Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "straty ciepła" wg kryterium: Temat


Wyświetlanie 1-9 z 9
Tytuł:
Selected scientific and engineering applications of infrared technology
Wybrane naukowe i inżynierskie zastosowania techniki termowizyjnej
Autorzy:
Jandačka, J.
Kapjor, A.
Malcho, M.
Orman, Ł. J.
Powiązania:
https://bibliotekanauki.pl/articles/402130.pdf
Data publikacji:
2013
Wydawca:
Politechnika Świętokrzyska w Kielcach. Wydawnictwo PŚw
Tematy:
heat losses
infrared measurements
visualizations
straty ciepła
pomiary termowizyjne
wizualizacje
Opis:
The paper presents applications in infrared measurements. It discusses the use of thermovision in the analysis of heat losses in buildings, environmental monitoring, scientific research in thermal fields on different surfaces and other. Examples of the infrared measurements are given and discussed in the text.
Źródło:
Structure and Environment; 2013, 5, 2; 31-39
2081-1500
Pojawia się w:
Structure and Environment
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Natural gas saving and emissions decrease in public health care sector – a case study
Ograniczenie zużycia gazu ziemnego i redukcja emisji w sektorze zdrowia publicznego – studium przypadku
Autorzy:
Mierka, Otto
Variny, Miroslav
Skalíková, Ingrida
Sámel, Peter
Kizek, Ján
Súth, Róbert
Nagy, Karol
Powiązania:
https://bibliotekanauki.pl/articles/396176.pdf
Data publikacji:
2019
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
public building
health care sector
natural gas
emission
heat loss
budynek użyteczności publicznej
gaz ziemny
emisja
straty ciepła
Opis:
A study on natural gas saving and emissions decrease in the public health care sector is presented. The analyzed hospital complex belongs to the largest ones in Slovakia and uses both hot water and water steam for heating purposes. Visual steam system inspection revealed serious inefficiencies, including steam venting, missing pipelines insulation and obsolete steam sources with dysfunctional blow-down system. Defined experiment with stepwise steam appliances shutdown enabled quantification of excess natural gas consumption due to these inefficiencies. Measures proposed for the solution of this state are inexpensive, with a short payback period. The expected natural gas savings amount up to 3200 MWh/year, which represents roughly 50% of the total natural gas consumption in the hospital complex.
Niniejszy artykuł prezentuje studium przypadku na temat ograniczenia zużycia gazu ziemnego i emisji w sektorze zdrowia publicznego. Analizowany kompleks szpitalny należy do największych na Słowacji i używa do ogrzewania zarówno ciepłej wody użytkowej, jak i pary wodnej. Kompleks ten będzie w najbliższych latach poddany renowacji, włącznie z instalacją dystrybucji mediów. Analiza obecnego systemu i wynikające z niej zaproponowane sposoby na zaoszczędzenie energii oferują redukcję kosztów powiązanych z przyszłą inwestycją. Wizualna ocena systemu dystrybucji pary wodnej ujawniła poważne wady tego systemu, w tym w odpowietrzaniu systemu, uszkodzonej bądź brakującej izolacji rur, przestarzałych bojlerach parowych z niedziałającym systemem usuwania zanieczyszczeń. Eksperyment ze stopniowym wyłączaniem urządzeń parowych umożliwił ilościowe określenie nadmiaru zużycia gazu ziemnego spowodowanego wspomnianymi niedostatkami. Metodologia takiego eksperymentu jest uniwersalna i łatwa w zastosowaniu w jakimkolwiek innym budynku użyteczności publicznej gdzie podobny system pary wodnej jest w użyciu. Zaproponowane rozwiązania dla poprawy takiego stanu są niedrogie i z krótkim czasem zwrotu inwestycji. Zastosowanie nowej izolacji rur, naprawa odwadniaczy oraz naprawa zaworów redukcyjno-regulacyjnych do odpowietrzania pary w odpowietrznikach są przedmiotem rozważań. Oczekiwana redukcja zużycia gazu ziemnego wynosi do 3200 MWh/rok, co stanowi około 50% rocznego zapotrzebowania tego gazu w kompleksie szpitalnym. Ocena środowiskowa zaproponowanych zmian pozwala oczekiwać redukcji emisji dwutlenku węgla na poziomie 644 ton rocznie oraz tlenków azotu na poziomie 0.75 ton rocznie.
Źródło:
Civil and Environmental Engineering Reports; 2019, 29, 1; 119-127
2080-5187
2450-8594
Pojawia się w:
Civil and Environmental Engineering Reports
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Energetic & exergetic analysis of a parabolic trough: concentrated solar power plant
Autorzy:
Nagpal, Mohit
Maithani, Rajesh
Kumar, Suresh
Powiązania:
https://bibliotekanauki.pl/articles/2142893.pdf
Data publikacji:
2021
Wydawca:
Centrum Badań i Innowacji Pro-Akademia
Tematy:
solar energy
exergy
thermal efficiency
heat gain
heat losses
parabolic trough
collectors
energia słoneczna
egzergia
wydajność termiczna
zyski ciepła
straty ciepła
kolektory
Opis:
Solar energy is the most affordable source of energy. Parabolic trough systems are used to concentrate and extract heat, therefore it’s very significant to analyse its performance in terms of energy and exergy. Exergy based analysis of the system ensures the eradication of losses, resulting in the yield of energy of the highest quality. In this paper, an investigation has been carried out using numerical simulation with an objective of analysis of Parabolic Trough Collectors on the basis of energy and exergy. Detailed second law analysis has been performed by varying the system and operating parameters through computer simulation. Exergy output has been determined by analysing the effect of major system parameters, namely, mirror reflectivity, glass transmissivity, absorptivity, the diameter of glass envelop, and the receiver. The operating parameters considered in the investigation are insolation and temperature rise parameters. The extensive investigation of the parabolic trough of a concentrated solar power plant for various design parameters in the range of operating parameters reveals that it is beneficial to operate the system at higher temperature as opposed to the preference of the operating system at lower temperature from purely thermal considerations.
Źródło:
Acta Innovations; 2021, 40; 19-30
2300-5599
Pojawia się w:
Acta Innovations
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The assessment of effect of selected elements on the heat losses
Ocena wpływu wybranych parametrów na straty ciepła
Autorzy:
Lis, A.
Powiązania:
https://bibliotekanauki.pl/articles/2065208.pdf
Data publikacji:
2013
Wydawca:
Politechnika Częstochowska
Tematy:
heat losses
heat balance conditions
heat consumption for heating buildings
single-family buildings
bilans cieplny budynku
straty ciepła
zużycie ciepła do ogrzewania budynków
budynki mieszkalne jednorodzinne
Opis:
The paper presents the results of investigations on building’s heat losses. The heat balance conditions in selected buildings were observed. The factors which influence on heat losses in analysed buildings were identified. The changes of value of these quantities on the influence of individual factors were estimated. Figures illustrate the formation of values related to heat losses in given buildings depending on the selected factors. Regression equations correlations and coefficients were determined.
W pracy przedstawiono rezultaty badań dotyczących strat ciepła z budynków. Analizowano bilans cieplny wybranych budynków mieszkalnych jednorodzinnych. Określono parametry wpływające na straty ciepła z budynków. Oszacowano wpływ wybranych parametrów na zmiany wartości strat ciepła.
Źródło:
Budownictwo o Zoptymalizowanym Potencjale Energetycznym; 2013, 2 (12); 61--65
2299-8535
2544-963X
Pojawia się w:
Budownictwo o Zoptymalizowanym Potencjale Energetycznym
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Heat loss through cylindrical and spherical building partitions
Autorzy:
Brycht, Natalia
Powiązania:
https://bibliotekanauki.pl/articles/2065616.pdf
Data publikacji:
2020
Wydawca:
Politechnika Częstochowska
Tematy:
heat loss in buildings
thermal transmittance
cylindrical building partitions
spherical building partitions
straty ciepła w budynkach
przenikalność cieplna
cylindryczne przegrody budowlane
kuliste przegrody budowlane
Opis:
Heat transfer through curvilinear partitions differs, in mathematical terms, from transfer through flat ones. However, in practical calculations, an approximation is commonly used by estimating heat loss by analogy to flat partitions. There are no studies in the literature related to an exact quantitative analysis of heat loss through curvilinear partitions. The aim of the article is a comparative analysis of the computational heat loss determined for layered cylindrical and spherical partitions determined by the exact and the approximate methods. The percentage discrepancy of results was determined. Relevant computational examples were analysed. It was found that in most cases the above approximation does not lead to significant inaccuracies if the basis for calculating the heat transferring surface area is the mean radius of curvature of the partition.
Źródło:
Budownictwo o Zoptymalizowanym Potencjale Energetycznym; 2020, 9, 1; 119--126
2299-8535
2544-963X
Pojawia się w:
Budownictwo o Zoptymalizowanym Potencjale Energetycznym
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A comparative study of the performance of a low heat rejection engine with three different levels of insulation with vegetable oil operation
Studium porównawcze osiągów silnika o małych stratach ciepła, napędzanego olejem roślinnym, przy trzech różnych poziomach izolacji cieplnej
Autorzy:
Murali Krishna, M.V.S.
Janardhan, N.
Murthy, P.V.K.
Ushasri, P.
Sarada, N.
Powiązania:
https://bibliotekanauki.pl/articles/139714.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
olej lniany surowy
silnik
małe straty ciepła
moc silnika
LHR-1
LHR-2
LHR-3
poziom zanieczyszczenia
charakterystyka spalania
crude linseed oil
engine
low heat rejection
engine performance
pollution level
combustion characteristics
Opis:
Investigations were carried out to evaluate the performance of a low heat rejection (LHR) diesel engine consisting of different versions, such as ceramic coated cylinder head engine-LHR-1-Air gap insulated piston and air gap insulated liner-LHR-2- and Ceramic coated cylinder head, air gap insulated piston and air gap insulated liner -LHR-3 with degrees of insulation with normal temperature condition of linseed oil with varied injection pressure. Performance parameters were determined at various magnitudes of brake mean effective pressure. Pollution levels of smoke and oxides of nitrogen (NOx) were recorded at the peak load operation of the engine. Combustion characteristics of the engine were measured with TDC (top dead centre) encoder, pressure transducer, console and special pressure-crank angle software package. Conventional engine (CE) showed deteriorated performance, while LHR engine showed improved performance at recommended injection timing of 27 degrees bTDC and recommend injection pressure of 190 bar with vegetable oil operation, when compared with CE with pure diesel operation. Peak brake thermal efficiency increased by 14%, smoke levels decreased by 10% and NOx levels increased by 30% with LHR engine at an injection pressure of 270 bar when compared with pure diesel operation on CE at manufacturer's recommended injection timing.
Wykonano badania mające na celu ocenę osiągów silnika wysokoprężnego o małych stratach ciepła (Low Heat Rejection, LHR). Badano różne wersje izolacji cieplnej, takie jak głowica cylindra z powłoką ceramiczną (LHR-1), tłok i tuleja cylindra izolowane szczelinami powietrznymi (LHT-2), głowica cylindra z powłoką ceramiczną oraz tłok i tuleja cylindra izolowane szczelinami powietrznymi (LHR-3). Badania wykonano dla różnego stopnia izolacji, w normalnych warunkach temperaturowych, przy różnych ciśnieniach wtrysku paliwa (oleju lnianego). Parametry robocze wyznaczono dla różnych wartości ciśnienia użytecznego. Poziomy zanieczyszczeń dymem i tlenkami azotu (NOx) były mierzone w warunkach szczytowego obciążenia silnika. Przy pomiarze charakterystyk spalania silnika wykorzystano koder TDC (górnego martwego punktu), przetwornik ciśnienia, konsolę i specjalny pakiet programowy do wyznaczania zależności ciśnienie - kąt obrotu wału korbowego. Silnik konwencjonalny (CE), napędzany czystym olejem dieslowskim, wykazywał gorsze działanie. W porównaniu z nim, sinik o małych stratach ciepła (LHR), napędzany olejem roślinnym, miał lepsze parametry robocze przy zalecanym kącie wyprzedzenia wtrysku 27 stopni przed GMP i zalecanym ciśnieniu wtrysku 190 bar. Dla silnika typu LHR z optymalnym kątem wyprzedzenia wtrysku i przy maksymalnym zasysaniu etanolu, szczytowa sprawność cieplna była większa o 18%, poziom zawartości dymu mniejszy o 48%, a zawartość tlenków azotu mniejsza o 38% w porównaniu z silnikiem konwencjonalnym (CE), z czystym paliwem dieslowskim, przy zalecanym przez producenta kącie wyprzedzenia wtrysku.
Źródło:
Archive of Mechanical Engineering; 2012, LIX, 1; 101-128
0004-0738
Pojawia się w:
Archive of Mechanical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Infrared building inspection with unmanned aerial vehicles
Badania termowizyjne budynków z wykorzystaniem bezzałogowych statków lotniczych
Autorzy:
Krawczyk, J. M.
Mazur, A. M.
Sasin, T.
Stokłosa, A. W.
Powiązania:
https://bibliotekanauki.pl/articles/213328.pdf
Data publikacji:
2015
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Lotnictwa
Tematy:
energy efficiency
unmanned aerial vehicles
energy modeling
heat losses
thermal imaging
sustainable energy development
final energy consumption
building sector
efektywność energetyczna
bezzałogowe systemy latające (BSL)
modelowanie w energetyce
straty ciepła
badania termowizyjne
zrównoważony rozwój energetyczny
finalne zużycie energii
sektor budowlany
Opis:
Article discusses the subject of energy efficiency in the construction and building sector and the use of unmanned aerial vehicles in order to study energy consumption in buildings. At the beginning, the concept of energy efficiency in buildings is presented, its importance and impact on the environment. Then, the article discusses the current situation, the trends in Europe and the potentials of this sector together with the most important legal issues related to the topic of energy efficiency. The next section explores the effects of buildings on the environment, in particular, through heat loss. The article also outlines the importance of research methods and thermal imaging. Specifically developed unmanned aircraft classification is adapted for the use in thermal studies. The topic is discussed in terms of both the characteristics and structure, as well as the advantages and disadvantages of the use of such solutions. Possible paths of development in this subject are presented, as well as problems and concerns. The last part focuses on the example of the use of unmanned platform to study thermal imaging of a residential building. This is a case study carried out in December 2014.
Artykuł omawia tematykę efektywności energetycznej w budownictwie oraz wykorzystanie bezzałogowych systemów latających do badania energochłonności budynków. Na początku przedstawione jest pojęcie efektywności energetycznej w budynkach, jej znaczenie oraz wpływ na środowisko. Następnie omówiona jest obecna sytuacja, trendy w Europie oraz potencjał jakim dysponuje ten sektor wraz z najistotniejszymi kwestiami prawnymi związanymi z tematyką efektywności energetycznej. Kolejny dział przybliża nam zagadnienia wpływu budynków na środowisko, w szczególności poprzez straty ciepła. Artykuł nakreśla również sposoby oraz znaczenie badań termowizyjnych. Szczegółowo opracowana jest klasyfikacja samolotów bezzałogowych przystosowanych do wykorzystania w badaniach termowizyjnych. Temat omówiony jest zarówno pod kątem charakterystyki i konstrukcji, jak również wad i zalet stosowania takich rozwiązań. Analizowane są również obecne ścieżki rozwoju w tej tematyce, problemy i wątpliwości. Ostatnia część skupia się na przykładzie wykorzystania platformy bezzałogowej do badania termowizyjnego budynku mieszkalnego. Jest to studium przypadku wykonane w Grudniu 2014 roku.
Źródło:
Prace Instytutu Lotnictwa; 2015, 3 (240); 32-48
0509-6669
2300-5408
Pojawia się w:
Prace Instytutu Lotnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A study on power losses of the 50 kVA SiC converter including reverse conduction phenomenon
Autorzy:
Rąbkowski, J.
Płatek, T.
Powiązania:
https://bibliotekanauki.pl/articles/201547.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
power losses
three-phase converter
MOSFET
Schottky diode
reverse conduction
straty mocy
konwerter trójfazowy
dioda Schottky'ego
odwrotne przewodzenie ciepła
Opis:
This paper deals with performance of the 50 kVA three-phase converter built with switches based on SiC MOSFET and anti-parallel Schottky diodes. In contrast to popular IGBT converters, a negative switch current is capable of flowing through the reverse conducting transistor, which results in different distribution of power losses among the devices. Thus, equations describing the conduction power losses of the transistor and diode are improved and verified by means of circuit simulations in Saber. Moreover, a comparison of power losses calculated with the use of standard and new equations is also shown. Total power losses in three SiC MOSFET modules of a 50 kVA converter operating at 20 kHz are up to 30% lower when reverse conduction is taken into account. This shows the importance of the discussed problem and proves that much better accuracy in the estimation of power losses and junction temperatures of SiC devices may be obtained with the proposed approach.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2016, 64, 4; 907-914
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Thermodynamical motivation of the Polish energy policy
Autorzy:
Ziębik, A.
Powiązania:
https://bibliotekanauki.pl/articles/240888.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
efektywność energetyczna
egzergia
kogeneracja
koszt termoekologiczny
odzysk ciepła
polityka energetyczna
straty egzergii
cogeneration
energy effectiveness
energy policy
exergy
exergy losses
thermoecological cost
Waste-heat recovery
Opis:
Basing on the first and second law of thermodynamics the fundamental trends in the Polish energy policy are analysed, including the aspects of environmental protection. The thermodynamical improvement of real processes (reduction of exergy losses) is the main way leading to an improvement of the effectivity of energy consumption. If the exergy loss is economically not justified, we have to do with an error from the viewpoint of the second law analysis. The paper contains a thermodynamical analysis of the ratio of final and primary energy, as well as the analysis of the thermo-ecological cost and index of sustainable development concerning primary energy. Analyses of thermo-ecological costs concerning electricity and centralized heat production have been also carried out. The effect of increasing the share of high-efficiency cogeneration has been analyzed, too. Attention has been paid to an improved efficiency of the transmission and distribution of electricity, which is of special importance from the viewpoint of the second law analysis. The improvement of the energy effectivity in industry was analyzed on the example of physical recuperation, being of special importance from the point of view of exergy analysis.
Źródło:
Archives of Thermodynamics; 2012, 33, 4; 3-21
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-9 z 9

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies