Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "ogranicznik" wg kryterium: Temat


Wyświetlanie 1-10 z 10
Tytuł:
Proposals for Protection of Return Cables on SwePol Link
Propozycje ochrony kabli powrotnych w łączu Szwecja – Polska
Autorzy:
Szczepański, T.
Powiązania:
https://bibliotekanauki.pl/articles/397506.pdf
Data publikacji:
2013
Wydawca:
ENERGA
Tematy:
return cable
surge arrester
electrode
kabel powrotny
ogranicznik przepięć
elektroda
Opis:
The return cable on the SwePol Link has been introduced as an alternative forced by environmentalists due to lack of social acceptance of other solutions. This is why in the proposed solution water and earth have been replaced by two return cables, although from a technical point of view such a solution is less effective. The last, eleventh fault of the return cable took place on 15 October 2012. In eight earlier cases the faults were caused by electrical failures in the cable in the sea and were located between ten and twenty kilometers from the Polish shore and triggered by disturbances in the northern part of the Polish power grid. In this situation it has been suggested to analyze and introduce one or two solutions shown below which may significantly limit the effects and lower the costs caused by return cable faults: a) assembly of additional surge arresters b) return to electrodes – lack of return cables c) ”partial” electrodes working with one return cable d) operation of the link only with earthings on converter stations. To sum up it needs to be stated that: • a relatively cheap way of protecting return cables against electrical failures is installing surge arresters in the cabinet located next to the cable container on the Polish shore • from the suggested preventive measures it seems reasonable to introduce the above mentioned solutions a) and d) simultaneously, as both of them are simple solutions which require neither considerable financial expenditure nor authorizations and may quickly show the expected results.
Streszczenie Kabel powrotny w łączu Szwecja – Polska pojawił się jako alternatywa wymuszona przez ekologów. Dlatego w wykonanym rozwiązaniu zastąpiono wodę i ziemię dwoma kablami powrotnymi, chociaż z punktu widzenia technicznego wprowadzone rozwiązanie daje niższą sprawność. Ostatnio do jedenastego uszkodzenia kabla powrotnego doszło 15 października 2012 roku. W ośmiu wcześniejszych przypadkach przyczynami awarii były uszkodzenia elektryczne kabla w morzu, w odległości kilkunastu kilometrów od polskiego brzegu, spowodowane zakłóceniami w północnej części polskiego systemu elektroenergetycznego.
Źródło:
Acta Energetica; 2013, 1; 147-156
2300-3022
Pojawia się w:
Acta Energetica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Voltage dips reduction with a hybrid contectless short-circuit limiter
Ograniczenie zapadów napięcia za pomocą bezstykowego ogranicznika prądu
Autorzy:
Leśniewski, P.
Gohra, K.
Powiązania:
https://bibliotekanauki.pl/articles/152073.pdf
Data publikacji:
2003
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
łącznik hybrydowy
zapady napięcia
bezstykowy ogranicznik prądu
hybrid circuit breaker
voltage dip
contactless current limiter
Opis:
The paper presents operation of a hybrid contactless short-circuit current limiter on the basis of computer simulation. Special attention was paid to the possibility of improving of the quality of the delivered electrical energy, throught limiting of the voltage dips duration in the power grid owing to the application of a hybrid circuit breaker. The calculations were performed usingthe PSPICE and MATLAB software.
W artykule przedstawiono działanie bezstykowego ogranicznika prądów zwarciowych w oparciu o symulacje komputerową. SzczególnA uwagę zwrócono na możliwość poprawy jakości dostarczanej energii elektroenergetycznej, dzięki zastosowaniu wyłącznika hybrydowego. Modelowanie matematyczne wykonano w programie MATLAB i PSPICE.
Źródło:
Pomiary Automatyka Kontrola; 2003, R. 49, nr 12, 12; 74-76
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Tests of HTS 2G superconducting tapes using the LabVIEW environment
Autorzy:
Kwoka, R.
Kozak, J.
Majka, M.
Powiązania:
https://bibliotekanauki.pl/articles/118249.pdf
Data publikacji:
2018
Wydawca:
Polskie Towarzystwo Promocji Wiedzy
Tematy:
superconducting winding
HTS tape
LabVIEW
superconducting fault current limiter
uzwojenie nadprzewodzące
Taśma HTS
nadprzewodnikowy ogranicznik prądu zwarciowego
Opis:
HTS 2G superconducting tapes without stabilizer are used for the construction of superconducting fault current limiters. The characteristics R =f(T) of the su-perconducting tape is essential for design of superconducting current limiters and analysis of their numerical models. The article presents the experimentally determined characteristics R=f(T) of the second ge-neration superconducting tapes SF4050 and SF12050 using the LabVIEW integrated environment. The article describes the method of sample preparation and methodology of testing of HTS 2G superconducting tapes. The LabVIEW integrated environment was used for the testing, thanks to which it was possible to download, process and save measurement data.
Źródło:
Applied Computer Science; 2018, 14, 1; 64-72
1895-3735
Pojawia się w:
Applied Computer Science
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The meaning of different limiters relations for defining public transport routes capacity
Znaczenie powiązania różnych ograniczników dla określania przepustowości tras komunikacyjnych
Autorzy:
Molecki, A.
Powiązania:
https://bibliotekanauki.pl/articles/375156.pdf
Data publikacji:
2007
Wydawca:
Politechnika Śląska. Wydawnictwo Politechniki Śląskiej
Tematy:
system komunikacyjny
przepustowość drogi
ogranicznik przepustowości
metoda Monte Carlo
transportation system
road capacity
limiter of capacity
Monte Carlo method
Opis:
The mutual affecting of different limiters of capacity is a very important feature, which makes difficult the right appreciation of the transport systems. In most cases, there is no way to use procedures which define relations by correlation coefficients etc. Completely divergent character of limiters induce that only way of effective appreciation is modeling by Monte Carlo simulations.
Wzajemne oddziaływanie różnych ograniczników przepustowości jest bardzo ważną cechą utrudniającą właściwą ocenę układów komunikacyjnych. W większości przypadków procedury określające powiązania za pomocą współczynników korelacji nie mają zastosowania itp. Całkowicie rozbieżny charakter występujących ograniczników powoduje, że jedyną drogą prowadzącą do skutecznej oceny staje się modelowanie symulacyjne Monte Carlo.
Źródło:
Transport Problems; 2007, 2, 1; 95-100
1896-0596
2300-861X
Pojawia się w:
Transport Problems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of heating of inductive superconducting fault current limiter windings on current limiting performance
Wpływ nagrzewania się uzwojeń nadprzewodnikowego ogranicznika prądu na wydajność ograniczania prądu
Autorzy:
Kafarski, M.
Adamczyk, Ł.
Kozak, S.
Kozak, J.
Majka, M.
Powiązania:
https://bibliotekanauki.pl/articles/408798.pdf
Data publikacji:
2012
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Tematy:
nadprzewodnikowy ogranicznik prądu
taśma HTS
nagrzewanie taśmy HTS
inductive superconducting fault current limiter
HTS tape
heating of HTS tape
Opis:
One of the types of superconducting fault current limiters are inductive. Windings in these limiters are made of second generation superconducting tapes (HTS 2G). Large resistance in resistive state and large currents flowing by the limiter windings during the fault cause the dissipate significant amounts of power and strong heating of the windings, which causes increase in impedance of the limiter. We discuss the influence of the windings heating on the value of limiting short circuit current.
Jednym z typów nadprzewodnikowych ograniczników prądu są ograniczniki typu indukcyjnego. Ich uzwojenia wykonane są z taśmy nadprzewodnikowej drugiej generacji (2G). Duża rezystancja w stanie rezystywnym i duże wartości prądów zwarciowych powodują wydzielanie dużych ilości energii i silne nagrzewanie uzwojeń, które powoduje wzrost impedancji ogranicznika. W artykule omówiono wpływ agrzewania sie uzwojeń na wydajność ograniczania prądów zwarciowych.
Źródło:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska; 2012, 1; 24-27
2083-0157
2391-6761
Pojawia się w:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Investigations of the transport possibilities of a new vibratory conveyor equipped with a single electrovibrator
Autorzy:
Żmuda, Weronika
Czubak, Piotr
Powiązania:
https://bibliotekanauki.pl/articles/2203864.pdf
Data publikacji:
2022
Wydawca:
Politechnika Śląska. Wydawnictwo Politechniki Śląskiej
Tematy:
vibrations
vibratory conveyor
dynamic eliminator
transport stop
feeder
reverse transport
wibracje
przenośnik wibracyjny
eliminator dynamiczny
ogranicznik transportu
podajnik
transport zwrotny
Opis:
In the present study, a new vibratory conveyor (patent pending) equipped with a single electro-vibrator intended for an accurate material dosage is investigated. The possibilities of material transportation in the circum-resonant zone were investigated analytically and by simulations [1]. Furthermore, the dependencies of the transport velocity of the tested conveyor as functions of the excitation frequency were determined. Favorable excitation frequencies at transports in the main and reversal directions were found, and the high usefulness of the machine in the production lines requiring accurate material dosage was indicated. A control strategy allowing for a sudden stop of the transported material was also proposed.
Źródło:
Transport Problems; 2022, 17, 4; 127--136
1896-0596
2300-861X
Pojawia się w:
Transport Problems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Study of transport possibilities in the resonance zone of the new vibratory conveyor equipped with the single electro-vibrator
Autorzy:
Żmuda, Weronika
Czubak, Piotr
Powiązania:
https://bibliotekanauki.pl/articles/24201981.pdf
Data publikacji:
2023
Wydawca:
Politechnika Poznańska. Instytut Mechaniki Stosowanej
Tematy:
vibrations
vibratory conveyor
dynamic eliminator
transport stop
feeder
material dosing
drgania
przenośnik wibracyjny
eliminator dynamiczny
ogranicznik transportu
podajnik
dozowanie materiału
Opis:
The new vibratory conveyor, which is during patent pending [1], equipped with a single electro-vibrator intended for an accurate material dosing, was investigated in the hereby study. Possibilities of material transportations and dosing both in and out the circum-resonant zone were investigated. Dependencies of the transport velocity of the tested conveyor as functions of the excitation frequency for a certain range of load were determined. The high usefulness of the machine in the production lines requiring accurate material dosing was indicated. It was pointed out that the conveyor can transport the feed at a constant velocity, regardless of the feed mass, which is unique for the conveyors of inertial drive.
Źródło:
Vibrations in Physical Systems; 2023, 34, 1; art. no. 2023116
0860-6897
Pojawia się w:
Vibrations in Physical Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Prediction of lightning density value tower based on Adaptive Neuro-fuzzy Inference System
Autorzy:
Said, Sri Mawar
Nappu, Muhammad Bachtiar
Asri, Andarini
Utomo, Bayu Tri
Powiązania:
https://bibliotekanauki.pl/articles/1841146.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
adaptive neuro-fuzzy inference system
lightning density prediction tower
Transmission Line Arrester
adaptacyjny system wnioskowania neurorozmytego
wieża prognozowania gęstości piorunów
ogranicznik linii transmisyjnej
Opis:
Lightning is one of the causes of transmission disorders and natural phenomena that cannot be avoided. The South Sulawesi region is located close to the equator and has a high lightning density. This condition results in lightning susceptibility of distur- bances to electrical system lines, especially in high-voltage airlines and substations. An Adaptive Neuro-Fuzzy Inference System (ANFIS) will show the Root Mean Square Error (RMSE) based on the membership function type. This journal is to predict the value of the transmission tower lightning density using the ANFIS method. The value of the lightning strike density index can later be determined based on ANFIS predictions. Analysis of the value calculation system of structural lightning strikes in the South Sulawesi region of the Sungguminasa-Tallasa route can be categorized as three characteristics lightning density (Nd). The calculation system results for the value of structural lightning struck in the South Sulawesi region and validated between manual calculations and ANFIS with an average percentage of 0.0554%.
Źródło:
Archives of Electrical Engineering; 2021, 70, 3; 499-511
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Switching and lightning overvoltages and the required withstand voltage betweeen the open contacts of 245 KV circuit breakers
Przepięcia łączeniowe i piorunowe a wymagany poziom wytrzymałości otwartych styków wyłączników 245 KV
Autorzy:
Bandel, J.
Hejduk, A.
Dzierżyński, A.
Korycki, P.
Sibilski, H.
Powiązania:
https://bibliotekanauki.pl/articles/159303.pdf
Data publikacji:
2016
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Elektrotechniki
Tematy:
high voltage circuit breakers
switching inductive and capacitive currents
switching and atmospheric overvoltage
lightning arresters
wyłączniki najwyższych napięć
łączenie prądów indukcyjnych i pojemnościowych
przepięcia łączeniowe i atmosferyczne
ogranicznik napięcia
Opis:
Przedstawiono sposób oceny wartości przepięć generowanych w sieci pomiędzy otwartymi stykami wyłącznika podczas operacji łączeniowych i wyładowań piorunowych. Wartości przepięć porównano z wartościami napięć probierczych wyłączników. Zaproponowano sposób doboru ograniczników napięcia. Wyłączanie prądów zwarciowych może powodować osłabienie izolacji komory wyłącznika zmniejszając jego wytrzymałość elektryczną i trwałość łączeniową. W energetyce zgłaszano przypadki zapłonów łuku na otwartych stykach wyłączników, tego rodzaju awarie mogą być bardzo groźne w skutkach. Problem ten dotyczy przede wszystkim wyłączników jednoprzerwowych, w których naprężenia elektryczne izolacji przerwy pomiędzy stykowej wyłącznika są bardzo duże. Z tego powodu pojawiają się postulaty zwiększenia liczby łączeń podczas badań typu wyłącznika, jakie należy wykonywać bez wymiany jakichkolwiek części komory wyłącznika, czy też napędu.
This paper deals with the surges generated in the network during switching operations and lightning surges. The level of both kinds of surge was compared with the required dielectric strength between the open contacts of 245 kV circuit breakers. Overvoltages greater than the electrical withstand voltage of the circuit breaker can cause arc ignition between the circuit breaker’s open contacts and power engineering service s have reported such cases. The results of such failures can be very serious. This is a problem especially for single-break circuit breakers, in which the stresses on the electrical insulation between the open contacts of the breaker are very high. A method for selecting lightning arresters to lower the overvoltages is proposed. The switching of short-circuit currents by a circuit breaker may cause a weakening of the circuit breaker chamber’s insulation and reduce its electrical withstand and durability.
Źródło:
Prace Instytutu Elektrotechniki; 2016, 274; 43-60
0032-6216
Pojawia się w:
Prace Instytutu Elektrotechniki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Perspective on basic architectures and properties of unconventional and Field Induced Josephson junction devices
Autorzy:
Pomorski, K.
Prokopow, P
Powiązania:
https://bibliotekanauki.pl/articles/397965.pdf
Data publikacji:
2013
Wydawca:
Politechnika Łódzka. Wydział Mikroelektroniki i Informatyki
Tematy:
uJJ Josephson junction arrays
FIJJ Josephson junction arrays
uJJ Josephson junction matrices
FIJJ Josephson junction matrices
uJJ fault current limiter
FIJJ fault current limiter
various geometries of Ujj
various geometries of FIJJ
uJJ SQUID
FIJJ SQUID
relaxation algorithm
złącze Josephsona uJJ
złącze Jospphsona FIJJ
matryce złącz Josephsona
ogranicznik prądu zwarciowego
algorytm relaksacyjny
Opis:
We present the concept of unconventional and Field Induced Josephson junction (uJJ and FIJJ) and devices built from them. They can be made by placement of ferromagnetic strip on top of a superconducting strip. In such case modulation of superconducting order parameter and magnetization is obtained. Furthermore we can build tunable Josephson junction arrays, which can be tuned by applying external magnetic field to some circuit element(s). We present the superconducting order parameter distributions obtained from extended Ginzburg-Landau functional, which includes the coexistence of superconducting order parameter and magnetization. We present the case of SQUID built in uJJ and FIJJ architecture and current limiter.
Źródło:
International Journal of Microelectronics and Computer Science; 2013, 4, 3; 110-115
2080-8755
2353-9607
Pojawia się w:
International Journal of Microelectronics and Computer Science
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-10 z 10

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies