Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Verdet constant" wg kryterium: Temat


Wyświetlanie 1-3 z 3
Tytuł:
New compensation scheme of magneto-optical current sensor for temperature stability improvement
Autorzy:
Chen, J.
Li, H.
Zhang, M.
Zhang, Y.
Powiązania:
https://bibliotekanauki.pl/articles/221874.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
magneto-optical current sensor
normalization
Verdet constant
birefringence
Opis:
A novel magneto-optical current sensor (MOCS) with two sensing arms is proposed to improve the temperature stability. One of the arms, with a highly stable permanent magnet attached and orthogonal to the other one, is designed to provide a reference that follows the temperature characteristics of the sensing material. By a normalization operation between two arms, the temperature drift is compensated adaptively and a sensing output proportional to the measured current can be reached. A dual-input and dual-output structure is specially designed for the reference sensing arm to demodulate the DC Faraday rotation angle. This scheme compensates simultaneously two main temperature influence factors, the Verdet constant and linear birefringence. Validation tests were carried out and are discussed.
Źródło:
Metrology and Measurement Systems; 2012, 19, 3; 611-616
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania wpływu domieszki jonów Gd3+ na własności magnetooptyczne szkła tellurowego
Studying influence of element Gd3+ on the magneto-optic properties of the tellurite glass
Autorzy:
Golis, E.
Powiązania:
https://bibliotekanauki.pl/articles/168791.pdf
Data publikacji:
2015
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Ceramiki i Materiałów Budowlanych
Tematy:
własności magnetooptyczne
stała Verdeta
szkła tlenkowe tellurowe
materiały dla optoelektroniki
magneto-optic properties
Verdet constant
tellurite oxide glasses
materials for optoelectronics
Opis:
W pracy przedstawiono wyniki badań dotyczące szkła tlenkowego tellurowego domieszkowanego jonami gadolinu. Ocenę własności magnetycznych badanych materiałów przeprowadzono określając dominujący rodzaj uporządkowania magnetycznego, przez pomiary stałopolowej podatności magnetycznej. Własności magnetooptyczne określono w oparciu o pomiary efektu Faraday’a i obliczenia stałej Verdeta na podstawie wartości kąta skręcenia płaszczyzny polaryzacji światła. Wyniki badań podatności magnetycznej wskazują na zmianę charakteru uporządkowania magnetycznego wywołanego domieszkowaniem badanego szkła jonami Gd3+. Domieszkowanie szkła tellurowego jonami gadolinu zmienia znak podatności magnetycznej, co świadczy o przejściu w uporządkowanie diamagnetyczne. Zmiana uporządkowania magnetycznego powoduje pogorszenie własności magnetooptycznych. Obserwowany na podstawie wcześniejszych badań PALS [1] wzrost defektów punktowych i wzrost rozmiarów defektów objętościowych, może mieć w tym przypadku, przy małej wartości podatności magnetycznej, wpływ na takie zachowanie się efektu magnetooptycznego. Otrzymane wyniki mogą stanowić ważne wskazania do opracowania nowych materiałów o dobrych własnościach magnetooptycznych dla zastosowań w urządzeniach optoelektronicznych.
This paper presents the results of research on the tellurite oxide glasses containing Gd3+ elements addition. The evaluation of the magnetic properties of the investigated materials was based on the determination of the dominant type of magnetic order by measuring the DC magnetic susceptibility. Their magneto-optic properties were determined on the base of the Faraday effect measurements and Verdet constant calculated from the turn angle of the surface light polarization. The results of magnetic susceptibility measurements indicate the change in the nature of magnetic ordering induced by the addition of gadolinium ions. Parent glass Te2 is a typical paramagnetic. The addition of gadolinium ions to the parent glass caused the change in magnetic ordering from paramagnetic to diamagnetic. With the change in the nature of magnetic ordering magneto-optic effect is reduced. An increase amount of point defects and an increase of average volume defect sizes that was observed on the basis of PALS [1], and a small value of magnetic susceptibility in this case may influence such behavior of the magneto-optic effect. The obtained results can provide important advises on the development of new materials possess unique magneto-optic properties for applications in optoelectronic devices.
Źródło:
Szkło i Ceramika; 2015, R. 66, nr 6, 6; 10-12
0039-8144
Pojawia się w:
Szkło i Ceramika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowanie światłowodów telekomunikacyjnych G.652, G.653 i G.655 w polarymetrycznych czujnikach natężenia prądu
Using G.652, G.653 and G.655 telecommunication optical fibers for a polarimetric current sensor
Autorzy:
Torbus, S. A.
Powiązania:
https://bibliotekanauki.pl/articles/154280.pdf
Data publikacji:
2011
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
stała Verdeta
zjawisko magnetooptyczne Faradaya
polarymetryczny czujnik natężenia prądu
światłowodowy przekładnik prądowy
światłowód jednomodowy
światłowód wielomodowy
linia wysokiego napięcia
Verdet constant
mangeto-optical phenomenon
polarimetric current sensor
optical fiber current transformer
single-mode optical fiber
multi-mode optical fiber
high-voltage line
Opis:
W artykule pokazano, że preferowane jest stosowanie światłowodów telekomunikacyjnych standardów G.652, G.653 i G.655 do wykonania cewki pomiarowej polarymetrycznego czujnika natężenia prądu, zamiast światłowodu wielomodowego. Przedstawiono wyniki symulacji dla cewek o różnej liczbie zwojów i różnych wartości natężenia prądu dla światłowodów jednomodowych i wielomodowych. Zaprezentowano również analizę dokładności pomiaru natężenia prądu za pomocą czujnika polarymetrycznego, w którym cewka pomiarowa wykonana jest ze światłowodu telekomunikacyjnego. W oparciu o symulację komputerową określono, że ułożenie przewodów linii wysokiego napięcia 110 kV nie wpływa na dokładność pomiaru rozpatrywanym czujnikiem natężenia prądu.
This paper describes benefits of using G.652, G.653 and G.655 telecommunication optical fibres for a measurement coil of the polarimetric current sensor. There are given the simulation results for coils of different number of turns and made of various optical fibres - a single-mode and multi-mode fibre. There is presented analysis of the accuracy of current measurement by means of the polarimetric sensor, in which the measurement coil is made of telecommunication optical fibers. Using the classical theory of measurement errors, it is shown that polarimetric current sensors with the measurement coil made of telecommunication optical fiber are characterised by a very high accuracy. Based on computer simulations, it was proved that the 110 kV high voltage cable laying does not affect the presented current sensor accuracy. In the presented polarimetric sensor model it was shown that the distance from the center of the high-voltage power line cable to the optical fiber should be at least 55 mm in order to prevent the impact of macrobendings. This feature will make it possible to use this sensor in remote measurement systems.
Źródło:
Pomiary Automatyka Kontrola; 2011, R. 57, nr 5, 5; 441-446
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-3 z 3

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies