Tytuł:
Zmiany strukturalne w plastizolach z poli(chlorku winylu) po ich żelowaniu
Structural changes during the gelation of poly(vinyl chloride) plastisols
Autorzy:
Makarewicz, E.
Shyychuk, I.
Mroczyńska, K.
Powiązania:
https://bibliotekanauki.pl/articles/947281.pdf
Data publikacji:
2016
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Chemii Przemysłowej
Tematy:
poli(chlorek winylu)
plastizole
destrukcja termiczna
poly(vinyl chloride)
plastisols
thermal decomposition
Opis:
Wytworzono plastizole z czterech rodzajów emulsyjnego poli(chlorku winylu) (PVC): PVC E-68, Pevikon P-682, Slovinyl EP-702, Vestolit B-7021 Ultra i plastyfikatorów: ftalanu di-2-etyloheksylowego (DOP), estru diizononylowego kwasu 1,2-cykloheksanodikarboksylowego (Hexamoll DINCH), dibenzoesanu glikolu dipropylowego (S-9100) i adypinianu dioktylowego (DOA), które następnie żelowano w temp. 140 °C lub 160 °C. Za pomocą mikroskopu konfokalnego określano morfologię i wymiary ziaren proszkowych polimerów. Rejestrowano widma w podczerwieni zżelowanych plastizoli. Metodami analizy termograwimetrycznej badano też ich odporność termiczną w atmosferze powietrza. Określono wpływ procesów destrukcji przebiegających podczas żelowania plastizoli PVC na wartości temperatury: początku rozkładu, maksymalnej szybkości rozkładu i końca rozkładu poli(chlorku winylu). Stwierdzono, że zmiany zachodzące w błonach otrzymanych w wyniku zżelowania plastizoli zależą w istotnym stopniu od rodzaju poli(chlorku winylu), w mniejszym zaś od rodzaju plastyfikatora.
The study on thermal stability of polyvinyl chloride (PVC) plastisols gelled at temperatures 140 and 160 °C was carried out. Four different PVCs were used: PVC E-68 (Poland), Pevikon P-682 (Sweden), Slovinyl EP-702 (Slovakia) and Vestolit B-7021 Ultra (Germany). Four plasticizers were applied: di-2-ethylhexyl phthalate (DOP), 1,2-cyclohexanedicarboxylic acid diisononyl ester (Hexamoll DINCH), dipropylene glycol dibenzoate (S-9100) and dioctyl adipate (DOA). The morphology and size distribution of polymer particles were studied with confocal microscopy. ATR-FTIR spectra of the gelled plastisols were recorded, indicating the formation of multiple bonds, ester and ether bond as well as oxygen-containing groups. Thermal stability of the plastisols was evaluated by means of thermogravimetry in air atmosphere. The effects of degradation processes occurring during the gelation of plastisols on the temperatures of initial and final decomposition as well as maximum rate of PVC decomposition were assessed. It was found that the changes in the gelled plastisol membranes depend essentially on the poly(vinyl chloride) type and to alesser extent on the plasticizer used.
Źródło:
Polimery; 2016, 61, 7-8; 528-537
0032-2725
Pojawia się w:
Polimery
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Destrukcja mas z żywicą furanową wywoływana promieniowaniem cieplnym ciekłego metalu
Destruction of Moulding Sands with Furan Resin Caused by Heat Radiation of Liquid Metal
Autorzy:
Zych, J.
Powiązania:
https://bibliotekanauki.pl/articles/381874.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
formy piaskowe
żywica furanowa
nagrzewanie form
destrukcja termiczna
utrata wytrzymałości
sand moulds
furan resin
heating form
thermal destruction
loss of strength
Opis:
W pracy przedstawiono wyniki badań procesu nagrzewania elementów form piaskowych wykonanych z masy z żywicą furanową wywoływane promieniowanie cieplnym ciekłego żeliwa. Próbki masy umieszczano w bliskiej odległości (10-15 mm) od powierzchni górnej żeliwa znajdującego się w tyglu. Zastosowano autorską metodę badań. Wyznaczono przebiegi nagrzewania powierzchniowej warstwy próbek w funkcji czasu nagrzewania. Badaniami objęto powierzchnie próbek bez powłok i z powłokami ochronnymi. Wyznaczono wpływ czasu oddziaływania promieniowania na wytrzymałość na zginanie próbek po ich wystudzeniu do temperatury otoczenia. Stwierdzono, iż przy temperaturze żeliwa 1400 oC i przybliżeniu powierzchni próbki na odległość 10÷15 mm już po około 15 sekundach wytrzymałość masy zmniejsza się o blisko 70%. Nanoszenie powłok ochronnych zwiększa wytrzymałość powierzchniowej warstwy niekiedy kilkakrotnie. Nie pozwala jednak zachować wytrzymałości masy po poddaniu jej działaniu promieniowania cieplnego ciekłego żeliwa.
The work presents the results of tests of the heating process of sand-mould elements made of sands wit furan resin caused by heat radiation of liquid cast iron. Samples of the moulding sands were placed in near proximity (10-15 mm) of the top surface of cast iron located in a crucible. An original research method of the author was used. Trajectories of heating of the surface layer of samples in the time function were determined. The testing covered surfaces of layers both with and without coatings. The impact of the time of influence of the radiation on the samples' bending strength after cooldown to environment temperature was determined. It was found that for cast iron of the temperature 1400 oC and with samples moved closer to 10÷15 mm bending strength of the mass decreases by almost 70% after as little as 15 seconds. Laying down protective coatings increases resistance of the surface layer, sometimes even multiplying it. However it does not enable saving the mass' resistance after it is subjected to heat radiation of liquid cast iron.
Źródło:
Archives of Foundry Engineering; 2014, 14, 4 spec.; 143-148
1897-3310
2299-2944
Pojawia się w:
Archives of Foundry Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Adaptacja metody bieżącej kontroli samozagrzewania węgla do warunków eksploatacji złóż donieckich
The adaptation of the method of current coal self-heating control in Donieck deposits
Autorzy:
Kostenko, Viktor K.
Gamij, Jurij
Powiązania:
https://bibliotekanauki.pl/articles/165716.pdf
Data publikacji:
2019
Wydawca:
Stowarzyszenie Inżynierów i Techników Górnictwa
Tematy:
samozagrzewanie węgla
gazy wskaźnikowe
mechaniczna i termiczna destrukcja
próby gazowe
coal self-heating
indicator gases
mechanical and thermal destruction
gas tests
Opis:
Z powodu wojny wydobycie węgla na Ukrainie drastycznie spadło. Występowanie z kolei awarii podziemnych znacznie komplikuje prowadzenie robót górniczych, powodując utratę pokładów węgla przygotowanych do eksploatacji, wzrost kosztów wydobycia, i w końcu, zmniejszenie bezpieczeństwa energetycznego Ukrainy. Kopalnie nie są wyposażone w środki zapobiegania i wczesnego wykrywania pożarów powodowanych samozapaleniem węgla. W artykule proponuje się ulepszyć metodę bieżącej kontroli samozagrzewania węgla, wykorzystującej monitoring gazów wskaźnikowych. Badania laboratoryjne i kopalniane potwierdziły, że wydzielanie gazów wskaźnikowych podczas mechanicznej destrukcji pokładów węgla może mieć istotny wpływ na wyniki bieżącego monitorowania procesu samozagrzewania węgla. Przedstawiono adaptację metody bieżącej kontroli samozagrzewania węgla do rzeczywistych warunków górniczo-geologicznych i górniczo-technicznych jego wybierania w polach eksploatacyjnych polegającą na uwzględnieniu efektów mechanicznej destrukcji pokładów i stosowaniu elastycznego schematu pobierania prób gazowych.
Due to the war, coal mining in Ukraine dropped drastically. Occurrence of underground accidents considerably complicates the mining works, causing the loss of coal seams prepared for exploitation, causing the increase of mining costs, and finally, reducing the energy security of Ukraine. Mines are not equipped with means of preventing and early detection of fires caused by spontaneous combustion of coal. The article proposes to improve the method of current coal self-heating control using indicator gas monitoring. Laboratory and mine tests confirmed that the emission of indicator gases during the mechanical destruction of coal seams can have a significant impact on the results of the current monitoring of the coal self-heating process. In the article it is presented the adaptation of the current method of self - heating control of coal to the actual mining - geological and mining - technical conditions of its selection in exploitation fields consisting in taking into account the effects of mechanical destruction of seams and the application of a flexible gas sampling scheme.
Źródło:
Przegląd Górniczy; 2019, 75, 9; 14-20
0033-216X
Pojawia się w:
Przegląd Górniczy
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-3 z 3

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies