Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "cooling efficiency" wg kryterium: Temat


Wyświetlanie 1-6 z 6
Tytuł:
Obliczenia efektywności chłodzenia silnika elektrycznego
Calculation of cooling efficiency of the electric motor
Autorzy:
Będkowski, B.
Madej, J.
Powiązania:
https://bibliotekanauki.pl/articles/1201904.pdf
Data publikacji:
2016
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
MES
CFD
obliczenia cieplne
chłodzenie powietrzne
wydajność wentylatora
FEM
thermal calculations
air cooling
fan efficiency
Opis:
The preparation of a calibrated numerical model of the electric motor and the effectiveness of the air cooling system are presented in the article. The bench, consisting of a complete motor case and the stator, and the shaft with a fan mounted on its end was used to the model calibration. The volume flow rate of the fan with air velocity at selected points around the motor case, and the temperature at the selected measuring points in the device thermal steady state were measured. The calorimetric method and thermoanemometr were used to measure volume flow rate of the fan. The performance of the air cooling system for different values of losses (150W, 350W, 550W) at a constant fan speed (900 rpm) and for constant power (550W) at different fan speeds (300 rpm, 600 rpm, 900 rpm) was carried out. The discrete models for fan volume flow rate and the heat-flow calculations were prepared separately to determine the temperature of selected points of the cooling system. The set of characteristics showing the effects of rotational speed of the fan to the temperature of selected elements of the system was prepared on the basis of the tests and calculations.
Praca dotyczy opisu budowy skalibrowanego modelu obliczeniowego silnika elektrycznego i prezentuje efektywność chłodzenia urządzenia przy zastosowaniu powietrznego układu chłodzenia. Badania kalibracyjne zostały przeprowadzone na stanowisku, składającym się z kompletnego kadłuba wraz ze stojanem i wałem z wentylatorem osadzonym na jego końcu. W wyniku przeprowadzonych badań zmierzono wydatek wentylatora zamontowanego w układzie chłodzącym oraz prędkość powietrza w wybranych punktach wokół kadłuba, a następnie przeprowadzono próby nagrzewania i rejestracji temperatury w wybranych punktach pomiarowych. Pomiar wydatku wentylatora przeprowadzono metodą kalorymetryczną oraz przy pomocy termoanemometru. Pomiary wydajności powietrznego układu chłodzenia przeprowadzono dla różnych wartości strat (150W, 350W, 550W) przy stałej prędkości obrotowej wentylatora (900 obr/min) oraz dla stałej mocy (550W) przy różnych prędkościach wentylatora (300 obr/min, 600 obr/min, 900 obr/min). Obliczenia przeprowadzono budując osobno modele dyskretne do wyznaczenia wydatku wentylatora i do obliczeń cieplno-przepływowychw celu określenia temperatury w wybranych punktach układu. Przeprowadzone badania i obliczenia pozwoliły opracować zestaw charakterystyk przedstawiających wpływ prędkości obrotowej wentylatora na temperaturę wybranych elementów układu.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2016, 2, 110; 15-20
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Charakterystyka pomiarowa kotła na biomasę chłodzonego olejem w instalacji ORC
Experimental investigation of the biomass boiler cooled with thermal oil in ORC installation
Autorzy:
Kamiński, T.
Kardaś, D.
Powiązania:
https://bibliotekanauki.pl/articles/172926.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
kocioł na biomasę
chłodzenie olejem
instalacja ORC
sprawność cieplna
biomass boiler
cooling with thermal oil
ORC installation
thermal efficiency
Opis:
W pracy przedstawiono wyniki badań eksperymentalnych stanowiska kotłowego należącego do laboratorium mikrosiłowni Instytutu Maszyn Przepływowych. Celem pracy było wyznaczenie bilansów energii kotła opalanego biomasą, którego zadaniem jest dostarczanie ciepła dla eksperymentalnej instalacji do produkcji ciepła i prądu w mikroskali. Specyfika mikrosiłowni polega na zastosowaniu turbiny parowej w tej skali urządzeń do produkcji prądu, co powoduje nietypowe wymaganie dotyczące kotła. Ze względu na te wymogi zastosowano olej termalny jako medium odbierające ciepło od spalin. W pracy przedstawiono charakterystyki cieplne kotła sporządzone na podstawie serii pomiarów. Badania kotła prowadzono dla rożnych wydatków paliwa, ilości powietrza oraz strumieni masy czynnika chłodzącego. Na podstawie pomiarów sporządzono wykresy parametrów chemicznych i cieplnych dla rożnych nastaw kotła.
The aim of the article was to present the testing results and the analysis of performance characteristics of a small-scale biomass-fired boiler, cooled with thermal oil. This boiler is a part of the laboratory installation for combined production of heat and electric power in micro-scale (micro CHP) in the Szewalski Institute of Fluid-Flow Machinery in Gdańsk. Both, the oil-cooled boiler and the micro CHP system, are the untypical solution in the field of electric power production. The measurements were performed for different air, oil and fuel mass flow rates.
Źródło:
Archiwum Energetyki; 2012, 42, 2; 49-57
0066-684X
Pojawia się w:
Archiwum Energetyki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Automatyczne stanowisko pomiarowe do badań charakterystyk pracy plazmotronów łukowych
Automated measurement system for investigation of arc plasmatron characteristics
Autorzy:
Szałatkiewicz, J.
Kłoda, R.
Szewczyk, R.
Powiązania:
https://bibliotekanauki.pl/articles/276625.pdf
Data publikacji:
2012
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Automatyki i Pomiarów
Tematy:
bilans energetyczny
pomiary
badania sprawności
cechowanie
plazmotron
automatyka
energia
plazma
chłodzenie
energy balance
measurements
efficiency measurement
calibration
plasmatron
automation
energy
plasma
cooling
Opis:
W artykule przedstawiono rozwiązanie stanowiska pomiarowego, umożliwiającego badanie najważniejszych parametrów pracy plazmotronów. Opracowanie stanowiska badawczego jest niezbędne w celu pozyskiwania powtarzalnych danych z pomiarów parametrów pracy plazmotronów, optymalizacji ich konstrukcji, określenia bilansu energetycznego oraz ich cechowania, certyfikacji. Plazmotrony zasilane są energią elektryczną i gazem roboczym, a do ich chłodzenia stosuje się wodę. Parametry robocze plazmotronu zależą od wielu zmiennych związanych z ich geometrią, mocą, przepływem gazu roboczego i chłodzeniem. Stąd, aby określić wpływ poszczególnych zmiennych i ich wzajemne relacje, niezbędnym jest wykonanie wielu równoległych pomiarów. Pomiary poszczególnych wielkości fizycznych realizowane są przy użyciu specjalistycznych, zespolonych przyrządów pomiarowych, umieszczonych w szafie pomiarowej. Pozwala to na integrację wszystkich pomiarów i ich digitalizację w jednym miejscu. Aby wykonać pomiary w trakcie pracy plazmotronu, szafę wyposażono w złącza umożliwiające wpięcie jej układów pomiarowych w obwody mierzonego urządzenia. Dobrano metody pomiarów: napięcia (V), prądu pracy (A), mocy pobieranej z sieci (W), przepływu gazu roboczego dm3/min, przepływu i temperatury wody chłodzącej niezależnie dla anody i katody (dm3/s). Mierzone parametry pracy plazmotronu są jednocześnie zapisywane co 1 s i wizualizowane w programie w środowisku LabView, na ekranie komputera PC. System pomiarowy, na podstawie wielkości mierzonych, automatycznie wylicza bilans energetyczny, sprawność cieplną plazmotronu oraz inne istotne parametry eksploatacyjne urządzenia.
The paper, presents automated measurement system for investigation of key arc plasmatrons parameters. Automated measurement system allows to simultaneously and broadly investigate plasmatron work parameters. Collection of plasmatron operational data is required for optimization of theirs construction, efficiency determination, energy balance calculation, and calibration. Plasmatrons are powered with electrical energy and work gas, theirs cooling is carried out by water circuit. Work parameters of plasmatrons are depending on many factors, theirs geometry, power, gas flow and cooling. So to investigate influence of each factor, it is necessary to perform many simultaneous measurements. Each measurement of physical value is performed by specialist combined sensor, located in measurement cabinet. Such approach allows for integration of all the measurements and digitalization of collected data in one place. Measuremetns have to be performed during normal operation of plasmotron, to allow such action, the measurement cabinet is equipped with connections allowing to hook it up to the plasmatron circuits. Developed automated measurement system carries out key measurements of plasmatron parameters: voltage, amperage, power, flow of plasma gas, flow and temperature of cooling fluid for anode, and cathode. Measured values, are simultaneously stored each second, and visualized in application software developed in LabView, on PC. Based on collected data the software of automated measurement system calculates energy balance, efficiency, and other important parameters of plasmatorn during its exploitation.
Źródło:
Pomiary Automatyka Robotyka; 2012, 16, 2; 546-551
1427-9126
Pojawia się w:
Pomiary Automatyka Robotyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The new devices of gas-turbine engines of ground transport on the basis cascade pressure exchanger of krajniuk
Autorzy:
Krajniuk, A.
Powiązania:
https://bibliotekanauki.pl/articles/374815.pdf
Data publikacji:
2011
Wydawca:
Politechnika Śląska. Wydawnictwo Politechniki Śląskiej
Tematy:
kaskadowa wymiana ciśnienia
gazo-turbinowe silniki
cykl pracy
energooszczędność
wydajność
cascade pressure exchange
gas turbine engines
working cycle
power efficiency
performance
self-cooling
Opis:
Main trends of perfection of gas-turbine engines (GTE) of transport plants by application of principles of the cascade pressure exchange (CPE) for air compression in the working cycle of gas-turbine plant have been analyzed. The principle of action and performances of work of heat compressor CPE realizing compression of working body on the whole at the expense straight convert inputting heat in disposing work of torrent with insignificant distraction mechanics work from shaft selection of power has been described. The results of computational investigation of four variants of the GTE working process organization on the basis of the two-staged compression assembly with intermediate cooling and heating of air-gas medium have been adduced. Application of units CPE in the capacity of compressing stage GTE opens the prospect of adaptations GTE performance by conditions of work in the capacity of forcing units of overland transport.
Źródło:
Transport Problems; 2011, 6, 2; 107-119
1896-0596
2300-861X
Pojawia się w:
Transport Problems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modernizacja projektu budynku mieszkalnego do standardu NF15 z analizą kosztorysową ścian zewnętrznych
The modernization project of a residential building to the standard NF15 with an analysis of cost-estimate of external walls
Autorzy:
Ksit, B.
Sarnowska, R.
Powiązania:
https://bibliotekanauki.pl/articles/160966.pdf
Data publikacji:
2017
Wydawca:
Polski Związek Inżynierów i Techników Budownictwa
Tematy:
budynek mieszkalny
projekt
modernizacja
standard efektywności energetycznej
NF15
wymagania
ogrzewanie pasywne
chłodzenie pasywne
ściana zewnętrzna
analiza kosztów
residential building
design
modernization
energy efficiency standard
requirements
passive heating
passive cooling
external wall
cost analysis
Opis:
Celem pracy było przedstawienie analizy budynku mieszkalnego, przyjmując dwa różne rozwiązania materiałowe przy założeniu standardu NF15. Dla budynku A zastosowano ściany z bloczków keramzytobetonowych HOTBLOK i stropodach balastowy. Do wykonania izolacji przegród wykorzystano keramzyt i płyty XPS. W budynku B ściany wykonano z bloczków Ytong Energo+, zaprojektowano dach zielony, a izolacje przegród wykonano z płyt z pianki poliuretanowej. Dla wszystkich przegród dobrano grubości materiałów tak, aby wykonane obliczenia cieplnowilgotnościowe spełniały wymagania standardu NF15. Dodatkowo wykonano kosztorys ścian zewnętrznych z analizą porównawczą wybranych systemów.
The aim of the study was to analyze the residential building, taking two different material solutions assuming standard NF15. For building A wall of blocks used HOTBLOK and flat roof ballast. For insulation baffles used expanded clay and XPS boards. In building B wall made of concrete blocks YtongEnergo+, designed a green roof, and insulation partitions made of slabs of polyurethane foam. For all partitions chosen material thickness so that the calculations performed hygrothermal meet the requirements of the standard NF15. Additionally, a cost estimate of external walls of the comparative analysis of selected systems.
Źródło:
Przegląd Budowlany; 2017, 88, 7-8; 61-66
0033-2038
Pojawia się w:
Przegląd Budowlany
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Pompy ciepła dla ogrzewania i chłodzenia w aspekcie obniżenia emisji ditlenku węgla
Heat pumps for heating and cooling in terms of reducing carbon dioxine emissions
Autorzy:
Szczechowiak, Edward
Powiązania:
https://bibliotekanauki.pl/articles/2160676.pdf
Data publikacji:
2022
Wydawca:
Polski Związek Inżynierów i Techników Budownictwa
Tematy:
pompa ciepła
ogrzewanie
chłodzenie
efektywność
współczynnik SCOP
SCOP
źródło ciepła dolne
źródło ciepła górne
energia odnawialna
emisja dwutlenku węgla
heat pump
heating
cooling
efficiency
seasonal coefficient of performance
lower heat source
upper heat source
renowable energy
carbon dioxide emission
Opis:
Dyrektywy Unii Europejskiej oraz przepisy krajowe wyraźnie wskazują na rozwój budownictwa niemal zeroenergetycznego i o niskiej emisji ditlenku węgla. Artykuł zawiera informacje o tym, jak można zrealizować ten cel poprzez zastosowanie pomp ciepła i to zarówno dla potrzeb ogrzewania, jak i chłodzenia. Omówiono pompy ciepła stosowane w budownictwie, wykorzystujące energię niskopotencjalną: powietrze zewnętrzne, grunt, wodę, ścieki i inne ciepło odpadowe do konwersji na ciepło o potencjale użytkowym: do ogrzewania, podgrzewania ciepłej wody, ale również do chłodzenia pomieszczeń. Podano przykłady rozwiązań dla różnej wielkości budynków i pokazano korzyści wynikające z zastosowania pomp ciepła w aspekcie energetyczno-ekologicznym. Pompy ciepła bardzo dobrze wpisują się w tendencje przyszłościowe i pozwalają na znaczne obniżenie śladu węglowego budynków.
European Union directives and national regulations clearly indicate the development of nearly zero-energy and low-carbon construction. The article provides information on how to achieve this goal by using heat pumps for both heating and cooling. Discussed heat pumps used I construction, using low-potential energy: outdoor air, soil, water, sewage and other waste heat for conversion into heat with a useful potential for heating, hot water, but also for cooling rooms. Examples of solutions for different sizes of buildings are given and the benefits of using heat pumps in terms of energy and ecology are shown. Heat pumps fit very well into the trends of the future and allow for a significant reduction in the carbon footprint of buildings.
Źródło:
Przegląd Budowlany; 2022, 93, 7-8; 160--166
0033-2038
Pojawia się w:
Przegląd Budowlany
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-6 z 6

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies