Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "multichannel integrated circuits" wg kryterium: Temat


Wyświetlanie 1-2 z 2
Tytuł:
Low-power low-area techniques for multichannel recording circuits dedicated to biomedical experiments
Autorzy:
Kmon, P.
Powiązania:
https://bibliotekanauki.pl/articles/201066.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
biomedical experiments
noise
multichannel integrated circuits
eksperymenty biomedyczne
hałas
wielokanałowe zintegrowane obwody
Opis:
This paper presents techniques introduced to minimize both power and silicon area of the multichannel integrated recording circuits dedicated to biomedical experiments. The proposed methods were employed in multichannel integrated circuit fabricated in CMOS 180nm process and were validated with the use of a wide range of measurements. The results show that both a single recording channel and correction blocks occupy about 0.061 mm2 of the area and consume only 8.5 μW of power. The input referred noise is equal to 4.6 μVRMS. With the use of additional digital circuitry, each of the recording channels may be independently configured. The lower cut-off frequency may be set within the range of 0.1 Hz–700 Hz, while the upper cut-off frequency, depending on the recording mode chosen, can be set either to 3 kHz/13 kHz or may be tuned in the 2 Hz–400 Hz range. The described methods were introduced in the 64-channel integrated circuit. The key aspect of the proposed design is the fact that proposed techniques do not limit functionality of the system and do not deteriorate its overall parameters.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2016, 64, 3; 615-624
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A system for 256-channel in vitro recording of the elect rophysiological activity of brain tissue
Autorzy:
Zoladz, M.
Powiązania:
https://bibliotekanauki.pl/articles/963870.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
multichannel measurement systems
neurobiological measurements
application specific integrated circuits
Opis:
A measurement system for 256-channel in vitro recordings of brain tissue electrophysiological activity is presented in the paper. The system consists of the brain tissue life support system, Microelectrode Array (MEA), conditioning Application Specific Integrated Circuits (ASIC’s) for signals conditioning, Digitizer and PC application for measurement data presentation and storage. The life support system keeps brain tissue samples in appropriately saturated artificial cerebrospinal fluid at a very stable temperature. The MEA consists of two hundred and fifty-six 40 μm diameter tip-shaped electrodes. The ASIC’s performs amplification and filtering of the 256-field and action potential signals. The Digitizer performs simultaneous data acquisition from 256 channels 14 kS/s sample rate and 12-bit resolution. The resulting byte stream is transmitted to the PC via USB (Universal Serial Bus). Preliminary tests confirm that the system is capable of keeping the extracted brain tissue active (hippocampal formation slices) and simultaneously to record action potentials, as well as local theta field potentials with very small amplitudes from multiple neurons.
Źródło:
Metrology and Measurement Systems; 2013, 20, 3; 371-384
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-2 z 2

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies