Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "multichannel system" wg kryterium: Temat


Wyświetlanie 1-6 z 6
Tytuł:
Properties of Amplitude Distributions of Acoustic Emission Signals Generated in Pressure Vessel During Testing
Autorzy:
Witos, Franciszek
Powiązania:
https://bibliotekanauki.pl/articles/178028.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Czasopisma i Monografie PAN
Tematy:
acoustic emission
multichannel measuring system
amplitude distribution
descriptors
pressure vessel
Opis:
In the paper, the results of investigations on the properties of acoustic emission signals generated in a tested pressure vessel are presented. The investigations were performed by repeating several Times the following procedure: an increase in pressure, maintaining a given pressure level, a further increase in pressure, and then maintaining the pressure at new determined level. During the tests the acoustic emission signals were recorded by the measuring system 8AE-PD with piezoelectric sensors D9241A. The used eight-channel measuring system 8AE-PD enables the monitoring, recording and then basic and advanced analysis of signals. The results of basic analysis carried out in domain of time and the results of advanced analysis carried out in the discrimination threshold domain of the recorded acoustic emission signals are presented in the paper. In the framework of the advanced analysis, results are described by the defined by the author descriptors with acronyms ADC, ADP and ADNC. Such description is based on identifying the properties of amplitude distributions of acoustic emission signals by assigning them the level of advancement. It is shown that for signals including continoues AE or single burst AE signals descriptions of such registered signals by means of ADC, ADP and ADNC descriptors and by Upp and Urms descriptors provide identical ordering of registered acoustic emission signals. For complex signals, the description using ADC, ADP and ADNC descriptors based on the analysis of amplitude distributions of recorded signals gives the order of signals with more accurate connection with deformational processes being sources of acoustic emission signals.
Źródło:
Archives of Acoustics; 2019, 44, 3; 493-503
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The 8AE-PD computer measurement system for registration and analysis of acoustic emission signals generated by partial discharges in oil power transformers
Autorzy:
Witos, Franciszek
Opilski, Zbigniew
Szerszeń, Grzegorz
Setkiewicz, Maciej
Powiązania:
https://bibliotekanauki.pl/articles/220623.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
acoustic emission
partial discharge
multichannel system
acoustic signal detection
acoustic signal processing
signal analysis
voltage preamplifier
Opis:
A computer measurement system, designed and built by authors, dedicated to location and description of partial discharges (PD) in oil power transformers examined by means of the acoustic emission (AE) method is presented. The measurement system is equipped with 8 measurement channels and ensures: monitoring of signals, registration of data in real time within a band of 25-1000 kHz in laboratory and real conditions, basic and advanced analysis of recorded signals. The basic analysis carried out in the time, frequency and time-frequency domains deals with general properties of the AE signals coming from PDs. The advanced analysis, performed in the discrimination threshold domain, results in identification of signals coming from different acoustic sources as well as location of these sources in the examined transformers in terms of defined by authors descriptors and maps of these descriptors on the side walls of the tested transformer tank. Examples of typical results of laboratory tests carried out with the use of the built-in measurement system are presented.
Źródło:
Metrology and Measurement Systems; 2019, 26, 2; 403-418
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Calibration and Laboratory Testing of Computer Measuring System 8AE-PD Dedicated for Analysis of Acoustic Emission Signals Generated by Partial Discharges Within Oil Power Transformers
Autorzy:
Witos, F.
Szerszeń, G.
Opilski, Z.
Setkiewicz, M.
Olszewska, A.
Duda, D.
Maźniewski, K.
Szadkowski, M.
Powiązania:
https://bibliotekanauki.pl/articles/177029.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
multichannel system
calibration
acoustic emission
partial discharge
power oil transformers
Opis:
In the paper, there are presented a general description of the constructed measuring system 8AE-PD, the results of calibration of this system by the Hsu-Nielsen method as well as the testing of the measuring system during recording signals generated by Hsu-Nielsen sources in a steel plate and a modeled partial discharge (PD) source. There is also presented the methodology of investigations by the calibrated acoustic emission method. The results of analyses of PD signals coming from the modeled sources are given. In particular, there are described the properties of acoustic emission (AE) signals generated by the PDs as well as the dependencies of the peak-to-peak voltage Umm, the RMS voltage Urms and the descriptors of acronyms ADP and ADC on the apparent charge Q introduced by the modeled PD source. There are determined the limit values of the apparent charge Q introduced by the modeled PD source for which the recorded signal is identified as originating from the PDS.
Źródło:
Archives of Acoustics; 2017, 42, 2; 297-311
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
An Enhanced Run-Length Encoding Compression Method for Telemetry Data
Autorzy:
Shan, Y.
Ren, Y.
Zhen, G.
Wang, K.
Powiązania:
https://bibliotekanauki.pl/articles/221755.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
multichannel acquisition system
high compression performance
run-length encoding with error parameter
oversampling
hardware implementation
Opis:
The telemetry data are essential in evaluating the performance of aircraft and diagnosing its failures. This work combines the oversampling technology with the run-length encoding compression algorithm with an error factor to further enhance the compression performance of telemetry data in a multichannel acquisition system. Compression of telemetry data is carried out with the use of FPGAs. In the experiments there are used pulse signals and vibration signals. The proposed method is compared with two existing methods. The experimental results indicate that the compression ratio, precision, and distortion degree of the telemetry data are improved significantly compared with those obtained by the existing methods. The implementation and measurement of the proposed telemetry data compression method show its effectiveness when used in a high-precision high-capacity multichannel acquisition system.
Źródło:
Metrology and Measurement Systems; 2017, 24, 3; 551-562
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Information Quantity Estimation of Multiplex Measurement Instrumentation
Ocena ilości informacji w wielokanałowych systemach pomiarowych
Autorzy:
Ivakhiv, O.
Powiązania:
https://bibliotekanauki.pl/articles/154617.pdf
Data publikacji:
2003
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
ilość informacji
wielokanałowy system pomiarowy
szybkość opracowania informacji
entropy
multichannel system
entropy estimation parameters
Opis:
The measurement instrumentation theory methodology makes it possible to take into acount both the metrological requirements to the restoration of measurement signal as well as to the measurement object dynamic properties.The information quantity, received from a certain measuring channel is defined as a difference between an initial (prior to the measuring) and a conditional (following the measuring) intropies which are based on the corresponding distributions laws. The measurement object information quantity received by the multiplex instrument with the needed accuracy is estimated.
Rozwój techniki komputerowej oraz informatyki spowodowały, z jednej strony, wprowadz. mikroprocesorów w strukturę przyrządu pomiarowego, a z drugiej strony - wykorzystywanie pojęć teorii informacji przy analizie procesów pomiarowych. Miernictwo coraz bardziej staje się dziedziną interdyscyplinarną. Z punktu widzenia informacyjnej teorii pomiaru można ocenić ilość informacji pobranej za pomocą przyrządu pomiarowego od obiektu badanego. W proponowanym artykule metodologia obliczenia ilości informacji dla przyrządu jednokanałowego została rozszerzona na wielokanałowy przyrząd czyli system pomiarowy. Przy założeniu modelu sygnału pomiarowego w postaci losowego stacjonarnego procesu z normalnym rozkładem gęstości prawdopodobieństwa i ograniczonym pasmem amplitudowym oraz z normalnym rozkładem błędu pomiarowego znaleziono zależności dla obliczenia ilości informacji. Te oceny pozwalają uwzględnic dynamiczne właściwosci obiektu badanego oraz metrologiczne kryteria oceny jego stanu. Zostały sformułowane również kryteria dotyczące szybkości przetwarzania tej informacji przez przyrząd cyfrowy. Ustalono, iż informacyjną efektywność można zwiększyć przez zmniejszenie wymagań co do szybkości przetwarzania informacji pomiarowej oraz mocy sygnału pomiarowego.
Źródło:
Pomiary Automatyka Kontrola; 2003, R. 49, nr 7-8, 7-8; 43-46
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
QRouteMe: A Multichannel Information System to Ensure Rich User-Experiences in Exhibits and Museums
Autorzy:
Gentile, A.
Andolina, S.
Massara, A.
Pirrone, D.
Russo, G.
Santangelo, A.
Sorce, S.
Trumello, E.
Powiązania:
https://bibliotekanauki.pl/articles/308473.pdf
Data publikacji:
2012
Wydawca:
Instytut Łączności - Państwowy Instytut Badawczy
Tematy:
exhibition
integration
multichannel information system
user experience
museums
personalization
Opis:
In this article the QRouteMe system is presented. QRouteMe is a multichannel information system built to ensure rich user experiences in exhibits and museums. The system starts from basic information about a particular exhibit or museum while delivering a wide user experience based on different distribution channels. The organization of the systems' components allow to build different solutions that can be simultaneously delivered on different media. A wide range of media from touch-screen installations to portable devices like smartphones have been used. The used devices can communicate each others to increase the usability and the user experience for the visitors. Another important feature of the system is the definition of an inexpensive auto-localization system based on fiduciary marks distributed all around the building. In this article the system is presented from an architectural and functional point of view. A case study and analysis of experimental results are also provided in a real environment where the system was deployed.
Źródło:
Journal of Telecommunications and Information Technology; 2012, 1; 58-66
1509-4553
1899-8852
Pojawia się w:
Journal of Telecommunications and Information Technology
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-6 z 6

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies