Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "S. R." wg kryterium: Autor


Wyświetlanie 1-1 z 1
Tytuł:
Histopathologischer gelenk-endoprothesen-partikelalgorithmus
Autorzy:
KRENN, V.
THOMAS, P.
THOMSEN, M.
KRETZER, J.P.
USBECK, S.
SCHEUBER, L.
RÜTHER, W.
WELSER, R.V.
HOPF, F.
HUBER, M.
Powiązania:
https://bibliotekanauki.pl/articles/1033752.pdf
Data publikacji:
2014
Wydawca:
Zakład Opieki Zdrowotnej Ośrodek Umea Shinoda-Kuracejo
Tematy:
SLIM
aseptic prosthesis loosening
joint prosthesis
particle algorithm
wear particles
Opis:
Materials from joint endoprothesis are the source for particle induced reactions in the SLIM (Synovia Like Interface Membrane) which are relevant for endoprosthetic pathologies especially in aseptic prosthesis loosening. The identification of wear particles in the SLIM is due to the heterogeneity of implant materials, due to the complexity of particle genesis and its differential diagnosis to non prosthesis-material particles a great challenge for histopathologists. This “particle algorithm” is based on 1) conventional transmitted light microscopy with a guide to sizing, shaping and coloring 2) polarization optical criteria and 3) enzyme-histochemical properties (oil red O staining and Prussian blue reaction). Based on these criterias the complete spectrum of particles in the SLIM may be defined including non-ferrous metals and metal alloys, ferrous metals, wear particle corrosion, ceramic particles, bone cement (polymethyl methacrylate, PMMA) particles, PMMA additives such as X-ray contrast medium (zirconium dioxide or barium sulfate), and non-metallic and non-ceramic materials (polyethylene particles, carbon particles, silicon). The most relevant non prosthesis-material particles include calciumpyrophosphate, urate, calciumcar-bonates and hemosiderin. Since in principle all wear particles may exert inflammatory or immunological properties, the diagnosis of particle induced inflammatory or immunological reactions should be carried out in the context of the Consensus-Classification of the SLIM leading to a definite SLIM type classification. In respect of the particle heterogeneity an open web based “particle algorithme” would be helpful which could include all material particles in a rapid changing field of material science. For histopathological diagnosis a “particle score” for the SLIM is recommended evaluating 1) the predominant prosthesis-material particle type in respect to micro-, and macroparticles, 2) the existence of non prosthesis-material particles and 3) the quantification of particle induced necrosis and lymphocytosis.
Źródło:
Medicina Internacia Revuo; 2014, 26, 102; 47- 66
0465-5435
Pojawia się w:
Medicina Internacia Revuo
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-1 z 1

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies