Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "steam power unit" wg kryterium: Temat


Wyświetlanie 1-4 z 4
Tytuł:
Analysis of fouling thermal resistance of feed-water heaters in steam power plants
Autorzy:
Butrymowicz, D.
Głuch, J.
Hajduk, T
Trela, M.
Gardzilewicz, A.
Powiązania:
https://bibliotekanauki.pl/articles/259063.pdf
Data publikacji:
2009
Wydawca:
Politechnika Gdańska. Wydział Inżynierii Mechanicznej i Okrętownictwa
Tematy:
steam power unit
fouling
feedwater heaters
Opis:
In this paper a problem is discussed of thermal degradation of shell-and-tube recuperative feed-water heaters due to heat transfer surface fouling. Application (to an example steam cycle of power plant) of DIAGAR software system intended for the analysing of impact of degradation of a particular heat exchanger on whole recuperative system performance, is presented. On the basis of the systematically performed simulative calculations it was concluded that the degradation of feed-water heaters of the lowest extraction pressure results in an additional load imposed on the heaters of higher extraction pressures, moreover it was estimated that the degradation of the heaters due to presence of sediments of the thermal resistance reaching 5*10-4 m2*K/W, has resulted in the drop of turbine set efficiency by about 0.3%. Such drop depends on a given configuration of degree of degradation of particular feed-water heaters applied in a considered turbine set.
Źródło:
Polish Maritime Research; 2009, S 1; 3-8
1233-2585
Pojawia się w:
Polish Maritime Research
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Thermodynamic and economic analysis of a 900 MW ultra-supercritical power unit
Autorzy:
Łukowicz, H.
Dykas, S.
Rulik, S.
Stępczyńska, K.
Powiązania:
https://bibliotekanauki.pl/articles/240644.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
obieg pary
parametry apry
podwójne podgrzewanie
coal-fired power unit
double reheat
steam cycle
ultra-supercritical steam parameters
Opis:
The paper presents a thermal-economic analysis of different variants of a hard coal-fired 900 MW ultra-supercritical power unit. The aim of the study was to determine the effect of the parameters of live and reheated steam on the basic thermodynamic and economic indices of the thermal cycle. The subject of the study was the cycle configuration proposed as the "initial thermal cycle structure" during the completion of the project "Advanced Technologies for Energy Generation" with the live and reheated steam parameters of 650/670 [degrees]C. At the same time, a new concept of a thermal cycle for ultra-supercritical parameters with live and reheated steam temperature of 700/720 [degrees]C was suggested. The analysis of the ultra-supercritical unit concerned a variant with a single and double steam reheat. All solutions presented in the paper were subject to a detailed thermodynamic analysis, as well as an economic one which also included CO2 emissions charges. The conducted economic analysis made it possible to determine the maximum value of investment expenditures at which given solutions are pro.table.
Źródło:
Archives of Thermodynamics; 2011, 32, 3; 231-245
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Improving flexibility characteristics of 200 MW unit
Autorzy:
Taler, J.
Trojan, M.
Taler, D.
Dzierwa, P.
Kaczmarski, K.
Powiązania:
https://bibliotekanauki.pl/articles/239919.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
thermal power unit
flexibility increasing
steam boiler
rapid start-up
elektrownia cieplna
elastyczność
kocioł parowy
szybkie uruchamianie
Opis:
Calculations were performed of the thermal system of a power plant with installed water pressure tanks. The maximum rise in the block electric power resulting from the shut-off of low-pressure regenerative heaters is determined. At that time, the boiler is fed with hot water from water pressure tanks acting as heat accumulators. Accumulation of hot water in water tanks is also proposed in the periods of the power unit small load. In order to lower the plant electric power in the off-peak night hours, water heated in low-pressure regenerative heaters and feed water tank to the nominal temperature is directed to water pressure tanks. The water accumulated during the night is used to feed the boiler during the period of peak demand for electricity. Drops in the power block electric power were determined for different capacities of the tanks and periods when they are charged. A financial and economic profitability analysis (of costs and benefits) is made of the use of tanks for a 200 MW power unit. Operating in the automatic system of frequency and power control, the tanks may also be used to ensure a sudden increase in the electric power of the unit. The results of the performed calculations and analyses indicate that installation of water pressure tanks is well justified. The investment is profitable. Water pressure tanks may not only be used to reduce the power unit power during the off-peak night hours and raise it in the periods of peak demand, but also to increase the power capacity fast at any time. They may also be used to fill the boiler evaporator with hot water during the power unit start-up from the cold state.
Źródło:
Archives of Thermodynamics; 2017, 38, 1; 75-90
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Performance Analysis of Power Boiler Drum Water Level Control Systems
Analiza pracy układów regulacji poziomu wody w walczaku kotła energetycznego
Autorzy:
Pawlak, M.
Powiązania:
https://bibliotekanauki.pl/articles/397604.pdf
Data publikacji:
2016
Wydawca:
ENERGA
Tematy:
control system
steam boiler
power unit
level control
drum
drum model
układ regulacji
kocioł parowy
blok energetyczny
regulacja poziomu
walczak
model walczaka
Opis:
Described in the paper are the structures of water level controls in power boiler drums. A boiler drum’s function is very important for the power unit process, because this is where water separates from steam, which is then superheated and supplied to the turbine. A boiler drum’s dynamic properties as an object of regulation have been listed. The model has been identified on the basis of measurement data from a real object. In the described system the control and measurement devices’ working conditions are difficult due to high temperature and pressure. Incorrect operation of the control system could lead to a major accident. A performance analysis has been presented of three controller level structures, to ensure the system’s stable operation.
Opisano struktury stosowanych regulatorów poziomu wody w walczaku kotła energetycznego. Walczak pełni bardzo odpowiedzialne funkcje w procesie technologicznym bloku energetycznego, ponieważ zachodzi tutaj proces oddzielania wody od pary, która po przegrzaniu jest doprowadzana do turbiny. Przedstawiono właściwości dynamiczne walczaka jako obiektu regulacji. Przeprowadzono identyfikację modelu na podstawie danych pomiarowych z rzeczywistego obiektu. W opisywanym układzie warunki pracy urządzeń regulacyjnych i pomiarowych są trudne ze względu na wysoką temperaturę i ciśnienie. Niepoprawna praca układu regulacji może doprowadzić do poważnej awarii. Zaprezentowano analizę pracy trzech struktur regulatora poziomu w celu zapewnienia stabilnej pracy układu.
Źródło:
Acta Energetica; 2016, 4; 81-89
2300-3022
Pojawia się w:
Acta Energetica
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-4 z 4

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies