Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "mechanical-biological treatment plant" wg kryterium: Temat


Wyświetlanie 1-4 z 4
Tytuł:
Comparative analysis of selected wastewater treatment plants
Autorzy:
Nowakowska, Anita
Powiązania:
https://bibliotekanauki.pl/articles/1177394.pdf
Data publikacji:
2018
Wydawca:
Przedsiębiorstwo Wydawnictw Naukowych Darwin / Scientific Publishing House DARWIN
Tematy:
biological wastewater treatment plant
mechanical-biological wastewater treatment plant
wastewater
wastewater management
Opis:
The article presents the classification of wastewater treatment plants and indicates the types of processes occurring during wastewater treatment. The purpose of the article is to get acquainted with the functioning as well as technical and economic differences of biological and mechanical-biological wastewater treatment plant. The author also made a comparative analysis containing a list of wastewater treatment efficiency in the presented treatment plants, as well as compared economic aspects necessary for the operation of these treatment plants.
Źródło:
World Scientific News; 2018, 104; 359-374
2392-2192
Pojawia się w:
World Scientific News
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of post-sewage waters on relations between exchangeable cations in soils
Autorzy:
Dechnik, I
Filipek, T.
Powiązania:
https://bibliotekanauki.pl/articles/1449943.pdf
Data publikacji:
2001
Wydawca:
Polska Akademia Nauk. Instytut Agrofizyki PAN
Tematy:
post-sewage water
relationship
soil
municipal waste
cation
biogenic component
soil property
eroded soil
degraded ecosystem
mechanical-biological treatment plant
anthropogenic ecosystem
sewage
Opis:
Research was carried out on the basis of investigations from the years 1996-1998 on the so-called monoliths in the soils derived from loess formations. Properties of those formations were differentiated by landscape and processes of water erosion. It was found out that post-sewage waters (waters received after sewage treatment) from a mechanical-biological sewage treatment plant have a more favourable influence on both the value of acidification indexes and relations between cations in the soils than solid mineral salts.
Źródło:
Acta Agrophysica; 2001, 51; 29-35
1234-4125
Pojawia się w:
Acta Agrophysica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The effect of heavy precipitation on the infiltration and inflow into small sewage treatment plants in 2010
Autorzy:
Kaczor, G.
Powiązania:
https://bibliotekanauki.pl/articles/60233.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Stowarzyszenie Infrastruktura i Ekologia Terenów Wiejskich PAN
Tematy:
heavy rainfall
infiltration
inflow
small sewage treatment plant
sewage treatment plant
sewer system
weather
treatment plant
Malopolska voivodship
Krakow city
mechanical treatment plant
biological treatment plant
modernization
Opis:
The aim of the study was to determine the extent to which heavy rainfall, that occurred in 2010, affected the infiltration into the selected sewage treatment plants in the Małopolskie voivodeship. The research was conducted in four separate sewer systems, located in poviats adjacent to the city of Kraków, discharging sewage to mechanical-biological treatment plants with a capacity below 1000 m3•d-1. The amount of sewage and extraneous water in the average wet year (2008) were used as control. As a result of heavy precipitation in 2010 the sewer system A received 18 539 m3 more extraneous water than in 2008 (increase by 343%), the sewer sys-tem B - 22 822 m3 (increase by 163%), the sewer system C - 109 715 m3 (increase by 248%) and the sewer system D - 30 796 m3 (increase by 303%). Heavy precipitation in 2010 caused the increase of infiltration and inflow by 264% on average in all studied sewer systems compared to the average wet year. As the result of precipitation, whose annual total in 2010 was higher by 65% than the normal value in 2008, there was an increase in the annual share of extraneous water from 5.3 to 19.7% depending on the facility. The volume of extraneous water, which was discharged into the studied treatment plants in 2010 (the period of heavy rainfall), constituted the following share of the annual value: in the sewer system A - 41.3%, in the sewer system B - 21.2%, in the sewer system C - 14.4%, in the sewer system D - 22.9%. Assuming the average gross amount of 3 PLN paid for treatment of 1 m3 of sewage, cost of extraneous water disposal in 2010 amounted from 78 533 PLN to 552 165 PLN, depending on the facility. The results obtained in the present study suggest that eliminating or reducing infiltration and inflow into the analyzed sewer systems would allow for large financial savings associated with reducing costs both for their transport and treatment as well as for modernization of facilities to enhance their hydraulic eapacity.
Źródło:
Infrastruktura i Ekologia Terenów Wiejskich; 2011, 12
1732-5587
Pojawia się w:
Infrastruktura i Ekologia Terenów Wiejskich
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Pollutants Removal Efficiency in The Hydroponic Lagoon of The Wastewater Treatment Plant
Autorzy:
Jakubaszek, Anita
Powiązania:
https://bibliotekanauki.pl/articles/27314840.pdf
Data publikacji:
2022
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
wastewater treatment plant
wastewater treatment
hydroponic lagoon
mechanical-biological wastewater
oczyszczalnia ścieków
oczyszczanie ścieków
laguna hydroponiczna
oczyszczanie mechaniczno-biologiczne
Opis:
Wastewater treatment in semi-natural systems, such as a hydroponic lagoon operating as the third stage of treatment, is becoming more and more popular because of the efficiency of organic matter and nutrient removal. The article presents an analysis of the efficiency of pollutant removal at the mechanical-biological wastewater treatment plant in Gronów with a capacity of Qd = 1125m3/day and a load of 9375 PE. The wastewater treatment plant operates on the basis of activated sludge and biomass settling technology on submerged flow beds. The treatment plant is characterized by a very high variability of wastewater inflow during the year due to periodic inflow of wastewater from tourist resorts in Łagów. The average efficiency of removing pollutants from wastewater was: BOD5 - 98.5%, COD - 92.8%, total suspended solids - 93.2%, total nitrogen - 86.1% and total phosphorus - 69.5%. The study showed that the use of a hydroponic lagoon in the technological system improved the efficiency of wastewater treatment by 1.7% for BOD5, 0.9% - COD, total suspended solids by 4.3%, 6.4% for total nitrogen and total phosphorus - 3.3%.
Źródło:
Civil and Environmental Engineering Reports; 2022, 32, 4; 293--305
2080-5187
2450-8594
Pojawia się w:
Civil and Environmental Engineering Reports
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-4 z 4

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies