Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "oil transformer" wg kryterium: Temat


Wyświetlanie 1-6 z 6
Tytuł:
The impact of electromagnetic radiation on the degradation of magnetic ferrofluids
Autorzy:
Pavlík, M.
Kruželák, L.
Mikita, M.
Špes, M.
Bucko, S.
Lisoň, L.
Kosterec, M.
Beňa, L.
Liptai, P.
Powiązania:
https://bibliotekanauki.pl/articles/140420.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
ferrofluids
electromagnetic radiation
oxidation stability
transformer oil
Opis:
This article deals with magnetic nano-fluids, which are the part of transformer oil ITO 100 and their behavior is influenced by a permanent magnetic field. We performed an IRC analysis in the time domain on the three different samples. Measurements were made before and after radiation of an electromagnetic field. The main objective was to examine changes in the properties of the samples due to the influence of the electromagnetic field. The measurements depend on the orientation of the external magnetic field. This behavior occurs especially during the structuring of the nanoparticles in the sample exposed to the magnetic field. These processes change the polarization of the liquid because the nanoparticles concentration is contained in the fluid.
Źródło:
Archives of Electrical Engineering; 2017, 66, 2; 361-369
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The monitoring of oil distribution transformers in laboratory conditions
Monitoring rozdzielczych transformatorów olejowych w warunkach laboratoryjnych
Autorzy:
Gutten, M.
Korenčiak, D.
Jurčik, J.
Kołtunowicz, T. N.
Powiązania:
https://bibliotekanauki.pl/articles/156829.pdf
Data publikacji:
2013
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
olej transformatorowy
czujnik gazu i wody
chromatografia
monitoring
oil transformer
gas and moisture sensor
chromatography
Opis:
The paper deals with physical fundamentals of monitoring the high-voltage oil transformer 22/0,4 kV by gas- and moisture-in-oil sensors, optical temperature sensors and an electric quantities analyser.
W artykule omówiono fizyczne podstawy monitorowania olejowych wysokonapięciowych transformatorów 22/0,4 kV przy pomocy analizatora zawartości wilgoci gazów w oleju, optycznych czujników temperatury oraz analizatora wielkości elektrycznych. Stwierdzono, że ze wzrostem stopnia zawilgocenia oleju w czasie pracy transformatora następują zmiany takich podstawowych jego właściwości jak napięcie przebicia, współczynnik strat dielektrycznych oraz rezystywność. Naprężenia elektryczne i termiczne skutkują powstawaniem w oleju szeregu gazów, które można wykorzystać do wczesnej diagnozy powstających uszkodzeń urządzenia elektrycznego. Uszkodzenia takie mogą powstawać w różnym tempie, dlatego optymalna do ich detekcji jest diagnostyka on-line. W tym celu kanadyjska firma GE Energy Services opracowała przyrząd Hydran umożliwiający analizę parametrów oleju. W artykule przedstawiono przykład praktycznego wykorzystania tego miernika, który wraz z pomiarami termowizyjnymi wykorzystano do monitorowania transformatora w laboratorium. Zaobserwowano, że w zależności od obciążenia następują zmiany zawartości wody w oleju transformatorowym. Podczas takiego procesu właściwości oleju pogarszały się.
Źródło:
Pomiary Automatyka Kontrola; 2013, R. 59, nr 2, 2; 116-119
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Diagnostics of the state of oil-paper insulation in group 2 transformers
Diagnostyka stanu izolacji papierowo-olejowej transformatorów drugiej grupy
Autorzy:
Gos, A.
Gos, M.
Mroczkowski, P.
Powiązania:
https://bibliotekanauki.pl/articles/257212.pdf
Data publikacji:
2014
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Technologii Eksploatacji - Państwowy Instytut Badawczy
Tematy:
transformer oil
oil-paper insulation
transformer diagnosis
olej elektroizolacyjny
izolacja papierowo-olejowa
diagnostyka
transformator
Opis:
The article describes causes of the need to monitor the technical condition of transformers by analysing the physicochemical properties of the oil-paper insulation. The article also describes the importance of individual indicators determining the quality of transformer oil and discusses the results of the operating oil in a 49-year-old transformer before and after exchange.
W artykule opisano przyczyny konieczności monitorowania stanu technicznego transformatorów poprzez analizę właściwości fizykochemicznych izolacji papierowo-olejowej. Opisano znaczenie poszczególnych wskaźników decydujących o jakości oleju transformatorowego oraz omówiono wyniki oleju pracującego w 49-letnim transformatorze przed i po jego wirowaniu.
Źródło:
Problemy Eksploatacji; 2014, 3; 73-81
1232-9312
Pojawia się w:
Problemy Eksploatacji
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Effect of Solvent, Hydrogen Peroxide and Dioxide Titanium on Degradation of PCBs, Using Microwave Radiation in Order to Reduce Occupational Exposure
Autorzy:
Tajik, R.
Mohabadi, H. A.
Khavanin, A.
Jafari, A. J.
Eshrati, B.
Powiązania:
https://bibliotekanauki.pl/articles/205106.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
degradation
ethanol
microwave
transformer oil
degradacja
etanol
mikrofale
olej transformatorowy
Opis:
Polychlorinated biphenyls (PCBs) are one group of persistent organic pollutants (POPs) that are of international concern because of global distribution, persistence, and toxicity. Removal of these compounds from the environment remains a very difficult challenge because the compounds are highly hydrophobic and have very low solubility in water. A 900 W domestic microwave oven, pyrex vessel reactor, pyrex tube connector and condensing system were used in this experiment. Radiation was discontinuous and ray powers were 540, 720 and 900 W. The PCBS were analyzed by GC-ECD. The application of microwave radiation and H2O2/TiO2 agents for the degradation of polychlorinated biphenyl contaminated oil was explored in this study. PCB – contaminated oil was treated in a pyrex reactor by microwave irradiation at 2450 MHz with the addition of H2O2/TiO2. A novel grain TiO2 (GT01) was used. The determination of PCB residues in oil by gas chromatography (GC) revealed that rates of PCB decomposition were highly dependent on microwave power, exposure time, ratio to solvent with transformer oil in 3:1, the optimal amount of GT01 (0.2 g) and 0.116 mol of H2O2 were used in the study. It was suggested that microwave irradiation with the assistance of H2O2/TiO2 might be a potential technology for the degradation of PCB – contaminated oil. The experiments show that MW irradiation, H2O2 oxidant and TiO2 catalyst lead to a degradation efficiency of PCBs only in the presence of ethanol. The results showed that the addition of ethanol significantly enhanced degradation efficiency of PCBs.
Źródło:
Archives of Environmental Protection; 2014, 40, 2; 91-102
2083-4772
2083-4810
Pojawia się w:
Archives of Environmental Protection
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Measuring device moisture content of transformer oil
Izmeritelnoe ustrojjstrvo vlagosoderzhanija transformatornogo masla
Autorzy:
Polovinka, D.
Nevzlyn, B.
Syrtsov, A.
Powiązania:
https://bibliotekanauki.pl/articles/792806.pdf
Data publikacji:
2013
Wydawca:
Komisja Motoryzacji i Energetyki Rolnictwa
Tematy:
moisture content
transformer oil
measuring device
Lambert function
measuring transducer
quality factor
Źródło:
Teka Komisji Motoryzacji i Energetyki Rolnictwa; 2013, 13, 4
1641-7739
Pojawia się w:
Teka Komisji Motoryzacji i Energetyki Rolnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The application of a molecular sieve for drying the insulation system of a power transformer in terms of improving its perational reliability
Autorzy:
Cybulski, Mateusz
Przybyłek, Piotr
Powiązania:
https://bibliotekanauki.pl/articles/2172034.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Polskie Naukowo-Techniczne Towarzystwo Eksploatacyjne PAN
Tematy:
power transformer
insulation system
drying
molecular sieve
mineral oil
natural ester
synthetic ester
Opis:
The first research objective was the assessment of the selectivity of water and hydrogen adsorption by the 3A molecular sieve (MS) in the terms of the safety of using the DGA (Dissolved Gas Analysis) method as a diagnostic technique. The second objective was to demonstrate the efficiency of drying the insulation system consisting of cellulose insulation impregnated with various insulating liquids in terms of improving safety and extending the service life of power transformers. In order to achieve the assumed objectives, measurement systems were prepared and material tests were carried out, based mainly on chromatographic analyzes and measurements of water content using the Karl Fischer titration method. On the basis of the obtained test results and the conducted physical analyzes, the selectivity of MS sorption was shown and it was explained that the facilitator of the adsorption of water molecules is their polar nature related to their large dipole moment. The high efficiency of drying cellulose insulation impregnated with various insulating liquids using MS was also demonstrated.
Źródło:
Eksploatacja i Niezawodność; 2022, 24, 3; 502--509
1507-2711
Pojawia się w:
Eksploatacja i Niezawodność
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-6 z 6

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies