Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "solar collector flat-plate" wg kryterium: Temat


Wyświetlanie 1-6 z 6
Tytuł:
Effect of Nanoparticles on the Performance of Solar Flat Plate Collectors
Autorzy:
Hamdan, M.
Sarsour, M.
Powiązania:
https://bibliotekanauki.pl/articles/124517.pdf
Data publikacji:
2018
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
solar energy
nanoparticles
solar flat plate collector
Opis:
Solar energy constitutes superior renewable source due to its availability, natural distribution and no necessity for transportation. It can be designed to fulfill the requirements of power demands, and can work in synchronization with battery banks and diesel generators or any other power source to provide a continuous and stable power. Solar energy is already one of the best solutions to fulfill power demands. A solar thermal collector is a key element for the collection and conversion of solar energy into thermal energy. There are different types of solar collectors, the most important one is the conventional 'Flat-Plate' kind, which absorbs the incident radiation and converts it to thermal energy. The main objective of this work is to study the effect of Titanium Oxide (TiO2) and Zinc Oxide (ZnO) water-based nanofluids on the performance of solar flat plate collector. In order to achieve this objective, three identical flat plat solar collectors were used with appropriate instrumentations necessary to experimentally calculate their performance. The working fluid in the first collector was pure water, while in the second collector, it was Titanium Oxide water-based nanofluid and in the third one – Zinc Oxide water-based nanofluid. Two different values of volume fraction of both oxides were used as well. It was found that the addition of Titanium Oxide and Zinc Oxide nanoparticles leads to an increase in the efficiency of the solar collector. The efficiency of the collector was found to be maximum over all values of (Tin – Tamb) when a 0.2% volume fraction of Titanium Oxide was used with a maximum efficiency of 40%, followed by the case of 0.6% volume fraction of Titanium Oxide. Furthermore, zinc oxide caused a maximum improvement in the performance of solar flat plate collector when 0.6% was used, followed by 0.2% concentration. Finally, it was found that titanium oxide is characterized by more pronounced improvement in the performance of solar flat plate collector.
Źródło:
Journal of Ecological Engineering; 2018, 19, 2; 1-7
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Enhancement of thermal efficiency of nanofluid flows in a flat solar collector using CFD
Autorzy:
Zarda, Falah
Hussein, Adnan Mohammed
Danook, Suad H.
Mohamad, Barhm
Powiązania:
https://bibliotekanauki.pl/articles/2146747.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Polskie Towarzystwo Diagnostyki Technicznej PAN
Tematy:
solar collector flat-plate
diamond/H2O nanofluids
thermal performance
computational fluid dynamics
płaski kolektor słoneczny
właściwości cieplne
numeryczna mechanika płynów
Opis:
Flat plate solar collector (FPSC) is popular for their low cost, simplicity, and ease of installation and operation. In this work, FPSC thermal performance was analyzed. It's compared to diamond/H2O nanofluids. The volume percentage and kind of nanoparticles are analyzed numerically that validation with experimental data available in the literature. The hot climate of Iraq is employed to approximate the model. The numerical study is performed by using ANSYS/FLUENT software to simulate the case study of problem. Due to less solar intensity after midday, temperatures reduction. The greatest collector thermal efficiency is 68.90% with 1% ND/water nanofluid, a 12.2% increase over pure water. The efficiency of 1% nanofluid is better than other concentrations because of a change in physical properties and an increase in thermal conductivity. Since the intensity of radiation affects the outlet temperature from the solar collector and there is a direct link between them, this increases the efficiency of the solar collector, especially around 12:30 pm at the optimum efficiency.
Źródło:
Diagnostyka; 2022, 23, 4; art. no. 2022411
1641-6414
2449-5220
Pojawia się w:
Diagnostyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Solar Hot Water Heating and Electricity Generation Using PV/T Hybrid System
Autorzy:
Badran, Ali A.
Obeidat, Firas A.
Powiązania:
https://bibliotekanauki.pl/articles/2086426.pdf
Data publikacji:
2022
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
solar energy system
water heating system
PV module
flat plate solar collector
Opis:
Experimental work has been carried out to study the possibility of combining a conventional solar water collector with a hybrid device, developed previously and known as PV/T system, in order to obtain hot water with temperature above 40 °C. The effect of the combination on the productivity of hot water and the produced electricity was found. The formerly developed device, in which there was a multi-purpose solar collector, can produce hot water and electricity. It was connected to the conventional fin-tube collector in series in order to raise the product temperature to a higher level. This development was achieved for the first time as a combination between a PV/T and a conventional fin-tube collector. Instrumentation to measure temperatures, solar radiation, wind speed and flow rate was installed on the system. It was found that the water temperature was raised from 29 °C to 32 °C in the PV/T collector system and, after flowing through the conventional collector, it was raised to 50 °C and above. It was also found that the power efficiency in the case of water flow is always higher than in the case of no water flow.
Źródło:
Journal of Ecological Engineering; 2022, 23, 5; 196--206
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of Flow and Thermal Phenomena In Evacuated Tube Collectors
Autorzy:
Demianiuk, A.
Sorko, S. A.
Powiązania:
https://bibliotekanauki.pl/articles/386625.pdf
Data publikacji:
2012
Wydawca:
Politechnika Białostocka. Oficyna Wydawnicza Politechniki Białostockiej
Tematy:
kolektor słoneczny
przepływ ciepła
przepływ cieczy
flat plate solar collector
heat transfer
fluid flow in pipes
optimum mass flow rate
boundary equation method
Opis:
The subject of this case study is an issue of optimisation of flat tube solar collectors. Basic elements of energy analysis of performance parameters described by Hottel-Whillier equation are presented in the article. It is considered to be crucial to precisely analyse fluid flow through flow elements in evacuated tube collectors. It is especially important in the case of systems with channels of cross sections shapes different from circular and for the use of detailed mathematical description of complex film conduction phenomena. It is presented that the advanced analysis of the flow and thermal phenomena in complex heat transfer systems, represented by evacuated tube collectors, enables engineering rationalisation of technical solutions for these devices.
Źródło:
Acta Mechanica et Automatica; 2012, 6, 4; 5-10
1898-4088
2300-5319
Pojawia się w:
Acta Mechanica et Automatica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The comparison of solar installation heat gains and SHW simulation results – case study
Porównanie uzysków ciepła z instalacji solarnej z symulacją – studium przypadku
Autorzy:
Olczak, Piotr
Powiązania:
https://bibliotekanauki.pl/articles/283196.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Instytut Gospodarki Surowcami Mineralnymi i Energią PAN
Tematy:
simulation
renewable energy
solar energy
flat plate collector
solar thermal
symulacje
energia słoneczna
OZE
płaski kolektor słoneczny
ciepło solarne
Opis:
In Poland an increase in the of number solar thermal collectors is observed in household applications. For economic and ecological profitability the creation of a solar thermal installation design in a proper manner is essential. In order to determine solar installations size, software calculating future solar heat gains is used. SHW software is an examples of such software. The aim of this work was to compare the simulation results with the real results of the solar installation operation. The comparison was performed by an example of a single-family house with flat plate collector installations located in south-east Poland. This installation supports domestic hot water preparation in a house occupied by four people (in two-year period of analyses). The additional heat source in this building is a gas boiler. Solar fraction parameter values were chosen for this comparison. Solar fraction is calculated as a ratio of solar heat gains used in the domestic hot water preparation process to the heat desired for domestic hot water preparation. The real results of Solar Fraction turned out to be higher than the simulation results from May to August (there were many days with Solar Fraction = 1). A difference of 20–50 percentage points was observed (Solar Fraction). Apart from this period no special differences were observed. Additionally analyses of differences between solar heat gains calculated by Get Solar simulation software with real values (for analyzed building) was performed. This simulation analysis was done before process of building installations.
W Polsce obserwuje się wzrost liczby kolektorów słonecznych w zastosowaniach domowych. Dla opłacalności ekonomicznej i ekologicznej ważne jest właściwe zaprojektowanie instalacji solarnej. W celu ustalenia wielkości instalacji słonecznych stosuje się oprogramowanie do obliczania przyszłych zysków ciepła słonecznego. Program SHW jest jednym z przykładów takiego oprogramowania.Celem pracy było porównanie wyników symulacji z rzeczywistymi wynikami pracy instalacji solarnej. Porównanie przeprowadzono na przykładzie domu jednorodzinnego (z instalacją płaskich kolektorów słonecznych) położonego w południowo-wschodniej Polsce. Instalacja solarna obsługuje przygotowywanie ciepłej wody użytkowej w domu zamieszkanym przez cztery osoby (w dwuletnim okresie analizy). Dodatkowym źródłem ciepła w tym budynku jest kocioł gazowy. Do porównania wybrano wartości parametru Solar Fraction. Solar Fraction jest obliczany jako stosunek zysków ciepła słonecznego wykorzystywanych w procesie przygotowania ciepłej wody użytkowej do ciepła pożądanego do przygotowania ciepłej wody użytkowej. Rzeczywiste wyniki frakcji słonecznej (w skali miesięcznej) okazały się wyższe od wyników symulacji w okresie od maja do sierpnia (było wiele dni z Solar Fraction = 1). Maksymalna różnica wyniosła 20–50 punktów procentowych (Solar Fraction). Oprócz tego okresu nie zaobserwowano żadnych szczególnych różnic. Dodatkowo przeprowadzono analizę osiągniętych różnic między zyskami ciepła słonecznego obliczonymi przez oprogramowanie symulacyjne Get Solar a wartościami rzeczywistymi (dla analizowanego budynku). Symulacja ta została wykonana przed procesem budowy instalacji.
Źródło:
Polityka Energetyczna; 2020, 23, 3; 41-54
1429-6675
Pojawia się w:
Polityka Energetyczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The influence of excessive solar heat gains on heat loss in the hot water tank – case study
Wpływ nadmiernych uzysków solarnych na straty ciepła z zasobnika cwu – studium przypadku
Autorzy:
Olczak, Piotr
Powiązania:
https://bibliotekanauki.pl/articles/282991.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Instytut Gospodarki Surowcami Mineralnymi i Energią PAN
Tematy:
renewable energy
solar energy
flat plate collector
hot water tank
tank loss coefficient
energia słoneczna
energia odnawialna
płaski kolektor słoneczny
zasobnik ciepłej wody
współczynnik strat ciepła z zasobnika
Opis:
The analysis of a solar installation operation was conducted on the example of a detached house in the Lesser Poland province in Poland. A gas boiler and three flat-plate collectors are located inside the house, which are used for heating water in the hot water tank with a volume of 220 dm3. The installation was established in 2012. The heat measured system (for solar gains) was added in 2014. In 2015–2019 solar heat gains measured per area of absorber were higher than 340 kWh/m2. During a two-week period in June 2015, the insolation on the horizontal plane and the temperature were measured in 4 different points of the hot water tank. On this basis, heat losses from the storage tank were determined, i.e. a decrease in temperature during periods with and without the consumption of hot water by the residents. During this period, a temperature higher than 80°C was observed several times in the hot water tank. In two parts of the hot water tank, rhe determined temperature decreases were used to obtain the heat loss amount. In the analyzed period (2 weeks), 9 days were observed with solar heat gains higher than 9 kWh/day. For these days, the value of heat loss from the solar hot water tank was estimated at over 6 kWh/day. This data corresponds to the actual heat demand for hot water preparation in the building at 7.3 kWh/day. The correlation between daily solar heat gains and solar hot water tank heat losses were also determined. In addition, based on the amount of heat losses, the value of the tank loss coefficient was estimated. The obtained value was compared with the manufacturer’s data and reference data.
Analiza aspektów pracy instalacji solarnej została przeprowadzona na przykładzie domu jednorodzinnego w województwie małopolskim w Polsce. W analizowanym budynku jednorodzinnym znajduje się kocioł gazowy i instalacja solarna złożona z trzech płaskich kolektorów słonecznych. Urządzenia te odpowiadają za przygotowanie ciepłej wody użytkowej magazynowanej w zasobniku o pojemności 210 dm3. Instalacja powstała w 2012 roku, w 2014 roku została opomiarowana pod kątem uzysków solarnych. W latach 2015–2019 mierzono uzyski solarne, były one wyższe niż 340 kWh/m2 powierzchni absorbera. Podczas dwutygodniowego okresu w czerwcu 2015 roku mierzono także natężenie promieniowania słonecznego na płaszczyźnie poziomej i temperaturę w 4 różnych punktach zasobnika ciepłej wody. Na tej podstawie określono straty ciepła z zasobnika, tj. spadek temperatury w zasobniku w okresach z i bez poboru ciepłej wody użytkowej przez mieszkańców. W tym okresie zanotowano temperaturę wyższą niż 80°C w zasobniku tylko przez kilka stosunkowo krótkich okresów. Wyznaczone spadki temperatury w dwóch częściach zasobnika ciepłej wody użytkowej użyto do określenia ilościowych strat ciepła. W analizowanym okresie (2 tygodnie) zaobserwowano 9 dni z uzyskami solarnymi wyższymi niż 9 kWh/dzień. Dla tych dni oszacowano wartości strat ciepła z zasobnika na poziomie powyżej 6 kWh/dzień. Dane te korespondują z rzeczywistym zapotrzebowaniem na ciepło do przygotowania ciepłej wody użytkowej w budynku na poziomie 7,3 kWh/dzień. Określono także zależności między dziennymi uzyskami solarnymi a stratami ciepła z zasobnika (korelacja). Ponadto bazując na wielkościowych stratach ciepła, oszacowano wielkość współczynnika strat ciepła z zasobnika. Uzyskaną wartość porównano z danymi producenta i danymi referencyjnymi.
Źródło:
Polityka Energetyczna; 2020, 23, 2; 91-103
1429-6675
Pojawia się w:
Polityka Energetyczna
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-6 z 6

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies