Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "temperature monitoring" wg kryterium: Temat


Tytuł:
Temperature Monitoring during Focused Ultrasound Treatment by Means of the Homodyned K Distribution
Autorzy:
Byra, M.
Kruglenko, E.
Gambin, B.
Nowicki, A.
Powiązania:
https://bibliotekanauki.pl/articles/1032313.pdf
Data publikacji:
2017-06
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
temperature monitoring
homodyned K distribution
focused ultrasound
Opis:
Temperature monitoring is essential for various medical treatments. In this work, we investigate the impact of temperature on backscattered ultrasound echo statistics during a high intensity focused ultrasound treatment. A tissue mimicking phantom was heated with a spherical ultrasonic transducer up to 56°C in order to imitate tissue necrosis. During the heating, an imaging scanner was used to acquire backscattered echoes from the heated region. These data was then modeled with the homodyned K distribution. We found that the best temperature indicator can be obtained by combining two parameters of the model, namely the backscattered echo mean intensity and the effective number of scatterers per resolution cell. Next, ultrasonic thermometer was designed and used to create a map of the temperature induced within the tissue phantom during the treatment.
Źródło:
Acta Physica Polonica A; 2017, 131, 6; 1525-1528
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Temperature detection based on nonparametric statistics of ultrasound echoes
Autorzy:
Byra, M.
Gambin, B.
Powiązania:
https://bibliotekanauki.pl/articles/332315.pdf
Data publikacji:
2015
Wydawca:
Polskie Towarzystwo Akustyczne
Tematy:
noninvasive temperature monitoring
nonparametric statistics
ultrasound backscattering
Opis:
Different ultrasound echoes properties have been used for the noninvasive temperature monitoring. Temperature variations that occur during heating/cooling process induce changes in a random process of ultrasound backscattering. It was already proved that the probability distribution of the backscattered RF (radio frequency) signals is sensitive to the temperature variations. Contrary to previously used methods which explored models of scattering and involved techniques of fitting histograms to a special probability distribution two more direct measures of changes in statistics are proposed in this paper as temperature markers. They measure the ''distance'' between the probability distributions. The markers are the Kolmogorov Smirnov distance and Kulback-Leiber divergence. The feasibility of using such nonparametric statistics for non- invasive ultrasound temperature estimation is demonstrated on the ultrasounds data collected during series of heating experiments in which the temperature was independently registered by the classical thermometer or thermocouples.
Źródło:
Hydroacoustics; 2015, 18; 17-23
1642-1817
Pojawia się w:
Hydroacoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Temperature Monitoring of Marsh Landscapes and Development of Exogenous Processes in the West Siberian Plain (Russia)
Autorzy:
Korkin, S.
Korkina, E.
Kail, E.
Powiązania:
https://bibliotekanauki.pl/articles/100753.pdf
Data publikacji:
2018
Wydawca:
Uniwersytet Śląski. Wydział Nauk o Ziemi
Tematy:
temperature monitoring
marsh landscapes
exogenous process
technogenic impact
engineering impact
monitorowanie temperatury
krajobraz bagienny
procesy egzogeniczne
technika
Syberia
Opis:
The research touches upon marsh landscapes in the context of temperature monitoring and in connection with exogenous processes during engineering intervention. The monitoring of temperature regimes was conducted in the mid-taiga subzone of marsh landscapes for revealing the dynamics of exogenous processes. The authors used the method of recording systems for the field measurement of the temperature of the peat and underlying soils. The measurements were conducted on a territory that belongs to the middle taiga landscapes of Western Siberia. The authors of the research analyze the data obtained from thermowells 5, 5a and 6. During the observation period of 2015-2016, the average annual temperature was 8.3ºС for thermowell 5a (technogenic area), which is 3.8ºС and 4.2ºС higher than the average annual values of thermowell 5 and thermowell 6 respectively. The latter belongs to natural marsh landscapes. Observations conducted in 2016-2017 confirmed this fact with a difference of 4.8ºС and 3.7ºС for thermowells 5 and 6 respectively. As compared to natural marsh landscapes not affected by manmade impact, a higher temperature was observed on soils, which affects the manifestation of exogenous processes.
Źródło:
Contemporary Trends in Geoscience; 2018, 7, 2; 133-144
2299-8179
Pojawia się w:
Contemporary Trends in Geoscience
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Remote monitoring of semiconductor switches’ temperatures in a bidirectional DC / AC / DC converter
System zdalnego monitorowania temperatur tranzystorów przekształtnika DC / AC / DC
Autorzy:
Wojtkowski, W.
Powiązania:
https://bibliotekanauki.pl/articles/267354.pdf
Data publikacji:
2018
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
digital temperature sensors
temperature monitoring system
1-Wire bus
node-RED
cyfrowe czujniki temperatury
system monitorowania temperatury
magistrala 1-Wire
Node-RED
Opis:
The paper presents a temperature monitoring system of a bidirectional DC / AC / DC converter. The system allows for remote monitoring of two temperatures (the number can be increased if necessary). The monitoring console is available on any mobile or stationary device connected to the local Wi-Fi network or to the Internet (if it has a static IP). By implementing the remote monitoring, important temperatures of working converter can be monitored from any place with the Internet access. The presented solution may be used in laboratories developing new topologies of power converters that should be monitored for a long time before practical implementation.
W artykule przedstawiono system zdalnego monitorowania temperatur półprzewodnikowych przyrządów mocy w przekształtniku DC / AC / DC. Prezentowany system pozwala na monitorowanie dwóch temperatur, jednak liczbę czujników oraz aktuatorów można znacznie rozszerzyć w razie potrzeby. Aktualnie monitorowane są dwie temperatury radiatorów górnego i dolnego mostka przekształtnika DC /AC /DC. Proponowane rozwiązanie bazuje na cyfrowych czujnikach temperatury DS18B20. Są one podłączone poprzez magistralę 1-Wire z jednopłytkowym mikrokomputerem Raspberry Pi w wersji 3. Interfejs 1-Wire oraz interfejs użytkownika umożliwiający monitorowanie temperatur zostały zaprojektowane w środowisku Node-RED. Konsola użytkownika jest dostępna na każdym urządzeniu podłączonym do lokalnej sieci Wi-Fi. Jeśli zastosowane Raspberry Pi posiada stały adres IP dostęp do konsoli jest możliwy z sieci Internet. Proponowane rozwiązanie może być przydatne przy projektowaniu i badaniu nowych konfiguracji i topologii pracy przekształtników energoelektronicznych, które powinny być testowane przez długi czas w laboratorium zanim znajdą zastosowanie komercyjne. System umożliwia przesyłanie sygnałów do przekształtnika czyli zdalne ustawienia.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2018, 59; 207-210
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of Temperatures in the Cold Storage of Finished Products
Autorzy:
Bogdanovská, Gabriela
Stehlíková, Beáta
Kačur, Ján
Powiązania:
https://bibliotekanauki.pl/articles/102539.pdf
Data publikacji:
2019
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
cold storage warehouse
temperature monitoring
temperature fluctuations
statistical evaluation
Kruskal-Wallis test
Bartlett test
Nemenyi’s test
magazyn chłodniczy
monitorowanie temperatury
wahania temperatury
ocena statystyczna
test Kruskala-Wallisa
test Bartletta
test Nemenyi
Opis:
The analysis of temperatures in the cold store of finished products was performed due to the occurrence of temperature fluctuations. The analysis in the report was conducted using Kruskal-Wallis test, Bartlett test, Nemenyi’s test Statistical analysis of measured values in individual months. The relationship between the temperature in the cold store and the outside air temperature was investigated. Quality tools were also used in the thesis. The causes of temperature fluctuations were determined by Cause-Effect diagnostics. The relationship between the main causes was analyzed with Relation Diagram. Corrective measures were then determined to minimize the temperature fluctuations in the cold store.
Źródło:
Advances in Science and Technology. Research Journal; 2019, 13, 3; 54-66
2299-8624
Pojawia się w:
Advances in Science and Technology. Research Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Seasonal variation of radon and CO2 in the Važecká Cave, Slovakia
Autorzy:
Smetanová, Iveta
Holý, Karol
Luhová, Ľubica
Csicsay, Kristian
Haviarová, Dagmar
Kunáková, Lucia
Powiązania:
https://bibliotekanauki.pl/articles/147448.pdf
Data publikacji:
2020
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
carbon dioxide
cave
monitoring
radon
temperature
variation
Opis:
The continuous monitoring of 222Rn activity concentration, CO2 concentration, and microclimatologic parameters (internal air temperature and relative humidity) in the Važecká Cave (Northern Slovakia) is being carried out at three monitoring stations, namely, Gallery, Lake Hall, and Entrance Hall. Radon activity concentration and CO2 concentration exhibited a clear annual variation. The daily average of radon concentration ranged 1300–27 700 Bq/m3 at the Lake Hall station and 3600–42 200 Bq/m3 at the Gallery station. Radon reached its maximum in the summer months, from June to September. The annual maximum of CO2 concentration is registered approximately one month later than radon maximum. The annual variation of radon and CO2 is controlled by the seasonal change of ventilation regime associated with the seasonal variation of the difference between the temperature measured inside the cave and the atmospheric temperature.
Źródło:
Nukleonika; 2020, 65, 2; 153-157
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effect of the multiple damages and temperature changes on the natural frequency
Autorzy:
Mohammadi Esfarjani, S.
Salehi, M.
Ghassemi, A.
Powiązania:
https://bibliotekanauki.pl/articles/279351.pdf
Data publikacji:
2017
Wydawca:
Polskie Towarzystwo Mechaniki Teoretycznej i Stosowanej
Tematy:
structural health monitoring
damage detection
vibration response
temperature
natural frequency
Opis:
Damage detection based on structural dynamic characteristics, such as natural frequencies and mode shapes, is an important area of research. Obtaining accurate structural dynamic characteristics is perhaps the most challenging aspect. In particular, changes in environmental temperature due to seasonal weather or radiation from sunshine leads to changes in the dynamic characteristics of structures. An important conclusion is that changes in the dynamic characteristics of a structure due to damage may be smaller than changes in the dynamic characteristics due to variations in temperature. Also, damage can affect the frequency response. This is the first study of evaluation of the effect of changes in temperature and multiple damages on natural frequency at the same time. In this paper, the simultaneous effect of the multiple defects and temperature on the natural frequencies of 6063 aluminum alloy beam are assessed numerically. ABAQUS finite element software is used for the numerical analysis. The present paper aims to evaluate the temperature effect and multiple damages on vibration responses. The variations in the frequency have been analysed in simulation by using an aluminum specimen and obtaining impedance signatures at temperatures ranging from −200◦C to 204◦C. The results show that an increase in temperature leads to a decrease in structural frequency, and that a decrease in temperature leads to an increase in structural frequency. The evaluation of the effect of multiple defects on natural frequency shows that when damages are created in the structure, there is a significant decrease in the natural frequency responses of the 6063 aluminum alloy beam. The results show that damage causes a decrease in the natural frequency of the structure. This study highlights the importance of applying simulation methods to the evaluation of the effect of changes in environmental temperature and multiple damages on the dynamic characteristics such as natural frequencies and mode shapes, especially at the same time.
Źródło:
Journal of Theoretical and Applied Mechanics; 2017, 55, 3; 813-822
1429-2955
Pojawia się w:
Journal of Theoretical and Applied Mechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Researches regarding the evolution of the coal deposits in “Rosia de Jiu” quarry
Badania dotyczące ewolucji złóż węgla w kopalni “Rosia de Jiu”
Autorzy:
Radu, S. M.
Matei, A.
Mititica, T.
Ionitescu, N.
Powiązania:
https://bibliotekanauki.pl/articles/405727.pdf
Data publikacji:
2014
Wydawca:
Politechnika Częstochowska
Tematy:
lignite
monitoring
self-heating
self-oxidation
temperature
węgiel brunatny
samonagrzewanie
samoutlenianie
temperatura
Opis:
To study the evolution of the temperature of the stock of coal depending on its storage period, the used method in managing the coal storages is the use of infrared thermography. Infrared thermography allows for the temperatures to be remotely measured (from centimetres to a hundreds of meters) and without direct contact, which is indispensable, for example considering electrical equipment found under tension or in the case of parts or materials with increased temperature or which are inaccessible. The evolution of the measured temperature took into account the following steps: the initiation and appearance of temperature areas, the development phase of the temperature areas and the phase during which the increased temperature cores appear. The evolution of the temperature on steps is presented in data and in graphical mode. After the measurements the entire coal quantity which was analysed was sent to be consumed.
Do badania rozwoju temperatury zapasów węgla w zależności od ich okresu składowania, stosowaną metodą zarządzania magazynami węgla jest termografia podczerwieni. Termografia podczerwieni umożliwia zdalne mierzenie temperatury (od centymetrów do setek metrów) oraz bez bezpośredniego kontaktu, który jest niezbędny, na przykład biorąc pod uwagę urządzenia elektryczne pod napięciem lub w przypadku części lub materiałów o podwyższonej temperaturze lub które są niedostępne. Ewolucja zmierzonej temperatury uwzględniła następujące kroki: inicjacji i wyglądu obszarów temperatury, fazy rozwoju obszarów temperatury i fazy, podczas której pojawiają się rdzenie zwiększonej temperatury. Rozwój temperatury w krokach przedstawiono w danych oraz w postaci graficznej. Po zakończeniu pomiarów całkowita ilość węgla, który analizowano została wysłana do konsumpcji.
Źródło:
Polish Journal of Management Studies; 2014, 10, 2; 172-178
2081-7452
Pojawia się w:
Polish Journal of Management Studies
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Thermal monitoring for Metallic Additive Manufacturing multi-beads multi-layers parts
Autorzy:
Rauch, Matthieu
Hascoet, Jean-Yves
Rousseau, Clement
Ruckert, Guillaume
Powiązania:
https://bibliotekanauki.pl/articles/1833770.pdf
Data publikacji:
2021
Wydawca:
Wrocławska Rada Federacji Stowarzyszeń Naukowo-Technicznych
Tematy:
wire arc additive manufacturing
thermal indicator
thermal online monitoring
high temperature zone
Opis:
Among Metallic Additive Manufacturing processes, Directed Energy Deposition (DED) processes are very promising for the Industry. An issue that prevents a larger development of DED is the reliability of the process, since its complexity makes the result of the manufacturing variable. Thermal behavior is a critical aspect for which uncontrolled phenomena can lead to part failure. Some thermal monitoring and closed-loop control methods have been developed, that enables to observe and regulate the heating of the processed part. However, these methods rely on local measures from a region or a single external surface of a part, and thus provide partial information of thermal fields in the whole part volume. This paper proposes a method that combines diverse data to compute online a process indicator that is meaningful for the thermal state of the whole part, and hence for the control of the manufacturing of multi-beads multi-layer parts. A simulation-based model using thermal partial data is proposed. An online monitoring experiment is proposed for validation of the model. Relevance of the control method to ensure mechanical properties of the part is then tested.
Źródło:
Journal of Machine Engineering; 2021, 21, 3; 92--100
1895-7595
2391-8071
Pojawia się w:
Journal of Machine Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Challenges in Integrating Wireless Sensor Network and Internet of Things for Environmental Monitoring
Autorzy:
Vijayalakshmi, S. R.
Muruganand, S.
Powiązania:
https://bibliotekanauki.pl/articles/1193537.pdf
Data publikacji:
2016
Wydawca:
Przedsiębiorstwo Wydawnictw Naukowych Darwin / Scientific Publishing House DARWIN
Tematy:
Environmental monitoring
Internet of Things
Temperature and humidity measurement
Wireless Sensor Network
Opis:
Hardware technology developments and wireless communications enables the development of wireless sensor networks (WSNs). WSN will need to be connected to the Internet due to its variety of applications and their importance. This paper discusses the challenges in integrating WSN and IoT (Internet of Things). The best ways of integrating WSN and IoT for environmental monitoring are analyzed. The sensor node is developed to monitor environmental parameters such as temperature and humidity. The sensor SHT75 to sense the temperature and humidity of the environment, XBeePro to communicate with gateway, LCD to display information are interfaced with MSP430 Microcontroller. The microcontroller is used for processing, controlling and communicating the information. The sensor nodes are deployed to measure the parameter in the target area. The information is communicated to the world of Internet in one of the best integrating ways discussed in the paper.
Źródło:
World Scientific News; 2016, 41; 1-8
2392-2192
Pojawia się w:
World Scientific News
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Vehicle transport organization of food requiring refrigeration
Organizacja transportu samochodowego żywności wymagającej chłodzenia
Autorzy:
Pawlak, H.
Maksym, P.
Skwarcz, J.
Powiązania:
https://bibliotekanauki.pl/articles/793371.pdf
Data publikacji:
2014
Wydawca:
Komisja Motoryzacji i Energetyki Rolnictwa
Tematy:
perishable product
food transport
refrigeration
car transport
air temperature
monitoring
legal requirement
Źródło:
Teka Komisji Motoryzacji i Energetyki Rolnictwa; 2014, 14, 4
1641-7739
Pojawia się w:
Teka Komisji Motoryzacji i Energetyki Rolnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Investigations of dynamic characteristics of a tall industrial chimney due to light wind and solar radiation
Badania dynamicznych charakterystyk wysokiego komina pod działaniem słabego wiatru i nasłonecznienia
Autorzy:
Breuer, P.
Chmielewski, T.
Górski, P.
Konopka, E.
Tarczyński, L.
Powiązania:
https://bibliotekanauki.pl/articles/391157.pdf
Data publikacji:
2013
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Tematy:
chimney
monitoring
GPS
wind
temperature
dynamic
damping
komin
wiatr
nasłonecznienie
dynamika
tłumienie
Opis:
The present paper describes field tests conducted on the 300 m tall industrial chimney, located in the power station of Bełchatów (Poland), where the GPS rover receivers were installed at three various levels. The objectives of these GPS tests were to investigate the deformed vertical profile of this chimney, and its dynamic characteristics, i.e. the first natural frequency and the modal damping ratios. The results for the satellite signal receptions, the synopsis of recorded baselines and their ambiguity solutions, drifts of the chimney due to solar radiation and air temperature variations and dynamic wind response characteristics are presented.
W ostatnich piętnastu latach powstała nowa dziedzina monitoringu dużych budowli inżynierskich wykorzystująca technologię GPS. W niniejszej pracy opisano badania przeprowadzone na wysokim, 300-metrowym kominie przemysłowym elektrowni Bełchatów, gdzie odbiorniki GPS umieszczono w trzech różnych poziomach. Według rozeznania autorów jest to pierwszy przypadek takiego użycia techniki GPS do obserwacji wysokiej budowli pod równoczesnym działaniem słabego wiatru oraz zmian temperatury otoczenia i nasłonecznienia. Celem badań było wyznaczenie geometrii odkształconej osi pionowej trzonu komina i jego parametrów dynamicznych, tj. pierwszej częstości drgań własnych i modalnych liczb tłumienia. Opisano warunki odbioru sygnałów satelitarnych systemu GPS, przedstawiono wyniki pomiarów przemieszczeń trzonu wywołanych nasłonecznieniem i wyniki analizy odpowiedzi dynamicznej konstrukcji komina wywołanej działaniem wiatru.
Źródło:
Budownictwo i Architektura; 2013, 12, 2; 87-94
1899-0665
Pojawia się w:
Budownictwo i Architektura
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Airborne birch pollen in Poland and Latvia in the light of data obtained from aerobiological monitoring and Tauber traps in relation to mean air temperature
Pylenie brzozy w Polsce i na Łotwie w świetle danych z monitoringu aerobiologicznego i pułapek Taubera na tle średniej temperatury powietrza
Autorzy:
Pidek, I. A.
Piotrowska, K.
Kaszewski, B. M.
Kalnina, L.
Weryszko-Chmielewska, E.
Powiązania:
https://bibliotekanauki.pl/articles/28621.pdf
Data publikacji:
2009
Wydawca:
Polskie Towarzystwo Botaniczne
Tematy:
airborne pollen
birch pollen
pollen
Polska
Latvia
aerobiological monitoring
Tauber trap
air temperature
pollen monitoring
volumetric method
Lublin city
Opis:
Birch pollen contains allergens belonging to those with the strongest allergenic properties. In order to trace pollen season patterns of this taxon and pollen annual sums at a wider regional scale, cooperation was established with the University of Latvia in Riga (Latvia). A comparison of the results obtained in the years 2003-2008 in Lublin and in Riga, using volumetric samplers, shows that there was a similar trend in the abundance of birch pollen. The highest sums were noted at both sites in 2003. In all the study years, more birch pollen grains were recorded in Lublin than in Riga, on the average by 7110. The birch pollen seasons started earlier in Lublin than in Riga, on the average by 6 days, and they ended earlier in Lublin, on the average by 18 days. In Riga the birch pollen seasons were longer and less abundant than in Lublin. In addition, in both the regions, i.e. in SE Poland (the Roztocze area) and in Latvia (the area of Marupe near Riga, Taurene, Teici and Rucava), there is pollen data series available obtained from annual pollen deposition monitoring conducted using the modified Tauber traps. These pollen counts have been carried out under the Pollen Monitoring Programme (http://pmp.oulu.fi) since 1998. The 11- year data series in Roztocze and the 10-year data series in Latvia allowed the trends in the occurrence of years of abundant or poor birch pollen release to be traced. In Roztocze maximum Betula pollen deposition occurred in the year 2003, in Latvia – in 1999. The absence of a significant correlation between SE Poland and Latvia with regard to the trends in the occurrence of years of abundant Betula pollen deposition induced the authors to seek climatic factors responsible for increased birch pollen production. The analysis of the Spearman’s rank correlation coefficients between annual Betula pollen sums in Roztocze and mean air temperature in June, July and August in the year preceding pollen emission as well as in spring (January-April) of the year of pollen emission showed a statistically significant negative correlation with air temperature in February of the year of pollen emission.
Pyłek brzozy zawiera alergeny należące do najsilniej uczulających z grupy alergenów pyłku roślin. Celem prześledzenia, jak kształtuje się przebieg sezonów pyłkowych tego taksonu oraz sumy roczne pyłku w szerszej skali regionalnej, nawiązano współpracę z Uniwersytetem w Rydze (Łotwa). Z porównania wyników uzyskanych w latach 2003-2008 w Lublinie i w Rydze przy zastosowaniu aparatów wolumetrycznych wynika, że istniała zbliżona tendencja w wielkości sum rocznych pyłku brzozy. Najwyższe sumy odnotowano na obydwu stanowiskach w roku 2003. We wszystkich latach badań w Lublinie rejestrowano więcej ziaren pyłku brzozy niż w Rydze, średnio o 7110. Sezony pyłkowe brzozy rozpoczynały się wcześniej w Lublinie niż w Rydze średnio o 6 dni i kończyły się wcześniej w Lublinie średnio o 18 dni. W Rydze sezony pyłkowe brzozy były dłuższe i sumy roczne pyłku mniejsze niż w Lublinie. W obydwu regionach, tj. w Polsce SE (rejon Roztocza) i Łotwie (rejon Marupe k. Rygi, Taurene, Teici i Rucava) istnieje ponadto seria danych pyłkowych uzyskanych z monitoringu rocznej depozycji pyłku do zmodyfikowanych pułapek Taubera. Pomiary te wykonywane są w ramach międzynarodowego projektu Pollen Monitoring Programme (http://pmp.oulu.fi) od 1998 roku. Aktualnie seria danych licząca 11 lat na Roztoczu i 10 lat na Łotwie pozwoliła prześledzić tendencje w występowaniu lat obfitego lub słabego opadu pyłku brzozy. Na Roztoczu maksimum depozycji pyłku Betula przypada na rok 2003, na Łotwie – w 1999 roku. Brak zgodności między Polską SE i Łotwą w zakresie tendencji w występowaniu lat obfitej depozycji pyłku Betula skłoniło do poszukiwania czynników klimatycznych odpowiedzialnych za zwiększoną produkcje pyłku brzozy. Analiza współczynników korelacji rang Spearmana pomiędzy rocznymi sumami pyłku Betula na Roztoczu i średnią temperaturą powietrza w czerwcu, lipcu i sierpniu w roku poprzedzającym pylenie oraz wiosną (styczeń-kwiecień) w roku pylenia, wykazała istotną statystycznie negatywną korelację z temperaturą powietrza w lutym w roku pylenia.
Źródło:
Acta Agrobotanica; 2009, 62, 2
0065-0951
2300-357X
Pojawia się w:
Acta Agrobotanica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Evaluation of Optical Fiber Macrobendings in Temperature Sensor Dedicated for Power Transformer Monitoring
Ocena wprowadzanych makrozgięć na światłowodzie na działanie czujnika temperatury dedykowanego do monitorowania transformatorów
Autorzy:
Guzowski, Bartłomiej
Łakomski, Mateusz
Shatarah, Iyad S. M.
Powiązania:
https://bibliotekanauki.pl/articles/27312472.pdf
Data publikacji:
2023
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Automatyki i Pomiarów
Tematy:
GaAs sensor
temperature
power transformer
optical fiber
monitoring
sensor GaAs
temperatura
transformator
światłowód
monitorowanie
Opis:
Optical fiber sensing techniques are recognized as very promising in diagnostic and condition monitoring of power transformers. According to the IEC standard 60076-2, the winding hot-spot temperature can be designated with the optical fiber sensor. In this paper, the investigation of the influence of macrobending of the optical fiber temperature sensor on the sensing performance is presented. The obtained results prove that the optical fiber sensor wrapped six times around the 14 mm cylinder still provides temperature sensing abilities.
Sensory światłowodowe doskonale sprawdzają się w diagnostyce i monitorowaniu stanu transformatorów. Norma IEC 60076-2:2011 wskazuje na możliwość użycia czujników światłowodowych do pomiaru temperatury uzwojenia transformatora. W niniejszym artykule badany jest wpływ makrozgięć na działanie światłowodowego czujnika temperatury. Uzyskane dane potwierdzają, że czujnik nadal działa prawidłowo, pomimo wprowadzonego makrozgięcia w postaci sześciokrotnego zawinięcia światłowodu wokół cylindra o średnicy 14 mm.
Źródło:
Pomiary Automatyka Robotyka; 2023, 27, 4; 39--44
1427-9126
Pojawia się w:
Pomiary Automatyka Robotyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modification of the procedure of diagnostic inference for TPMS
Modyfikacja procedury wnioskowania diagnostycznego dla układu TPMS
Autorzy:
Cieślikowski, B.
Cygnar, M.
Kochanek, A.
Powiązania:
https://bibliotekanauki.pl/articles/334808.pdf
Data publikacji:
2016
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Maszyn Rolniczych
Tematy:
TPMS
Tyre-Pressure Monitoring System
tyre
temperature control
procedure
układ TPMS
kontrola temperatury
opona
procedura
Opis:
The subject of the paper is to modify the procedure of inference for TPMS (Tyre-Pressure Monitoring System) with regard to an earlier identification of the excessive temperature rise in tyres before they exceed thermal limits. This shall allow to limit the risk of accidents caused by destruction of a tyre. An important issue indicating functional features of TPMS consists in a possibility of rapidly warning a driver immediately after a potentially dangerous rise of temperature. Traction tests have been carried out with use of a passenger car equipped with TPMS with P409 sensors and TH9P409S measuring module. Time characteristics of tyre temperature signals were included indicating the way of their use for the process of estimation of a warning signal. A change trend model of an analysed parameter in time function was developed.
Przedmiotem publikacji jest modyfikacja procesu wnioskowania w systemie TPMS (Tyre Pressure Monitoring System) w zakresie wcześniejszej identyfikacji nadmiernego przyrostu temperatury opony zanim zostaną przekroczone limity dopuszczalne. Pozwoli to na ograniczenie skutków destrukcji opony zmniejszając przy tym ryzyko wypadkowości. Istotnym zagadnieniem wyrażającym cechy funkcjonalne układu TPMS jest zdolność szybkiej estymacji sygnału ostrzegawczego o stanie awaryjnym opony. Przeprowadzono testy trakcyjne samochodu osobowego wyposażonego w układ TPMS z czujnikami P409 i modułem pomiarowym TH9P409S. Zamieszczono charakterystyki czasowe sygnałów temperatury opony wskazując na ich wykorzystanie dla estymacji sygnału ostrzegawczego. Opracowano model trendu zmiany analizowanego parametru w funkcji czasowej.
Źródło:
Journal of Research and Applications in Agricultural Engineering; 2016, 61, 3; 53-56
1642-686X
2719-423X
Pojawia się w:
Journal of Research and Applications in Agricultural Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies