Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "operation fault" wg kryterium: Temat


Wyświetlanie 1-4 z 4
Tytuł:
Research on topology of a novel three-phase four-leg fault-tolerant NPC inverter
Autorzy:
Zhang, Baoge
Ping, Shanyan
Long, Yyi
Jiao, Yyuemin
Wu, Bboxiang
Powiązania:
https://bibliotekanauki.pl/articles/2086722.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
fault tolerant operation
midpoint potential equilibrium
NPC inverter
topology reconstruction
Opis:
Diode neutral point clamped (NPC) three-level converters have been widely used in recent years. Aiming at the problems of the high device failure rate and unstable neutral point potential of NPC three-level converters, an NPC three-level circuit with fourth bridge arm redundancy is proposed based on the traditional NPC three-level converter. The redundant fourth bridge arm is used to realize the function of stabilizing voltage when there is no fault and replacing the fault half-bridge arm to maintain the continuous operation of the converter when there is a fault. By analyzing the working principle of space vector pulse width modulation (SVPWM) and the power loss of the switch, it is of particular significance to the design and control of NPC three-level converters in the future. Matlab/Simulink verifies the feasibility of the fault-tolerant circuit structure.
Źródło:
Archives of Electrical Engineering; 2022, 71, 2; 489--506
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Study of current space phasor trajectory of the three-phase asynchronous motor with one phase open circuit fault
Badanie trajektorii przestrzennego fazora prądu silnika asynchronicznego trójfazowego przy uszkodzeniu jednej fazy
Autorzy:
Záskalický, P.
Powiązania:
https://bibliotekanauki.pl/articles/1367339.pdf
Data publikacji:
2016
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
Fourier series
asynchronous motor
two-phase operation
fault tolerance
Opis:
The presented paper deals with the calculation of space phasor trajectory of the magnetization current of induction machine supplied by a converter under open-phase fault. To explore possibilities to reduce the impact of failure on the function of the machine is a winding node connected to zero point. Under open phase fault it is another possibility to improve behavior of the two-phase operation. There is still to apply a circular rotating magnetic field to the machine by imposing a 60o phase shift between the stator currents of the two supplied stator windings.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2016, 3, 111; 147-151
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The analysis of transformers condition based on Bayes-discriminant method with fault-tree fuzzy evaluation
Autorzy:
Li, Dianyang
Wang, Shanyuan
Zhang, Yujie
Feng, Jian
Wang, Hongzhe
Qin, Ling
Powiązania:
https://bibliotekanauki.pl/articles/328004.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Polskie Towarzystwo Diagnostyki Technicznej PAN
Tematy:
oil-immersed power transformers
fault tree analysis
fuzzy-evaluation system
Bayes-discriminant
health-operation
transformator mocy
system monitorowania
analiza drzewa błędów
Opis:
China's electric power construction is renewing Increasingly, and the network is complex and changeable where the automation is getting higher. In this paper, Fuzzy evaluation system is established according to fault tree, and the estimation of transformer’s state is judged by analytic hierarchy process. Bayes-discriminant and discriminant formula are used to discriminate transformer’s attributes, which are based on historical data. The machine identification of transformer faults combines the fuzzy evaluation and Bayes-discriminant. It’s accuracy can be improved by correcting parameters. This method can effectively avoid subjective interference caused by artificial weights. The example shows that this method could be applied to judge health status of electric power equipment and this method can play an early-warning role in the operation of monitoring system.
Źródło:
Diagnostyka; 2020, 21, 2; 3-12
1641-6414
2449-5220
Pojawia się w:
Diagnostyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Electromagnetic torque ripple diminution of a fivephase asynchronous motor with one phase open circuit fault
Redukcja tętnień momentu elektromagnetycznego pięciofazowego silnika asynchronicznego przy jednofazowej utracie mocy
Autorzy:
Záskalický, Pavel
Kaňuch, Ján
Powiązania:
https://bibliotekanauki.pl/articles/2142547.pdf
Data publikacji:
2022
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
five-phase induction machine
torque ripple
pentagon connection
one phase fault
four-phase operation
maszyna indukcyjna pięciofazowa
tętnienie momentu obrotowego
połączenie pięciokątne
uszkodzenie jednofazowe
praca czterofazowa
Opis:
The presented paper deals with the five-phase induction motor (IM) having pentagon connected stator winding, which is working under one phase supply failure. Computation of the motor electromagnetic quantities was made using the space vector theory in the complex plane. Analysis is done assuming, the motor is supplied by a pulse width modulation (PWM) controlled inverter with sufficiently high modulation frequency. Only the first stator voltage harmonics is taken into consideration. On the base of measured IM parameters, trajectories of stator and rotor current space vectors were investigated. On their basis, the motor electromagnetic torque ripple waveform for failure supply mode is derived. Finally a possibility to reduce torque ripple in failure state is shown.
W artykule opisano pięciofazowy silnik indukcyjny (SI) o pięciokątnym uzwojeniu stojana, pracujący przy jednofazowym zaniku zasilania. Obliczenia wielkości elektromagnetycznych silnika przeprowadzono z wykorzystaniem teorii wektorów przestrzennych na płaszczyźnie zespolonej. Analizę przeprowadzono przy założeniu, że silnik jest zasilany z falownika sterowanego modulacją szerokości impulsów (PWM) o odpowiednio wysokiej częstotliwości modulacji. Uwzględniono tylko pierwszą harmoniczną napięcia stojana. Na podstawie zmierzonych parametrów SI zbadano trajektorie wektorów przestrzeni prądów stojana i wirnika. Na ich podstawie wyznaczono przebieg tętnień momentu elektromagnetycznego silnika dla trybu zasilania awaryjnego. Na zakończenie przedstawiono możliwość redukcji tętnień momentu w stanie awaryjnym.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2022, 3, 1 (127); 51--57
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-4 z 4

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies