Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "pulse wave" wg kryterium: Temat


Wyświetlanie 1-7 z 7
Tytuł:
Rapid Synthesis of Gold Nano-Particles Using Pulse Waved Potential in a Non-Aqueous Electrolyte
Autorzy:
Jang, J. G.
Lee, J.-O.
Lee, C. K.
Powiązania:
https://bibliotekanauki.pl/articles/352529.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
gold
nanoparticle
nonaqueous electrolyte
pulse wave
catalyst
Opis:
Rapid synthesis of gold nanoparticles (AuNPs) by pulsed electrodeposition was investigated in the non-aqueous electrolyte, 1-ethyl-3-methyl-imidazoliumbis(trifluoro- methanesulfonyl)imide ([EMIM]TFSI) with gold trichloride (AuCl3). To aid the dissolution of AuCl3, 1-ethyl-3-methyl-imidazolium chloride ([EMIM]Cl) was used as a supporting electrolyte in [EMIM]TFSI. Cyclicvoltammetry experiments revealed a cathodic reaction corresponding to the reduction of gold at −0.4 V vs. Pt-QRE. To confirmthe electrodeposition process, potentiostatic electrodeposition of gold in the non-aqueous electrolyte was conducted at −0.4 V for 1 h at room temperature. To synthesize AuNPs, pulsed electrodeposition was conducted with controlled duty factor, pulse duration, and overpotential. The composition, particle-size distribution, and morphology of the AuNPs were confirmed by field-emission scanning electron microscopy (FE-SEM), energy-dispersive spectroscopy (EDS), and transmission electron microscopy (TEM). The electrodeposited AuNPs were uniformly distributed on the platinum electrode surface without any impurities arising from the non-aqueous electrolyte. The size distribution of AuNPs could be also controlled by the electrodeposition conditions.
Źródło:
Archives of Metallurgy and Materials; 2017, 62, 2B; 1389-1392
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Two-point Method for Arterial Local Pulse Wave Velocity Measurement by Means of Ultrasonic RF Signal Processing
Autorzy:
Trawiński, Z.
Powiązania:
https://bibliotekanauki.pl/articles/178000.pdf
Data publikacji:
2010
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
ultrasound
local pulse wave velocity
model of artery
Opis:
The aim of this paper is to describe a non-invasive method of examination of the local pulse wave velocity. The measurements were carried out in the model of the artery immersed in a water tank. Two synchronized ultrasonic apparatus VED with the ultrasonic radio frequency echoes acquisition system were used for evaluation of the arterial elasticity. The zero-crossing method was used for determination of the diameter changes of the artery model. The transit time between the waveforms of instant artery diameter was measured at two points of the artery model, separated by the distance of 5 cm. The transit time was determined using the criteria of similarity of the first derivatives of the raising slopes of the curves describing instant vessel’s diameter changes. The pulse wave velocity obtained by the proposed twopoint method was compared with the results obtained by the one-point method based on the modified Bramwell–Hill relation.
Źródło:
Archives of Acoustics; 2010, 35, 1; 3-11
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The effect of measurement position on brachial–ankle pulse wave velocity
Autorzy:
Shimawaki, S.
Toda, M.
Nakabayashi, M.
Sakai, N.
Powiązania:
https://bibliotekanauki.pl/articles/306488.pdf
Data publikacji:
2015
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
postawa ciała
prędkość
sztywność
staw kolanowy
posture
pulse wave velocity
vascular stiffness
knee flexion angle
Opis:
Arterial stiffness measurements are primarily used for the early detection of arteriosclerosis. Methods and devices that can easily measure arterial stiffness at home are in demand. We propose a simple method for measuring brachial–ankle pulse wave velocity (baPWV) at home using a reclining chair and investigate the effects of positioning on baPWV measurement. We measured baPWV in 50 healthy men (21–70 years) in seven different measurement positions, including the supine position, sitting, sitting with the knees flexed at 45°, sitting with the knees flexed at 0°, reclining at 37°, reclining at 50°, and standing. BaPWV was significantly lower in the supine position (P < 0.01) than in the other positions. It was significantly higher in the sitting position (P < 0.01) than in the reclining position (37°). No changes in baPWV were seen changing the knee flexion angle alone while sitting. Strong correlations were also observed between baPWV in the supine position and that in other positions. We showed that baPWV in the supine position can be calculated by making corrections to baPWV measured in the sitting position at a reclining angle. Utilizing this corrected value would allow easy measurement at home using a reclining chair.
Źródło:
Acta of Bioengineering and Biomechanics; 2015, 17, 1; 111-116
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A method of precise pulse onset determination using the Akaike Information Criterion for Ultrasound Transmission Tomography
Autorzy:
Pruchnicki, Piotr
Opieliński, Krzysztof J.
Powiązania:
https://bibliotekanauki.pl/articles/2146650.pdf
Data publikacji:
2021
Wydawca:
Politechnika Poznańska. Instytut Mechaniki Stosowanej
Tematy:
Akaike Information Criterion
AIC
pulse wave
transmission method
ultrasound tomography
kryterium informacyjne Akaike
fala tętna
metoda transmisyjna
tomografia ultradźwiękowa
Opis:
Information criteria used in statistics for model selection can be used to accurately determine pulse transition times in transmission methods. The most popular information criteria are the Akaike Information Criterion (AIC) and the Bayesian Schwartz Criterion (BIC). These criteria are considered the most reliable tests of model type and structure and are computationally simple. In this paper, an algorithm developed according to the AIC criterion is used to determine the transition time from transmission tomography measurements acquired with a multi-element ultrasonic ring array, which is the scanning element of the novel prototype of ultrasound tomography device for detecting and estimating the malignancy of female breast cancer in vivo. As a result, a new algorithm was developed to precise search for the onset of the recorded receiving pulse. The algorithm was tested in an aqueous environment using elementary pairs of transmitting and receiving ultrasonic transducers of a tomographic ring array.
Źródło:
Vibrations in Physical Systems; 2021, 32, 1; art. no. 2021115
0860-6897
Pojawia się w:
Vibrations in Physical Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of Artifical Discontinuities in Rocks on the Propagation of Ultrasonic P-Waves
Autorzy:
Kamaci, Z.
Akgüneş, B.
Powiązania:
https://bibliotekanauki.pl/articles/1029977.pdf
Data publikacji:
2018-05
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
ultrasonic pulse velocity
joint number
the wave attenuation
Opis:
In this work, experiments were conducted on rectangular prismatic samples with dimensions of 60×60×360 mm^{3}, which were cut from the rock blocks with no joint or anisotropy. Rock samples were obtained from different quarries in Turkey, known by the rock type as Afyon Çay marble, Burdur red limestone, Afyon gray, Lymra limestone, Muğla dolomite, Denizli travertine, and Isparta andesite. Experimental results indicated an increase in seismic wave attenuation as the number of artificial joints increased. However, seismic wave attenuation rate was found to be higher on the samples with parallel joint pattern than the samples which consisted of various directional joint pattern. This feature has explained the importance of seismic velocity anisotropy in rocks. The relationship between the number of joints in seven different rock samples and ultrasonic P-wave velocity was examined statistically and the results were evaluated together with similar studies in the literature.
Źródło:
Acta Physica Polonica A; 2018, 133, 5; 1144-1149
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Identification of Trace 2-Chloropropene with a New Chirped Pulse Microwave Spectrometer
Autorzy:
Kisiel, Z.
Kosarzewski, J.
Powiązania:
https://bibliotekanauki.pl/articles/1033441.pdf
Data publikacji:
2017-02
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
chirped pulse
Fourier transform microwave
supersonic expansion
millimetre wave
rotational spectroscopy
Opis:
The design of a new chirped pulse, Fourier-transform microwave spectrometer for recording broadband rotational spectra of supersonic expansion samples is described. The spectrometer can record spectral windows of width of up to 2.2 GHz over the 2-18 GHz frequency region. It is complemented by a new FFT program with several novel features. Tests of the spectrometer revealed the presence of an initially unknown volatile trace molecule in a sample of 2,2-dichloropropane (DCP). The broadband nature of the new spectrometer allowed rapid assignment of the new species as 2-chloropropene, CH₃CCl=CH₂ (2CP). Additional mm wave measurements combined with analysis of previous DCP spectra up to 311 GHz allow us to report the hitherto most precise spectroscopic constants for 2CP.
Źródło:
Acta Physica Polonica A; 2017, 131, 2; 311-317
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Examination of the Explosion Strike Factors of a Thermobaric Warhead
Badanie czynników rażenia wybuchu głowicy termobarycznej
Autorzy:
Długołęcki, A.
Faryński, A.
Klemba, T.
Słonkiewicz, Ł.
Ziółkowski, Z.
Powiązania:
https://bibliotekanauki.pl/articles/403963.pdf
Data publikacji:
2017
Wydawca:
Wojskowa Akademia Techniczna im. Jarosława Dąbrowskiego
Tematy:
mechanics
thermobaric explosion
shock wave
shock wave velocity
pressure pulse
mechanika
wybuch termobaryczny
fala uderzeniowa
prędkość fali uderzeniowej
impuls ciśnienia
Opis:
This paper presents the measurement method and results applicable to the pressure pulses and thermal effects generated by an explosion of an unguided thermobaric rocket missile warhead. The determination results include the shock wave pressure and velocity, the TNT equivalents of the thermobaric warheads, and the personnel strike radii of the shock wave. An estimation of the temperature increase rates at the shock wave front was also undertaken.
W artykule przedstawiono metodę i wyniki pomiarów impulsów ciśnienia i efektów termicznych generowanych przez wybuch głowicy termobarycznej rakiety niekierowanej. Wyznaczono ciśnienia i prędkości fal uderzeniowych, równoważniki trotylowe detonowanych głowic oraz promienie rażenia siły żywej przez falę uderzeniową, oszacowano przyrosty temperatury na froncie fali uderzeniowej.
Źródło:
Problemy Mechatroniki : uzbrojenie, lotnictwo, inżynieria bezpieczeństwa; 2017, 8, 1 (27); 39-54
2081-5891
Pojawia się w:
Problemy Mechatroniki : uzbrojenie, lotnictwo, inżynieria bezpieczeństwa
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-7 z 7

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies