Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "protons" wg kryterium: Temat


Wyświetlanie 1-5 z 5
Tytuł:
A portable fast neutron radiography system for non-destructive analysis of composite materials
Autorzy:
Kam, Erol
Reyhancan, Iskender A.
Biyik, Recep
Powiązania:
https://bibliotekanauki.pl/articles/148503.pdf
Data publikacji:
2019
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
fast neutron
radiography
scintillator
recoil protons
Opis:
Depending on the neutron energy used, neutron radiography can be generally categorized as fast and thermal neutron radiography. Fast neutron radiography (FNR) with neutron energy more than 1 MeV opens up a new range of possibilities for a non-destructive examination when the inspected object is thick or dense. Other traditional techniques, such as X-ray, gamma ray and thermal neutron radiography, do not meet penetration capabilities of FNR in this area. Because of these distinctive features, this technique is used in different industrial applications such as security (cargo investigation for contraband such as narcotics, explosives and illicit drugs), gas/liquid fl ow and mixing and radiography and tomography of encapsulated heavy shielded low Z compound materials. The FNR images are produced directly during exposure as neutrons create recoil protons, which activate a scintillator screen, allowing images to be collected with a computer-controlled charge-coupled device camera. Finally, the picture can be saved on a computer for image processing. The aim of this research was to set up a portable FN R system and to test it for use in non-destructive testing of different composite materials. Experiments were carried out by using a fast portative neutron generator Thermo Scientific MP 320.
Źródło:
Nukleonika; 2019, 64, 3; 97-101
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Verification of the use of GEANT4 and MCNPX Monte Carlo codes for calculations of the depth-dose distributions in water for the proton therapy of eye tumours
Autorzy:
Grządziel, M.
Konefał, A.
Zipper, W.
Pietrzak, R.
Bzymek, E.
Powiązania:
https://bibliotekanauki.pl/articles/147530.pdf
Data publikacji:
2014
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
depth-doses
GEANT4
MCNPX
therapeutic protons
Opis:
Verification of calculations of the depth-dose distributions in water, using GEANT4 (version of 4.9.3) and MCNPX (version of 2.7.0) Monte Carlo codes, was performed for the scatterer-phantom system used in the dosimetry measurements in the proton therapy of eye tumours. The simulated primary proton beam had the energy spectra distributed according to the Gauss distribution with the cut at energy greater than that related to the maximum of the spectrum. The energy spectra of the primary protons were chosen to get the possibly best agreement between the measured relative depth-dose distributions along the central-axis of the proton beam in a water phantom and that derived from the Monte Carlo calculations separately for the both tested codes. The local depth-dose differences between results from the calculations and the measurements were mostly less than 5% (the mean value of 2.1% and 3.6% for the MCNPX and GEANT4 calculations). In the case of the MCNPX calculations, the best fit to the experimental data was obtained for the spectrum with maximum at 60.8 MeV (more probable energy), FWHM of the spectrum of 0.4 MeV and the energy cut at 60.85 MeV whereas in the GEANT4 calculations more probable energy was 60.5 MeV, FWHM of 0.5 MeV, the energy cut at 60.7 MeV. Thus, one can say that the results obtained by means of the both considered Monte Carlo codes are similar but they are not the same. Therefore the agreement between the calculations and the measurements has to be verified before each application of the MCNPX and GEANT4 codes for the determination of the depth-dose curves for the therapeutic protons.
Źródło:
Nukleonika; 2014, 59, 2; 61-66
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Can laser - driven protons be used as diagnostics in ICF experiments ?
Autorzy:
Volpe, L.
Batani, D.
Powiązania:
https://bibliotekanauki.pl/articles/146375.pdf
Data publikacji:
2012
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
laser-driven protons
inertial confinement fusion (ICF)
proton radiography (PR)
radio-chromic films (RCF)
Opis:
Point projection proton backlighting was recently used to image a cylindrical imploding target at Rutherford Appleton Laboratory (UK). Due to the relatively low energy and to the very large mass densities reached during implosion, protons traveling through the target undergo a very large number of collisions which reduced the resolution. Here, we present a simple analytical model to study the proton radiography (PR) performance as a function of the main experimental parameters. This approach leads to define two different criteria for PR resolution describing different experimental conditions.
Źródło:
Nukleonika; 2012, 57, 2; 231-235
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Experimental Evidence That Hubble’s Parameter Could Be Reflected in Local Physical and Chemical Reactions: Support for Mach’s Principle of Imminence of the Universe
Autorzy:
Persinger, M.A.
Powiązania:
https://bibliotekanauki.pl/articles/412010.pdf
Data publikacji:
2013
Wydawca:
Przedsiębiorstwo Wydawnictw Naukowych Darwin / Scientific Publishing House DARWIN
Tematy:
Hubble constant
Planck's length expansions
protons and electrons
point durations
Mach’s principle
local estimates
Opis:
Mach’s principle of immanence of the universe requires the behavior of local matter to depend upon the remainder of the universe. Hubble’s constant could be employed to calculate the inference of this condition. More than a decade ago specific types of temporally patterned magnetic fields generated by serial 3 ms point durations were shown to produce conspicuous biochemical effects. When the product of this duration and the diameter of a proton was divided into Planck’s Length the estimated Hubble’ parameter was 66.7 ±1.3 km∙ s-1•MParsec-1 which is remarkably similar to the current value of 67.8 km∙ s-1. Photon emissions from chemoluminescent reactions and discrete shifts in pH within spring water during exposure to specific patterns of magnetic fields revealed optimal responses with remarkably similar z-transformations when point durations of the constructive voltages were 3 ms or 1 ms but not 2, 4, or 5 ms. Cumulative results indicate proton (3 ms) and electron (~1.5 ms) processes. These results support Mach’s contention and indicate that relatively accurate inferences of the Hubble parameter might be obtained with more precise instrumentation on the terrestrial surface.
Źródło:
International Letters of Chemistry, Physics and Astronomy; 2013, 11; 86-92
2299-3843
Pojawia się w:
International Letters of Chemistry, Physics and Astronomy
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The magnetic field produced by a protons beam with the three-axial Gauss distribution
Pole magnetyczne wytwarzane przez wiązkę protonów o trójwymiarowym rozkładzie Gaussa
Autorzy:
Bednarek, Stanisław
Płoszajski, Julian
Powiązania:
https://bibliotekanauki.pl/articles/699894.pdf
Data publikacji:
2018
Wydawca:
Łódzkie Towarzystwo Naukowe
Tematy:
magnetic field, electric field, space distribution, Lorentz transformation, protons bunch, accelerator
pole magnetyczne, pole elektryczne, rozkład przestrzenny, transformacja Lorentza, wiązka protonów, akcelerator
Opis:
https://doi.org/10.26485/0459-6854/2018/68.3/8 Artykuł zawiera opis własnej metody obliczania natężenia pola elektrycznego i indukcji pola magnetycznego, które są wytwarzane przez paczki wchodzące w skład relatywistycznej wiązki protonów. Rozkład przestrzenny gęstości ładunku elektrycznego w tej paczce opisywany jest trójosiowym rozkładem Gaussa. Metoda polega na obliczeniu składowych natężenia pola elektrycznego w układzie poruszającym się wraz z paczką, a następnie zastosowaniu transformacji Lorentza dla pola elektromagnetycznego. W wyniku tego otrzymuje się wartości składowych natężenia pola elektrycznego i indukcji pola magnetycznego w układzie spoczywającym, gdzie mogą być umieszczane próbki badane w tych polach. Wyprowadzone przy użyciu tej metody wzory zostały zebrane w tabelach i przedyskutowane. Wzory te zastosowano do obliczeń na przykładzie paczek protonów, przyspieszanych w akceleratorze LHC. Otrzymane wyniki przedstawiono na wykresach i także przedyskutowano. Użyteczne wartości indukcji pola magnetycznego i natężenia pola elektrycznego są bardzo zbliżone do wartości otrzymanych we wcześniej opublikowanym artykule, w którym zastosowano jednoosiowy rozkład Gaussa. Przedstawione w tym artykule wyniki również potwierdzają możliwości wykorzystania takich paczek cząstek, jako źródła silnych, impulsowych pól magnetycznych, użytecznych m.in. do badań w fizyce ciała stałego, fizyce fazy skondensowanej i elektronice.
https://doi.org/10.26485/0459-6854/2018/68.3/8 This paper contains a description of an original calculations method of electric field intensity and magnetic field induction which were produced by bunches assembling relativistic proton beams. The spatial distribution of electric charge density inside the bunch is described by the three-axial Gauss distribution. The method consists of component calculations of the electric field intensity at the frame of reference moving with the bunch and further, on the application of the Lorentz transformation to electromagnetic fields. As a result, we obtained values of components of electric field intensity and magnetic field induction at the rest frame of reference where could be located examined samples. Formula worked out with the method were discussed and gathered at the tables. Formula were applied to calculations of proton bunches accelerated in the LHC. The collected results were presented in the form of charts and discussed. Useful values of magnetic field induction and electric field intensity were very close to already published at the paper in which one-axial Gauss distribution was applied. The results contained in this paper confirmed possibility of using such particle bunches as sources of strong magnetic field pulses, useful among the others, in solid state physics, condensed phase physics and electronics as well.
Źródło:
Bulletin de la Société des Sciences et des Lettres de Łódź, Série: Recherches sur les déformations; 2018, 68, 3
1895-7838
2450-9329
Pojawia się w:
Bulletin de la Société des Sciences et des Lettres de Łódź, Série: Recherches sur les déformations
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-5 z 5

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies