Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "fire resistance" wg kryterium: Temat


Tytuł:
Odporność ogniowa drewna klejonego
Glulam fire resistance
Autorzy:
Iarova, N.
Powiązania:
https://bibliotekanauki.pl/articles/134802.pdf
Data publikacji:
2016
Wydawca:
ADVSEO
Tematy:
glulam
charring
fire resistance
fire protection
Opis:
Structural glued laminated timber (glulam) is a modern building material, which is very popular in the modern construction industry because of its durability, beautiful appearance, economic and ecological parameters, and the most important, of its fire resistance, which can be designed according to the calculation methods of fire resistance for wood. One of the main aspects in the construction industry is to ensure the safety of a building. Fire safety was designed for buildings in general and for building materials which were used for the construction. One of the most important characteristics of glulam is fire resistance - its ability to meet the requirements of fire protection in fire conditions. Fire resistance is a period of time in which the structural member can save its power and integrity under influence of fire. Glued laminated timber is primarily used as supporting material and acts as a main structural element. Once a wood catches fire it typically develops char, which insulates the wood, slowly extinguishes fire and protects the core of the wood preserving properties of the structural material, which is a significant advantage compared to other construction materials.
Źródło:
Technical Issues; 2016, 1; 30-36
2392-3954
Pojawia się w:
Technical Issues
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wentylacja pożarowa tuneli przy zastosowaniu wielkogabarytowych przepustnic odcinających
Tunnel fire ventilation system equiped with large fire dumpers used in transversal systems
Autorzy:
Krajewski, G.
Węgrzyński, W.
Bera, P.
Powiązania:
https://bibliotekanauki.pl/articles/252355.pdf
Data publikacji:
2015
Wydawca:
Instytut Naukowo-Wydawniczy TTS
Tematy:
tunel
wentylacja
ognioodporność
tunnel
ventilation
fire resistance
Opis:
W artykule omówiona została metodyka badań wielkogabarytowych klap odcinających stosowanych min. w systemach wentylacji pożarowej tuneli drogowych jak i kolejowych. Polskie przepisy w zależności od długości tunelu wymagają stosowanie określonego systemu wentylacji. W tunelach powyżej 1000 m długości wymagane jest stosowanie systemu wentylacji poprzecznej. Przepustnice odcinające opisane w niniejszym artykule są nieodłącznym elementem tego typu systemów. W celu zapewnienia niezawodności działania tak istotnego urządzenia w czasię pożaru niezbędne jest przeprowadzenie szeregu badań mających na celu potwierdzeni jego niezawodności i pewności działania w czasie pożaru.
The aim of these paper are requirements for testing fire dumpers used in transversal fire ventilation system. This part of a system has to be carefully tested according to standards mention in text. Tests improved high quality of fire safety equipment.
Źródło:
TTS Technika Transportu Szynowego; 2015, 12; 2662-2665
1232-3829
2543-5728
Pojawia się w:
TTS Technika Transportu Szynowego
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Czynniki stymulujące właściwości użytkowe stali do pracy w podwyższonych temperaturach
Drivers performance for steel at elevated temperatures
Autorzy:
Nowak, P.
Powiązania:
https://bibliotekanauki.pl/articles/191147.pdf
Data publikacji:
2013
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
stal zaworowa
żaroodporność
żarowytrzymałość
valve Steel
fire resistance
heat strength
Opis:
W pracy przedstawiono wyniki badań nad szybkością wysokotemperaturowego utleniania obecnie najczęściej stosowanych stali zaworowych H9S2 i 50H21G9 N4. Badaniami objęto również stal niskostopową 42CrMo4 stosowaną na zawory dolotowe silników oraz stal austenityczną H23N18. W przeprowadzonych badaniach stwierdzono zaskakująco duży spadek żaroodporności stali chromowo-manganowej 50H21G9N4 w temperaturach przekraczających 800°C. Szybkość utleniania tej stali w temperaturze 900°C ponadsześciokrotnie przekroczyła umowną wartość 1g/(m²·h) wyznaczającą granicę żaroodporności stali. Tak duży spadek żaroodporności stali 50H21G9N4 należy wiązać ze zwiększoną kruchością zgorzeliny zawierającej tlenki manganu, co potwierdziły badania makroskopowe. W przeprowadzonych badaniach najwyższą żaroodporność wykazywała stal austenityczna chromowo-niklowa H23N18, ale możliwości zastosowania tej stali na zawory wylotowe są bardzo ograniczone ze względu na stosunkowo niskie własności wytrzymałościowe w temperaturach przekraczających 700°C. W świetle przeprowadzonych badań w pełni uzasadniona jest konieczność podjęcia prac nad opracowaniem ceramicznych powłok kompozytowych stwarzających bariery cieplne na powierzchniach zaworów narażonych na działanie gorących gazów spalinowych [L. 7, 8]. Powłoki te są przydatne również w technologii obróbki cieplnej stali żaroodpornej, np. gdy istotne jest uzyskanie określonych właściwości w aspekcie charakterystyk tribologicznych.
The paper presents the results of a study into the high temperature oxidation of H9S2 and 50H21G9N4 steels, currently the most commonly used valve steels. The study also comprised the low-alloy 42CrMo4 steel used for internal-combustion engine intake valves as well as the H23N18 austenitic steel. The study demonstrated a remarkably high decrease of the heat resistance of the chromium manganese 50H21G9N4 steel at temperatures exceeding 800°C. The oxidation rate at 900°C exceeded the arbitrary 1g/(m2·h) heat resistance limit by over six times. Such a high decrease of heat resistance of 50H21G9N4 seems related to increased fragility of the scale containing manganese oxides, which was confirmed by a macroscopic study. The austenitic chromium-nickel H23N18 steel. Revealed the highest level of heat resistance but its low mechanical properties at temperatures exceeding 700°C considerably reduces its potential use in exhaust valves. The present study necessitates future research into the development of ceramic composite coatings that would constitute thermal barriers on valve surfaces exposed to hot exhaust gases [L. 7, 8]. These coverings are useful in technology of thermal processing also steel heat-prof, e.g. when obtainment of definite specificity is important in aspect of characteristic tribology.
Źródło:
Tribologia; 2013, 6; 69-76
0208-7774
Pojawia się w:
Tribologia
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Nowe klasyfikacje w zakresie odporności ogniowej ścian nienośnych - obudowy szybów instalacyjnych z okładzinami z płyt gipsowo-kartonowych
New fire resistance classification of partitions - installation shafts lining covered by gypsum plaster-boards
Autorzy:
Wróblewski, B.
Borowy, A.
Powiązania:
https://bibliotekanauki.pl/articles/162041.pdf
Data publikacji:
2010
Wydawca:
Polski Związek Inżynierów i Techników Budownictwa
Tematy:
szyb instalacyjny
obudowa szybu
ściana działowa
płyta gipsowo-kartonowa
reakcja na ogień
odporność ogniowa
badanie ogniowe
klasyfikacja ogniowa
ściana nienośna
installation shaft
shaft lining
partition
gypsum-plaster board
reaction to fire
fire resistance
fire resistance test
fire resistance classification
non-bearing wall
Opis:
Artykuł przedstawia: informacje o produkcji płyt gipsowo-kartonowych w Polsce, właściwości płyt gipsowo-kartonowych w ogniu i stare klasyfikacje odporności ogniowej ścian działowych - obudowy szachtów instalacyjnych, nowe metody badań odporności ogniowej ścian nienośnych i klasyfikacje wg normy PN-EN 13501-2:2008, nowe zalecenia normy PN-EN 520, nowe badania odporności ogniowej i nowe klasyfikacje ogniowe ścian - obudowy szybów instalacyjnych, wnioski.
The paper presents: information about production of partitions in Poland, properties of gypsum-plaster boards in fire and old fire resistance classification of partitions, the new test methods of fire resistance for non-load bearing walls and classification standard PN-EN 13501-2:2008, the new requirements of the standard PN-EN 520, the new fire resistance tests and the new fire resistance classification of partitions, conclusions.
Źródło:
Przegląd Budowlany; 2010, R. 81, nr 6, 6; 74-76
0033-2038
Pojawia się w:
Przegląd Budowlany
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena wpływu azotowania powierzchni stali zaworowych na ich żaroodporność
Evaluation of effect of surface nitriding of valve steels on their heat resistance
Autorzy:
Jurasz, Z.
Powiązania:
https://bibliotekanauki.pl/articles/309880.pdf
Data publikacji:
2017
Wydawca:
Instytut Naukowo-Wydawniczy "SPATIUM"
Tematy:
stal zaworowa
żaroodporność
azotowanie jarzeniowe
valve Steel
fire resistance
nitriding process
Opis:
W artykule przedstawiono ocenę wpływu azotowanych powierzchni czterech gatunków stali zaworowych: X33CrNiMn23- 8, X50CrMnNiNbN21-9, X53CrMnNiN20-8 i X55CrMnNiN20-8 na ich żaroodporność. Ocenę tą umożliwiło porównanie przebiegów kinetyki wysokotemperaturowego utleniania próbek, azotowanych i bez takiej modyfikacji. Zmodyfikowaną powierzchnię próbek stanowiła cienka warstwa azotków o grubości < 0,5 μm. Warstwa ta została wytworzona w warunkach wyładowania jarzeniowego. Utlenienie przeprowadzono w warunkach izotermicznych, w temperaturze 1173 K. Kinetykę utleniania określono ciągłą metodą mikrograwimetryczną. Na podstawie uzyskanych wyników stwierdzono, że największą poprawę żaroodporności wykazała stal X50CrMnNiNbN21-9, nieznaczną poprawę żaroodporności wykazała stal X33CrNiMn23-8, natomiast dla pozostałych stali, X53CrMnNiN20-8 i X55CrMnNiN20-8, nie zaobserwowano pozytywnego wpływu przeprowadzonego azotowania na ich żaroodporność.
In this paper evaluation of effect of nitrided surface of valve steels, X33CrNiMn23-8, X50CrMnNiNbN21-9, X53CrMnNiN20-8 and X55CrMnNiN20-8 on their heat resistance was presented. This evaluation was performed by comparison of courses of kinetics of high-temperature oxidation of nitrided valve steel with samples without such modification. The nitrided layer with depth < 0,5 μm was generated in glow discharge conditions. Experiment of oxidation of investigated steels was carried out by continuous microgravimetric method in isothermal condition at 1173 K. On the basis of obtained results, it was stated the highest improvement of heat resistance properties shows X50CrMnNiNbN21-9 steel. The lower improvement of heat resistance shows X33CrNiMn23-8 steel, whereas for other investigated X53CrMnNiN20-8 and X55CrMnNiN20-8 steels a positive effect of nitriding on their heat resistance was not observed.
Źródło:
Autobusy : technika, eksploatacja, systemy transportowe; 2017, 18, 6; 775-778, CD
1509-5878
2450-7725
Pojawia się w:
Autobusy : technika, eksploatacja, systemy transportowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Pożar a wymagania. Część 3
The thermal impact of fire and requirements
Autorzy:
Kosiorek, M.
Powiązania:
https://bibliotekanauki.pl/articles/129369.pdf
Data publikacji:
2015
Wydawca:
PWB MEDIA Zdziebłowski
Tematy:
regulacje
ognioodporność
struktura
realistyczna ocena
regulations
fire resistance
structure
realistic assessment
Opis:
W artykule przeprowadzono analizę przepisów z uwagi na wymagania dotyczące odporności ogniowej konstrukcji. Wykazano, że nie ma związku między wymaganiami podanymi w przepisach a realistyczną oceną przebiegu pożaru na podstawie Eurokodów. Wskazano również i poparto przykładem obliczeniowym możliwość indywidualnej oceny efektu oddziaływań pożaru na konstrukcję.
The article comprises an analysis of regulations in respect of the requirements for the fire resistance of a structure. It has been shown that there is no link between the requirements specified in the regulations and realistic assessment of fire process based on Eurocodes. It has also been pointed out that there is a possibility of individual assessment of fire impact on structures, which has been supported by an example calculation.
Źródło:
Builder; 2015, 19, 12; 86-88
1896-0642
Pojawia się w:
Builder
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Projektowanie konstrukcji budowlanych z uwagi na warunki pożarowe jako podstawa bezpieczeństwa ludzi i mienia w czasie pożaru obiektu budowlanego
Designing of building structures for fire conditions as a basis of people and estate during fire of building
Autorzy:
Grabias, M.
Halicka, A.
Snela, M.
Szerafin, J.
Powiązania:
https://bibliotekanauki.pl/articles/390772.pdf
Data publikacji:
2016
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Tematy:
pożar
pożar obliczeniowy
klasa odporności ogniowej
bezpieczeństwo pożarowe
fire
design fire
class of fire resistance
fire safety
Opis:
W artykule przedstawiono istotę i podstawy metod projektowania konstrukcji budowlanych z uwagi na warunki pożarowe. Wskazano na wpływ temperatur pożarowych na powstanie dodatkowych oddziaływań oraz na zmiany parametrów materiałowych przekroju. Zwrócono uwagę na specyfikę zachowania się konstrukcji żelbetowych, murowych, stalowych i drewnianych w warunkach pożaru.
In the paper the ideas and basics of methods for designing of building structures under the fire conditions are presented. The influence of fire temperatures on the occurrence of additional actions on the one hand and the changes in material parameters on the other hand is mentioned. The attention is paid to specific behaviour of concrete, masonry, timber and steel structures in fire.
Źródło:
Budownictwo i Architektura; 2016, 15, 3; 21-28
1899-0665
Pojawia się w:
Budownictwo i Architektura
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Jak dostosowywać budynki drewniane do przepisów pożarowych?
How to adapt wooden buildings to fire regulations?
Autorzy:
Żmijewski, T.
Powiązania:
https://bibliotekanauki.pl/articles/390762.pdf
Data publikacji:
2015
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Tematy:
drewno
budownictwo
przepisy przeciwpożarowe
architektura wernakularna
wood
construction
architecture
vernacular
fire resistance
Opis:
W artykule zaprezentowano możliwości dostosowania budynków do przepisów przeciwpożarowych ze względu na odporność ogniową. Przedstawione możliwości są przykładowymi rozwiązaniami wpływającymi na zwiększenie wytrzymałości pożarowej drewnianych elementów obiektów. Są to elementy czynnej i biernej ochrony pożarowej, które w różny sposób ingerują w strukturę budynku.
The article presents the possibility of adapting the buildings to fire regulations due to fire resistance. The possibilities are examples of solutions that affect increase the strength of the fire wood elements objects. These are the elements of active and passive fire protection in various ways interfere with the structure of the building.
Źródło:
Budownictwo i Architektura; 2015, 14, 4; 183-188
1899-0665
Pojawia się w:
Budownictwo i Architektura
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Odporność ogniowa konstrukcji żelbetowych
Autorzy:
Kosiorek, M.
Powiązania:
https://bibliotekanauki.pl/articles/128792.pdf
Data publikacji:
2016
Wydawca:
PWB MEDIA Zdziebłowski
Tematy:
konstrukcje betonowe
ognioodporność
ochrona przeciwpożarowa
zbrojenie zewnętrzne
concrete structures
fire resistance
fire protection
external reinforcement
Opis:
Zasady określania odporności ogniowej są podane w normie EN 1992-1-2 [1]. Można wyróżnić cztery rodzaje metod: tablicową, izotermy 500°C, strefową oraz metody zaawansowane. W artykule zostanie przedstawiona ich charakterystyka.
The article described of issues related to the fire resistance of concrete structures taking into impacts in an emergency situation and external reinforcement. In many cases, it is possible not to fire-protect a external reinforcement.
Źródło:
Builder; 2016, 20, 7; 131-133
1896-0642
Pojawia się w:
Builder
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Nośność na zginanie w pożarze rozwiniętym stalowych belek ze środnikiem z blachy profilowanej
Bending resistance of steel beams with corrugated web under fully developed fire
Autorzy:
Maślak, M.
Kuchta, K.
Łukacz, M.
Powiązania:
https://bibliotekanauki.pl/articles/389874.pdf
Data publikacji:
2013
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Tematy:
nośność
stateczność
zginanie
profilowany środnik
pożar rozwinięty
odporność ogniowa
resistance
stability
bending
corrugated web
fully developed fire
fire resistance
Opis:
Zaprezentowano algorytm szacowania nośności na zginanie stalowej belki z profilowanym środnikiem uogólniony na przypadek pożaru rozwiniętego. Proponuje się aby stan graniczny nośności ogniowej determinował interakcyjny warunek dwukierunkowego zginania, w którym zginanie względem osi słabej wynika z oddziaływania tak zwanego strumienia ścinania. Wpływ ten, zwykle pomijany w tradycyjnych modelach obliczeniowych odnoszonych do podstawowej sytuacji projektowej, w przypadku pożaru może nabierać znaczenia na skutek postępującej wraz z narastaniem temperatury pasów redukcji granicy plastyczności stali, z której je wykonano. Uwzględnia się przy tym zależność od temperatury materiału odpowiednich współczynników globalnej niestateczności, w szczególności współczynnika zwichrzenia i współczynnika wyboczenia pasa ściskanego z płaszczyzny dźwigara.
More accurate design algorithm helpful in bending resistance evaluation of steel beams with corrugated web exposed to fully developed fire is presented and discussed in detail. The condition of fire resistance limit state is proposed to be determined by the interactive formula based on the consideration of biaxial bending in which the transverse out-of-plane bending phenomenon is the spatial effect of in-plane shear. Such an influence, usually neglected in formal models dealing with the persistent design situation, can become more significant under fire conditions, when the steel yield point decreases as a consequence of the flanges temperature growth. Dependence between the material temperature and the global instability factors is considered in the methodology proposed by the authors, especially with relation to the assessment of the adequate values of lateral – torsional buckling coefficient as well as of flexural transverse buckling coefficient specified for the compressed flange. The conclusive safety condition should be supplemented by the additional interactive component in which the influence of the axial compression force is expressed, in the case when such internal force is induced in a considered beam as a result of thermal strains constrainment.
Źródło:
Budownictwo i Architektura; 2013, 12, 2; 229-236
1899-0665
Pojawia się w:
Budownictwo i Architektura
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Prędkość zwęglania drewna w analizie pożarowej konstrukcji drewnianych
Charring rate of wood in the fire analysis of timber structures
Autorzy:
Dębowska, A.
Powiązania:
https://bibliotekanauki.pl/articles/131440.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Komisja Inżynierii Budowlanej PAN Oddział w Katowicach
Tematy:
drewno
konstrukcja drewniana
pożar
prędkość zwęglania
odporność ogniowa
wood
timber structure
fire
charring rate
fire resistance
Opis:
Intensive heating of elements of timber structures in the fire leads to the damage of these structures. Wood is a combustible material and the thickness of the charred layer influences on the shape and dimensions of the cross-section. The paper deals with charring rate of wood as an important parameter in fire resistance of timber structures. The change of charring rate depend on the various properties and factors (density, moisture content, time, heat flux), therefore more research should be carried out to determine a calculation models for the charring rate of wood.
Źródło:
Roczniki Inżynierii Budowlanej; 2016, 16; 95-100
1505-8425
Pojawia się w:
Roczniki Inżynierii Budowlanej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Miejsca krytyczne elementów próbnych przeszklonych ścian osłonowych pod względem izolacyjności ogniowej
Critical Places Regarding Fire Insulation of Glazed Curtain Walls Test Specimens
Autorzy:
Sędłak, B.
Kinowski, J.
Sulik, P.
Powiązania:
https://bibliotekanauki.pl/articles/372804.pdf
Data publikacji:
2017
Wydawca:
Centrum Naukowo-Badawcze Ochrony Przeciwpożarowej im. Józefa Tuliszkowskiego
Tematy:
bezpieczeństwo pożarowe
odporność ogniowa
izolacyjność ogniowa
ściana osłonowa
badania ogniowe
fire safety
fire resistance
fire insulation
curtain wall
fire tests
Opis:
Cel: Celem pracy jest przedstawienie wiedzy na temat badań oraz klasyfikacji odporności ogniowej przeszklonych ścian osłonowych, a ponadto wyznaczenie punktów krytycznych elementów próbnych ścian osłonowych pod względem izolacyjności ogniowej. Wprowadzenie: Ściana osłonowa składa się zazwyczaj z pionowych i poziomych elementów konstrukcyjnych, połączonych razem, zakotwionych do konstrukcji nośnej budynku i wypełnionych tak, by tworzyć lekkie, ciągłe pokrycie zamykające przestrzeń, które spełnia, samodzielnie lub w połączeniu z konstrukcją budynku, wszystkie normalne funkcje ściany zewnętrznej budynku, ale nie pełni funkcji nośnej. W niniejszym artykule przedstawione zostały główne aspekty dotyczące odporności ogniowej przeszklonych ścian osłonowych. Omówiono metodykę badań oraz sposób klasyfikacji odporności ogniowej elementów tego typu. Ponadto podjęto próbę zdefiniowania słabych punktów elementów próbnych przeszklonych ścian osłonowych na podstawie badań przeprowadzonych w ostatnich latach w Zakładzie Badań Ogniowych Instytutu Techniki Budowlanej (ZBOITB). Przeanalizowano przyrosty temperatur na nienagrzewanej powierzchni 17 elementów próbnych przeszklonych ścian osłonowych badanych w warunkach oddziaływania ognia od wewnątrz zgodnie z normami PN-EN 1364-3:2007 oraz PN-EN 1364-3:2014. Wszystkie z analizowanych elementów próbnych osiągnęły klasę odporności ogniowej min. EI 15. Metodologia: W pracy przedstawiono wyniki analizy przyrostów temperatury na nienagrzewanej powierzchni elementów próbnych przeszklonych ścian osłonowych dokonanej podczas badań odporności ogniowej. Badania przeprowadzono zgodnie z normami PN-EN 1364-3:2006 oraz PN-EN 1364-3:2014 w ZBOITB w Warszawie oraz w Pionkach. Wnioski: Największy przyrost temperatury najczęściej rejestrowano w miejscu połączenia słupów oraz rygli. Miejsce to można uznać za najbardziej krytyczne. Duży przyrost temperatury w tych miejscach spowodowany jest najprawdopodobniej dużymi ugięciami elementów próbnych przeszklonych ścian osłonowych w trakcie badania. Deformacja ta powoduje wypinanie się rygli ze słupów fasady, w wyniku czego tworzą się miejsca, przez które przedostają się gorące gazy. Ponadto w miejscach tych dosyć często występują specjalne łączniki, które ograniczają zaizolowaną przestrzeń profilu. Dodatkowo zaobserwowanym ciekawym zjawiskiem jest pojawienie się stosunkowo wysokich temperatur na przeszkleniu w odległości 20 mm od słupa lub rygla. Wymagania dotyczące pomiaru temperatury w tych miejscach zostały określone dopiero w nowelizacji normy badawczej z 2014 roku i należy przyznać, że było to właściwe posunięcie, ponieważ miejsca te, pod względem izolacyjności ogniowej, mogą być również słabymi punktami elementów próbnych przeszklonych ścian osłonowych.
Aim: The presentation of technical know-how associated with fire tests and the classification of glazed curtain walls. The determination of critical places for maximum temperature rise on the unexposed surfaces of curtain wall test specimens. Introduction: A curtain wall is a type of wall which usually consists of vertical and horizontal structural members connected to each other and fixed to the floor-supporting structure of the building to form a lightweight space-enclosing continuous skin, which provides, by itself or in conjunction with the building construction, all the normal functions of an external wall, but doesn’t acquire any of the load-bearing properties of the building. The paper discusses the main issues related to the fire resistance of glazed curtain walls, including the testing methodology and the method of classification of this type of building element. Moreover, the paper presents an attempt to determine the weaknesses of aluminum glazed curtain wall test specimens regarding the maximum temperature-rise measurements, based on the fire-resistance tests performed in recent years by the Fire Research Department of the Building Research Institute (ITB). The paper analyses the results of the temperature rises on unexposed surfaces of 17 aluminum glazed curtain wall specimens tested for internal fire exposure in accordance with EN 1364-3:2006 and EN 1364-3:2014, which achieved the fire-resistance class of min. EI 15. Methodology: The paper presents the results of the analysis of temperature rises on the unexposed surfaces of curtain wall test specimens during fire-resistance tests. The tests were conducted in accordance with the PN-EN 1364-3:2006 and EN 1364-3:2014 standards in the Fire Testing Laboratory of the Building Research Institute (ITB) in Warsaw and Pionki. Conclusions: The highest temperature rise was recorded on the mullion and transom connections, and these places can be regarded as critical. The significant increase in temperature in those junctions can be explained by the large deformations of the glazed curtain wall specimens during the fire test. Such deformation causes the destruction of beam-to-column connections, which facilitates the flow of hot gases. Additionally, special connectors often occur in these places, which constricts the space of insulation inserts. An interesting phenomenon is the fairly high temperature rise on the glass panes, 20 mm from the mullions or transoms. Requirements regarding temperature measurements in these places were established no earlier than in the new version of the standard issued in 2014 and, as can be observed, this was the correct decision, because these places, in terms of fire resistance, can also be the weakness of glazed curtain wall specimens.
Źródło:
Bezpieczeństwo i Technika Pożarnicza; 2017, 45, 1; 38-50
1895-8443
Pojawia się w:
Bezpieczeństwo i Technika Pożarnicza
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Odporność ogniowa słupów stalowych i żelbetowych nagrzewanych z mniej niż czterech stron
Fire Resistance of Steel and Reinforced Concrete Columns Exposed to Fire on Less Than Four Sides
Autorzy:
Szymkuć, W.
Glema, A.
Malendowski, M.
Powiązania:
https://bibliotekanauki.pl/articles/373171.pdf
Data publikacji:
2016
Wydawca:
Centrum Naukowo-Badawcze Ochrony Przeciwpożarowej im. Józefa Tuliszkowskiego
Tematy:
odporność ogniowa
słup poddany działaniu ognia
ściana oddzielenia przeciwpożarowego
pożar
temperatura
fire resistance
column exposed to fire
fire wall
fire
temperature
Opis:
Wprowadzenie: W artykule przedstawiono problemy związane z odpornością ogniową słupów stalowych i żelbetowych nagrzewanych z mniej niż czterech stron, z uwzględnieniem elementów wbudowanych w ściany oddzielenia przeciwpożarowego. Jednostronne nagrzewanie słupa sprawia, że na jego przeciwległych stronach występują różne temperatury. Prowadzi to do powstawania przemieszczeń poziomych, które wywołują dodatkowe siły wewnętrzne w samym słupie, jego zamocowaniu oraz w przylegającej konstrukcji. Metody: W odniesieniu do słupów stalowych wskazano, że w normie PN-EN 1993-1-2 brakuje metod uproszczonych pozwalających na obliczenie nośności słupów stalowych poddanych oddziaływaniu wysokiej temperatury tylko z jednej strony. Opisano najważniejsze wnioski z prac badawczych przeprowadzanych w tym obszarze w ostatnich latach i wskazano możliwą do zastosowania metodę obliczania nośności tego typu elementów, uwzględniającą nierównomierny przebieg temperatury w elemencie. Tego typu nagrzewanie i związana z nim nierównomierna temperatura w obrębie przekroju sprawiają, że stal, w zależności od jej położenia w przekroju, wykazuje różne wartości parametrów takich jak granica plastyczności i moduł sprężystości. Uwzględnienie w obliczeniach rzeczywistej temperatury stalowego słupa pozwala na oszacowanie jego przemieszczeń, wywołanych wpływem nierównomiernej temperatury, od których zależą wielkości sił wewnętrznych i jego nośność. W odniesieniu do słupów żelbetowych opisano podstawowy podział metod obliczania nośności zawartych w PN-EN 1992-1-2, ze szczególnym zwróceniem uwagi na ich ograniczony zakres stosowania z uwagi na: typ konstrukcji, długość elementu, smukłość oraz wielkość mimośrodu obciążenia. Dokonano przeglądu metod pod kątem stosowania ich przy narażeniu na działanie ognia z mniej niż czterech stron. Przybliżono metodę zawartą w niemieckim załączniku krajowym do DIN-EN 1992-1-2, która pozwala na obliczenie nośności słupów wspornikowych poddanych działaniu ognia z jednej, trzech lub czterech stron. Przywołano pozycje literaturowe podające uproszczone metody obliczeń wraz z wnioskami. Dyskusja i Podsumowanie: Spośród potencjalnych rozwiązań omawianego problemu można wyróżnić: umieszczenie słupów poza ścianą oddzielenia pożarowego, zaprojektowanie połączenia pozwalającego na zawalenie się konstrukcji dachu do wnętrza hali, bez wywoływania nadmiernych sił poziomych oddziałujących na głowicę słupa lub wykorzystanie usztywnienia przylegającej konstrukcji do przeniesienia sił poziomych. Z uwagi na poziom skomplikowania bardziej zaawansowanych metod obliczania nośności, wskazane jest opracowanie metod uwzględniających nierównomierne nagrzewanie w sposób uproszczony, na bazie faktycznych przypadków pożarów budynków.
Introduction: The paper describes problems associated with fire resistance of steel and reinforced concrete columns exposed to fire on less than four sides (such as embedded in firewalls). One-sided exposure is associated with varying temperatures on both sides of the column, which leads to the formation of lateral displacement, causing additional forces in the column, its fixing and in the adjacent structure. Methods: Steel columns: It is emphasised that in PN-EN 1993-1-2 there are no simplified methods which allow to calculate the load-bearing capacity of columns exposed to fire on one side. The article describes the most important conclusions of research work carried out in recent years with an indication of a potential method for calculating load-bearing capacity of such elements, which allows to take into consideration the uneven temperature in a given element. This type of heating and uneven temperature within the cross-section resulting from it, is associated with the variation of material parameters such as yield strength and elasticity modulus depending on location in the cross-section. Reinforced concrete columns: Basic division of methods provided by PN-EN 1992-1-2 is described with special emphasis on scope of its application limited by: the type of construction, the length of the element, its slenderness and the load eccentricity. A review of methods was performed in terms of their application when exposed to fire on less than four sides. A method in the German National Annex to DIN EN 1992-1-2 is described in detail; it allows to calculate the capacity of the load-bearing capacity of cantilever columns exposed to fire from one, three or four sides. Simplified additional methods from literature are briefly described along with their conclusions. Discussion and Conclusions: The following can be distinguished among potential solutions to the problem: placing the columns outside the firewall, designing a special connection which allows the roof structure to collapse into the warehouse without causing excessive horizontal forces acting on the column or using bracing of the adjacent structure to transfer horizontal forces. However, due to the complexity of more sophisticated methods, it would be advisable to develop methods taking into account uneven exposure in a simplified manner, based on actual cases of fires in buildings.
Źródło:
Bezpieczeństwo i Technika Pożarnicza; 2016, 43, 3; 95-104
1895-8443
Pojawia się w:
Bezpieczeństwo i Technika Pożarnicza
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Odporność ogniowa sworzniowych połączeń drewnianych z wewnętrzną płytą stalową
Fire resistance of dowel connections with an internal steel plate
Autorzy:
Domański, T.
Kmiecik, K.
Powiązania:
https://bibliotekanauki.pl/articles/160854.pdf
Data publikacji:
2018
Wydawca:
Polski Związek Inżynierów i Techników Budownictwa
Tematy:
połączenie sworzniowe
płytka stalowa wewnętrzna
warunki pożarowe
odporność ogniowa
dowel connection
internal steel plate
fire conditions
fire resistance
Opis:
W artykule przedstawiono analizę odporności ogniowej sworzniowych połączeń drewnianych z wewnętrzną płytą stalową. W pierwszym etapie wykonano trójwymiarowy model numeryczny, wykorzystujący metodę elementów skończonych do analizy przewodzenia ciepła, w złączach drewnianych eksponowanych na działanie pożaru standardowego zgodnego z ISO.
This article presents an investigation on the fire performance of unprotected steel-to-timber dowel connections with slotted-in steel plate. At first, a three dimensional model was made that uses the finite element method to analyze heat transfer within timber connections exposed to the standard ISO fire.
Źródło:
Przegląd Budowlany; 2018, 89, 9; 51-55
0033-2038
Pojawia się w:
Przegląd Budowlany
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Diagnostyka przeciwpożarowa budynków
Autorzy:
Sulik, P.
Powiązania:
https://bibliotekanauki.pl/articles/128668.pdf
Data publikacji:
2017
Wydawca:
PWB MEDIA Zdziebłowski
Tematy:
diagnostyka przeciwpożarowa
budynek
bezpieczeństwo pożarowe
odporność ogniowa
reakcja na ogień
rozprzestrzenianie ognia
fire diagnostic
building
fire safety
fire resistance
reaction to fire
fire spreading
Opis:
W referacie przedstawiono podstawowe informacje pozwalające na ocenę wybranych elementów konstrukcyjnych i ogólnobudowlanych w zakresie bezpieczeństwa pożarowego budynku. Szczególną uwagę poświęcono materiałom konstrukcyjnym, tj. stali, betonowi, elementom murowym i zespolonym, powszechnie stosowanym we współczesnym budownictwie.
Źródło:
Builder; 2017, 21, 2; 65-66, 68-69
1896-0642
Pojawia się w:
Builder
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies