Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Marcinowski, P." wg kryterium: Autor


Wyświetlanie 1-3 z 3
Tytuł:
Oczyszczanie ścieków z przemysłu kosmetycznego za pomocą procesu koagulacji
Cosmetic wastewater treatment by coagulation
Autorzy:
Naumczyk, J.
Marcinowski, P.
Wiliński, P.
Bogacki, J.
Powiązania:
https://bibliotekanauki.pl/articles/1818746.pdf
Data publikacji:
2013
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
oczyszczanie ścieków
proces koagulacji
polycyclic musk fragrances
sewage treatment plant
contrast media
uv filters
removal
pharmaceuticals
oxidation
ahtn
hhcb
wastewaters
Opis:
In this study the coagulation process of five cosmetics wastewater types has been investigated. All samples were collected from big cosmetic factory in Poland. Due to changeable production profile, also significant changeability of the wastewater composition and the concentration of pollutants were observed. COD values of raw wastewaters samples 1, 2, 3, 4 and 5 were as follows: 7293, 3241, 3241, 5132 and 1089 mg/l, respectively. Before coagulation easily settleable suspended solids were removed by 30 min primary sedimentation. After sedimentation COD values were decreased to 1134, 2512, 3241, 1858 and 1089 mg/l, respectively. Coagulation with Al2 (SO4)3 at pH 7.0 and FeCl3 at pH 6.0 and 9.0 allowed to achieve COD removal in the range of 33.0–63.5%. The effect of coagulation was better for the samples of lower contents of easily settleable suspended solids and higher content of fine suspended solids. The best effects of COD removal by coagulation achieved for investigated wastewaters were as follow: sample 1 – 39.2%, by Al2 (SO4) 3 and FeCl3 at pH 9.0; sample 2 – 54.8%, by FeCl3 at pH 6.0; sample 3 – 60.0%, by Al2 (SO4) 3; sample 4 – 33.3%, by Al2 (SO4) 3; sample 5 – 63.5%, by FeCl3 at pH 6.0. The differences in coagulants effectiveness were not significant. Flopam flocculant improved the effect of coagulation – shortened the clarification time from 60 min to 5 min, reduced the coagulant doses by about 50 mg/l and increased COD removal. In the coagulation assisted by Flopam flocculant, Al2 (SO4) 3 proved to be the best coagulant for sample 3 (62.5%), FeCl3 at pH 6.0 was the best for sample 2 (54.8%) and sample 5 (63.9% – the best result of all) and FeCl3 at pH 9.0 for sample 4 (50.0%). The best effect of coagulation was achieved for sample no 5, which had no easily settleable suspended solids. The total effect of COD removal, including primary sedimentation and coagulation ranged from 63.9 to 90.6%. GC-MS analysis allowed to identify 110 compounds. The predominant compounds identified by GC-MS were: cyclopentasiloxane, decamethylcyclopentasiloxane and synthetic musk – galaxolide (HHCB). HHCB concentration was decreased in the coagulation by 87.3–92.2%. The degree of other compounds removal varied in the range 0–99.4%.
Źródło:
Rocznik Ochrona Środowiska; 2013, Tom 15, cz. 1; 873-891
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Nośność wyboczeniowa żeber wzmacniających ściany stalowego silosu na zboże
Buckling resistance of vertical stiffeners of steel silos for grain storage
Autorzy:
Błażejewski, P.
Marcinowski, J.
Powiązania:
https://bibliotekanauki.pl/articles/389936.pdf
Data publikacji:
2013
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Tematy:
silos stalowy
żebra pionowe
stalowe elementy zimnogięte
nośność wyboczeniowa
imperfekcja
procedura numeryczna
steel silo
vertical stiffeners
cold formed section
buckling resistance
imperfections
numerical procedure
Opis:
Siły południkowe w silosie stalowym, którego ściany są wykonane z blachy profilowanej poziomo są przenoszone przez żebra pionowe. Elementy te są zazwyczaj wykonywane z cienkościennych kształtowników zimnogiętych wrażliwych na miejscową utratę stateczności. W pracy przedstawiono numeryczną procedurę oszacowania nośności wyboczeniowej rodziny żeber wykonanych z blach o różnej grubości. Uwzględniono imperfekcje w postaci pierwszej formy wyboczenia i amplitudach do wartości 4t włącznie. Wyniki porównano z bardzo zachowawczymi wartościami nośności wyboczeniowej takich elementów proponowanymi w zapisach normy PN-EN1993-4-1.
In steel silos fabricated from horizontally corrugated sheets, the vertical stiffeners (columns) sustain vertical forces as a result of friction of a bulk material against the silo wall. Columns are usually of cold formed steel sections. Due to the fact that stiffener failures are the most frequent cause of silos collapses, it is important to estimate accurately their resistance. The paper deals with numerical modelling of the elastic-plastic collapse of columns. Geometrically and materially nonlinear analyses (GMNIA) were carried out in which imperfections were taken into account. The imperfection forms were taken as a first buckling mode obtained in the linear buckling analysis (LBA). Amplitudes of imperfections were assumed as a =t, 2t, 3t, 4t, where t is the thickness of the stiffeners wall. It was revealed that the buckling resistance is very sensitive to the imperfection amplitude. All numerical analyses were performed by the COSMOS/M system based on FEM. Buckling resistance of all analysed stiffeners was calculated also by means of formulae inserted in Eurocode PN-EN1993-4-1. Buckling resistances obtained by the proposed numerical approach were greater than their counterparts being the result of provisions inserted in PN-EN1993-4-1 and appear to be more realistic.
Źródło:
Budownictwo i Architektura; 2013, 12, 2; 189-196
1899-0665
Pojawia się w:
Budownictwo i Architektura
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Najbardziej niekorzystne imperfekcje geometryczne stalowych powłok sferycznych
Most adverse geometrical imperfections of steel spherical shells
Autorzy:
Błażejewski, P.
Marcinowski, J.
Powiązania:
https://bibliotekanauki.pl/articles/391121.pdf
Data publikacji:
2014
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Tematy:
powłoka sferyczna
utrata nośności
MES
imperfekcja geometryczna
spherical shell
geometrical imperfections
FEM
worst imperfection
buckling resistance
GMNIA
Opis:
Stalowe powłoki sferyczne obciążone ciśnieniem zewnętrznym narażone są na utratę stateczności, która najczęściej decyduje o ich nośności. Występujące w tego typu konstrukcjach imperfekcje geometryczne mogą znacząco wpłynąć na obniżenie nośności powłoki. Analizowane dotychczas formy imperfekcji, w postaci pierwszej i drugiej formy wyboczeniowej, nie wyczerpują możliwych do zaobserwowania w rzeczywistości niedoskonałości geometrycznych. Zestawienie i porównanie innych, spotykanych w praktyce imperfekcji geometrycznych pozwoli określić najbardziej niekorzystną z nich. Dodatkowe uwzględnienie normowych amplitud imperfekcji, dla każdej z form, pozwoliło określić przedziały amplitud, w których dana forma jest rzeczywiście najbardziej niekorzystna. Taka informacja pozwoli inżynierom uniknąć błędnego przyjęcia najbardziej niekorzystnej imperfekcji dla założonej klasy wykonania powłoki sferycznej.
Steel, spherical shells subjected to an external pressure are exposed to the loss of stability and such a phenomenon determines the global resistance of such shells. Unavoidable, geometric imperfections present is this class of shells affect significantly global resistance of shells. The imperfection form corresponding to the first and second buckling modes, analysed in previous works of authors, do not cover all possible and observed in reality imperfection modes. The specification and comparison of other imperfections encountered in practice will allow to identify the most adverse ones. Additionally to the imperfection forms also their amplitudes were analysed. Consequently the ranges in which considered imperfection form is in fact the most adverse were determined. On the basis of this knowledge, the designer can choose the most adverse imperfection mode for given quality fabrication class of the shell.
Źródło:
Budownictwo i Architektura; 2014, 13, 3; 219-226
1899-0665
Pojawia się w:
Budownictwo i Architektura
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-3 z 3

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies