Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "uzdatnianie" wg kryterium: Temat


Tytuł:
Optimizing coagulant choice for treatment technology of surface water for human consumption
Autorzy:
Wolska, M.
Mołczan, M.
Urbańska-Kozłowska, H.
Solipiwko-Pieścik, A.
Powiązania:
https://bibliotekanauki.pl/articles/208212.pdf
Data publikacji:
2018
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
surface treatment
water treatment
coagulation
uzdatnianie wody
koagulacja
uzdatnianie powierzchni
Opis:
Coagulation is a process commonly used in water treatment, especially for surface water. This process aims to effectively remove organic matter [1, 2] especially precursors of oxidation and disinfection by-products [3–5], whose creation potential is related to absorption values at 254 nm (UV254) [6] Due to a very large variability in surface water composition over the course of the year and different contamination levels dependent on water source location, it is important to optimally choose coagulant type and dosage. Such optimization is difficult due to the presence of a large number of coagulants on the market. Świderska-Bróż and Rak [7] and Lee et al. [8] have shown that prehydrolyzed coagulants are less sensitive to changes in temperature and pH of the input water than classic ones. Lin et al. [9] suggest however that the effectiveness of coagulation mainly depends on the type and structure of organic matters present in waters, and to a much lesser degree on pH and temperature.
Źródło:
Environment Protection Engineering; 2018, 44, 4; 131-141
0324-8828
Pojawia się w:
Environment Protection Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Improvement of the ferritisation method for removal of nickel compounds from wastewater
Autorzy:
Kochetov, G.
Samchenko, D.
Naumenko, I.
Powiązania:
https://bibliotekanauki.pl/articles/403005.pdf
Data publikacji:
2014
Wydawca:
Politechnika Białostocka. Oficyna Wydawnicza Politechniki Białostockiej
Tematy:
water
treatment
electromagnetic treatment
ferritisation
nickel
woda
uzdatnianie
uzdatnianie elektromagnetyczne
użyźnianie
nikiel
Opis:
A process for comprehensive treatment of wastewater flows of electroplating facilities was developed with ferritisation-based removal of nickel compounds. Effects of ratios of heavy metals concentrations and pulse electromagnetic discharges on ferritisation-based treatment of nickel-containing wastewater were studied. The treatment sediments were analysed by qualitative and quantitative phase analysis. Application of electromagnetic wastewater treatment for low-temperature ferritisation was proved to be economically viable.
Źródło:
Budownictwo i Inżynieria Środowiska; 2014, 5, 4; 143-148
2081-3279
Pojawia się w:
Budownictwo i Inżynieria Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A robust generalized sidelobe canceller employing speech leakage masking
Skuteczny tłumik listków bocznych z wykorzystaniem maskowania przecieku mowy
Autorzy:
Borowicz, A.
Powiązania:
https://bibliotekanauki.pl/articles/88400.pdf
Data publikacji:
2014
Wydawca:
Politechnika Białostocka. Oficyna Wydawnicza Politechniki Białostockiej
Tematy:
GSC
psychoakustyka
uzdatnianie mowy
psychoacoustics
speech enhancement
Opis:
A novel speech enhancement method based on generalized sidelobe canceller (GSC) structure is presented. We show that it is possible to reduce audible speech distortions and preserve residual noise level under acoustic model uncertainties. It can be done by constraining a speech leakage power according to masking phenomena and conditional minimizing the residual noise power. We implemented the proposed approach using a simple delay-and-sum beamformer model. Finally a comparative evaluation of the selected methods is performed using objective speech quality measures. The results show that the novel method outperforms conventional one providing lower speech distortions.
Prezentowana jest nowa metoda uzdatniania mowy w oparciu o strukturę uogólnionego tłumika listków bocznych. Wykazujemy, ze możliwe jest zmniejszenie słyszalnych zniekształceń mowy przy zachowaniu stałego poziomu szumu rezydualnego, dla modeli przybliżonych środowiska akustycznego. Może to być dokonane poprzez uwarunkowanie poziomu mocy przecieku mowy zgodnie ze zjawiskiem maskowania oraz minimalizację warunkową mocy szumu rezydualnego. Proponowane podejście zaimplementowano w oparciu o prosty model beamformera opóźniająco-sumującego. Ostatecznie przeprowadzono ocenę porównawczą wybranych metod z wykorzystaniem obiektywnych miar jakości mowy. Wyniki pokazują, że nowa metoda przewyższa konwencjonalną zapewniając mniejsze zniekształcenia mowy.
Źródło:
Advances in Computer Science Research; 2014, 11; 17-29
2300-715X
Pojawia się w:
Advances in Computer Science Research
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Efficiency analysis of an automatic water treatment system
Analiza skuteczności działania automatycznego systemu uzdatniania wody
Autorzy:
Tomasik, M.
Juszka, H.
Lis, S.
Powiązania:
https://bibliotekanauki.pl/articles/286277.pdf
Data publikacji:
2012
Wydawca:
Polskie Towarzystwo Inżynierii Rolniczej
Tematy:
sterowanie automatyczne
uzdatnianie wody
automatic control
water treatment
Opis:
The paper presents efficiency analysis of the water treatment controlling system. Introduction sets forth issues concerning this process, various options of its realization depending on the water origin and purpose of its use. Measures were taken within experimental research in the water treatment station and it included: measures of the size of water uptake in pH function, chlorine content and absolute conductivity. Then, correlations between particular examined parameters were determined and necessity of including them in the automatic control process was indicated. Mathematical models in the form of regression equations, which enable optimal performance of the water treatment process were developed.
Przedstawiono analizę skuteczności systemu sterowania procesem uzdatniania wody. We wstępie wskazano na problematykę tego procesu, przedstawiono różne warianty jego realizacji w zależności od pochodzenia i przeznaczenia wody. W ramach badań doświadczalnych wykonano pomiary w stacji uzdatniania wody, na które składały się pomiary: wielkości poboru wody w funkcji pH, zawartości chloru, przewodności bezwzględnej. Następnie określono korelacje pomiędzy poszczególnymi badanymi parametrami i wskazano konieczność uwzględnienia ich w procesie automatycznego sterowania. Na podstawie analizy opracowano modele matematyczne w formie równań regresji, umożliwiające optymalne prowadzenie procesu uzdatniania wody.
Źródło:
Inżynieria Rolnicza; 2012, R. 16, nr 4, t. 2, 4, t. 2; 165-173
1429-7264
Pojawia się w:
Inżynieria Rolnicza
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ultrafiltration as a method of natural organic matter separation from water
Ultrafiltracja jako metoda usuwania naturalnych substancji organicznych z wody
Autorzy:
Kabsch-Korbutowicz, M.
Powiązania:
https://bibliotekanauki.pl/articles/1825951.pdf
Data publikacji:
2008
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
ultrafiltracja
oczyszczanie wody
uzdatnianie wody
membrany ultrafiltracyjne
wydajność hydrauliczna membran
Opis:
Pogarszająca się jakość wód oraz rosnące wymagania stawiane wodzie przeznaczonej do spożycia przez ludzi powodują konieczność stosowania nowoczesnych procesów technologicznych ich uzdatniania. Taką techniką jest ultrafiltracja, proces membranowy pozwalający na usunięcie bardzo szerokiego spektrum zanieczyszczeń: zarówno mikroorganizmów jak i makrocząsteczek o wielkości 1 -100 nm. Do tej grupy zanieczyszczeń należą naturalne substancje organiczne, które zarówno niekorzystnie wpływają na jakość wody jak i na wydajność hydrauliczną membran poprzez ich blokowanie (fouling). O skuteczności usuwania naturalnych substancji organicznych z wody w procesie ultrafiltracji oraz podatności membran na blokowanie decyduje bardzo wiele czynników związanych zarówno z właściwościami membran jak i składem oczyszczanej wody. Celem przeprowadzonych badań było określenie wpływu właściwości membran ultrafiltracyjnych; tj. ich granicznej masy molowej (cut-off) oraz polimeru z którego wykonane zostały membrany, jak również właściwości roztworu poddawanego oczyszczeniu na zmianę skuteczności oczyszczania wody, wydajność hydrauliczną membran oraz ich podatność na blokowanie. W badaniach zastosowano membrany ultrafiltracyjne firmy Nadir wykonane z regenerowanej celulozy oraz polieterosulfonu o cut-off 5 - 100 kDa. Testy przeprowadzone zostały dla roztworów modelowych oraz dla wody z rzeki Odry. Przeprowadzone badania wykazały, iż dla wszystkich testowanych membran wzrost wartości ich granicznej masy molowej skutkował wzrostem wydajności hydraulicznej membran. Wykazano też, że zastosowanie membran o większych wymiarach porów skutkuje spadkiem skuteczności usuwania makrocząsteczek organicznych. Zaobserwowano, że charakter hydrofilowo/hydrofobowy polimeru membranotwórczego istotnie wpływał na intensywność blokowania membran. Większy spadek przepuszczalności hydraulicznej membran stwierdzono w przypadku użycia silniej hydrofobowych membran z polieterosulfonu. Analiza uzyskanych wyników badań pozwoliła także wykazać, że wzrost wartości cut-off membran skutkował silniejszym ich blokowaniem, będącym rezultatem zatykania porów membrany.
Źródło:
Rocznik Ochrona Środowiska; 2008, Tom 10; 17-27
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Evaluation of the possibility of replacing the rapid filtration process with ultrafiltration in surface water treatment systems
Autorzy:
Wolska, Małgorzata
Wisniewski, Jacek A.
Ferenc, Zbigniew
Adamski, Wojciech
Mołczan, Marek
Pawłowska, Magdalena
Szerzyna, Slawomir
Powiązania:
https://bibliotekanauki.pl/articles/2032923.pdf
Data publikacji:
2021
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
water treatment
coagulation
sedimentation
filtration
uzdatnianie wody
koagulacja
sedymentacja
filtracja
Opis:
The presented study aimed to compare the effectiveness of ultrafiltration and filtration through a sand bed during the water treatment process after the coagulation and sedimentation. The study was conducted in two flow-type water treatment systems: the reference and the test system. Both systems functioned continuously with a throughput of 1 m3/h. The research has shown that both processes ensured a very effective removal of post-coagulation suspensions, however, ultrafiltration was more effective. The filtration process allowed a slightly higher removal of organic substances as compared to ultrafiltration. The effectiveness of the removal of organic substances was determined by the biological activity of sand beds, which is not allowed in the ultrafiltration process. Besides, during the filtration process, aluminum remaining after coagulation was more effectively removed. In turn, the ultrafiltration process ensured an almost 100% effectiveness in reducing the total microorganism cell count, while the effectiveness of the filtration process was approximately half of that. In the end, the possibility of replacing the filtration process with the ultrafiltration process is determined by the costs of both processes.
Źródło:
Environment Protection Engineering; 2021, 47, 2; 83-92
0324-8828
Pojawia się w:
Environment Protection Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Sonochemical Methods of Removing the Organic Impurities from Water
Metody sonochemiczne usuwania zanieczyszczeń organicznych z wody
Autorzy:
Kusiak, M.
Stępniak, L.
Powiązania:
https://bibliotekanauki.pl/articles/387928.pdf
Data publikacji:
2012
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
uzdatnianie wody
zanieczyszczenia organiczne
ultradźwięki
water treatment
organic impurities
ultrasounds
Opis:
Surface water is characterized by changeability of composition/content and organic intensity of both natural and anthropogenic impurities. As a result of chemical changes developed in the process of oxidation and disinfection, impurities and organic admixtures may become harbingers of damaging by-products of these processes (OBP/DBP). Thus, removing organic impurities from water is a crucial problem in water technology, which predominates in the research subject matter. The decrease of water organic contamination can be obtained by the following methods: coagulation, adsorption, oxidation and membrane processes. The use of different solutions in this field has been researched recently as well. The present research is aimed at so-called ‘hybrid methods’ combining chemical methods with physical factors. For instance, the processes of profound oxidation, in which ultraviolet or ultrasounds are used as hydroxyl radical initiators. The literature based research presented in the first part of the article indicates that the unconventional ultrasound method was described on the basis of the effects obtained with the use of prepared water (most frequently with commercial humic acids preparation). Due to the composition of humic substances in surface water (where fulvic acids are predominant), the verification of these effects in natural water environment is justified. In the following part of the article we presented the research results concerning the effects of the use of ultrasound field with the high intensity and constant frequency of 24 kHz. The substrate for the research was surface water. The laboratory tests were conducted at changing sonification time and vibration amplitude. Changes in water organic impurity were controlled mainly by the TOC index analyses. What was researched as well, was the influence of water pH on the removal of organic impurities measured by the TOC index. In order to characterize it the experiments were conducted at natural water pH, alkaline and acid reaction. At the beginning of the experiment and after the use of the researched sonochemical method we marked the chosen parameters: TOC, DOC, oxygen consumption, UV254, and pH. On the basis of these parameters we evaluated the effects of the process depending on the changing ultrasound parameters.
Wody powierzchniowe charakteryzują się zmiennością składu i stężeń organicznych zanieczyszczeń zarówno naturalnych, jak i antropogennych. Zanieczyszczenia i domieszki organiczne, na skutek przemian chemicznych wywołanych utlenianiem i dezynfekcją, mogą stać się prekursorami szkodliwych ubocznych produktów tych procesów (UPU/UPD). Usuwanie zanieczyszczeń organicznych jest więc istotnym problemem technologii wody, który dominuje w tematyce badawczej. Zmniejszenie organicznego zanieczyszczenia wody uzyskuje się metodą: koagulacji, adsorpcji, utleniania i procesów membranowych. Prowadzone są także badania nad możliwością zastosowania w tym celu także innych rozwiązań. Są one skierowane na tzw. metody hybrydowe, łączące metody chemiczne z czynnikami fizycznymi. Przykładem mogą być procesy pogłębionego utleniania, w których jako inicjatory rodników hydroksylowych wykorzystuje się promieniowanie ultrafioletowe lub ultradźwięki. Badania literaturowe, stanowiące pierwszej część artykułu, wskazują, że niekonwencjonalna metoda ultradźwiękowa jest opisana na podstawie efektów uzyskanych dla wód preparowanych (najczęściej komercyjnymi preparatami kwasów humusowych). Z punktu widzenia składu substancji humusowych w wodach powierzchniowych (gdzie dominują kwasy fulwowe), uzasadniona jest weryfikacja tych efektów w środowisku wód naturalnych. W drugiej części artykułu przedstawiono wyniki badań dotyczące efektów stosowania pola ultradźwiękowego o dużym natężeniu i stałej częstotliwości 20 kHz. Substratem badań była woda powierzchniowa rzeczna pobrana z dwóch źródeł. Testy laboratoryjne prowadzono przy zmiennym czasie nadźwiękowiania i różnej amplitudzie drgań. Kontrolę zmian zanieczyszczenia organicznego wody zapewniały głównie analizy wskaźnika OWO. Na początku eksperymentu i po zastosowaniu badanych metod onochemicznych, wykonywano oznaczenia wybranych parametrów: OWO (TOC), RWO (DOC), utlenialności, UV254 i pH. Na ich podstawie oceniano efekty procesu w zależności od zmiennych parametrów ultradźwiękowych.
Źródło:
Ecological Chemistry and Engineering. A; 2012, 19, 7; 761-770
1898-6188
2084-4530
Pojawia się w:
Ecological Chemistry and Engineering. A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Air purifier – individual protection against indoor particulate matter
Oczyszczacz powietrza – indywidualna ochrona przed pyłem powietrza wewnętrznego
Autorzy:
Chyc, Marek
Powiązania:
https://bibliotekanauki.pl/articles/1032109.pdf
Data publikacji:
2020
Wydawca:
Państwowa Wyższa Szkoła Zawodowa w Tarnowie
Tematy:
pollutants
treatment
allergens
pm10
pm2.5
zanieczyszczenia
uzdatnianie
alergeny
Opis:
The research work presents the findings of testing air purified using two commercial air purifiers available on the local market. Tests were carried out in the office and bedroom of a residential building. The results obtained show a high (75-93%) yield of air purification from particulate matter. Particulate matters fractions such as: PM1, PM2.5, PM4.0, PM10 and total suspended particulates (TSP) were analysed by means professional dust meter. A very strong correlation of particulate matter (PM) contents were found in individual particle classes during equipment operation. Obtained results approve high efficiency of equipment operation in the total range of measured values. This study is one of the first in the topic of assessing the effectiveness of PM purification, taking into account various dust fractions. This study should be useful for individual customers and for public utilities during purchase decisions.
W artykule zaprezentowano wyniki badań powietrza poddanego oczyszczaniu za pomocą dwóch urządzeń komercyjnych dostępnych na polskim rynku. Badania przeprowadzono w pomieszczeniu biurowym i sypialni domu mieszkalnego. Otrzymane wyniki wskazują na wysoki (75-93%) stopień oczyszczenia powietrza. Analizom poddano takie frakcje pyłowe jak: PM1, PM2,5, PM4,0, PM10 i pył całkowity (TSP). Stwierdzono bardzo silną korelację zawartości pyłów w poszczególnych klasach ziarnowych pyłów podczas pracy urządzeń. Oznacza to wysoką skuteczność pracy urządzeń w całym zakresie mierzonych zawartości zanieczyszczeń pyłowych. Opracowanie to jest jednym z pierwszych w zakresie oceny skuteczności oczyszczania pyłów z uwzględnieniem różnych frakcji pyłowych i może stanowić materiał pomocniczy dla użytkowników indywidualnych oraz decydentów rozważających zakup urządzeń oczyszczających powietrze dla jednostek oświatowych.
Źródło:
Health Promotion & Physical Activity; 2020, 10, 1; 13-19
2544-9117
Pojawia się w:
Health Promotion & Physical Activity
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The removal of sulphate ions from model solutions and their influence on ion exchange resins
Autorzy:
Demcak, Stefan
Balintova, Magdalena
Holub, Marian
Powiązania:
https://bibliotekanauki.pl/articles/96354.pdf
Data publikacji:
2020
Wydawca:
Fundacja Ekonomistów Środowiska i Zasobów Naturalnych
Tematy:
ion exchange
resin
sulphate
water treatment
wymiana jonowa
żywica
siarczan
uzdatnianie wody
Opis:
There is a growing tendency for industries around the globe to diminish the contents of pollutants in industrial wastewaters to an acceptable level. Conventional methods are unfavourable and economically unacceptable, especially for large volumes of wastewaters with a high content of undesirable compounds. In contrast, ion–exchange is a very powerful technology capable of removing contamination from water. This paper analyses a study of ion exchange in Amberlite MB20 and Purolite MB400 resins after sulphate removal from a model solution. For the characterisation of ion exchange in resins, infrared spectroscopy was used. The IR spectra of both ion exchange resins show a similar composition after adsorption. Experiments that are due to this same used matrix in producing. The efficiency of sulphate ion removal and pH changes were also measured. Amberlite MB20 has proven to be a suitable ion exchange resin due to its high effi ciency (about 86%) for the removal of sulphates from solutions with initial concentrations of 100 and 500 mg.L-1, respectively.
Źródło:
Ekonomia i Środowisko; 2020, 2; 59-70
0867-8898
Pojawia się w:
Ekonomia i Środowisko
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Change of toxicity of water containing bisphenol A during its treatment by complex oxidation process
Zmiany toksyczności wody zawierającej bisfenol a w trakcie jej uzdatniania w złożonym procesie utleniającym
Autorzy:
Dudziak, M.
Powiązania:
https://bibliotekanauki.pl/articles/388558.pdf
Data publikacji:
2014
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
bisphenol A
water treatment
toxicity
Microtox® biotest
bisfenol A
uzdatnianie wody
toksyczność
biotest Microtox®
Opis:
Water containing bisphenol A was UV irradiated (medium pressure immersion lamp with the electric power of 150 W) with and without the addition of H2O2 (6–12 mg/dm3 dose). To control of the water quality Microtox® biotest was used. Bioluminescent bacteria Vibrio fisheri was involved. Decomposition of bisphenol A was depended on the UV irradiation time and dose of the H2O2. The observations connected with the bioluminescence value in the examined solutions were surprised. Decomposition of the compound did not cause of decrement the bioluminescence inhibition value characterizing solution indicating the formation of toxic intermediates products. However, the combined use of H2O2 with UV radiation improves the rate of decomposition of bisphenol A, but also causes an increase in bioluminescence inhibition of the solutions. For this reason selection of the most favorable conditions for the oxidative process have to be proceed based on both agents: effectiveness of the compounds decomposition and the toxicity of the solution after process.
Wodę zawierającą bisfenol A poddano napromieniowaniu UV (zanurzeniowa lampa średniociśnieniowa o mocy elektrycznej 150 W) bez i z dodatkiem H2O2 (dawka 6–12 mg/dm3). Do kontroli jakości wody zastosowano biotest Microtox® wykorzystujący bakterie bioluminescencyjne Vibrio fisheri. Określono, że rozkład bisfenolu A zależał od czasu napromieniowania UV jak i dawki H2O2. Zaskakujące z kolei były obserwacje związane z wartością inhibicji bioluminescencji w badanych roztworach. Rozkład związku nie powodował obniżenia wartości inhibicji bioluminescencji charakteryzującej roztwór, co wskazuje na powstawanie toksycznych produktów pośrednich. Z kolei łączne zastosowanie nadtlenku wodoru z promieniowaniem UV poprawia stopień rozkładu bisfenolu A, ale jednocześnie powoduje wzrost wartości inhibicji bioluminescencji roztworów. Z tego względu w doborze najkorzystniejszych warunków prowadzenia procesu utleniającego nie można opierać się wyłącznie na skuteczności rozkładu związków, lecz należy również rozważyć toksyczność roztworu poprocesowego.
Źródło:
Ecological Chemistry and Engineering. A; 2014, 21, 3; 269-277
1898-6188
2084-4530
Pojawia się w:
Ecological Chemistry and Engineering. A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Uranium isotopes in public drinking water in Poland
Izotopy uranu w wodach pitnych w Polsce
Autorzy:
Pietrzak-Flis, Z.
Kamińska, I.
Chrzanowski, E.
Powiązania:
https://bibliotekanauki.pl/articles/340776.pdf
Data publikacji:
2004
Wydawca:
Główny Instytut Górnictwa
Tematy:
skażenie uranem
radioaktywne skażenie wody
uzdatnianie wody
uranium contamination
radioactive water contamination
water treatment
Źródło:
Prace Naukowe GIG. Górnictwo i Środowisko / Główny Instytut Górnictwa; 2004, 1; 106-107
1643-7608
Pojawia się w:
Prace Naukowe GIG. Górnictwo i Środowisko / Główny Instytut Górnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Denitrifying phosphorus accumulating organisms enrichment and their characteristics in a denitrifying enhanced biological phosphorus removal system
Autorzy:
Zou, H.
Wang, Y.
Powiązania:
https://bibliotekanauki.pl/articles/206936.pdf
Data publikacji:
2017
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
biological water treatment
wastewater treatment
nitrogen
phosphorus
biologiczne uzdatnianie wody
oczyszczanie ścieków
azot
fosfor
Opis:
Denitrifying phosphorus accumulating organisms (DPAOs) play an important role in simultane-ous removal denitrifying nitrogen (N) and phosphorus (P). Their enrichment and characteristics were investigated. A denitrifying EBPR reactor, performing continuous anaerobic/anoxic conditions, was used to enrich DPAOs in this study. Through 60 days operation, DPAOs was successfully cultivated in the denitrifying EBPR system and P concentration in the effluent was stable and low with less than 0.5 mg/dm3. Energy dispersive spectroscopy (EDS) analysis showed that P content in anoxic end sludge gradually increased with enrichment operation, which accounted for 2.9, 4.7, 6.2, and 7.9 wt. % in sludge samples at day 0 (i.e., seed sludge), and days 20, 40 and 60, respectively. Based on the batch test, a significant positive correlation was found between COD consumption and P release in anaerobic conditions and between nitrogen removal and phosphorus uptake in anoxic conditions. Furthermore, in anaerobic conditions, the P release rate was 4.2 mg P/(g MLSSh) being higher than the P uptake rate (2.8 mg P/(g MLSS h)) in anoxic conditions. Despite this, total anaerobic P release (8.5 mg P/(g MLSS)) was lower than anoxic P uptake total amount (11.2 mg P/(g MLSS)), implying an excess P uptake in anoxic environment. One whole cycle displayed the obviously denitrifying simultaneous nitrogen and phosphorus removal with more than 95% removal efficiencies in the denitrifying EBPR system.
Źródło:
Environment Protection Engineering; 2017, 43, 3; 225-237
0324-8828
Pojawia się w:
Environment Protection Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Dynamic risk assessment method : a proposal for assessing risk in water supply system
Metoda dynamicznego szacowania ryzyka : propozycja oceny ryzyka w systemie zaopatrzenia wody
Autorzy:
Fortmann-Roe, S.
Iwanejko, R.
Wójcik, W.
Powiązania:
https://bibliotekanauki.pl/articles/205339.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
risk
system dynamics
water treatment
waterborne pathogens
ryzyko
dynamika układu
uzdatnianie wody
patogeny wodorozcieńczalne
Opis:
System Dynamics is methodology for modeling and analyzing complex systems. Such systems can be characterized by interconnectedness and feedback. Applying risk assessment to the results of System Dynamics models is a challenge. Though in some cases the resulting time series data generated by a simulation may appear approximately random at a specific scale, there is often a high-degree of auto-correlation within the data series due to the deterministic nature of generation and feedback loops inherent in the system. This paper presents proposed Dynamic Risk Assessment Method (DRAM) that allows for the estimation of risk for system dynamics data series that appear to be approximately random. DRAM is based on standard risk assessment methods and is simple both to calculate and apply. In this article, the proposed method is applied to determine the risk connected with hypothetical costs of illness stemming from water supply system contamination with Cryptosporidium.
Dynamika Systemów jest metodologią modelowania i analizy złożonych systemów. Taki złożony system może być charakteryzowany przez wzajemne proste połączenia elementów oraz istniejące sprzężenia zwrotne. Przeprowadzenie oceny ryzyka przy modelowaniu Systemów Dynamicznych jest trudnym wyzwaniem. Chociaż w niektórych przypadkach, uzyskane za pomocą symulacji serie wyników mogą się wydawać przypadkowe, to jednak często istnieje wysoki stopień autokorelacji między tymi seriami wynikający z istnienia powiązań zwrotnych w systemie. Artykuł przedstawia propozycje Metody Dynamicznego Szacowania Ryzyka (MDSR), która pozwala oceniać ryzyko związane z hipotetycznymi kosztami zachorowań wywołanymi skażeniem systemu zaopatrzenia w wodę przez Cryptosporidium.
Źródło:
Archives of Environmental Protection; 2015, 41, 2; 36-40
2083-4772
2083-4810
Pojawia się w:
Archives of Environmental Protection
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Characteristics of natural organic matter removed from water along with its treatment
Autorzy:
Urbanowska, A.
Kabsch-Korbutowicz, M.
Powiązania:
https://bibliotekanauki.pl/articles/206888.pdf
Data publikacji:
2016
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
biogeochemistry
biological materials
chemical water treatment
Mokry Dwór
WTP
biogeochemia
materiały biologiczne
chemiczne uzdatnianie wody
Opis:
The object of this study was to examine the nature of natural organic matter (NOM) removed on each stage of water treatment train used in the “Mokry Dwór” Wrocław Water Treatment Plant (WTP) and to compare obtained results with water treatment efficiencies achieved with the use of membrane ultrafiltration, ion-exchange and UF/ion-exchange integrated processes. In the experiments fractional analysis with the use of polymeric resins (DAX-8, XAD-4 and IRA-958) was used. Obtained results have shown that most (56%) of the raw water NOM was found in fraction characterized by presence of humic and fulvic acids (VHA and SHA fractions). VHA fraction made the most of DOC removed in examined water treatment train and coagulation was mainly responsible for this effect. Integrated process consisting of MIEX®DOC ion exchange and PES 10 kDa ultrafiltration turned out to be very effective at high molecular weight hydrophobic compounds removal from water being much less efficient with hydrophilic compounds.
Źródło:
Environment Protection Engineering; 2016, 42, 2; 183-195
0324-8828
Pojawia się w:
Environment Protection Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The application of ceramic membranes for treating effluent water from closed-circuit fish farming
Zastosowanie membran ceramicznych do oczyszczania wód poprodukcyjnych z hodowli ryb w obiegach zamkniętych
Autorzy:
Bonisławska, M.
Nędzarek, A.
Drost, A.
Rybczyk, A.
Tórz, A.
Powiązania:
https://bibliotekanauki.pl/articles/204802.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
Membrane filtration
fish farming
African catfish
water treatment
filtracja membranowa
hodowla ryb
sum afrykański
uzdatnianie wody
Opis:
The aim of the study was to analyze and assess the possibility of using a two-stage filtration system with ceramic membranes: a 3-tube module with 1.0 kDa cut-off (1st stage) and a one-tube module with 0.45 kDa cut-off (2nd stage) for treating effluent water from a juvenile African catfish aquaculture. The study revealed that during the 1st filtration stage of the effluent water, the highest degrees of retention were obtained with respect to: suspended solids SS (rejection coefficient RI=100%), turbidity (RI=99.40%), total iron (RI=89.20%), BOD5 (RI=76.0%), nitrite nitrogen (RI=62.30%), and CODCr (RI=41.74%). The 2nd filtration stage resulted in a lower reduction degree of the tested indicators in comparison to the 1st filtration stage. At the 2nd stage, the highest values of the rejection coefficient were noted in for the total iron content (RIV=100%), CODCr (RIV=59.52%; RV=64.28%, RVI=63.49%) and turbidity (RIV and RV = 45.0%, RVI=50.0%). The obtained results indicate that ceramic membranes (with 1.0 and 0.45 kDa cut-offs) may be used in recirculation aquaculture systems as one of the stages of effluent water treatment.
Celem pracy była analiza i ocena możliwości wykorzystania dwustopniowego systemu filtrowania z zastosowaniem membran ceramicznych w postaci modułu 3 rurowego o granicznej rozdzielczości membrany (z ang. cut-off) wynoszącej 1.0 kDa (I stopień) i modułu jednorurowego o granicznej rozdzielczości membrany wynoszącej 0.45 kDa (II stopień), do procesu oczyszczania wód poprodukcyjnych pochodzących z hodowli narybku suma afrykańskiego. Podczas I stopnia procesu filtracji wody poprodukcyjnej badania wykazały, że w najwyższym stopniu zatrzymywane były: zawiesina ogólna SS – RI= 100,0%, mętność RI=99.40%, zawartość żelaza ogólnego RI=89.20%, BZT5 RI=76.0%, oraz azot azotynowy RI=62.30% i ChZTCr RI=41.74%. II stopień procesu filtracji powodował mniejszy stopień redukcji wartości badanych wskaźników niż I stopień procesu filtracji. Wówczas najwyższy współczynnik retencji odnotowano w przypadku zawartości żelaza ogólnego RIV=100%, CODCr RIV=59.52%; RV=64.28%, RVI=63.49% i mętności RIV i RV= 45.0%, RVI=50.0%. Uzyskane wyniki wskazują na możliwość wykorzystania membran ceramicznych (o cut-off 1.0 i 0.45 kDa) w recyrkulacyjnych systemach akwakultury, jako jeden z etapów oczyszczania wód poprodukcyjnych.
Źródło:
Archives of Environmental Protection; 2016, 42, 2; 59-66
2083-4772
2083-4810
Pojawia się w:
Archives of Environmental Protection
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies