Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "measurement station" wg kryterium: Temat


Wyświetlanie 1-6 z 6
Tytuł:
On Great Lagoon (Szczecin Lagoon) water salinity - once again
O zasoleniu wody w Wielkim Zalewie Szczecińskim raz jeszcze
Autorzy:
Poleszczuk, G.
Niedzwiecki, E.
Wolnomiejski, N.
Bucior, A.
Powiązania:
https://bibliotekanauki.pl/articles/85121.pdf
Data publikacji:
2005
Wydawca:
Akademia Pomorska w Słupsku
Tematy:
Szczecin Lagoon
water salinity
fresh water
ionic composition
measurement station
water sample collection
bottom water
salinity level
surface water
salinity degree
chloride concentration
marine-inland water
mineralization
Opis:
Between May and October of 2003, mineral composition of surface (0.5 m deep) and bottom (5.0 meters) waters, at measurement stations in north-western and south-eastern parts of Great Lagoon (Szczecin Lagoon), have been studied. Total concentrations of ionic macrocomponents: Na+, K+, Ca2+, Mg2+, Cl-, HCO3 - , SO4 2- have been determined. Differentiation of ionic composition and changing level of concentrations of ionic macrocomponents in waters, depending on location of measurement station, depth of water sample collection and time of examination, have been proved. Bottom waters in south-eastern part of Great Lagoon had highest salinity level, whereas surface waters in the same location had lowest degree of salinity. Taking into consideration relatively small number of measurements, authors of present paper regard outlined investigations as diagnostic and obtained conclusions as preliminary ones. Towards substantial variability in ionic composition and magnitudes of concentrations, it is practically impossible to forecast and define values of concentrations of individual ionic components and general salinity degrees, basing on chlorides concentrations, what was often pursued, until now.
W roku 2003 w okresie od maja do października oznaczano stężenia ogólne makroskładników jonowych (Na+, K+, Ca2+, Mg2+, Cl-, SO4 2-, HCO3 - ) i na podstawie tych oznaczę obliczano przybliżone wartości zasolenia wód Wielkiego Zalewu (Zalew Szczeciński). Próby wody do badań pobierano w miejscach stacji pomiarowych zlokalizowanych w północnozachodniej (stacja nr 1) i w południowo-wschodniej (stacja nr 2) czesciach Zalewu. Wodę czerpano z warstwy powierzchniowej (z głębokości ok. 0,5 m) i naddennej (z głębokości ok. 5,0 m). Próby wody do badań pobierano z częstotliwością raz w miesiącu. Ze względu na niedużą liczbę pomiarów, badania te traktowano jako rozpoznawcze, zaś ich wyniki – jako ustalenia wstępne. Badania potwierdziły znany wcześniej fakt znacznego zróżnicowania składu jonowego i stężenia substancji mineralnych w wodach Wielkiego Zalewu w zależności od miejsca poboru prób i głębokości, z jakiej próby pobierano. Wody naddenne były wyraźnie bardziej zasolone od wód powierzchniowych i to na obu ww. stacjach, przy czym – co było dość zaskakujące – bardziej zasolone były wody naddenne w południowowschodniej części Zalewu. Jeżeli chodzi o wody powierzchniowe, to – jak było też wiadome z wcześniejszych badań – bardziej zasolone były wody w północnej części Zalewu. Z równań regresji liniowej, ujmujących zależności pomiędzy wartościami stężeń poszczególnych składników mineralnych a stężeniami jonów chlorkowych, a także z równań ujmujących zależności pomiędzy łącznymi masami makroskładników jonowych zawartych w 1 dm3 wód (oznaczanymi w tekście pracy jako ż ion m ) – także ze stężenia jonów chlorkowych, w wodach na obu stacjach i w obu badanych warstwach wynika, że istotne statystycznie korelacje uzyskano jedynie dla stężeń Na+ i K+ oraz Emion – przy czym wartości stałej i współczynnika w równaniu regresji liniowej – dla każdej z 4 kategorii wód (2 stacje × 2 warstwy wody) – były wyraźnie różne. Związane to było z zachodzeniem w ekosystemie Zalewu (wzdłuż drogi spływu wód w dół estuarium) przemian prowadzących do zmiany składu chemicznego wód. Ustalenia te wskazują, że wyniki obliczeń składu jonowego wód i zasolenia wykonywane na podstawie ogólnych (uśrednionych) dla całego Wielkiego Zalewu równań korelacyjnych ujmujących zależność pomiędzy stężeniami wybranych składników makrojonowych wód oraz ich ogólnego zasolenia od stężenia chlorków mogą prowadzić do otrzymania wyników znacznie różniących się od wartości rzeczywistych. W tej sytuacji jedynym i najpewniejszym sposobem na ustalenie składu jonowego i wartości stężeń wybranych makroskładników jonowych oraz zasolenia ogólnego wód jest wykonanie odpowiednich oznaczeń stężeń wszystkich składników makrojonowych wód Wielkiego Zalewu.
Źródło:
Baltic Coastal Zone. Journal of Ecology and Protection of the Coastline; 2005, 09
1643-0115
Pojawia się w:
Baltic Coastal Zone. Journal of Ecology and Protection of the Coastline
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Determination of the deviation of the on-board computer in the vehicle when determining the average fuel consumption
Autorzy:
Loman, Michal
Šarkan, Branislav
Powiązania:
https://bibliotekanauki.pl/articles/1838343.pdf
Data publikacji:
2021
Wydawca:
Sieć Badawcza Łukasiewicz. Przemysłowy Instytut Motoryzacji
Tematy:
fuel consumption
vehicle
onboard computer
service station
measurement uncertainty
Opis:
Fuel consumption measurement itself is a demanding process and it is difficult to determine the exact consumption of a vehicle. Fuel consumption can be determined in various ways. One way to determine consumption is through driving tests. We know several types of driving tests. Nowadays, most vehicles and all new vehicles can provide a wealth of data to the driver directly during vehicle operation. One of them is the data on the consumption of the vehicle also through the on-board computer located in the vehicle. The information provided to the driver may not reflect reality. In most cases, they are inaccurate and do not correspond to reality. Therefore, the subject of the research will be to verify the accuracy of the provided data on vehicle consumption by the on-board computer. The aim of the research will be to determine the extent to which consumption data are true. Vehicle consumption, as well as measurements are performed on one vehicle in every day traffic. This will ensure that it is possible to compare the measured data with each other.
Źródło:
Archiwum Motoryzacji; 2021, 91, 1; 25-35
1234-754X
2084-476X
Pojawia się w:
Archiwum Motoryzacji
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Description of Measurements on Biogas Stations
Autorzy:
Novosad, L.
Hradilek, Z.
Powiązania:
https://bibliotekanauki.pl/articles/136222.pdf
Data publikacji:
2016
Wydawca:
EEEIC International Barbara Leonowicz Szabłowska
Tematy:
biogas station
power analysis
measurement database
black out
co-generation units
distribution grid
Opis:
This paper focuses mainly on performance analysis for three biogas stations situated within the territory of the Czech Republic. This paper contains basic details of the individual biogas stations as well as description of their types. It also refers to the general description of the measurement gauge involved, with specifications of its potential use. The final part of this paper deals with the analysis of course data obtained, with special regard to voltage, current, active power and reactive power data.
Źródło:
Transactions on Environment and Electrical Engineering; 2016, 1, 3; 16-20
2450-5730
Pojawia się w:
Transactions on Environment and Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of development tendencies of metrological technologies to control rangefinders of an electronic distance measurement instruments
Autorzy:
Burachek, Vsevolod
Khomushko, Dmytro
Tereshchuk, Oleksiy
Kryachok, Sergíy
Belenok, Vadim
Powiązania:
https://bibliotekanauki.pl/articles/43852820.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Czasopisma i Monografie PAN
Tematy:
kalibrowanie
dalmierz
błąd pomiaru odległości
calibration
rangefinder
electronic distance measurement
reference linear station
root mean square
error distance measurement
Opis:
The article analyses the development of metrological control technologies for electronic distance measurement rangefinders to determine their main characteristic of accuracy – the root mean square error of distance measurement. It is established that the current reference linear bases are reliable and serve as the main means of transmitting a unit of length from the standards to the working means of measuring length. The article describes the existing linear reference bases and specifies their accuracy and disadvantages. It is concluded that the disadvantages of linear reference bases are deprived of the reference linear bases built in special laboratories. They use distances measured by the differential method with laser interferometers as reference distances. The application of such technology allowed to automate the processes of measurements and calculations. There is development of fibre-optic linear bases, in which optical fibres of known length are used as model lines. The article offers a new technical solution – a combination of fiber-optic and interference linear bases, which allows to qualitatively improve the system of metrological support of laser rangefinders. This is achieved by having a fiber-optic unit, which allows you to create baselines of increased length, while ensuring small dimensions of the baseline, and relative interference base, which provides high accuracy of linear measurements and does not require calibration of the base with a precision rangefinder, which eliminates several difficulties associated with changes in the refractive index, makes measurements independent of the wavelength of the radiation source and almost independent of the ambient temperature.
Źródło:
Advances in Geodesy and Geoinformation; 2022, 71, 1; art. no. e13, 2022
2720-7242
Pojawia się w:
Advances in Geodesy and Geoinformation
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Measuring displacements in engineering structures by means of a coordinate laser station
Badanie przemieszczeń obiektów inżynierskich z wykorzystaniem stacji laserowej
Autorzy:
Sztubecki, J.
Bujarkiewicz, A.
Sztubecka, M.
Powiązania:
https://bibliotekanauki.pl/articles/396253.pdf
Data publikacji:
2016
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
displacement measurement
laser station
engineering structures
dynamic response
bridge structures
pomiar przemieszczeń
stacja laserowa
monitorowanie obiektów inżynierskich
dynamika konstrukcji
konstrukcje mostowe
Opis:
The application of geodetic methods to examine structures consists in the determination of their displacements relative to an established geodetic reference datum or in the definition of the geometry of their individual components. Such examinations form a picture of changes happening between specific points in time. Modern measurement technologies used in geodetic engineering enable undertaking more and more challenging measurements with increasing accuracy. The purpose of this article is to present a measurement technique involving a Leica TDRA 6000 total station to measure displacements in engineering structures. The station features a direct drive technology to achieve an accuracy of 0.25 mm in 3-dimensional measurements. Supported by appropriate software, the unit makes a perfect instrument for the monitoring of civil engineering structures. The article presents the results of measurement of static and dynamic displacements in a few engineering structures. The measurements were carried out both in laboratory conditions and on actual, operated civil engineering structures.
Badania konstrukcji metodami geodezyjnymi polegają na wyznaczeniu jej przemieszczeń względem przyjętego układu odniesienia lub na określeniu geometrii poszczególnych elementów. Dają one obraz zmian pomiędzy przyjętymi momentami czasu. Nowoczesne technologie pomiarowe stosowane w geodezji pozwalają na realizowanie coraz bardziej skomplikowanych zadań pomiarowych oraz uzyskiwanie coraz większych dokładności. Celem artykułu jest przedstawienie technologii pomiaru przemieszczeń konstrukcji inżynierskich z wykorzystaniem stacji laserowej Leica TDRA 6000. Stacja ta wyposażona jest w technologię napędu bezpośredniego, pozwalającą na uzyskiwanie dokładności pomiaru 3D na poziomie 0,25 mm. Wraz z odpowiednim oprogramowaniem jest doskonałym narzędziem umożliwiającym monitorowanie obiektów inżynierskich. Zaprezentowano wyniki pomiarów przemieszczeń statycznych oraz dynamicznych kilku konstrukcji inżynierskich. Pomiary wykonywano zarówno w warunkach laboratoryjnych jaki na istniejących i eksploatowanych obiektach.
Źródło:
Civil and Environmental Engineering Reports; 2016, No. 23(4); 145-160
2080-5187
2450-8594
Pojawia się w:
Civil and Environmental Engineering Reports
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
How the axial flux of an induction motor can be used?
Autorzy:
Petryna, Janusz
Powiązania:
https://bibliotekanauki.pl/articles/93080.pdf
Data publikacji:
2019
Wydawca:
Państwowa Wyższa Szkoła Zawodowa w Tarnowie
Tematy:
axial flux
rotor cage damage
inter-turn short circuit
load torque
rotational speed measurement
induction motor
testing station
contactless measurement
strumień osiowy
uszkodzenie klatki wirnika
zwarcie między zwrotami
moment obciążenia
pomiar prędkości obrotowej
silnik indukcyjny
stacja testowa
pomiar bezdotykowy
Opis:
The article contains the results of research within the project to apply unipolar (axial) flux to obtain diagnostic signals carrying the information of: electrical asymmetries of machinery (inter-turn stator short-circuits, cage damages); rotational speed of the rotor and load torque. Inter-turn stator short-circuits can be detected both at starting process time (when they appear most often), as well as in steady states. Detection of rotor cage defects in steady states has a character of a comparative study, and over time, as the defects develop. For standard drives that are powered from the network and work in open systems, by measuring the voltage following a unipolar flux, it is possible to make measurement and recording of motor speed, which usually is almost never provided under industrial conditions. The study shows that a simple in its construction, cheap coil can be a very useful diagnostic tool. The measurements were carried out at the laboratory and motor workplace in the power plant, while in the test station, during the loading, characteristics illustrating the dependence of the torque on the axial flux and on the rotational speed were obtained. A way of using a single measurement to estimate the torque has been proposed. The method is relatively simple to implement and allows for a fully non-invasive determination of the load torque.
Źródło:
Science, Technology and Innovation; 2019, 5, 2; 34-43
2544-9125
Pojawia się w:
Science, Technology and Innovation
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-6 z 6

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies