Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "ventilation rate" wg kryterium: Temat


Wyświetlanie 1-3 z 3
Tytuł:
Period verification device for ventilation rate standard rods based on a digital thermal flowmeter
Autorzy:
Hu, Jiacheng
Sha, Ying
Cai, Jinhui
Liu, Ying
Liu, Suijun
Powiązania:
https://bibliotekanauki.pl/articles/2052108.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
ventilation rate standard rod
period verification
numerical simulation
digital thermal flowmeter
micro-pressure difference adjustment
Opis:
Ventilation rate is a physical index that is strictly controlled during cigarette manufacturing because an abnormal ventilation rate can affect the release of mainstream smoke, tar, and other components harmful to human health. Therefore, the standard rod is used for measuring the ventilation rate, which necessitates accurate and effective periodic inspections. In this study, we designed and built a set of special tobacco ventilation rate standard rods to assess the standard device during its verification period and used a digital thermal flowmeter as the flow standard.We determined the micro-pressure adjustment interval through fluid simulation, and conducted an experimental verification based on the simulation results. At the adjustment point where the differential pressure value was 0 Pa, the period verification device was tested under the standard values of 27.38%, 58.83%, and 71.95%. The results show that the measurement errors of the device are -0.42%, 0.55%, and -0.13% respectively, which all meet the verification regulation requirements and indicate that the device is applicable in practical situations.
Źródło:
Metrology and Measurement Systems; 2022, 29, 1; 231-244
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Experimental Equipment for Investigation of Soybean Storage with Active Ventilation
Autorzy:
Duisenova, Sholpan
Atykhanov, Aibek
Karaivanov, Dimitar
Kassymbayev, Bekbossyn
Kalym, Kabdyrakhim
Sagyndikova, Aigul
Powiązania:
https://bibliotekanauki.pl/articles/125394.pdf
Data publikacji:
2020
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
active ventilation
air flow velocity
conveying height
flow rate
power consumption
productivity
Opis:
The article investigates and substantiates the operating modes of a container-modular equipment with active ventilation, such as specified (real) productivity, power consumption of the conveying process, as well as the use of a progressive method of controlling the humidity and temperature in soybean storage volume. Experimental equipment is developed which adequately simulates the proposed technology for soybean storage with active ventilation for the calculated data verification. The experiments confirm that the proposed experimental equipment makes it possible to adequately simulate the process of soybean storage with active ventilation and conduct experiments with the regulation of basic parameters such as productivity, power consumption, humidity, etc. using modern methods, devices and digital technologies. Experimental results are presented. Along with this, using the “Strazh Klimat” software, humidity and temperature are monitored during the experiments. Experimental data are obtained by the use of which it is possible to establish the dependence of the conveying height on the air flow velocity.
Źródło:
Journal of Ecological Engineering; 2020, 21, 3; 117-127
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Investigation on fire potential of ventilation ducts
Autorzy:
Jha, Ankit
Amar, Vinod
Tukkaraja, Purushotham
Powiązania:
https://bibliotekanauki.pl/articles/1839004.pdf
Data publikacji:
2019
Wydawca:
Główny Instytut Górnictwa
Tematy:
auxiliary ventilation
heat release rate
emission factor
differential scanning calorimetry
thermogravimetric analysis
wentylacja pomocnicza
szybkość wydzielania ciepła
współczynnik emisji
różnicowa kalorymetria skaningowa
analiza termograwimetryczna
Opis:
Fires in underground mines can create dangerous conditions for personnel and cause severe damage to property. Because of the confined nature of the underground environment, these effects can escalate rapidly. In underground mines, air ducts/bags are used for ventilating narrow blind headings; these consist of combustible materials that have not been investigated thoroughly in terms of their fire potential and gas emissions. The primary objective of this study is to investigate the fire potential and emission factors for these ducts. A preliminary investigation was performed using differential scanning calorimetry and thermogravimetric analysis. These tests provide crucial information for duct samples including the melting point which is used for designing a novel experimental setup for combustion analysis. This setup was used to perform a combustion experiment at 350 °C, so that all specimens can achieve complete combustion. Furthermore, the heat release rate and emission factors were calculated; it was observed that heat release rate for all the specimens was identical because of similar oxygen consumption during the experiment. Sample B has the lowest emission factor among the four samples (A, B, C, D) tested in this study.
Źródło:
Journal of Sustainable Mining; 2019, 18, 4; 270-276
2300-1364
2300-3960
Pojawia się w:
Journal of Sustainable Mining
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-3 z 3

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies