Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "stezenie tlenu" wg kryterium: Temat


Wyświetlanie 1-3 z 3
Tytuł:
Changes in the structure of activated sludge protozoa community at the different oxygen condition
Zmiany w strukturze zbiorowiska pierwotniaków osadu czynnego w zróżnicowanych warunkach tlenowych
Autorzy:
Babko, R.
Kuzmina, T.
Łagód, G.
Jaromin-Gleń, K.
Powiązania:
https://bibliotekanauki.pl/articles/106354.pdf
Data publikacji:
2014
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
SBR bioreactor
activated sludge
community
protozoa
wastewater purification
oxygen concentration
bioreaktor typu SBR
osad czynny
zespół organizmów
pierwotniaki
oczyszczanie ścieków
stężenie tlenu
Opis:
Several experiments were performed in the laboratory condition using an SBR bioreactor modelling the expected conditions, created by malfunction of certain bioreactor elements, thus the different oxygen condition. In the course of the experiments, the concentrations of ammonia nitrogen, nitrates(III), nitrates(V), TOC, and TC were systematically measured. Besides physico-chemical parameters, the structure of activated sludge community was analyzed. In the samples, the number and species composition of protozoa (ciliates) were determined. Each of the three measuring series conducted for various types of process conditions was repeated three times. The activated sludge used for inoculation of the bioreactor was sampled at Hajdow WWTP in Lublin. The results obtained are the average of three repetitions of every experimental series. On this ground, we may conclude that the number of ciliates shows a high correlation with the O2 concentration, pH and TOC.
W pracy przedstawiono wyniki badań prowadzonych w laboratoryjnym bioreaktorze SBR, symulującym warunki występujące w przypadku awarii urządzeń stanowiących wyposażenie bioreaktora (systemu mieszania i systemu napowietrzania). Analizowano skład chemiczny ścieków, w tym stężenia związków azotu (azot amonowy, azotany(III) i azotany(V)), a także stężenia związków organicznych wyrażanych jako ogólny węgiel organiczny (OWO) i węgiel całkowity. Oprócz wskaźników chemicznych analizowany był również zespół organizmów osadu czynnego. W pobieranych próbkach określano ilość pierwotniaków (orzęski) w wymienionej grupie. Każdą z trzech serii pomiarowych prowadzonych dla różnych warunków procesowych powtarzano trzykrotnie. W eksperymencie wykorzystano osad czynny pobierany z oczyszczalni ścieków Hajdów w Lublinie. Na podstawie uzyskanych wyników badań można stwierdzić, że liczebności analizowanych zbiorowisk orzęsków wykazują związek ze stężeniem tlenu, pH oraz wartością OWO.
Źródło:
Chemistry-Didactics-Ecology-Metrology; 2014, 19, 1-2; 87-95
2084-4506
Pojawia się w:
Chemistry-Didactics-Ecology-Metrology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Errors Associated With Excess Air Multipoint Measurement Systems
Autorzy:
Ramsunkar, C.
Tonder, C. von
Schmitz, W.
Powiązania:
https://bibliotekanauki.pl/articles/184927.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
excess air measurement
flue gas oxygen concentration
boiler O2
air ingress
nadmiar pomiaru powietrza
stężenie tlenu spaliny
kocioł O2
wnikanie powietrza
Opis:
Boiler combustion air is generally controlled by the excess air content measured at the boiler economiser outlet using oxygen (O2) analysers. Due to duct geometry and dimensions, areas of high and low O2 concentrations in the flue gas duct occur, which poses a problem in obtaining a representative measurement of O2 in the flue gas stream. Multipoint systems as opposed to single point systems are more favourable to achieve representative readings. However, ash blockages and air leakages influence the accuracy of O2 measurement. The design of multipoint system varies across ESKOMs’ Power Stations. This research was aimed at evaluating the accuracy of the multipoint oxygen measurement system installed at Power Station A and to determine the systematic errors associated with different multipoint systems designs installed at Power Stations' A and B. Using flow simulation software, FloEFDTM and Flownex®, studies were conducted on two types of multipoint system designs This study established that significantly large errors, as high as 50%, were noted between the actual and measured flue gas O2. The design of the multipoint system extraction pipes also introduces sigdnificant errors, as high as 23%, in the O2 measured. The results indicated that the sampling errors intro- introduced with Lethabo's system can be significantly reduced by adopting the sampling pipe design installed at Camden.
Źródło:
Chemical and Process Engineering; 2015, 36, 4; 405--423
0208-6425
2300-1925
Pojawia się w:
Chemical and Process Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Biological nutrient removal using a novel five-step continuous flow activated sludge process technology
Autorzy:
Abualhai, S.
Naseer, R.
Xiwu, L.
Powiązania:
https://bibliotekanauki.pl/articles/208183.pdf
Data publikacji:
2013
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
nitrogen removal
activated sludge process
chemical oxygen demand
sewage
nutrient removal
biological processes
nutrient concentrations
usuwanie azotu
chemiczne zapotrzebowanie tlenu
ścieki
biologiczne usuwanie składników odżywczych
proces biologiczny
stężenie substancji odżywczych
metoda osadu czynnego
proces osadu czynnego
Opis:
An anaerobic-anoxic/oxic (AA/O) five-tank biological process called five-step continuous flow activated sludge process (FSCFASP) was developed to force the oscillation of organic matter and nutrient concentrations in process reactors. The run scheme and schematic diagram of FSCFASP was described. The run cycle was divided into two symmetrical half cycles with eight periods during each cycle. The duration of each period was established according to biological process requirements. The optimal running times of the periods were 90, 60, 60, 30, 90, 60,6 0 and 30 min at the HRT of 16 h, air/water ratio of 35% and SRT of 21 day at the temperature range of 19-23 °C. The optimized system achieved 88.09±1.43%, 90.33±2.9%, 68.83±5.34% and 87.67±2.9% of the chemical oxygen demand, NH4+-N, TN, and TP removal efficiencies, respectively, during a 11-month operation with the effluent meeting the Chinese sewage discharge standard GB18918-2002 (level A). Simultaneous nitrification and denitrification phenomena were observed in the tank one which is important to reduce the quantity of aeration and the duration of a next anoxic state. Compared with other existing technologies, this system achieved high nitrogen and phosphorus removal without equipment of sludge and mixed liquor return. Thus, it is effective for reducing energy consumption.
Źródło:
Environment Protection Engineering; 2013, 39, 3; 165-184
0324-8828
Pojawia się w:
Environment Protection Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-3 z 3

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies