Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "wastewater system" wg kryterium: Temat


Tytuł:
Analysis and Assesment of the Wastewater Treatment Plant Operation in the City of Kłodzko
Autorzy:
Garbowski, T.
Wiśniewski, J.
Bawiec, A.
Powiązania:
https://bibliotekanauki.pl/articles/125373.pdf
Data publikacji:
2018
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
wastewater treatment system
sewage treatment efficiency
WWTP
treatment plant reliability factor
Opis:
In this study, the current operation efficiency of the wastewater treatment plant (WWTP) in the city of Kłodzko in the Lower Silesia Voivodeship (Poland) was analyzed and the predicted amount of the wastewater flowing to the WWTP in a 20-year period (until the year 2036) was estimated. The data on the quality and the quantity of raw (entering to the WWTP) and treated sewage from the years 2012-2016 were analyzed. The five essential pollutants indicators: biochemical oxygen demand (BOD5), chemical oxygen demand (CODCr), total suspended solids (TSS), total nitrogen and total phosphorus, regulated in the water permit were used to evaluate the efficiency of contaminants removal. On the basis of the percentage reduction of the individual pollutants indicators and their acceptable concentrations in the treated sewage, the effectiveness of the operation of the object was determined. Furthermore, a so-called the treatment plant reliability factor (RF) was calculated and its value below 1.0 indicates the correct operation of the wastewater treatment plant. After determining the prospective amount of raw sewage in 2036 (based on the decreasing population in the city) it has been found that the WWTP will work with a significant reserve of capacity and the modernization of the treatment system, leading to a decrease of its capacity should be considered.
Źródło:
Journal of Ecological Engineering; 2018, 19, 2; 114-124
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The influence of hydraulic loading on biofilm properties in a subsurface wastewater infiltration system
Autorzy:
Zhang, L.
Yang, J.
Powiązania:
https://bibliotekanauki.pl/articles/205392.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
subsurface wastewater infiltration system
biofilms
hydraulic loading
spatial distribution
biofilm properties
Opis:
In this study, a pilot-scale subsurface wastewater infiltration system (SWIS) was deployed to study landscape water treatment. The goal of the study was to investigate the effects of hydraulic loading on pollutant removal and the spatial distribution of biofilm properties in SWIS. Results showed that the efficiencies of chemical oxygen demand (COD), total nitrogen (TN) and total phosphorus (TP) removal degraded as hydraulic loading increased. Furthermore, quantities of the biofilm properties parameter s increased with the hydraulic loading. Polysaccharide and protein levels ranged from 560 to 1110 μg/g filler and 60 to 190 μg/g filler, respectively, at a hydraulic loading of 0.2 m/d. At a hydraulic loading of 0.4 m/d, the quantities of polysaccharide and protein ranged from 1200 to 3300 μg/g filler and 80 to 290 μg/g filler, respectively. Biofilm intensity and biofilm activity per unit weight decreased with the increase in hydraulic loading.
Źródło:
Archives of Environmental Protection; 2016, 42, 4; 70-79
2083-4772
2083-4810
Pojawia się w:
Archives of Environmental Protection
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Microbial communities and relationship with biofilm spatial distributions in subsurface wastewater infiltration systems
Autorzy:
Zhang, L.
Yang, J.
Powiązania:
https://bibliotekanauki.pl/articles/207883.pdf
Data publikacji:
2016
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
water treatment
wastewater infiltration system
DGGE
volatile suspended solids
oczyszczanie ścieków oczyszczanie wody
systemy infiltracji ścieków
lotne zawiesiny
Opis:
A pilot-scale subsurface wastewater infiltration system (SWIS) was designed for the treatment of polluted river water. The components of microbial communities have been identified and characterized and their dependences on some indicators of biofilm formation in the SWIS have been determined. The average efficiencies of COD, TN and removal were 43.3%, 28.8% and 79.6%, respectively. According to the denaturing gradient gel electrophoresis (DGGE) profile, high intensity and uniform bands were generated, indicating an abundant microbial community in each layer of the SWIS. Furthermore, the Shannon index analysis showed high correlation to the spatial distribution of microbial communities as well as the quantity of biofilm in each sample, which were characterized by measuring volatile suspended solids (VSS), phospholipids, proteins and polysaccharides. Sequencing of partial 16S rRNA gene fragments revealed that the composition of the total bacterial communities was dominated by Alphaproteobacteria, Gammaproteobacteria, Deltaproteobacteria, Pseudomonas, Bacillus, Flavobacteriaceae, TM-7, and other uncultured bacteria. These bacteria may contribute to nutrient removal in SWIS. +4 NH –N
Źródło:
Environment Protection Engineering; 2016, 42, 3; 55-69
0324-8828
Pojawia się w:
Environment Protection Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Sorption of organic compounds by organo-zeolites
Autorzy:
Wołowiec, M.
Muir, B.
Bajda, T.
Powiązania:
https://bibliotekanauki.pl/articles/184432.pdf
Data publikacji:
2016
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
water system
human health
wastewater
Opis:
Organic compounds such as BTEX and PAHs are one of the most common contaminants in water system. These contaminants would take decades to degrade and they have harmful effects on human health (Qin et al. 2008). Several treatment methods have been developed to remove those contaminants from industrial wastewater. They include ion-exchange, filtration, adsorption and the use of various types of sorbents for example zeolites (Kibazohi et al. 2004, Mathur et al. 2007, Aivaliotiet al. 2012, Almeida et al. 2012). Natural clinoptilolite (Cp) from the Bystré deposit in Slovakia and zeolite Na-X synthesized from fly ash has been modified with a hexadecyltrimethyl ammonium bromide (HDTMA) in amounts of 1.0 and 2.0 of external cation exchange capacity (ECEC) of the zeolites (Szala et al. 2013). The sorption properties of unmodified zeolites and organo-zeolites in terms of aqueous solutions of benzene, ethylobenzene, toluene, p-xylene (BTEX) and their mixtures as well as anthracene, naphthalene, benzo[a]pyrene, dibenzo[a,h]anthracene (PAHs) and their mixtures at different concentrations were evaluated. The results showed that the modification of the zeolite Na-X and Cp with HDTMA improves the sorption properties. Modification in the amount of 1.0 ECEC proved to be the best in terms of p-xylene, anthracene, naphthalene, benzo[a]pyrene, dibenzo[a,h]anthracene. On the other hand benzene, ethylobenzene and toluene were adsorbed the most effectively by 2.0 ECEC modification of Na-X and Cp. Based on experimental data, the removal efficiencies for BTEX follows the order: p-xylene > toluene > benzene > ethylobenzene, for POHs: dibenzo[a,h]anthracene > benzo[a] pyrene > anthracene > naphthalene. P-xylene and naphtalene were adsorbed in the greatest quantity and benzene and anthracene in the lowest quantity from the mixtures of BTEX and PAHs, respectively. The sorption efficiency depends on the physicochemical properties of the organic compounds (dipole moment, molar mass, molecule structure and the time of the sorption process) as well as natural Cp and synthetic zeolite Na-X properties, such as Si/Al ratio, texture parameters and external cation exchange capacity. With an increasing concentration of the hydrocarbons in the solution the sorption capacity increases (Szala et al. 2015). Natural Cp is a better sorbent than synthetic zeolite Na-X in case of BTEX sorption, while PAHs are adsorbed more effectively by zeolite Na-X and its modifications. The mechanism of the sorption consists on the dissolving of the organic compounds into the organic layer of the surfactant (on the zeolites’ surface) as well as on the organic compounds’ penetration into the mesopores.
Źródło:
Geology, Geophysics and Environment; 2016, 42, 1; 139-140
2299-8004
2353-0790
Pojawia się w:
Geology, Geophysics and Environment
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Innovative system of simultaneous transportation and treatment of sanitary wastewater in scattered dwelling areas
Autorzy:
Duda, A.
Szulżyk-Cieplak, J.
Lenik, K.
Powiązania:
https://bibliotekanauki.pl/articles/123239.pdf
Data publikacji:
2016
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
innovative system
transportation wastewater
reatment wastewater
small-bore sewerage
Opis:
The work presented the possibility of implementing an innovative system of simultaneous transportation and treatment of sanitary wastewater in scattered dwelling areas. Small-bore sewerage with a balanced flow enables simple and inexpensive simultaneous disposal and pre-treatment of fluid with from vast, undeveloped areas.
Źródło:
Journal of Ecological Engineering; 2016, 17, 5; 84-89
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of the Proportion of Incidental Water in Annual Wastewater Inflows to a Selected Treatment Plant During a 15-year Observation Period
Autorzy:
Kaczor, Grzegorz
Cupak, Agnieszka
Powiązania:
https://bibliotekanauki.pl/articles/1955390.pdf
Data publikacji:
2021
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
sewerage system
wastewater
incidental water
Opis:
The main aim of the study was to determine whether the amount and share of incidental water in wastewater inflows to the wastewater treatment plant increased with the age and development of the sewage system. The object of the study is a small sewerage system located in southern Poland, in the Lesser Poland Province, 15 km northeast of the Kraków city. The analysis of a 15-year observation series of daily wastewater flows, from 01.01.1994 to 31.12.2018, allowed a reliable assessment of the actions taken by the sewage system operator to reduce the sources of incidental water inflow to the sewage network. The study showed that the percentage share of incidental waters in the annual wastewater inflow to the analysed treatment plant decreased from 35.9% in 2004 to 8.4% in 2018. This reduction should be treated as a success of the remedial actions of the sewage system operator. However, the study showed at the same time that in 2017 alone, 56 709 m3 of incidental water flowed into the analysed sewerage system, compared to 166 075 m3 of wastewater. A similar case was repeated in 2013, when 53 060 m3 of incidental water and 132 860 m3 of real wastewater flowed into the treatment plant. These cases show that all remedial measures by the network operator are still insufficient when heavy precipitation occurs in a given year for a long period of time.
Źródło:
Journal of Ecological Engineering; 2021, 22, 7; 204-211
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Providing of resource saving in Danube rice irrigation systems based on reuse of drainage water and wastewater
Oszczędzanie zasobów w systemach nawadniania pól ryżowych w dolinie Dunaju wynikające z ponownego wykorzystania wody drenażowej i ścieków
Autorzy:
Rokochynskiy, A.
Turcheniuk, V.
Volk, P.
Prykhodko, N.
Frolenkova, N.
Powiązania:
https://bibliotekanauki.pl/articles/2083877.pdf
Data publikacji:
2020
Wydawca:
Szkoła Główna Gospodarstwa Wiejskiego w Warszawie. Wydawnictwo Szkoły Głównej Gospodarstwa Wiejskiego w Warszawie
Tematy:
drainage water
wastewater
rice irrigation system
reuse
Opis:
Questions of reuse of drainage water and wastewater of rice systems on the example of rice irrigation systems are determined. The technological scheme, which saves water and energy resources during the irrigation of crops in the rice system, is proposed. Calculations of economic efficiency of water circulation technology in the Danube rice irrigation systems (RIS) with drainage water and wastewater (DWW) dilution with fresh water in the ratio of 1 : 1 showed that the net profit will amount to UAH 26,266.5 per 1 ha, while the dilution in the ratio of 1 : 2 – to UAH 26,161.5 per 1 ha. Complementary net profit will accordingly amount to UAH 1,337.8 and 1,231.5 per 1 ha. The most perspective technique to use DWW in rice irrigation systems is their reuse with dilution with fresh water at a ratio of 1 : 1 or 1 : 2. This ratio corresponds to most indicators for which was done an evaluation of water that is supplied for irrigation. Also this ratio does not lead to deterioration of soil salt regime.
Źródło:
Acta Scientiarum Polonorum. Architectura; 2020, 19, 1; 43-48
1644-0633
Pojawia się w:
Acta Scientiarum Polonorum. Architectura
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Chronopotentiometric and chronoamperometric electrocoagulation of wastewater in a static system
Statyczna elektrokoagulacja ścieków modelowych
Autorzy:
Smoczyński, L.
Zaborowska-Piworowicz, A.A.
Wardzyńska, R.
Załęska-Chróst, B.
Dłużyńska, K.T.
Powiązania:
https://bibliotekanauki.pl/articles/388537.pdf
Data publikacji:
2009
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
elektrokoagulacja
system statyczny
ścieki modelowe
electrocoagulation
chronopotentiometr
chronoamperometr
static system
model wastewater
Opis:
This study presents the results of electrochemical treatment of model wastewater. It compares the parameters and the results of wastewater electrolysis performed by chronopotentiometric electrocoagulation (CHRP) at constant current intensity (I = const) and chronoamperometric electrocoagulation (CHRA) at constant voltage (U = const). Electrolysis was carried out in a static system with the use of an electrolyzer with aluminum electrodes. A six-electrode electrolyzer (three cathodes and three anodes) was applied. The chemical oxygen demand (COD), turbidity, color intensity, suspended solids and total phosphorus concentration of the solution were determined after electrocoagulation and sludge sedimentation.
Przedstawiono wyniki elektrochemicznego oczyszczania ścieków modelowych. Porównano parametry oraz efekty elektrolitycznego oczyszczania ścieków w warunkach chronopotencjometrycznych (CHRP), tj. przy stałym natężeniu prądu (I = const) oraz chronoamperometrycznych (CHRA), tj. przy stałym napięciu (U = const). Elektrolizę prowadzono w układzie statycznym z użyciem elektrolizera z elektrodami glinowymi. Zastosowano 6-eIektrodowy (3 katody i 3 anody) elektrolizer. Po elektrokoagulacji i sedymentacji osadu w roztworze oznaczano chemiczne zapotrzebowanie na tlen ChZT, mętność, barwę, zawiesiny oraz stężenie fosforu ogólnego.
Źródło:
Ecological Chemistry and Engineering. A; 2009, 16, 3; 231-238
1898-6188
2084-4530
Pojawia się w:
Ecological Chemistry and Engineering. A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Status of the Water Supply and Sanitation Infrastructure in the Kraśnik County
Autorzy:
Gizińska-Górna, Magdalena
Gawron, Mariusz
Powiązania:
https://bibliotekanauki.pl/articles/123147.pdf
Data publikacji:
2020
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
sanitation infrastructure
commune
water supply system
sewerage system
wastewater treatment plant
cesspool
Opis:
The paper describes the status of water supply and sanitation infrastructure in the Kraśnik County. The description is based on the official statistical data and the data obtained in a survey carried out in 2016. The Kraśnik County is located in the Lublin Province and comprises 10 communes: one urban commune (the Municipality of Kraśnik), two urban-rural communes (Annopol and Urzędów), and seven rural communes (Dzierzkowice, Gościeradów, Kraśnik, Szastarka, Trzydnik Duży, Wilkołaz, and Zakrzówek). In 2016, an average of 90.9% of the County’s inhabitants had the access to the mains water, but only 13.5% were connected to the mains sewerage. The County has six centralized wastewater treatment plants with a total capacity of approximately 14.164 m3/d. The survey data showed that the records of cesspools were kept in only four of the County’s communes: the Municipality of Kraśnik, Urzędów, Wilkołaz, and Zakrzówek. The total number of cesspools in those communes was 4776. The Kraśnik County is in great demand for the construction of on-site domestic wastewater treatment plants, which are an excellent alternative to cesspools. The network of domestic wastewater treatment plants in the Kraśnik County is made up almost entirely of systems with a drainfield, which may pose a serious threat to the soil and water environment. The results of the present study suggest that Commune Offices must take decisive steps to eliminate the existing disproportion between the coverages of the sewerage and water supply systems in the County’s communes.
Źródło:
Journal of Ecological Engineering; 2020, 21, 4; 168-177
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The efficiency of filtration materials (Polonite® and Leca®) supporting phosphorus removal in on site treatment systems with wastewater infiltration
Autorzy:
Karczmarczyk, A.
Woja, K.
Bliska, P.
Baryła, A.
Bus, A.
Powiązania:
https://bibliotekanauki.pl/articles/101107.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Stowarzyszenie Infrastruktura i Ekologia Terenów Wiejskich PAN
Tematy:
phosphorus
reactive material
on site wastewater treatment
infiltration system
Opis:
The most of the on site wastewater treatment systems in Poland discharges treated effluent to the soil. The goal of phosphorus (P) reduction from dispersed sources of pollution can be achieved by application of P reactive materials in the construction of wastewater infiltration systems. Two P reactive materials were tested in this study: Polonite® in grains of 2÷6 mm and lightweight aggregate Leca® in grains of 4÷10 mm. Apparent P sorption capacity was assesed on 40.9 mg·g-1 (Polonite®) and 5.1 mg·g-1 (Leca®). Both materials sorbed P-PO4 very fast, after 15 min over 90% of P was removed from solution and wastwater. Wastewater used in this study came from the outlet from the septic tank of on site septic system. P-PO4 solution was prepared from KH2 PO4 and the tap water. In the small column experiment, four collumns (2 filled with Polonite® and 2 filled with Leca®) were fed with wastewater and P-PO4 solution in hydraulic loadings of 30÷40 dm3 ·m-2·d-1. All the columns removed significant amounts of P from both solution and wastewater with the reduction between 28.3% and 72.5%. The mean P-PO4 effluent concentrations ranged from 1.21 mg·dm-3 to 7.12 mg·dm-3. The best overall performance was achieved by the Polonite® fed with solution. Both tested materials can support wastewater treatment in on site systems.
Źródło:
Infrastruktura i Ekologia Terenów Wiejskich; 2017, IV/1; 1401-1413
1732-5587
Pojawia się w:
Infrastruktura i Ekologia Terenów Wiejskich
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Application of the BIOLOG system for characterization of Serratia marcescens ss marcescens isolated from onsite wastewater technology (OSWT)
Autorzy:
Chojniak, Joanna
Jałowiecki, Łukasz
Dorgeloh, Elmar
Hegedusova, Berta
Ejhed, Helene
Magnér, Jörgen
Płaza, Grażyna
Powiązania:
https://bibliotekanauki.pl/articles/1038922.pdf
Data publikacji:
2015
Wydawca:
Polskie Towarzystwo Biochemiczne
Tematy:
onsite wastewater treatment
Biolog system
Serratia spp.
antibiotic resistance
Opis:
The scope of this study was to apply the Biolog system to identify and characterize a Serratia strain isolated from the surface of black plastic pieces which constitute the fluidized bed filter (onsite wastewater technology, OSWT). The preliminary isolation of the strain was done in the medium with tetracycline at a 16 mg/l concentration. To characterize the isolated strain, the following Biolog methods were applied: (1) EcoPlates microplates for evaluation of physiological profiling, (2) GEN III OmniLog® ID System for identification of the isolate, and (3) phenotypic microarrays (PM) technology for evaluation of sensitivity to antibiotics (PM11 and PM12). Results were recorded using the original OmniLog® software. The Serratia strain was identified as Serratia marcescens ss marcescens with similarity index 0.569. The same identification was obtained by the 16S rDNA analysis. PM analysis showed an enhancement of phenotype (resistance or growth) of this strain to 35 antibiotics. The loss of phenotype (sensitivity or non-growth) was observed only for 5 antibiotics: lomefloxacin (0.4 µg/ml), enoxacin (0.9 µg/ml), nalidixic acid (18.0 µg/ml), paromomycin (25.0 µg/ml) and novobiocin (1100 µg/ml). This study acknowledges that the methods proposed by the Biolog system allow correct and complete identification and characterization of the microbes isolated from different environments. Phenotypic microarrays could be successfully used as a new tool for identification of the multi-antibiotic resistance of bacteria and for determination of the minimal inhibition concentrations (MIC).
Źródło:
Acta Biochimica Polonica; 2015, 62, 4; 799-805
0001-527X
Pojawia się w:
Acta Biochimica Polonica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Condition of the Sanitary Infrastructure in the Ryki District in Poland and the Need for its Development
Autorzy:
Jóźwiakowska, Karolina
Micek, Agnieszka
Kanios, Krzysztof
Powiązania:
https://bibliotekanauki.pl/articles/1839635.pdf
Data publikacji:
2021
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
district
septic tank
household wastewater treatment plants
collective wastewater treatment plants
water supply network
sewage system
Opis:
The aim of this paper was to present the current state and the need for development of the sanitary infrastructure in the communes of the Ryki District located in the Lublin Voivodeship. The Ryki District encompasses 1 urban Commune – Dęblin, 1 urban-rural Commune – Ryki and 4 rural communes: Kłoczew, Nowodwór, Stężyca and Ułęż. The paper is based on the data from the surveys conducted in all the afore-mentioned communes in 2016. In the whole district on average 71.3% of the population used the water supply network, while 42% of the inhabitants were able to discharge wastewater to the sewage system. Within the area of the Ryki District, 5 collective wastewater treatment plants with a capacity exceeding 5 m3/d functioned in 2016. The households which were not connected to the sewage network discharged wastewater mainly to non-return tanks. About 440 household sewage treatment plants were found in the surveyed communes. The overwhelming majority of such small objects in the discussed district were activated sludge systems (92%). The research carried out in 2016 proved a strong need to develop the current state of the sanitary infrastructure in the Ryki District. A particular emphasis should be placed on the wastewater management by connecting the inhabitants of urban areas to a joint sewage disposal system. Ecological awareness must be raised so as to encourage people to invest in household wastewater treatment plants, which should be used in the areas with scattered development.
Źródło:
Journal of Ecological Engineering; 2021, 22, 4; 256-264
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Condition of the Sanitary Infrastructure in the Bialski District in Poland and the Need for its Development
Autorzy:
Jóźwiakowska, Karolina
Marzec, Michał
Powiązania:
https://bibliotekanauki.pl/articles/124925.pdf
Data publikacji:
2020
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
district
septic tank
household wastewater treatment plants
collective wastewater treatment plants
water supply network
sewerage system
Opis:
The aim of this paper was to present the current state and the need for development of the sanitary infrastructure in the communes of the Bialski District located in the Lublin Voivodeship. The Bialski District encompasses 2 urban communes: Miedzyrzec Podlaski and Terespol and 17 rural communes: Biała Podlaska, Drelów, Janów Podlaski, Kodeń, Konstantynów, Leśna Podlaska, Łomazy, Międzyrzec Podlaski, Piszcząc, Rokitno, Rossosz, Sławatycze, Sosnówka, Terespol, Tuczna, Wisznice and Zalesie. The present paper uses the data from the surveys conducted in these communes in 2016. On average, 79.2% of the population used the water supply system in the surveyed communes, while 39.4% of the inhabitants had the possibility of discharging wastewater to the sewerage system. In the area of the communes, there were 20 collective, mechanical and biological wastewater treatment plants with a capacity exceeding 5 m3/d. The households which were not connected to the wastewater network, discharged wastewater mainly to non-return tanks. In the surveyed communes, there were 4437 household wastewater treatment plants. Most of them (above 80%) were the systems with infiltration drainage, which do not ensure high efficiency of pollutants removal and may even contribute to the degradation of the groundwater quality. In order to solve the existing problems of wastewater and water management occurring in the communes where the Bialski District is located, it is necessary to further develop collective wastewater systems and equip the areas characterized by dispersed housing with highly efficient household treatment plants, e.g. constructed wetlands.
Źródło:
Journal of Ecological Engineering; 2020, 21, 5; 155-163
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Variable dynamics of sewage supply to wastewater treatment plant depending on the amount of precipitation water inflowing to sewerage network
Zmienność dynamiki dopływu ścieków do oczyszczalni w aspekcie przedostawania się wód opadowych do systemu kanalizacyjnego
Autorzy:
Bugajski, P. M.
Kaczor, G.
Chmielowski, K.
Powiązania:
https://bibliotekanauki.pl/articles/292612.pdf
Data publikacji:
2017
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
precipitation
precipitation water
sewerage system
wastewater
opad atmosferyczny
system kanalizacyjny
ścieki
wody opadowe
Opis:
The paper analyzes the effect of precipitation water that inflowing to sanitary sewage system as accidental water on the changes in the total amount of treated sewage. The effects of accidental water supply on the total amount of sewage inflowing to treatment plant were analyzed based on mean daily amounts from the investigated periods and mean daily amounts from incidental supplies. The study was conducted in the years 2010–2015. Six characteristic research periods were identified (one per each calendar year), when the amount of sewage in the sanitary sewage system was greater than during dry weather. The analysis of changes in the amount of sewage supplied to the sewerage system in the six investigated periods revealed that the accidental water constituted from 26.8% to 48.4% of total sewage inflowing to the wastewater treatment plant (WWTP). In exceptional situations, during intense rains, the share of precipitation water in the sewerage system would increase up to 75%. Then, the rainwater inflowing the sewerage system caused hydraulic overloading of the WWTP by exceeding its maximum design supply.
W artykule przedstawiono analizę dotyczącą wpływu wielkości opadów atmosferycznych, które trafiają do kanalizacji sanitarnej jako wody przypadkowe, na zmienność ilości ścieków poddawanych procesom oczyszczania. Analizą dotyczącą wpływu wód przypadkowych na ilość ścieków dopływających do oczyszczalni objęto wartości średnie dobowe z badanych okresów oraz średnie dobowe dopływy ścieków z przypadków incydentalnych. Badania prowadzono w okresie od 2010 do 2015 roku, w którym wyróżniono 6 charakterystycznych okresów badawczych po jednym w każdym roku kalendarzowym, w których stwierdzono zwiększoną ilość ścieków w kanalizacji sanitarnej w porównaniu z ilością ścieków w kanalizacji w okresie pogody bezdeszczowej. W wyniku przeprowadzonej analizy dotyczącej zmienności ilości ścieków w kanalizacji w 6 okresach badawczych stwierdzono, że udział wód przypadkowych stanowił od 26,8 do 48,4% ogólnej ilości ścieków dopływających do oczyszczalni, natomiast w przypadkach incydentalnych w warunkach intensywnych opadów atmosferycznych udział wód opadowych w ogólnej ilości ścieków w systemie kanalizacyjnym wzrastał do 75%. W okresie badań w incydentalnych przypadkach wody opadowe przedostające się do kanalizacji powodowały przeciążenia hydrauliczne obiektu ponad dopływ maksymalny, na jaki została zaprojektowana oczyszczalnia.
Źródło:
Journal of Water and Land Development; 2017, 33; 57-63
1429-7426
2083-4535
Pojawia się w:
Journal of Water and Land Development
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Condition of Sanitary Infrastructure in the Parczew District and the Need for its Development
Autorzy:
Micek, A.
Marzec, M.
Jóźwiakowska, K.
Pochwatka, P.
Powiązania:
https://bibliotekanauki.pl/articles/123430.pdf
Data publikacji:
2018
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
sanitary infrastructure
commune
water supply system
sewerage system
wastewater treatment plant
septic tank
Opis:
The aim of this paper is to present the current state and the need for development of sanitary infrastructure in the communes of Parczew District, in Lublin Voivodeship. Parczew District encompasses seven communes: Parczew, Dębowa Kłoda, Jabłoń, Milanów, Podedwórze, Siemień, and Sosnowica. The present paper uses the data from the surveys conducted in these communes in 2016. On average, 88% of the population used the water supply system in the communes surveyed, while 48% of the inhabitants were connected to a sewerage system. Parczew District had 12 collective mechanical and biological wastewater treatment plants with a capacity exceeding 5 m3/d. The households which were not connected to the sewerage network discharged the wastewater mainly to non-return tanks. In the communes surveyed, 1,115 households had domestic wastewater treatment plants. All of them were systems with infiltration drainage, which do not ensure high efficiency of removing pollutions and may even contribute to the degradation of the groundwater quality. In order to solve the existing problems of sewage and water management in the communes of Parczew District, it is necessary to further develop the collective sewerage systems and equip the areas which have a dispersed development layout with highly efficient domestic treatment plants, such as constructed wetlands.
Źródło:
Journal of Ecological Engineering; 2018, 19, 5; 107-115
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies