kaszubowska, M.
Majtacz, J.
Mąkinia, J.
Czerwionka, K.
Kulbat, E.
Powiązania:
https://bibliotekanauki.pl/articles/372496.pdf
Data publikacji:
2011
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
denitryfikacja
osad czynny
usuwanie azotu
źródła węgla
denitrification
activated sludge
nitrogen removal
carbon sources
Opis:
Celem badań była ocena możliwości zastosowania produktów odpadowych z produkcji alkoholu (olejów fuzlowych) jako alternatywnego źródła węgla w procesie denitryfikacji. Dla porównania, w badaniach wykorzystano również ścieki oczyszczone mechanicznie (bez podczyszczania oraz podczyszczone w procesie koagulacji-flokulacji), jak również dwa konwencjonalne zewnętrzne źródła węgla (kwas octowy i etanol). Badania laboratoryjne obejmowały "konwencjonalny" pomiar szybkości denitryfikacji (z ang. NUR). Pomiary wykonano wykorzystując specjalny zestaw laboratoryjny składający się z dwóch równoległych reaktorów nieprzepływowych o pojemności 4 dm3 każdy. Badane oleje fuzlowe wpływały na poprawę szybkości procesu w stopniu porównywalnym do etanolu.
The aim of this study was evaluation of the feasibility of using byproducts from alcohol production (fusel oils) as an alternative carbon source for denitrification. For comparison, the settled wastewater (without further pretreatment and after coagulation-floculation) as well as two conventional external carbon sources (ethanol and acetic acid) were also investigated. Lab experiments comprised the conventional nitrate utilization rate (NUR) measurements. The experiments were carried out in a special lab apparatus consisting of two parallel batch reactors (V = 4 dm3 each). The effect of examined fusel oils was similar to ethanol.
Źródło:
Zeszyty Naukowe. Inżynieria Środowiska / Uniwersytet Zielonogórski; 2011, 141 (21); 78-86
1895-7323
Pojawia się w:
Zeszyty Naukowe. Inżynieria Środowiska / Uniwersytet Zielonogórski
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowanie sondy do pomiaru zawartości azotu amonowego i azotanowego jako elementu sterowania procesem oczyszczania ścieków
Implementation of the ammonium and nitrate sensor as an element of wastewater treatment process control
Autorzy:
Dereszewska, A.
Cytawa, St.
Powiązania:
https://bibliotekanauki.pl/articles/398941.pdf
Data publikacji:
2012
Wydawca:
Politechnika Białostocka. Oficyna Wydawnicza Politechniki Białostockiej
Tematy:
oczyszczanie ścieków
skuteczne sterowanie procesem
usuwanie azotu
wastewater treatment
efficient process control
nitrogen removal
Opis:
The paper presents the potential benefits of modification of the control system of wastewater treatment in the "Swarzewo" Municipal Sewage Treatment Plant. Currently, process control is based on the determined filling level of the reactor and wastewater aeration time, regardless the concentration of pollutants in the inflow. It results in insufficient degree of removal of nitrogen compounds from wastewater aeration and unnecessary aeration of wastewater already treated. It generates additional costs because of exceeded energy consumption and environmental fees as well. The plant energy balance can be improved by supporting the existing technology by analysis of key parameters of wastewater treatment. Due to the fact that the oxidation of nitrogen compounds is the longest process of sewage mineralization, that parameter can be used as an indicator of the necessary treatment time determination. The treatment plant control system based on the content of ammonium and nitrate allows to reduce 13,3% of the blower's energy consumption and to achieve stabilization of the outflow parameters of the treatment plant.
Źródło:
Ekonomia i Zarządzanie; 2012, 4, 1; 127-135
2080-9646
Pojawia się w:
Ekonomia i Zarządzanie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Nowe trendy w usuwaniu azotu amonowego ze ścieków: nitrytacja – anammox w niskiej temperaturze
new trends in ammonia nitrogen removal from wastewater: nitritation – anammox at low temperature
Autorzy:
Tomaszewski, M.
Cema, G.
Ziembińska-Buczyńska, A.
Powiązania:
https://bibliotekanauki.pl/articles/400316.pdf
Data publikacji:
2017
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
nitrytacja–anammox
usuwanie azotu amonowego
oczyszczanie ścieków
nitritation–anammox
ammonia nitrogen removal
wastewater treatment
Opis:
Proces częściowej nitryfikacji (nitrytacji) – anammox (beztlenowego utleniania azotu amonowego) znajduje coraz szersze zastosowanie w oczyszczaniu ścieków o wysokim ładunku azotu amonowego i wysokiej temperaturze (25–40°C). Podyktowane jest to optymalną temperaturą rozwoju bakterii anammox, która mieści się w zakresie od 30 do 40°C. Ze względu na korzyści płynące z wykorzystania procesu anammox do oczyszczania ścieków komunalnych, których temperatura znacznie odbiega od optymalnej dla procesu, coraz więcej uwagi poświęca się badaniom nad możliwościami efektywnego prowadzenia procesu nitrytacji – anammox w niższej temperaturze (10–20°C). W porównaniu do tradycyjnego systemu nitryfikacji – denitryfikacji, proces nitrytacji – anammox cechuje się niższym zapotrzebowaniem na tlen, niższym przyrostem osadu nadmiernego oraz brakiem zapotrzebowania na źródło węgla organicznego, co przekłada się na znaczne obniżenie kosztów eksploatacyjnych. W prezentowanej pracy dokonano przeglądu najnowszych badań i osiągnięć dotyczących zastosowania procesu nitrytacji – anammox w niskich temperaturach. Wykazały one, że możliwe jest skuteczne usuwanie azotu amonowego ze ścieków komunalnych w temperaturze 15°C w skali pilotażowej, a nawet 12°C w skali laboratoryjnej. Najlepsze rezultaty osiągane są dzięki zastosowaniu reaktorów sekwencyjnych i/lub ze złożem ruchomym, w których biomasa występuje w formie granul i/lub biofilmu, a także kombinacje tych technologii. Badania oparte na biologii molekularnej sugerują natomiast, że największe zdolności adaptacyjne do niskiej temperatury wykazują bakterie anammox z rodzaju Candidatus Brocadia. W dalszym ciągu wyzwaniem pozostaje jednak utrzymanie stabilnego procesu nitrytacji – anammox w temperaturze 10°C oraz sposób i czas adaptacji biomasy.
Partial nitrification (nitritation) – anammox (anaerobic ammonia oxidation) process is increasingly used to treat wastewater, characterized by a high nitrogen content and high temperature (25–40°C). It is connected with the optimal temperature of anammox bacteria, which is at the range between 30 and 40°C. Mainstream application of anammox for the municipal wastewater, characterized by lower temperature seems to be one of the most challenging, but profitable process. Thenceforth, the research performed in the field of the nitritation – anammox at low temperature (10–20°C) become more and more intense. Compared with the conventional nitrification – denitrification system, nitritation – anammox reduces oxygen demand, eliminates the need for organic carbon source and produces less excess sludge. As a result, it allows to a significant cost reduction. This paper reviews the most important and recent information in the field of nitritation – anammox process at low temperature. Effective nitrogen removal from the municipal wastewater was demonstrated at 15°C in a pilot scale and at 12°C in a laboratory scale reactor. The best performance is achieved in sequencing batch reactors and moving bed reactors with biofilm or granular biomass, as well as combinations of these technologies. Molecular biology studies shows that anammox bacteria of the genus Candidatus Brocadia may have the biggest predispositions to adapt to low temperature. However, temperature about 10°C, time and method of biomass adaptation are still the main challenges for stable and common nitritation – anammox process.
Źródło:
Inżynieria Ekologiczna; 2017, 18, 2; 175-179
2081-139X
2392-0629
Pojawia się w:
Inżynieria Ekologiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena usuwania związków węgla, azotu i fosforu w komunalnej oczyszczalni ścieków w Sokółce
Assessment of the removal of carbon, nitrogen and phosphorus in municipal wastewater treatment plants in Sokółka
Autorzy:
Ignatowicz, K.
Struk-Sokołowska, J.
Kazimierowicz, J.
Powiązania:
https://bibliotekanauki.pl/articles/908423.pdf
Data publikacji:
2013
Wydawca:
Fundacja Ekonomistów Środowiska i Zasobów Naturalnych
Tematy:
oczyszczanie ścieków
usuwanie węgla
usuwanie azotu
usuwanie fosforu
komunalna oczyszczalnia ścieków
wastewater treatment
carbon removal
nitrogen removal
phosphorus removal
municipal sewage treatment plant
Opis:
W sytuacji postępującej eutrofizacji wód w wielu krajach zauważalna staje się tendencja do zmiany filozofii podejścia do ich ochrony. Konieczność spełnienia obowiązujących wymagań odnośnie do jakości ścieków oczyszczonych skłania do poszukiwania sposobów intensyfikacji usuwania związków biogennych. W celu zapewnienia żądanego obniżenia stężenia związków biogennych obecnie stosowane są biologiczne metody usuwania azotu oraz biologiczne i chemiczne metody usuwania fosforu.
The aim of this study was to show changes in concentrations of organic compounds, nitrogen and phosphorus in wastewater by using activated sludge technology in sequential SBR reactors. Made of raw sewage samples, after mechanical treatment, the dephosphatation, while ¼, ½, ¾, and after complete nitrification, denitrification, and the effluent. Profiles plotted compounds of C, N and P. It has been shown that the sewage treatment plant in Sokółka and increased effects integrated removing the above-mentioned compounds.
Źródło:
Ekonomia i Środowisko; 2013, 4; 159-168
0867-8898
Pojawia się w:
Ekonomia i Środowisko
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Bilans ChZT w biologicznym oczyszczaniu ścieków osadem czynnym - cz. I. skala laboratoryjna
Cod balance in biological treatment of wastewater - part I - laboratory scale
Autorzy:
Myszograj, S.
Powiązania:
https://bibliotekanauki.pl/articles/372054.pdf
Data publikacji:
2010
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
bilans CzZT
węgiel organiczny
osad czynny
usuwanie azotu
balance of COD
organic carbon
activated sewage sludge
nitrogen removal
Opis:
W artykule przedstawiono metodę bilansowania ChZT w układach oczyszczania ścieków osadem czynnym. Sporządzono bilans ChZT dla laboratoryjnych układów technologicznych. Potwierdzono, że zbilansowanie ChZT możliwe jest wyłącznie dla reaktorów tlenowych lub układów anoksyczno/tlenowych.
In this article, the bases of COD balancing in aerobic, anoxic and anaerobic activated sludge systems were introduced. Literature data has been showing, that simulations of balances COD close 100% are possible for aerobic reactors or anoxic/aerobic systems. On systems including anaerobic zones the balance of COD is close maximally in 85%. It is suggested, that the "loss" COD, which becomes appointed in balances, is associated with the process of hydrolysis or the fermentation of organic matter. Inappropriate accepting the "loss" COD in modelling and optimization of activated sludge process, influences on the growth of aeration costs and quantity of sewage sludge.
Źródło:
Zeszyty Naukowe. Inżynieria Środowiska / Uniwersytet Zielonogórski; 2010, 140 (20); 102-111
1895-7323
Pojawia się w:
Zeszyty Naukowe. Inżynieria Środowiska / Uniwersytet Zielonogórski
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Emisja zanieczyszczeń do atmosfery a nowoczesne technologie, na przykładzie elektrowni Jaworzno III w Jaworznie
Pollutant emission to the atmosphere and high-technology on the ex ample of Jaworzno III power station in Jaworzno
Autorzy:
Wierzbińska, M
Szczotka, A
Powiązania:
https://bibliotekanauki.pl/articles/399731.pdf
Data publikacji:
2013
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
odsiarczanie
usuwanie tlenków azotu
odżużlanie
biomasa
desulfurization
NOx elimination
deslagging
biomass
Opis:
W artykule przedstawiono przykładowe działania zmierzające do ograniczenia emisji zanieczyszczeń pyłowych i gazowych ze spalania paliw w Elektrowni Jaworzno III w Jaworznie. Produkcja energii oparta jest tu na bazie spalania mieszanki węgla kamiennego i biomasy w stosunku 9:1, co zmniejsza zawartość siarki w gazach odlotowych. Zmniejszenie emisji pyłów, SO2 i NOx uzyskano dzięki modernizacjom technologicznym, a mianowicie uruchomieniu instalacji odsiarczania spalin, instalacji mokrego odżużlania, technologii redukcji tlenków azotu oraz instalacji podawania biomasy.
In this paper technologies of pollution elimination from waste gases in Jaworzno Power Station III are presented. Mixture of coal and biomass (9:1) is combusted there. In waste gases there are dust and gaseous pollutants which are eliminated using high-technology filters and technologies of desulfurization, NOx elimination and deslagging. Changes in pollution quantities before and after Power Station modernization are presented on graphs.
Źródło:
Inżynieria Ekologiczna; 2013, 33; 175-182
2081-139X
2392-0629
Pojawia się w:
Inżynieria Ekologiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modyfikacja obecnej postaci modelu osadu czynnego ASM 2d
Modification of the present form of the ASM 2d acivated sludge model
Autorzy:
Szetela, R.
Dymaczewski, Z.
Powiązania:
https://bibliotekanauki.pl/articles/237564.pdf
Data publikacji:
2002
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
oczyszczanie ścieków
oczyszczanie biologiczne
osad czynny
usuwanie fosforu
usuwanie substancji organicznych
usuwanie związków azotu
modelowanie matematyczne
Opis:
Pilot-scale investigations into nitrogen and phosphorus removal by the activated sludge process were carried out in the wastewater plant of Poznań. Under laboratory conditions, the following parameters were examined: Ammonia Utilization Rate (AUR), Nitrate Utilization Rate (NUR), Phosphorus Release Rate (PRR) and Phosphorus Uptake Rate (PUR) for the activated sludge coming from a pilot plant. With the results obtained it was possible to calibrate and verify the mathematical model describing the ASM 2d activated sludge for the pilot plant of interest. It was found that the predictions of phosphorus variations established in terms of the original ASM 2d model were inadequate when the untreated wastewater contained very high amounts of Volatile Fathy Acids (VFA). Despite the presence of VFA in the anoxic or oxic phase, phosphorus release terminated, followed by the initiation of phosphorus uptake, thus resulting in a rapid decrease of phosphates concentration in the solution. Under such conditions the ASM 2d model predicts further release of phosphates up to a complete VFA exhaustion. The proposed modification of the model includes the incorporation of two terms, Ko/(Ko+So) and Kno/(Kno+Sno), into the equation for the PHA storage rate, which results in the blocking of the process under oxic and anoxic conditions, respectively. With such modification it is possible to make the predictions of the model far more adequate to reality. In the study, consideration was also given to the problem of model calibration with respect to the denitrification effect.
Źródło:
Ochrona Środowiska; 2002, 1; 3-8
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Możliwości zwiększenia efektywności usuwania ze ścieków azotu i fosforu w oczyszczalni w Łopusznej
Enhancement possibilities of nitrogen and phosphorus removal from sewage in the treatment plant in Lopuszna
Autorzy:
Walega, A.
Plesinski, K.
Chmielowski, K.
Satora, S.
Powiązania:
https://bibliotekanauki.pl/articles/60924.pdf
Data publikacji:
2010
Wydawca:
Polska Akademia Nauk. Stowarzyszenie Infrastruktura i Ekologia Terenów Wiejskich PAN
Tematy:
oczyszczalnie sciekow
oczyszczalnia sciekow w Lopusznej
scieki
pierwiastki biogenne
azot
fosfor
oczyszczanie sciekow
usuwanie azotu
usuwanie fosforu
efektywnosc oczyszczania
ciagi technologiczne
procesy jednostkowe
modernizacja
symulacja komputerowa
model ASM2d
Opis:
W pracy dokonano analizy możliwości modernizacji ciągu technologicznego oczyszczalni ścieków w Łopusznej w aspekcie zwiększenia intensywności usuwania zanieczyszczeń biogennych. Wysoka efektywność pracy badanej oczyszczalni jest ważna w aspekcie ochrony wód kaskady zbiorników retencyjnych Czorsztyn-Niedzica-Sromowce Wyżne przed nadmiernym zanieczyszczeniem. Ocenę możliwości modernizacji oczyszczalni przeprowadzono na podstawie wielu symulacji komputerowych bazujących na modelu ASIM2d. Model ten uwzględnia 21 procesów jednostkowych, które zostały podzielone na: procesy hydrolizy, procesy zachodzące z udziałem bakterii heterotroficznych XH, procesy zachodzące z udziałem bakterii akumulujących polifosforany XPAO, procesy zachodzące z udziałem bakterii nitryfikujących XAUT i procesy chemiczne. Analiza wykazała, że niska efektywność usuwania biogenów na przedmiotowej oczyszczalni wynika z braku recyrkulacji osadu czynnego do komory anaerobowej, w wyniku czego nie zachodzi w wystarczającym stopniu proces biologicznej defosfatacji. Sytuacja ulegnie poprawie w przypadku korekty ciągu recyrkulacji wewnętrznej i zewnętrznej oraz włączeniu komory anaerobowej do ciągu technologicznego przedmiotowej oczyszczalni.
The paper presents analysis of modernization possibilities of the technological chain in the sewage treatment plant in Lopuszna concerning removal of biogenic pollutants. High operation effectiveness of the analyzed treatment plant is important regarding the protection of water in the cascade of Czorsztyn-Niedzica- Sromowce Wyzne reservoirs against the excessive pollution. The assessment of modernization possibilities of the treatment plant was based on the number of computer simulations upon the ASIM2d model. This model includes 21 separate processes, which were divided into: hydrolysis processes, processes with heterotrophic bacteria XH, processes with poliphosphates’ accumulating bacteria XPAO, processes with nitrifiers XAUT and chemical processes. The analysis revealed that low effectiveness of biogenic substance removal in the objective treatment plant results from the lack of activated sludge recirculation into the anaerobic chamber which causes that the biological dephosphatation process is not sufficient enough. The situation will change if the internal and external recirculation chain is corrected and the anaerobic chamber is included in the technological chain of the objective sewage treatment plant.
Źródło:
Infrastruktura i Ekologia Terenów Wiejskich; 2010, 01
1732-5587
Pojawia się w:
Infrastruktura i Ekologia Terenów Wiejskich
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Znaczenie złóż hydrofitowych z pionowym i poziomym przepływem ścieków i filtratu w przemianach frakcji materii organicznej i azotu
Importance of Vertical and Horizontal Hydrophytes Beds for Organic and Nitrogen Transformation and Removal During Treatment of Wastewater and Reject Water
Autorzy:
Gajewska, M.
Powiązania:
https://bibliotekanauki.pl/articles/1818618.pdf
Data publikacji:
2015
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
usuwanie azotu
frakcje koloidalna
rozpuszczona
złoża hydrofitowe
ścieki
filtrat z odwadniania przefermentowanych osadów ściekowych
nitrogen removal
dissolved and colloidal fraction
hydrophyte beds
wastewater
reject water from mechanical dewatering of digested sewage sludge
Opis:
In constructed wetlands unit processes of pollutants removal such as sedimentation, filtration or processes involving micro-organisms of different trophic requirements occurs simultaneously. For these reasons, both the form and the degree of dispersion of pollutants may have a significant effect on the rate of removal. In the paper results of studies conducted in three multistage constructed wetland systems (MCWs) for the treatment of both domestic sewage and the filtrate generated during mechanical dewatering of digested sludge are presented. In addition to standard analyses of nitrogen fraction the determination to distinguish the forms of dissolved, colloidal and suspension of organic matter (COD) and organic nitrogen was made. Analyzed WSH provide a very stable and efficient removal of pollutants. Total nitrogen removal efficiency varied from 84.6 to 91.2% for domestic wastewater and from 73.8 to 91.4% for the filtrate. At the same time in all systems the ammonia nitrogen removal efficiency was higher than that of total nitrogen removal efficiency. The study confirmed the dependence of removal efficiency and transformation of various forms of pollution on their degree of dispersion.
Źródło:
Rocznik Ochrona Środowiska; 2015, Tom 17, cz. 2; 880-899
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ właściwości fizykochemicznych ścieków z przemysłu cukierniczego na aktywność osadu czynnego i efektywność usuwania związków azotu
The effect of physicochemical properties of sugar industry wastes on activity of activated sludge and efficiency of nitrogen compound removal
Autorzy:
Krzanowski, S.
Walega, A.
Powiązania:
https://bibliotekanauki.pl/articles/61559.pdf
Data publikacji:
2007
Wydawca:
Polska Akademia Nauk. Stowarzyszenie Infrastruktura i Ekologia Terenów Wiejskich PAN
Tematy:
scieki przemyslowe
scieki cukiernicze
wlasciwosci fizykochemiczne
wskazniki zanieczyszczen
biochemiczne zapotrzebowanie tlenu
chemiczne zapotrzebowanie tlenu
zawiesina ogolna
azot ogolny
azot amonowy
fosfor ogolny
oczyszczanie sciekow
oczyszczanie biologiczne
osady czynne
nitryfikacja
denitryfikacja
usuwanie azotu
Opis:
Celem artykułu jest rozpoznanie właściwości fizykochemicznych ścieków z przemysłu cukierniczego pod kątem ich podatności na procesy biologicznego oczyszczania, a głównie usuwania związków azotu. Przedmiotowe badania prowadzono w skali laboratoryjnej, wykorzystując ciąg technologiczny, składający się z komory beztlenowej, gdzie realizowany był proces denitryfikacji i napowietrzanego zbiornika, w którym zachodził proces nitryfikacji z wbudowanym współśrodkowo osadnikiem wtórnym. Przeprowadzone badania wykazały, że skład analizowanych ścieków cukierniczych był zmienny w czasie i uzależniony od prowadzonego w zakładzie procesu produkcyjnego. Wykazano również, że analizowane ścieki są podatne na rozkład biologiczny, gdyż zawierają znaczny udział (92% całkowitego ChZT) substancji organicznej ulegającej biodegradacji. Utrzymywanie długiego wieku osadu (średnio 17 d) spowodowało ustabilizowanie się osadu, na co wskazywała niska wartość testu OUR równa 7,77 mgO2·gsm-1·h-1. Z powodu okresowych szczytowych obciążeń osadu ładunkiem azotu amonowego proces nitryfikacji przebiegał niestabilnie (średnia szybkość nitryfikacji wynosiła 0,67 mgN-NO3·gsm-1·h-1). Średnia szybkość denitryfikacji wynosiła 0,52 mgN-NO3·gsm-1·h-1.
Biological methods have always played an important role in sludge treatment technology. Biological treatment may be conducted in various ways, in many cases as activated sludge method. Currently the processes and factors affecting efficient elimination of pollutants from municipal wastes have been relatively well identified. On the other hand the situation is different for industrial sludges. Efficiency of industrial sludge treatment plant depends mainly on physicochemical properties of sludge inflowing from individual enterprises. The work aimed at identification of sugar industry waste composition in view of its susceptibility to the processes of biological treatment, mainly removal of nitrogen compounds. The subject research was conducted in a laboratory model of bioreactor composed of an anoxic chamber where the denitrification process was conducted and aerated tank with a built-in secondary settlement tank in which nitrification process was taking place. Analyzed were sugar-mill wastes supplied from a factory and sewage treated in the analyzed model. Conditions in both chambers of the model treatment plant were monitored during the investigations. Activity of the activated sludge and the course of nitrification and denitrification processes were determined using OUR, AUR and NUR tests. The analyses have revealed that sugar wastes composition is variable in time and dependant on the production process realized in the factory. The variability may negatively affect the future treatment plant operation, particularly the course of nitrification process. It has been also demonstrated that the analyzed sewages are susceptible to biological decomposition because they contain a considerable proportion of organic substance undergoing biodegradation (92% of the total COD). A considerable content of the degradable substance in raw sewage is advantageous for the proper course of denitrification process. Problems with proper course of nitrification process, caused mainly by the composition of inflowing sewage, were observed during the experiment. Periodical presence of surface-active substances and fats in sewage caused a development of thread bacteria and accompanying activated sludge swelling. Maintaining long sludge age (on average 17days) caused the sludge stabilization as has been evidenced by low value of OUR test equaling 7.77 mgO2 · gsm-1·h-1. Due to periodical maximum loading of the sludge by ammonium nitrogen, nitrification process was unstable (mean nitrification rate was 0.67 mgN-NO3 ·gsm-1·h-1) whereas maintaining long sludge age and high oxygen concentration in the aerated tank might be the cause of low nitrification rate (0.52 mgN-NO3 ·gsm-1·h-1) and small participation of denitrifying bacteria in the system (19% of all microorganism populations). Despite these operational problems a satisfactory reduction of ammonium nitrogen (61%) and total nitrogen (64.8%) from the sewage was obtained.
Źródło:
Infrastruktura i Ekologia Terenów Wiejskich; 2007, 1
1732-5587
Pojawia się w:
Infrastruktura i Ekologia Terenów Wiejskich
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-13 z 13

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies