Vacuum circuit breakers in high and highest voltage grids
Zastosowanie wyłączników próżniowych w sieciach wysokich i najwyższych napięć
Autorzy:
Kubek, P.
Powiązania:
https://bibliotekanauki.pl/articles/397039.pdf
Data publikacji:
2017
Wydawca:
ENERGA
Tematy:
vacuum insulation technology
vacuum circuit breaker
SF6 circuit breaker
próżniowa technika izolacyjna
wyłącznik próżniowy
wyłącznik SF6
Opis:
Recently, there has been a noticeable increase in the interest of grid operators in the application of vacuum technology in high and highest voltage overhead grids. For many years vacuum circuit breakers have been used in medium voltage grids, but in the past years mainly due to environmental conditions, vacuum technology has been developed also for high and highest voltages. Application of vacuum circuit breakers in high and highest voltage grids requires considering many technical factors that are characterized in this paper. Its main aim is to review the existing solutions of high voltage vacuum circuit breakers and to compare them with SF6 gas circuit breakers. It also discusses technical aspects of high voltage vacuum circuit breakers’ disadvantages and advantages, as well problems of their designing.
W ostatnim czasie można zauważyć intensywny wzrost zainteresowania operatorów sieciowych wykorzystaniem techniki próżniowej w sieciach napowietrznych wysokiego i najwyższego napięcia. Od wielu lat wyłączniki próżniowe są stosowane w sieciach średniego napięcia, jednak w minionych latach głównie ze względu na uwarunkowania środowiskowe technologia próżniowa rozwijana jest także w zakresie wysokich i najwyższych napięć. Zastosowanie wyłączników próżniowych w sieciach WN i NN wymaga uwzględnienia wielu czynników technicznych, które scharakteryzowano w artykule. Głównym celem artykułu jest dokonanie przeglądu istniejących rozwiązań wyłączników próżniowych wysokiego napięcia oraz ich porównanie z wyłącznikami z gazem SF6. Artykuł zawiera także omówienie aspektów technicznych dotyczących wad i zalet, a także problemów dotyczących projektowania wyłączników próżniowych wysokiego napięcia.
Źródło:
Acta Energetica; 2017, 3; 124-130
2300-3022
Pojawia się w:
Acta Energetica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Explosive Device for Current Switching
Urządzenie wybuchowe do wyłączania prądu
Autorzy:
Bogdanovich, P. T.
Komorny, A. A.
Tarnopolsky, A. B.
Powiązania:
https://bibliotekanauki.pl/articles/354192.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
explosive opening switch
cumulation
wybuchowy wyłącznik prądu
kumulacja
Opis:
The present paper deals with explosive devices for switching of kiloampere and megaampere current. The parameters of cumulation from a grooved surface and the parameters of shaped charge jet penetration into a barrier were analyzed depending on the initial properties of the explosive charge, the inert material and the barrier.
Przedmiotem pracy jest analiza zjawisk zachodzących w urządzeniach do wyłączania prądu o natężeniu rzędu kilo- lub mega- amperów, wykorzystujących energię wybuchu. Proces wybuchu analizowano w zależności od początkowych właściwości ładunku wybuchowego, materiału elementu napędzanego (masy inercyjnej) oraz materiału bariery.
Źródło:
Archives of Metallurgy and Materials; 2014, 59, 3; 1115-1118
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Vacuum circuit breaker switching in medium voltage networks with photovoltaic panels at low voltage side working as a supply source
Operacje łączeniowe wyłącznikiem próżniowym w sieciach średniego napięcia z uwzględnieniem paneli fotowoltaicznych pracujących po stronie niskiego napięcia jako źródło zasilania
Autorzy:
Kuczek, T.
Florkowski, M.
Powiązania:
https://bibliotekanauki.pl/articles/268833.pdf
Data publikacji:
2012
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
panel fotowoltaiczny
wyłącznik próżniowy
przepięcia
PV cell
vacuum circuit breaker
overvoltage
Opis:
Breaking of inductive currents with use of vacuum circuit breaker is related to a problem of current chopping before its natural zero crossing. Due to the energy trapped in oscillatory circuit consisting of transformer's inductance and capacitance, the voltage across circuit breaker contacts starts to oscillate. Breaking of dielectric withstand can lead to multiple arc re-ignitions, which can result in generation of waveforms with high steepness and overvoltage peak values. In the present article, the principle of those phenomena was explained. Simulation results of circuit breakers opening operation in medium voltage network consisting of transformer with photovoltaic panels connected at low voltage side was also presented.
Wyłączniki próżniowe stosowane w elektroenergetyce średnich napięć charakteryzują się efektem tzw. ucięcia prądu przed jego naturalnym przejściem przez zero. Z powodu energii zmagazynowanej w indukcyjności oraz pojemności transformatora, podczas operacji otwierania napięcie powrotne pomiędzy zaciskami wyłącznika zaczyna oscylować. W momencie przekroczenia wytrzymałości dielektrycznej pomiędzy zaciskami, następuje ponowny zapłon łuku elektrycznego. Zjawisko to może doprowadzić to powstania przepięć o wysokiej stromości oraz wartościach szczytowych. W pracy zaprezentowano wyniki symulacji procesu otwierania wyłącznika próżniowego w sieci z transformatorem zasilanym ze strony niskiego napięcia poprzez panele fotowoltaiczne.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2012, 31; 85-88
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Evaluation of Applicability of Classic Methods of a Fault Loop Impedance Measurement to Circuits with Residual Current Devices
Ocena przydatności klasycznych metod pomiaru impedancji pętli zwarciowej do obwodów z wyłącznikami różnicowoprądowymi
Autorzy:
Czapp, S.
Borowski, K.
Powiązania:
https://bibliotekanauki.pl/articles/397224.pdf
Data publikacji:
2016
Wydawca:
ENERGA
Tematy:
wyłącznik różnicowoprądowy
impedancja pętli zwarciowej
pomiary
residual current device
fault loop impedance
measurements
Opis:
Measurement of fault loop impedance in low voltage grids and systems is in most cases performed to verify the effectiveness of protection against electric shock by automatic disconnection of supply. For the sake of measurement accuracy, it is advisable to perform it using large current. Unfortunately, in circuits with residual current devices which are very widely used nowadays, a large measurement current may trigger those devices unnecessarily. The study presents results of an investigation of residual current devices behaviour during measurements of fault loop impedance performed with selected measuring devices. The tests have been performed on circuits with residual current devices with a rated residual operating current IΔn = 30 mA, of AC and A type. Based on the performed tests and analyses, a method for measurement of fault loop impedance which does not unnecessarily trigger residual current devices has been proposed.
Pomiar impedancji pętli zwarciowej w sieciach i instalacjach niskiego napięcia wykonuje się najczęściej w celu oceny skuteczności ochrony przeciwporażeniowej przez samoczynne wyłączanie zasilania. Z punktu widzenia dokładności pomiaru korzystne jest, aby wykonać go dużym prądem. Niestety, w obwodach z wyłącznikami różnicowoprądowymi, które obecnie są stosowane na bardzo szeroką skalę, duży prąd pomiarowy może powodować ich zbędne wyzwalanie. W pracy przedstawiono wyniki badań zachowania się wyłączników różnicowoprądowych przy pomiarze impedancji pętli zwarciowej, wykonanym wybranymi miernikami. Badania przeprowadzono w obwodach z wyłącznikami różnicowoprądowymi o prądzie znamionowym różnicowym IΔn = 30 mA, typu AC oraz typu A. Na podstawie przeprowadzonych badań i analiz zaproponowano sposób pomiaru impedancji pętli zwarciowej, który nie powoduje zbędnego zadziałania wyłączników różnicowoprądowych.
Źródło:
Acta Energetica; 2016, 3; 45-52
2300-3022
Pojawia się w:
Acta Energetica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Method of measurement and reduction of the electromagnetic disturbances inducted by switching surges in LV circuits
Metoda pomiaru i redukcji zaburzeń elektromagnetycznych indukowanych przez przepięcia łączeniowe w obwodach nN
Autorzy:
Wąsik, Patryk D.
Powiązania:
https://bibliotekanauki.pl/articles/2070265.pdf
Data publikacji:
2021
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Tematy:
EMI
circuit breaker
fast measurement method
LV circuits
wyłącznik nadprądowy
szybka metoda pomiarowa
obwody nN
Opis:
This paper presents a fast, reliable and portable method for measuring electromagnetic disturbances in LV circuits (overcurrent circuit breakers). The experiment was carried out under conditions reflecting the real measurement environment. The method was verified and confirmed by a series of measurements with passive components reducing the disturbance. The results of the measurements made it possible to obtain suitable EMI reduction solutions, which can be used to protect commutators or end consumers. The results obtained make it possible to apply the method to measurements of multichannel circuit breakers, in which measuring the turn-on time of individual channels is important for the correct operation of the devices.
W artykule przedstawiono szybką, niezawodną i przenośną metodę pomiaru zaburzeń elektromagnetycznych w obwodach nN (wyłączniki nadprądowe). Eksperyment przeprowadzono w warunkach odzwierciedlających rzeczywiste środowisko pomiarowe. Metoda została zweryfikowana i potwierdzona serią pomiarów z elementami pasywnymi redukującymi zaburzenia. Wyniki pomiarów pozwoliły na uzyskanie odpowiednich rozwiązań redukcji zaburzeń elektromagnetycznych. Dobrane komponenty mogą być wykorzystane do ochrony komutatorów lub odbiorników końcowych. Uzyskane wyniki pozwalają na zastosowanie metody do pomiarów wyłączników wielobiegunowych, w których pomiar czasu załączenia poszczególnych biegunów jest istotny dla poprawnej pracy urządzeń.
Źródło:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska; 2021, 11, 4; 55--61
2083-0157
2391-6761
Pojawia się w:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Changes to the SF6 outflow area in the nozzle of a high voltage auto-pneumatic circuit breaker during a short-circuit current interruption
Zmiany przekroju krytycznego dyszy SF6 auto-pneumatycznego wysokonapięciowego wyłącznika podczas wyłączania prądu zwarciowego
Autorzy:
Sibilski, H.
Dzierżyński, A.
Hejduk, A.
Kuraszkiewicz, J.
Powiązania:
https://bibliotekanauki.pl/articles/952441.pdf
Data publikacji:
2016
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Elektrotechniki
Tematy:
HV puffer circuit breaker
SF6
nozzle
ablation
gas flow
wyłącznik autopneumatyczny
dysza
ablacja
przepływ gazu
Opis:
The paper presents a calculation method for the SF6 outflow area across the critical cross-section of the nozzle in an HV puffer circuit breaker during the interruption of a short-circuit current. The presence of an electrical arc can cause clogging of the nozzle at the moment when the arc cross section is close to the nozzle throat area. The clogging depends on the instantaneous current value and can cause ablation of the nozzle material. In the long term it can result in a change in the nozzle dimensions which adversely affects the interrupting ability of the circuit breaker.
W artykule podano sposób obliczania wypływu gazu SF6 w przekroju krytycznym dyszy w wyłącznikach autopneumatycznych. W wyniku działania łuku elektrycznego podczas wyłączania prądu zwarciowego może dochodzić do zatykania dyszy i wzrostu ciśnienia, a po wielokrotnych wyłączeniach w wyniku wysokiej temperatury łuku może wystąpić deformacja dyszy i pogorszenie własności łączeniowych. Do obliczeń przyjęto wyłącznik z napędem pneumatycznym, posiadający komorę roboczą i tłumiącą. Po rozejściu się styków zapala się łuk, który wydłużony do przekroju krytycznego dyszy zatyka częściowo dyszę zwiększając w efekcie ciśnienie w objętości dyszy wskutek wzrostu temperatury gazu. Po wielokrotnych wyłączeniach prądu zwarciowego wysoka temperatura powoduje degradację powierzchni w przekroju krytycznym dyszy i w efekcie powiększenie przekroju dyszy, co może zmienić parametry łączeniowe wyłącznika.
Źródło:
Prace Instytutu Elektrotechniki; 2016, 273; 25-34
0032-6216
Pojawia się w:
Prace Instytutu Elektrotechniki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Vacuum chamber design for HV circuit breakers
Projektowanie komór próżniowych do wyłączników wysokiego napięcia
Autorzy:
Krasuski, K.
Sibilski, H.
Błażejczyk, T.
Kozak, S.
Dzierżyński, A.
Hejduk, K.
Powiązania:
https://bibliotekanauki.pl/articles/158641.pdf
Data publikacji:
2018
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Elektrotechniki
Tematy:
styki komory próżniowej
rozkład AMF
łuk dyfuzyjny
wyłącznik
vacuum chamber contacts
AMF distribution
diffusion arc
circuit breaker
Opis:
W artykule przedstawiono opis modelu komory próżniowej przeznaczonej do wyłącznika wysokiego napięcia. Model został przeanalizowany i częściowo zbadany w celu zapewnienia odpowiedniej wytrzymałości elektrycznej i mechanicznej. Wstępnie rozważono: wytrzymałość termiczną w warunkach obciążeniowych i zwarciowych, wytrzymałość na narażenia elektryczne, przeanalizowano rozkład pola magnetycznego na powierzchni styków jak i w przestrzeni pomiędzy stykami, wyznaczono rozkład pola elektrycznego wewnątrz komory próżniowej. Styki bipolarne zbadano w rozbieralnej komorze próżniowej. Celem tych obliczeń i badań było opracowanie odpowiedniej geometrii i rozważenie możliwości techno-logicznych wykonania modelu komory do wyłącznika wysokiego napięcia.
The paper presents a vacuum chamber model for a HV circuit breaker. Manufacturers of vacuum circuit breakers apply the axial magnetic field (AMF) to stabilise the electric arc diffusion during current breaking process. The model was analyzed and partly tested to assure its mechanical and electrical withstand. The results of the preliminary calculations of thermal behavior of the vacuum chamber in short-circuit conditions, the magnetic field distribution between contact plates as well as in the contact gap and the dielectric stress inside of the vacuum chamber are shown. The bipolar contacts were tested in a dismountable vacuum chamber. The aim was to determine geometry and to recognize technology and manufacturing facilities required.
Źródło:
Prace Instytutu Elektrotechniki; 2018, 278; 61-72
0032-6216
Pojawia się w:
Prace Instytutu Elektrotechniki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Researches and tests of high-speed circuit breakers for rolling stock and substations in 3 kV DC traction power system
Badania pojazdowych i podstacyjnych wyłączników szybkich w systemie zasilania trakcji 3 kV DC
Autorzy:
Rojek, A.
Sidorowicz, M.
Powiązania:
https://bibliotekanauki.pl/articles/952291.pdf
Data publikacji:
2013
Wydawca:
Instytut Kolejnictwa
Tematy:
wyłącznik szybki
zwarcia
prąd krytyczny
koordynacja zabezpieczeń
high-speed circuit breaker
short circuit
critical currents
coordination of protection
Opis:
Before placing in service in the railway electrical traction high-speed circuit-breakers shall be the subject of conformity tests with standards. The high-speed circuit breakers are an essential safeguard against the flow of an excessive current in the circuit overhead line and vehicles being powered by it. That is the reason why the circuit breakers must be equipped with systems which allow extinguish the high-energy arc. Additionally, the short circuit currents must be switched off as soon as possible to minimize the risk of damage, protected by circuit breakers, elements of an electric traction power supply system. The main document identifying requirements and a scope of the high-speed DC circuit breakers research for traction substation and sectioning cabins is the PN-EN 50123-2 standard. In the case of the on- board high-speed DC circuit breakers, requirements and scope of the research regulates the PN-EN 60077-3 standard. Although, two standards - PN-EN 50123 and PN-EN 60077-3 - apply to the same type of electric gear, the symbols and volume and parameter indexes used therein are different, what causes some inconvenience in analysis and results comparison, especially in terms of circuit breaker cooperation (f.e. in ensuring the coordination of short circuit protection in the traction vehicle - traction substation relation). Besides above standards, the requirements for high-speed DC circuit breakers are contained in PN-EN 50388 standard and technical specification for interoperability of the subsystem “Energy” (TSI “Energy”). For most of the test points and high speed D.C. circuit breaker checks, requirements that are contained in standards, testing and results are not problematic. However, part of the research and their result may be the basis of a discussion about real properties and parameters of circuit breakers. These tests and checks are contact life research, switching capacity check, designation and critical currents switching off and coordination of short circuit protection in the traction vehicle - traction substation relation. The data analysis presented by the producers of circuit breakers show that none of them classifies their products as one of the type: H, V or S, that are defined by PN-EN 50123 standard. Based on many measurements performed by Instytut Kolejnictwa it is possible to determine the type of high-speed D.C. circuit breakers designed to 3 kV D.C. system, produced by the leading European companies. The example of the current limiting very high-speed circuit breaker type V that is produced in Poland can be taken only one of a type DCN. The current limiting high-speed circuit breaker type H is a one of a series BWS, while circuit breakers UR40 is classified to the semi-high-speed circuit breaker type S. The next “imperfection” of the standards containing the requirements for high-speed D.C. circuit breakers is a guideline for short circuit. In such a short circuit should be only inductance and resistance. Whereas in the real conditions in short circuits, where high-speed circuit breakers are working, there are capacities, for example as filters in traction vehicles. Analyzing the short circuit current flow it can be stated that switching on of resonance filter caused extra switching off time about 10%. As a result of later release and oscillating changes of short circuit current, the value of maximum limiting short circuit current increases about 15%. The critical currents switching off are bonded with relatively long burning arc on the contacts of circuit breaker. The burning time of an arc while small values of currents switching off is form over a dozen to ten times longer, than short circuit currents. By this time, which can be up to few or even several seconds, the circuit breaker contacts are exposed to arc, arcing horns and arc chamber. It causes significant arcing erosion of these elements. The standards do not define at what time critical currents should be switched off and do not specify which critical currents value should be taken as a result of tests. To achieve selectivity of short circuit and overload currents switching offs forming in rolling stock is possible while on-board circuit breaker switches off the current before the circuit breaker for use in substations and sectioning cabins will get tripped. It will happen only when on-board circuit breaker limits the current to a value lower than the tripping level of the circuit breaker for use in the fixed installations. It will happen when steepness of short circuit grow is small enough that on-board circuit breaker starts to limit the current before it reaches the tripping level of high-speed circuit breaker for use in substation. The limit value di/dt, at which short circuit current will be switched off only be the on-board circuit breaker depends on independent opening time of on-board circuit breaker, its limiting current capacity and the difference between the value of setting of on-board circuit breaker for use in fixed installations. The results of the simulation, analysis and tests show, that it is not, at the moment, possible to obtain selective short circuit switching offs in rolling stock. At the European market of circuit breakers the greatest range of selectivity show vacuum circuit breakers DCN-L and DCU using in rolling stock.
Przed dopuszczeniem do eksploatacji w kolejowej trakcji elektrycznej wyłączniki szybkie prądu stałego muszą być poddane badaniom na zgodność z normami. Wyłączniki szybkie są podstawowym zabezpieczeniem przed przepływem nadmiernych wartości prądu w obwodach sieci trakcyjnej oraz zasilanych z niej pojazdów. Dlatego muszą być wyposażone w układy umożliwiające zgaszenie łuku o dużej energii. Dodatkowo prądy zwarciowe muszą być wyłączone w jak najkrótszym czasie, aby zminimalizować ryzyko uszkodzenia chronionych przez wyłączniki elementów systemu zasilania trakcji elektrycznej. Podstawowym dokumentem, określającym wymagania i zakres badań wyłączników szybkich prądu stałego przeznaczonych do podstacji trakcyjnych i kabin sekcyjnych, jest norma PN EN 50123-2. W przypadku wyłączników szybkich przeznaczonych do eksploatacji w pojazdach trakcyjnych wymagania i zakres badań reguluje norma PN-EN 60077-3. Pomimo, że obydwie normy dotyczą tego samego typu aparatów elektrycznych, stosowane w nich oznaczenia i indeksy wielkości i parametrów są inne, co powoduje pewne niedogodności w analizach i porównywaniu wyników, w szczególności w aspekcie współpracy wyłączników, np. przy zapewnianiu koordynacji zabezpieczeń zwarciowych w układzie pojazd trakcyjny – podstacja trakcyjna. Oprócz wymienionych norm, wymagania dla wyłączników szybkich są zawarte w normie PN-EN 50388 oraz specyfikacji technicznej interoperacyjności podsystemu „Energia”. Dla większości punktów zakresu badań i sprawdzeń wyłączników szybkich, wymagania zawarte w normach oraz przeprowadzenie i wyniki badań nie są problematyczne. Jednak część badań i ich wynik mogą być podstawą dyskusji dotyczących rzeczywistych właściwości i parametrów wyłączników. Do tych badań i sprawdzeń należą badanie trwałości łączeniowej, sprawdzenie zdolności łączeniowej prądów zwarciowych, wyznaczenie i wyłączenie prądów krytycznych i koordynacja zabezpieczeń zwarciowych w układzie pojazd trakcyjny – podstacja trakcyjna. Wyniki analizy danych przedstawianych przez producentów wyłączników pokazują, że żaden z nich nie klasyfikuje produkowanych wyłączników jako jednego z typów: H, V lub S, zdefiniowanych w normie PN-EN 50123. Na podstawie pomiarów prowadzonych przez Instytut Kolejnictwa jest możliwe określenie typu wyłączników szybkich prądu stałego przeznaczonych do systemu 3 kV DC, produkowanych przez czołowe firmy europejskie. Za wyłącznik typu V można uznać jedynie wyłącznik typu DCN. Wyłącznikiem typu H jest wyłącznik serii BWS, natomiast parametry wyłączników typu UR40. Kolejną „niedoskonałością” norm zawierających wymagania dla wyłączników szybkich prądu stałego, jest wytyczna dotycząca obwodu zwarciowego. W obwodzie tym powinny występować jedynie indukcyjność i rezystancja. Natomiast w warunkach rzeczywistych w obwodach zwarciowych, w których pracują wyłączniki szybkie występują pojemności, np. w postaci urządzeń wygładzających w podstacjach trakcyjnych lub filtrów wejściowych w pojazdach trakcyjnych. Analizując wyniki badań zwarciowych można stwierdzić, że załączenie urządzenia wygładzającego spowoduje wydłużenie czasu wyłączania o około 10%. W wyniku późniejszego wyzwolenia oraz oscylacyjnych zmian prądu zwarciowego, wartość maksymalnego ograniczonego prądu zwarcia zwiększa się o około 15%. Wyłączanie prądów krytycznych wiąże się ze stosunkowo długotrwałym paleniem łuku na stykach wyłącznika. Czas palenia się łuku przy wyłączaniu prądów o małej wartości jest od kilkunastu do kilkudziesięciu razy dłuższy, niż w przypadku wyłączania prądów zwarciowych. Przez ten czas, który może dochodzić do kilku, a nawet kilkunastu sekund, na działanie łuku są narażone styki wyłącznika, rożki łukowe i komora łukowa. Powoduje to znaczną erozję łukową tych elementów. Normy nie definiują w jakim czasie prądy krytyczne powinny być wyłączane oraz nie określają jaką wartość prądów krytycznych należy przyjmować jako wynik badań. Uzyskanie selektywności wyłączeń prądów zwarciowych i przetężeniowych powstających w taborze jest możliwe wówczas, gdy wyłącznik taborowy wyłączy prąd zanim zostanie wyzwolony wyłącznik w podstacji trakcyjnej lub w kabinie sekcyjnej. Nastąpi to tylko w przypadku, gdy wyłącznik taborowy ograniczy prąd do wartości niższej od poziomu wyzwolenia wyłącznika podstacyjnego. Wystąpi to w przypadku, gdy stromość wzrostu prądu zwarciowego będzie na tyle mała, że wyłącznik taborowy zacznie ograniczać prąd zanim osiągnie on poziom wyzwalania wyłącznika szybkiego w podstacji. Wartość graniczna di/dt, przy której prąd zwarciowy będzie wyłączany tylko przez wyłącznik taborowy, zależy od czasu własnego otwarcia wyłącznika w pojeździe, jego zdolności ograniczania prądu i różnicy pomiędzy wartościami nastaw wyłączników taborowego i podstacyjnego. Wyniki symulacji, analiz i badań pokazują, że obecnie nie jest możliwe uzyskanie każdorazowo selektywności wyłączeń prądów zwarciowych w taborze. Największy zakres selektywności można uzyskać w przypadku zastosowania w taborze próżniowych wyłączników serii DCN-L i DCU.
Źródło:
Problemy Kolejnictwa; 2013, 159; 7-30
0552-2145
2544-9451
Pojawia się w:
Problemy Kolejnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Investigation of unipolar contacts with axial magnetic field
Badania styków unipolarnych o osiowym polu magnetycznym
Autorzy:
Krasuski, K
Powiązania:
https://bibliotekanauki.pl/articles/952437.pdf
Data publikacji:
2014
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Elektrotechniki
Tematy:
distribution of the magnetic field
electric arc
vacuum circuit breaker
breaker
unipolar contacts
rozkład pola magnetycznego
łuk elektryczny
wyłącznik próżniowy
styk unipolarny
Opis:
The paper presents test results of contacts generating axial magnetic field. The distribution of the magnetic field was measured in a stand enabling investigation of different contact construction. Short-circuit tests were made in a dismountable vacuum chamber on two contact types generating axial magnetic field. The test circuit and the equipment used were described as well as the oscillograms and pictures of the diffusion arc of the interrupted short circuit currents recorded by means of a high speed camera are shown.
Artykuł zawiera opis badań wykonanych w Zakładzie Wielkich Mocy Instytutu Elektrotechniki. Badano dwa rodzaje styków generujących osiowe pole magnetyczne stosowane w komorach wyłączników próżniowych. Badania łuku łączeniowego wykonano rejestrując gaszenie łuku ultraszybką kamerą. W pierwszej części artykułu omówiono budowę stanowiska badawczego. Natomiast w dalszej części przedstawiono wyniki badań oraz oscylogramy i fotogramy zarejestrowane podczas prób zwarciowych w rozbieralnej komorze próżniowej. W konkluzji omówiono uzyskane wyniki badań.
Źródło:
Prace Instytutu Elektrotechniki; 2014, 267; 7-19
0032-6216
Pojawia się w:
Prace Instytutu Elektrotechniki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of ARC in a vacuum chamber with an AMF
Analiza łuku w komorze próżniowej w osiowym polu magnetycznym
Autorzy:
Krasuski, K.
Berowski, P.
Dzierżyński, A.
Hejduk, A.
Kozak, S.
Sibilski, H.
Powiązania:
https://bibliotekanauki.pl/articles/159242.pdf
Data publikacji:
2015
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Elektrotechniki
Tematy:
wyłącznik próżniowy
komora próżniowa
próby zwarciowe
osiowe pole magnetyczne
vacuum circuit breaker (VCB)
vacuum chamber (VCBC)
short circuit test (SCT)
axial magnetic field (AMF)
Opis:
Badania komór próżniowych są wykonywane w celu optymalizacji parametrów wyłączników. Głównym celem jest zmniejszenie wymiarów i zwiększenie zdolności łączeniowej w całym zakresie napięć znamionowych wyłączników. W artykule przedstawiono wyniki obliczeń rozkładu indukcji magnetycznej dla dwu rodzajów styków w dwóch konfiguracjach, tj. styków cewkowych typu ¼ zwoja w położeniu bazowym i po obróceniu styku jednego względem drugiego o 45°, jak i styków cewkowych typu ½ zwoja w położeniu bazowym i po obróceniu styku jednego względem drugiego o 90°. Obliczenia wykazały, że obrót styków względem siebie powoduje zmianę rozkładu indukcji na powierzchniach nakładek stykowych. W przypadku styku cewkowego typu ¼ zwoja indukcja magnetyczna maleje. Powierzchnia, na której wartość indukcji osiąga znaczne wartości również maleje dla tego układu stykowego. W przypadku styku cewkowego typu ½ zwoja obrót styku o 90° powoduje powiększenie powierzchni, na której wartość indukcji przekracza 4 mT/kA. Indukcja bowiem rozłożona jest nierównomiernie na powierzchni nakładki stykowej i jej wartość maleje w kierunku krawędzi styku. Należy stwierdzić, że obrót styku jednego względem drugiego powinno się dobierać każdorazowo dla osiągnięcia największego natężenia pola magnetycznego. W obliczeniach dotyczących styków cewkowych typu ¼ zwoja z odstępem międzystykowym 12 mm, założono, że przewodność w całej przestrzeni międzystykowej jest stała i wynika z napięcia łuku. Przy prądzie 25 kA maksymalna indukcja magnetyczna zmienia się od 180 mT na powierzchni nakładki stykowej do 148 mT w środku odległości pomiędzy stykami. W celu zbadania rozkładu łuku pomiędzy stykami wykonano pomiary dla różnych ich typów w rozbieralnej komorze próżniowej przy prądzie zwarciowym do 15 kA. Rozwój łuku dyfuzyjnego badano przy użyciu kamery do zdjęć szybkich. Zmierzono rozkład osiowego pola magnetycznego dla modeli styków cewkowych typu ¼ zwoja z nakładkami o różnych nacięciach, tj. z nacięciami promieniowymi wykonanymi pod kątem 30° w stosunku do promienia styków, z nacięciami w kształcie łuku, oraz dla styków bez nacięć. Styki z nacięciami wykonanymi pod kątem 30° do promienia styku, miały największe na całej powierzchni styków natężenie pola magnetycznego. Podczas pomiarów styki były zwarte przy pomocy centralnego kołka prze-wodzącego. Jak wynika z obliczeń podczas montażu należy zwrócić uwagę na wzajemne usytuowanie styków, aby zapobiec zmniejszeniu wartości pola magnetycznego. W rozbieralnej komorze próżniowej zbadano rozwój łuku dyfuzyjnego w przestrzeni międzystykowej oraz rozkład stóp łuku na powierzchni styków.
Vacuum circuit breaker chambers (VCBC) are subject of a continuous study to optimize parameters of circuit breakers. The aim is to reduce the size and to increase the breaking ability in the whole range of rated voltages. In optimization attention is paid to reach a uniform distribution of the magnetic field over the contact plate surface. The influence of slits in the contact plates, and the rotation angle between contacts upon the magnetic field distribution (MFD) was analyzed. Field tests of different contact sets were made, using a dismountable vacuum chamber. The tests were conducted at short circuit currents up to 15 kA. A high speed video camera was used to monitor the arc developed between contacts.
Źródło:
Prace Instytutu Elektrotechniki; 2015, 269; 91-99
0032-6216
Pojawia się w:
Prace Instytutu Elektrotechniki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A control method of fault current in MT-HVDC grid based on current limiter and circuit breaker
Autorzy:
Wang, Sihua
Zhao, Lei
Zhou, Lijun
Powiązania:
https://bibliotekanauki.pl/articles/1955197.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
bipolar short circuit
fault current limiting
hybrid DC circuit breaker
ultiterminal HVDC grid
zwarcie bipolarne
ograniczanie prądu zwarciowego
hybrydowy wyłącznik prądu stałego
ultraliniowa sieć HVDC
Opis:
In order to realize selective isolation of fault lines in multi-terminal high voltage DC (MT-HVDC) grids, it is necessary to ensure that the sound lines can still transmit power normally after the grounding fault occurs in a DC power network. If the fault line needs to be cut before the converter is blocked, a DC circuit breaker (DCCB) with large switching capacity is often required. At present, the extreme fault over-current and the high cost of DCCBs have become the prominent contradiction in MT-HVDC projects. Reducing the breaking stress of power electronic devices of the circuit breaker and controlling its cutting-off time are the major difficulties in this research field. In this paper, a topology of a hybrid DCCB with an inductive current limiting device is proposed. By analyzing its working principle, the calculation method of key parameters is given, and a four-terminal HVDC grid is built in a PSCAD/EMTDC platform for fault simulation. The results show that compared with the traditional circuit breaker, this topology can effectively limit the rising speed and maximum current of fault current when the system fails, and quickly remove the fault line, so as to meet the suppression requirement of the HVDC system for fault current.
Źródło:
Archives of Electrical Engineering; 2021, 70, 4; 907-923
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-11 z 11

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies