Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Hall model" wg kryterium: Temat


Wyświetlanie 1-4 z 4
Tytuł:
The impact of the exhibitor’s cultural context on the use of forms of communication in the management process of the exhibitor’s participation
Autorzy:
Proszowska, Anita
Powiązania:
https://bibliotekanauki.pl/articles/685128.pdf
Data publikacji:
2015
Wydawca:
Uniwersytet Jagielloński. Wydawnictwo Uniwersytetu Jagiellońskiego
Tematy:
trade fairs, exhibitor, Hall’s model, contextuality of culture, fairs marketing communication
Opis:
The purpose of the article was to analyse the impact of the exhibitor’s cultural context on forms of communication used by exhibitors participating in fairs on culturally different markets. The article characterizes contextuality as a criterion for division of national cultures according to the E. T. Hall model and fairs marketing communication tools. Next, the analysis covers impact of cultural context on communication forms applied by exhibitors. Examples of fairs presentations of exhibitors representing cultures of high, medium and low context have been described. The paper characterizes similarities and differences between the used forms of communication. Finally, strategic implications are indicated for entities including trade fairs in their communication process with their stakeholders.
Źródło:
Jagiellonian Journal of Management; 2015, 1, 2
2450-114X
Pojawia się w:
Jagiellonian Journal of Management
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Błędne rozwiązanie konstrukcyjne stalowego stropu pod maszyny wirujące
Autorzy:
Marcinowski, J.
Powiązania:
https://bibliotekanauki.pl/articles/162111.pdf
Data publikacji:
2010
Wydawca:
Polski Związek Inżynierów i Techników Budownictwa
Tematy:
hala przemysłowa
konstrukcja stalowa
obciążenie dynamiczne
drganie wymuszone
model numeryczny
industrial hall
steel structure
dynamic load
forced vibration
numerical model
Źródło:
Przegląd Budowlany; 2010, R. 81, nr 5, 5; 94-96
0033-2038
Pojawia się w:
Przegląd Budowlany
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Użyteczność modelu obliczeniowego pojedynczej ramy poprzecznej w szacowaniu odporności ogniowej hali stalowej
The Usability of a Computational Model of a Single Transverse Frame in the Fire Resistance Assessment of an Entire Steel Hall
Autorzy:
Maślak, M.
Tkaczyk, A.
Woźniczka, P.
Powiązania:
https://bibliotekanauki.pl/articles/373628.pdf
Data publikacji:
2017
Wydawca:
Centrum Naukowo-Badawcze Ochrony Przeciwpożarowej im. Józefa Tuliszkowskiego
Tematy:
hala stalowa
odporność ogniowa
rama poprzeczna
model obliczeniowy
podejście Merchanta-Rankine’a
nośność sprężysta
nośność plastyczna
temperatura krytyczna
steel hall
fire resistance
transverse frame
computational model
Rankine-Merchant approach
purely elastic resistance
purely plastic resistance
critical temperature
Opis:
Cel: Celem zaprezentowanych rozważań jest wypracowanie miarodajnej odpowiedzi na pytanie o wiarygodność stosowania modelu obliczeniowego pojedynczej ramy poprzecznej wyizolowanej ze złożonego ustroju nośnego hali stalowej w ocenie odporności ogniowej tej hali. Badanie zachowania się w pożarze pojedynczej ramy poprzecznej poprzez weryfikację kolejnych potencjalnie możliwych form jej zniszczenia umożliwia specyfikację poszukiwanej odporności interpretowanej jako określona dla tej ramy temperatura krytyczna, niezależna od przyjętego scenariusza rozwoju pożaru. Temperatura ta kojarzona jest jednoznacznie z osiągnięciem przez ustrój nośny analizowanej ramy stanu granicznego nośności ogniowej. Metody: Do specyfikacji temperatury krytycznej wybranej ramy proponuje się procedurę obliczeniową opartą na uogólnionej na przypadek pożaru formule Merchanta-Rankine’a. Kwantyfikuje ona miarodajną nośność badanej ramy poprzez interakcję odpowiednich nośności skojarzonych z czysto sprężystą i czysto plastyczną formą jej zniszczenia. Opisano ograniczenia wybranej przez autorów metody oceny wynikające z konieczności akceptacji wielu upraszczających założeń formalnych. Pokazano również, jak na otrzymane rezultaty wpływa stopień złożoności zastosowanego modelu obliczeniowego. Wyniki: Weryfikację i walidację proponowanej w artykule procedury obliczeniowej przeprowadzono porównując przemieszczenia wybranych węzłów ramy poprzecznej hali stalowej analizowanej dla warunków pożaru. Chodziło o sprawdzenie, jakiego typu i jak duże rozbieżności wynikają z zastosowania uproszczonego modelu dwuwymiarowego pojedynczej ramy w stosunku do wyników otrzymanych z analizy pełnego trójwymiarowego modelu ustroju nośnego całej hali. Wnioski: Wykazano, że uproszczony model obliczeniowy pojedynczej ramy poprzecznej hali stalowej jest wystarczająco wiarygodny w przypadku, gdy o odporności ogniowej tej ramy decyduje pierwsza faza pożaru, gdy nie ma jeszcze znaczącego przyrostu prędkości deformacji elementów nośnych. Jeżeli jednak badana rama zapewnia bezpieczne przenoszenie przyłożonych do niej obciążeń także wtedy, gdy mamy do czynienia z dużymi deformacjami i znacznym osłabieniem elementów decydujących o nośności ramy, to oszacowanie prognozowanej odporności na podstawie modelu ograniczonego do pojedynczej ramy poprzecznej może być nazbyt optymistyczne. Nie uwzględnia bowiem przyspieszania ugięcia rygla przez ogrzane w pożarze płatwie dachowe rozciągane osiowo wskutek tak zwanego efektu cięgna.
Aim: The aim of these considerations is to achieve a reliable answer to the question about the credibility of the use of a simple computational model with a single transverse frame isolated from a complex load-bearing structure of an entire steel hall in the fire resistance-evaluation of such a hall. The study of the behaviour of a simple transverse frame under fire conditions through checking all its potential failure modes allows to specify the required fire resistance which can be interpreted as the critical temperature set especially for this frame and being independent of the fire scenario adopted for the analysis. This temperature is unequivocally associated with the reaching by the frame load-bearing structure of the fire-resistance limit state. Methods: The classical Rankine-Merchant formula generalised to the fire case is proposed to be used in the specification of the critical temperature for the transverse frame selected for the analysis. It quantifies the reliable bearing capacity of the tested frame through the interaction of the appropriate capacities associated with purely elastic and purely plastic failure modes. The limitations of the assessment method recommended by the authors are described in detail, resulting from the need for the acceptance of many formal assumptions simplifying the analysis. The impact of the complexity of the formal model adopted for the assessed frame fire-resistance evaluation on the obtained results is also verified. Results: Both the verification and the validation of the computational procedure proposed by the authors in this article were performed by comparing the displacements of the selected nodes in the transverse frame analysed for fire conditions. The idea was to check what type of differences are obtained through the use of a simplified two-dimensional computational model of a single frame in relation to the corresponding results obtained when a complex three-dimensional model of the entire hall is considered, and how big they are. Conclusions: It has been shown that the simplified computational model of a single transverse frame selected from the entire steel hall seems to be sufficiently reliable in the case in which fire resistance of such a frame is determined by the first phase of this fire, when the deformation rate of all bearing members is not yet significantly increased. However, if the tested frame also ensures the safe transfer of all loads applied to it when we are dealing with large deformations and large weakening of the members determining the real capacity of such a frame then the assessment of the predicted fire resistance obtained on the basis of the model limited to the analysis of only a single transverse frame might prove to be too optimistic. It does not account for the acceleration of the deflection of the frame beam due to the action of the heated purlins being in tension as a consequence of the so called catenary effect.
Źródło:
Bezpieczeństwo i Technika Pożarnicza; 2017, 45, 1; 52-67
1895-8443
Pojawia się w:
Bezpieczeństwo i Technika Pożarnicza
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowanie zaawansowanej metody oceny odporności ogniowej w budownictwie przemysłowym
Application of advanced fire resistance assessment method for industrial structures
Autorzy:
Woźniczka, Piotr
Powiązania:
https://bibliotekanauki.pl/articles/128943.pdf
Data publikacji:
2020
Wydawca:
PWB MEDIA Zdziebłowski
Tematy:
ocena odporności
odporność ogniowa
hala stalowa
symulacja
rozwój pożaru
odpowiedź mechaniczna
modelowanie konstrukcji
temperatura krytyczna
model zniszczenia
resistance assessment
fire resistance
steel hall
simulation
fire development
mechanical response
structure modelling
critical temperature
failure mode
Opis:
W artykule przedstawiono przykład opracowanej oceny odporności ogniowej obiektu przemysłowego. Dla rozpatrywanej hali maszynowni o konstrukcji stalowej zaprezentowano wyniki symulacji rozwoju pożaru oraz odpowiedzi mechanicznej konstrukcji. Obliczenia przeprowadzono za pomocą zaawansowanych programów komputerowych. Omówiono wpływ takich czynników, jak nierównomierne ogrzewanie oraz sposób modelowania konstrukcji na szacowaną odporność ogniową. Wskazano także wartości temperatury krytycznej oraz prognozowane modele zniszczenia. Wykazano, że omawiana metoda może być z powodzeniem stosowana w odniesieniu do rozpatrywanej kategorii obiektów.
Both fire development and mechanical response analysis of the steel turbine hall are described. Factors like non-uniform heating and way of structural modeling and their impact on the anticipated fire resistance of the structure are discussed. Moreover, values of the crictical temperature and predicted failure modes are given. As a result it is shown that described method is appropriate for the considered type of buildings.
Źródło:
Builder; 2020, 24, 4; 58-60
1896-0642
Pojawia się w:
Builder
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-4 z 4

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies