Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "rectifier bridge" wg kryterium: Temat


Wyświetlanie 1-3 z 3
Tytuł:
Słynni dziewiętnastowieczni wrocławscy elektrycy
Famous nineteenth-century electricians from Wrocław
Autorzy:
Przytulski, A.
Powiązania:
https://bibliotekanauki.pl/articles/1199200.pdf
Data publikacji:
2017
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
Leo Graetz
mostek prostowniczy
Karl Steinmetz
silnik histerezowy
Max Schiemann
trolejbus
Oskar Oliven
plan Olivena
rectifier bridge
hysteresis engine
trolleybus
Oliven's plan
Opis:
This paper presents figures and main achievements of electricians, who were born in Wroclaw in the nineteenth century. Each of them dealt with various fields wide spectrum of electrical engineering. Leo Graetz - the first and foremost a creator of the rectifier bridge, which is being used until today. Karl Steinmetz was the first one, who described the hysteresis loop and constructed same named engine. Max Schiemann was a German trolley-binder pioneer. Oskar Oliven was a visionary of Europe, using joint energy system, which was to be formed only dozen years after the WWI. His plans were damaged when Nazis came to power in Germany.
W artykule przedstawiono sylwetki i główne dokonania elektryków, którzy urodzili się we Wrocławiu w dziewiętnastym stuleciu. Każdy z nich zajmował się różnymi dziedzinami z zakresu szeroko pojętej elektrotechniki. Leo Graetz – to przede wszystkim konstruktor używanego do dzisiaj mostka prostowniczego, Karl Steinmetz pierwszy opisał pętlę histerezy i skonstruował silnik o tej samej nazwie, Max Schiemann – to niemiecki pionier trolejbusów, a Oskar Oliven to wizjoner wspólnej energetycznej Europy, która miała powstać kilkanaście lat po pierwszej wojnie światowej, a plany którego zniweczyło dojście do władzy w Niemczech nazistów.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2017, 4, 116; 227-236
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza wpływu indukcyjności zasilania na pracę prostownika mostkowego
Analysis of the Influence of a Power Inductance on the Operation of a Bridge Rectifier
Autorzy:
Wciślik, M.
Strząbała, P.
Powiązania:
https://bibliotekanauki.pl/articles/160185.pdf
Data publikacji:
2016
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Elektrotechniki
Tematy:
odbiornik nieliniowy
prostownik mostkowy
praca ciągła
modelowanie
nonlinear load
bridge rectifier
continuous operation
modeling
Opis:
Układ prostownika dwupołówkowego mostkowego jest jednym z najczęściej stosowanych odbiorników nieliniowych. Głównym obszarem zastosowań tego układu są jednofazowe zasilacze sieciowe, które stanowią wyposażenie większości urządzeń elektronicznych. Pobór energii tego typu urządzeń nie jest duży. Jednak znaczna ich ilość jednocześnie pracująca w systemie elektroenergetycznym sprawia, że całkowity efekt negatywnych zjawisk wprowadzanych do systemu zasilania jest znaczący. W celu zbadania zjawisk w systemie, propagacji wyższych harmonicznych oraz mocy biernej, opracowano model umożliwiający symulację obwodu z prostownikiem dwu-połówkowym mostkowym, zasilanym przez dodatkową indukcyjność. W pierwszym etapie obwód był modelowany w programie PSpice. Wyniki porównano z przebiegami w obwodzie rzeczywistym. Zaproponowano nieliniowy model prostownika mostkowego. W pracy przedstawiono stosowane modele obwodów z prostownikiem mostkowym oraz sposoby ich analizy. Opracowano model matematyczny analizowanego obwodu oraz przedstawiono metodykę formowania równań opisujących obwód z wykorzystaniem zmiennych bezwymiarowych. Na podstawie modelu matematycznego utworzono schemat operacyjny obwodu w programie Simulink. Przeprowadzono analizę pracy ciągłej prostownika oraz wykonano bilanse mocy czynnej oraz biernej.
A full-wave bridge rectifier is one of the most often used non-linear load. A main area of its using are single-phase power suppliers which are a part of the most of electronic devices. The power consumption of these devices is not large. However a large number of them that work simultaneously in the power system may cause that the total effect of voltage disturbances in the power system is significant. For the purpose of investigation of the propagations of higher harmonics and the reactive power phenomena in the system, the model of the circuit with the full-wave rectifier bridge with an additional inductance connected in-series supplied from AC voltage source was worked out. In the first step, the circuit was modeled in PSpice system. The result were compared with the waveforms of the real circuit. The non-linear model of the bridge rectifier was proposed. The models of circuit and methods of their analysis were presented. The mathematical model of the analysed circuit was worked out. Methodology of circuit equations forming with the use of dimensionless variables was shown. On the basis of the mathematical model the operational diagram in Simulink of the circuit was created. The operation analysis of the continuous work of the rectifier was carried out. The balances of active and reactive power were performed.
Źródło:
Prace Instytutu Elektrotechniki; 2016, 272; 49-62
0032-6216
Pojawia się w:
Prace Instytutu Elektrotechniki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wirtualny punkt synchronizacji w układach sterowania trójfazowymi mostkami tyrystorowymi
Virtual Synchronization Point in Control Circuit of Three-Phase SCR Bridge Rectifier
Autorzy:
Stopczyk, W
Nawrocki, Z.
Powiązania:
https://bibliotekanauki.pl/articles/1368582.pdf
Data publikacji:
2013
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
wirtualny punkt synchronizacji
układ sterowania
trójfazowe mostki tyrystorowe
virtual synchronization point
control circuit
three-phase SCR bridge rectifier
Opis:
In welding power systems with thyristor regulatory elements where stability and accuracy of the control of output parameters play a key role it becomes important to precisely detect moments of zero crossing in adequate phase voltage of power line. When we have strong mains with sinusoidal voltage waveforms, zero crossing detection of phase voltages is simple. It is different in Th case of mains phase voltage waveforms which are deformed and when switching thyristor bridge visibly deformed voltage waveforms. Such a situationwe have where the thyristor bridge is powered by generator. The article describes the digital control system of 20kW three-phase, 6-pulse thyristor bridge using virtual synchronization point. The system was tested in the welding machine with 500A of output current, powered by generator with output power of 13.2 kW. Despite a significant deformation voltage supply, system still worked correctly. The article presents the output voltage waveforms for typical control systems and a system using virtual synchronization with the deformed point power supply.
W układach zasilaczy spawalniczych, gdzie elementami regulacyjnymi są tyrystory, gdy ważna jest stałość parametrów i dokładność regulacji parametrów wyjściowych, dużego znaczenia nabiera precyzyjne wykrywanie momentów przejść przez zero odpowiednich napięć fazowych linii zasilającej. W przypadku, gdy mamy do czynienia ze sztywną siecią zasilającą i sinusoidalnymi przebiegami napięć zasilających, detekcja przejść przez zero napięć fazowych nie stwarza większych problemów. Inaczej jest w przypadku sieci zasilającej, gdzie przebiegi napięć fazowych są silnie odkształcone i gdy komutacja mostka tyrystorowego odkształca w widoczny sposób przebiegi napięcia zasilającego. Taką sytuację mamy w przypadku, gdy mostek tyrystorowy jest zasilany z agregatu prądotwórczego. W artykule opisano cyfrowy układ sterowania trójfazowego sześciopulsowego mostka tyrystorowego o mocy 20kW z zastosowaniem wirtualnego punktu synchronizacji. Opisywany układ sprawdzono w urządzeniu spawalniczym o prądzie wyjściowym 500A, zasilanym z agregatu prądotwórczego o mocy wyjściowej 13,2kW. Pomimo znacznego odkształcenia napięcia zasilającego, układ nadal pracował poprawnie. W artykule przedstawiono oscylogramy napięcia wyjściowego dla typowych układów sterowania i układu z zastosowaniem wirtualnego punktu synchronizacji przy odkształconym napięciu zasilającym.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2013, 1, 98; 199-203
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-3 z 3

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies