Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "scattering angle" wg kryterium: Temat


Wyświetlanie 1-4 z 4
Tytuł:
Particle localization via measurement induced entanglement
Autorzy:
Vasura Jayaweera, K. K. Y.
Wijewardena Gamalath, K. A. I. L.
Powiązania:
https://bibliotekanauki.pl/articles/1059506.pdf
Data publikacji:
2019
Wydawca:
Przedsiębiorstwo Wydawnictw Naukowych Darwin / Scientific Publishing House DARWIN
Tematy:
Fluffy-Bunny entanglement
Quantum entanglement
photons
position probability density
relative position
scattering angle
spatial localization
variance
Opis:
To explore the boundary between quantum and classical physics in the context of quantum entanglement, the particle localization via measurement induced entanglement on photons incident onto a distinguishable, massive non-interacting two-particle system was studied. The specific case of how particles acquire well defined spatial localization when light is scattered off and detected was considered. The localization process studied both qualitatively and quantitatively was observed to be valid for particles which were initially localized as well as initially completely delocalized. The localization scheme was also observed to be extremely sensitive to its initial conditions. Furthermore, a difference in the localization scheme in terms of the number of scattering events was observed between monochromatic photons and photons with variable frequencies. From all these results it was apparent that we can interpret the uniquely quantum features of entanglement in terms of classicality.
Źródło:
World Scientific News; 2019, 128, 2; 234-254
2392-2192
Pojawia się w:
World Scientific News
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A comparison between the crystal and solution structures of Escherichia coli asparaginase II.
Autorzy:
Kozak, Maciej
Jurga, Stefan
Powiązania:
https://bibliotekanauki.pl/articles/1043790.pdf
Data publikacji:
2002
Wydawca:
Polskie Towarzystwo Biochemiczne
Tematy:
structure in solution
small angle X-ray scattering
asparaginase
Opis:
The small angle X-ray scattering (SAXS) pattern of the homotetrameric asparaginase II from Escherichia coli was measured in solution in conditions resembling those in which its crystal form was obtained and compared with that calculated from the crystallographic model. The radius of gyration measured by SAXS is about 5% larger and the maximum dimension in the distance distribution function about 12% larger than the corresponding value calculated from the crystal structure. A comparison of the experimental and calculated distance distribution functions suggests that the overall quaternary structure in the crystal and in solution are similar but that the homotetramer is less compact in solution than in the crystal.
Źródło:
Acta Biochimica Polonica; 2002, 49, 2; 509-513
0001-527X
Pojawia się w:
Acta Biochimica Polonica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Biochemical and structural studies of plant circadian clock proteins
Autorzy:
Saini, R.
Szpotkowski, K.
Kozak, M.
Jaskolski, M.
Davis, S.J.
Powiązania:
https://bibliotekanauki.pl/articles/80840.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
circadian clock
diurnal change
plant circadian clock
protein
multiple feedback loop
crystallization
recombinant fusion protein
early flowering
small angle X-ray scattering
protein-protein interaction
biochemical study
structural study
Źródło:
BioTechnologia. Journal of Biotechnology Computational Biology and Bionanotechnology; 2013, 94, 1
0860-7796
Pojawia się w:
BioTechnologia. Journal of Biotechnology Computational Biology and Bionanotechnology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Orienting cylindrical microdomains in polystyrene-b-poly(ethylene-co-butylene)-b-polystyrene triblock copolymer/diluent sheet by application of temperature gradient
Orientowanie cylindrycznych mikrodomen w kompozycjach trójblokowego kopolimeru polistyren-b-poli(etylen-co-butylen)-b-polistyren z rozcieńczalnikiem za pomocą gradientu temperatury
Autorzy:
Yamanaka, R.
Shimizu, N.
Igarashi, N.
Takagi, H.
Sakurai, S.
Powiązania:
https://bibliotekanauki.pl/articles/946944.pdf
Data publikacji:
2017
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Chemii Przemysłowej
Tematy:
polystyrene-b-poly(ethylene-co-butylene)-b-polystyrene triblock copolymer
diluent
cylindrical microdomains
perpendicular orientation
temperature gradient
small-angle X-ray scattering
kopolimer polistyren-b-poli(etylen-co-butylen)-b-polistyren
rozcieńczalnik
cylindryczne mikrodomeny
orientacja prostopadła
gradient temperatury
metoda rozpraszania promieni rentgenowskich pod małymi kątami
Opis:
The cylinder-forming polystyrene-b-poly(ethylene-co-butylene)-b-polystyrene (SEBS) triblock copolymer with a volume fraction of polystyrene (PS) equal to 0.16 was investigated. The orientation of cylindrical microdomains in SEBS/diluent sheet by application of temperature gradient were studied using small-angle X-ray scattering (SAXS). Dioctyl phthalate (DOP) was used as a diluent, which selectively dissolves SEBS, being a good solvent for PS but a poor solvent for poly(ethylene-co-butylene) (PEB). Due to this selectivity, a lamellar morphology was found at lower temperature (Tcold) for specimens with SEBS/DOP ratio of 6/4 and 7/3. It was further revealed that the morphology changed to be cylindrical at higher temperature (Thot). The order-order transition temperature (TOOT) was found to be 100 °C for both compositions, although a coexistence of lamellae and cylinders in a much wider temperature range was observed for the composition with SEBS/DOP = 7/3 as compared to the composition with SEBS/DOP = 6/4. These results indicate that the diluent selectivity of solubility at lower temperatures is suppressed at higher temperatures. For the specimen with SEBS/DOP = 6/4 the order-disorder transition temperature (TODT) was found to be 152.0 °C. The cylindrical morphology was found near the cold wall of the sample holder, even though the lamellar phase should be stable because the cold temperature was below TOOT. This result implies that the temperature gradient may destabilize the lamellar phase. The cylinders in the confined space under the temperature gradient are considered to accommodate well. Both of the spacing and the cylinder radius was found to be larger as the position of the specimen irradiated by the incident X-ray beam was closer to the cold sidewall of the temperature gradient sample cell.
Do badań użyto kopolimeru blokowego polistyren-b-poli(etylen-co-butylen)-b-polistyren (SEBS), w którym ułamek objętościowy polistyrenu (PS) wynosił 0,16. Metodą rozpraszania promieni rentgenowskich pod małymi kątami (SAXS) oceniano zmiany orientacji cylindrycznych mikrodomen w kompozycjach SEBS/rozcieńczalnik po zastosowaniu gradientu temperatury. Jako rozcieńczalnik stosowano ftalan dioktylu (DOP), który wykazuje selektywność rozpuszczania SEBS – dobra rozpuszczalność PS, a słaba poli(etylenu-co-butylenu) (PEB). Z powodu tej selektywności, w przypadku próbek o stosunku SEBS/DOP wynoszącym 6/4 i 7/3, w niższej temperaturze (Tcold) stwierdzono morfologię lamelarną. Stwierdzono też, że w wyższej temperaturze (Thot) morfologia zmieniała się w cylindryczną. Temperatura przemiany porządek-porządek (TOOT) w obu kompozycjach wynosiła 100°C, chociaż współistnienie lameli i cylindrów w znacznie szerszym zakresie temperatury stwierdzono w przypadku kompozycji SEBS/DOP = 7/3 w porównaniu z kompozycją SEBS/DOP = 6/4. Wyniki te wskazują, że w wyższej temperaturze selektywność rozpuszczania jest stłumiona. Stwierdzono też, że w próbce SEBS/DOP = 6/4 temperatura przemiany porządek-nieporządek (TODT) wynosi 152,0 °C. W pobliżu zimnej ściany uchwytu próbki, której temperatura była niższa niż TOOT, zaobserwowano morfologię cylindryczną, chociaż spodziewano się stabilnej fazy lamelarnej. Oznacza to, że gradient temperatury może destabilizować fazę lamelarną. Uważa się, że w ograniczonej przestrzeni w warunkach gradientu temperatury lepsze dopasowanie jest możliwe w przypadku cylindrów. W miarę obniżania temperatury zarówno rozstaw, jak i promienie cylindrów stają się większe.
Źródło:
Polimery; 2017, 62, 11-12; 812-820
0032-2725
Pojawia się w:
Polimery
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-4 z 4

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies