Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "maszyny elektryczne" wg kryterium: Temat


Tytuł:
The analytical approaches to calculation of electric machines on the basis of the annular domains boundary problems solution by the method of Fourier variables separation
Analityczne podejście do obliczania maszyn elektrycznych w oparciu o rozwiązanie problemów brzegowych domen pierścieniowych metodą rozdziału zmiennych Fouriera
Autorzy:
Afanasjev, A.A.
Babak, A.G.
Nikolaev, A.V.
Powiązania:
https://bibliotekanauki.pl/articles/159018.pdf
Data publikacji:
2004
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Elektrotechniki
Tematy:
maszyny elektryczne
szereg Fouriera
Opis:
The air gap, with double-sided stairstep jaggies being two-downlink area, can be conformally imaged as circular ring. Traditionally this procedure executes approximately with the help of Carter factors. Cross sections of the stator and rotor cores also have the form of rings. The rotating magnetic field in the locations of conductors (in slots, windows between poles) can be presented by the sum of potential and some adding (easily calculated) fields. The localisation of an adding field in the location of conductors requires arrangement on a part of boundary of each slot (at the bottom or in the wedge part) infinitely thin current layers, the joint currents of them are equal to full currents of slots. Usage of scalar magnetic potentials (SMP) of current layers allows to receive the analytical solution of Dirichlet problem for circular rings of three mentioned environments (air gap, magnetic stator core and rotor) assuming its magnetic permeabilities are constant. For the sake of greater generality of the problem we assume that the core of the rotor is performed from massive steel. The selection of this material does the mathematical model more universal, as at transition to high enough values of magnetic permeability and resistivity the massive environment gains properties of laminated steel. SMP of current layers of stator windings and rotor are submitted by Fourier series. The parameters of an electromagnetic field in a solid rotor (radial and tangential component of flux density, current density and power loss) are obtained on the basis of the analytical solution of Bessel differential equation for a vector magnetic potential by a method of variables separation and are submitted by appropriate Bessel and Kelvin functions. With reference to an asynchronous motor with a solid rotor the performance data are calculated and compared with the test results. The changes of magnetic permeability in steel of a rotor are taken into account by splitting it on concentric rings, in each of which the permeability is constant.
Szczelina powietrzna obustronnie uzębiona, będąca obszarem przejścia, może być konformalnie odwzorowana jako pierścień kołowy; tradycyjnie tę procedurę przeprowadza się w przybliżeniu przy pomocy współczynników Cartera. Przekroje poprzeczne rdzeni stojana i wirnika mają również kształt pierścieni. Wirujące pole magnetyczne w obszarach przewodów (w żłobkach, w oknach między biegunami) może być przedstawione przez sumę pól potencjału i pewnego dodatkowego (łatwego do obliczenia) pola. Umieszczenie dodatkowego pola w miejscu, gdzie są przewody wymaga rozmieszczenia w brzegowej części żłobka (w części przy dnie lub klinie) nieskończenie cienkich warstw prądu tak, aby łączne prądy były równe pełnym prądom żłobków. Użycie skalarnych magnetycznych potencjałów (SMP) warstw prądu pozwala otrzymać analityczne rozwiązanie problemu Dirichleta dla kołowych pierścieni wspomnianych trzech obszarów (szczelina powietrzna, rdzeń magnetyczny stojana i wirnika) przy założeniu, że przenikalności magnetyczne są stałe. Dla uzyskania lepszego uogólnienia problemu zakładamy, że rdzeń wirnika jest wykonany z litej stali. Wybranie tego materiału czyni model matematyczny bardziej uniwersalnym, gdyż przy przejściu do wysokich wartości przenikalności magnetycznej i rezystywności, materiał lity uzyskuje własności stali blachowanej. SMP warstw prądu uzwojeń statora i wirnika przedstawia się za pomocą szeregów Fouriera. Parametry pola elektromagnetycznego w litym wirniku (promieniowa i styczna składowa indukcji, gęstość prądu i straty mocy) otrzymuje się na podstawie analitycznego rozwiązania różniczkowych równań Bessela dla wektorowego potencjału magnetycznego metodą rozdziału zmiennych i przedstawia się je przez odpowiednie funkcje Bessela i Kelvina. Obliczone dane dla silnika asynchronicznego z litym wirnikiem porównano z wynikami prób. Zmiany przenikalności magnetycznej w stali wirnika uwzględniono przez podzielenie go na współosiowe pierścienie o stałej przenikalności w każdym z nich.
Źródło:
Prace Instytutu Elektrotechniki; 2004, 220; 41-78
0032-6216
Pojawia się w:
Prace Instytutu Elektrotechniki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Determination of the iron losses and rotor additional losses in electric machines by advanced methods
Wyznaczenie zaawansowanymi metodami strat w rdzeniu i strat dodatkowych w wirniku w maszynach elektrycznych
Autorzy:
Schuffenhauer, U.
Kuß, H.
Powiązania:
https://bibliotekanauki.pl/articles/159432.pdf
Data publikacji:
2005
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Elektrotechniki
Tematy:
metoda pomiaru
straty
rdzeń
wirnik
maszyny elektryczne
Opis:
New demands of modern electric drives cause ever new machine designs. Simultaneous the utilization is increasing. This induces, that usual algorithms for the loss calculation are not valid any more in the full extent. The construction of prototypes should be dispensed with, so accurate calculation methods are necessary. In this contribution methods are presented for calculation of the iron losses of electrical machines. In addition to the short consideration of conventional analytical methods new procedures are regarded, with which both the losses through harmonics and the losses in the rotor and inactive parts of the magnetic circuit can be computed by utilization of the results of static or transient FEM computations.
Nowe wymagania stawiane napędom elektrycznym powodują, że zachodzi potrzeba wykonywania nowych projektów. Jednocześnie zwiększa się stosowanie procesów symulacyjnych. To sprawia, że zwykłe algorytmy obliczające straty nie są wystarczające. Względy oszczędnościowe powodują, że wskazane jest obywanie się bez konstrukcji prototypów dlatego też dokładne metody obliczeń są konieczne. W artykule przedstawiono metody obliczające straty w rdzeniu maszyn elektrycznych. Dodatkowo wzięto pod uwagę klasyczne metody analityczne oraz nowe procedury, w których straty od harmonicznych i straty w wirniku oraz w elementach nieaktywnych obwodu magnetycznego mogą być obliczane przy zastosowaniu metody elementów skończonych.
Źródło:
Prace Instytutu Elektrotechniki; 2005, 223; 91-112
0032-6216
Pojawia się w:
Prace Instytutu Elektrotechniki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Condition monitoring of large electrical machines
Monitorowanie stanu wielkich maszyn elektrycznych
Autorzy:
Göl, Ö.
Nafalski, A.
Powiązania:
https://bibliotekanauki.pl/articles/2056345.pdf
Data publikacji:
2007
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
maszyny elektryczne wielkie
monitorowanie stanu maszyn elektrycznych
Opis:
Large electrical machines, both synchronous and asynchronous, are the mainstay in critical installations both to generate electricity and to provide motive power for essential services in power stations, water supply, manufacturing plant, food industries and sewerage treatment. Although "out of sight, out of mind" for the majority in today's society, their role is undeniably critical to the reliable provision of vital services. Faults are costly, if not fatal. This paper discusses issues related to condition monitoring of industrial motors, focussing on types of fault possible and associated symptoms. It solicits the bases for devising an effective condition monitoring scheme.
Wielkie maszyny elektryczne, zarówno synchroniczne jak i asynchroniczne są podstawowymi urządzeniami strategicznych instalacji wytwarzających energię elektryczną, dostarczających wodę, usuwających ścieki, pracują w przemyśle przetwórczym, spożywczym itd.. I choć często niezauważalne, odgrywają istotną rolę w zapewnieniu ciągłości podstawowych usług. Usterki i uszkodzenia są bardzo kosztowne, jeśli nie fatalne. W artykule omówiono zagadnienia związane z monitorowaniem stanu silników przemysłowych, omówiono różne możliwe uszkodzenia oraz symptomy ich zaistnienia. Artykuł stanowi podstawę dla efektywnego systemu monitorowania stanu maszyn.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2007, 77; 197-202
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Simulation and laboratory research of permanent magnet DC-machine
Badania laboratoryjne i symulacyjne maszyny prądu stałego wzbudzanej magnesami trwałymi
Autorzy:
Matras, A.
Powiązania:
https://bibliotekanauki.pl/articles/320199.pdf
Data publikacji:
2005
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
maszyny elektryczne
magnesy trwałe
electrical machines
permanent magnets
Opis:
In the paper calculation results of the magnetic field distribution for the DC-machine with permanent magnet is presented. The calculation is performed by finite element method. The results are contained the distributions of magnetic potential and the flux density in the whole regarding area and the mechanical quantity - radial and tangential stress componet. The mentioned calculations are verified by measurements of the flux density distribution in the air-gap at no-load and rated-load state.
W artykule przedstawiono wyniki obliczeń rozkładu pola magnetycznego dla maszyny prądu stałego wzbudzanej magnesami trwałymi. Obliczenia zostały wykonane metodą elementów skończonych. Rezultatami są rozkłady potencjału magnetycznego i indukcji magnetycznej w rozpatrywanym obszarze oraz wielkości mechaniczne - składowe normalne i styczne naprężeń. Wspomniane wyniki obliczeń zostały zweryfikowane pomiarami rozkładu indukcji magnetycznej w szczelinie powietrznej w stanie jałowym i przy znamionowym obciążeniu.
Źródło:
Elektrotechnika i Elektronika; 2005, 24, 1; 69-74
1640-7202
Pojawia się w:
Elektrotechnika i Elektronika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The influence of pulse stress on main-wall insulation of electric rotating machines
Wpływ impulsów napięciowych na izolację główną wirujących maszyn elektrycznych
Autorzy:
Mentlik, V.
Pihera, J.
Tábořik, O.
Trnka, P.
Powiązania:
https://bibliotekanauki.pl/articles/2056352.pdf
Data publikacji:
2007
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
maszyny elektryczne
izolacja
metoda impulsowa
diagnostyka maszyn elektrycznych
starzenie izolacji
Opis:
The diagnostics of insulating system of electric machines under pulse stress is at the present one of the most focused fields. The converters produce repetitive pulses with the high level of voltage rise fronts (slew rates). Rise fronts attain values of up to the tens of kilovolts per microsecond and voltage pulse repetition frequency up to some tens of kilohertz. However, this technology is an advantage for a drive control; the voltage waveforms generated by power frequency converters may significantly affect the reliability of the electric motor insulation systems. To improve understanding of the processes in the electrical insulation materials during the pulse voltage aging, it is necessary to monitor values of the electric parameters within a pulse stress aging process. For the studying of the main-wall insulation material pulse voltage aging processes there were chosen these electrical parameters: the dissipation factor, capacity, absorption and resorption currents, corona inception voltage (CIV) and partial discharges (PD) activity level. These parameters are easily detectable and their development characteristics are very well known in the terms of sinusoidal voltage aging process. This paper presents experimentally measured data of the observed electric parameters during the pulse and sinus voltage aging. The difference between the sinusoidal voltage aging and pulse voltage aging time dependencies is shown as well observable in this paper as well.
Diagnostyka układu izolacji maszyn elektrycznych metodą impulsową nabiera coraz większego znaczenia. Przemienniki wytwarzają powtarzające się impulsy o wielkiej stromości narastania napięcia osiągające wartość kilkudziesięciu kilowoltów na mikrosekundę i częstotliwość dziesiątków kiloherców. I choć technologia ta ma wyraźne zalety dla regulacji prędkości obrotowej napędów, fale napięciowe generowane przez przemienniki mogą znacząco wpływać na trwałość układu izolacyjnego maszyny. Dla poprawy zrozumienia procesów starzeniowych układu izolacyjnego zachodzących w trakcie impulsów napięciowych koniecznym jest monitorowanie wartości elektrycznych występujących w czasie trwania impulsu. Dla analizowania starzenia izolacji głównej wybrano takie parametry jak: współczynnik rozproszenia, pojemność, prąd absorpcji i resorbcji, napięcie początkowe korony, i poziom wyładowań niezupełnych. Te parametry są łatwe do pomiaru a ich przebiegi są dobrze znane dla procesów starzeniowych od napięcia sinusoidalnego. W artykule przedstawiono zależności czasu starzenia układu izolacji skutkiem działania napięcia sinusoidalnego i starzenia izolacji od impulsów napięciowych.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2007, 77; 43-46
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Interaction aspects of pulse stress and insulation systems
Wpływ zasilania impulsowego na układy izolacyjne maszyn elektrycznych
Autorzy:
Mentlik, V.
Kučerowá, E.
Boček, V.
Šebik, P.
Trnka, P.
Powiązania:
https://bibliotekanauki.pl/articles/1374816.pdf
Data publikacji:
2005
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
maszyny elektryczne
zasilanie impulsowe
układy izolacyjne
izolacja elektryczna
materiały izolacyjne
Opis:
W ostatnich 20 latach w dziedzinie przemysłowych układów sterowania zaobserwowano bardzo szybki rozwój w zakresie technologii napędu o regulowanej prędkości. Jednocześnie zaobserwowano, że przebiegi czasowe napięć generowanych przez przekształtniki częstotliwości mogą niekorzystnie wpłynąć na niezawodność i żywotność układów izolacyjnych w silnikach elektrycznych. Problemy związane z przepięciami występującymi w napędach z długim okablowaniem, wywołanymi krótkimi czasami narastania zboczy prostokątnych impulsów napięciowych stały się w ostatniej dekadzie istotną dziedziną badań. Ponadto znany jest również problem prądów łożyskowych. Obok asymetrii magnetycznej istnieją także inne przyczyny wywołujące prądy łożyskowe, takie jak np. niezamierzone podanie potencjału napięciowego na wał silnika, kumulowanie się ładunku elektrostatycznego czy napięcia współbieżne wytwarzane przez niesymetryczne zasilanie uzwojeń silników. Każda z wymienionych przyczyn może wywołać prądy łożyskowe i w efekcie uszkodzenie łożysk. Ostatnio główną przyczyną prądów łożyskowych i uszkodzeń łożysk stały się napięcia współbieżne o wysokiej częstotliwości i dużych przyrostach dv/dt, występujące przy zasilaniu silników indukcyjnych z przekształtników częstotliwościowych. Niniejszy artykuł dotyczy powyższych zagadnień. Przedstawiono w nim wyniki badań eksperymentalnych wpływu złożonych warunków napięciowych na żywotność wybranych materiałów izolacyjnych stosowanych w maszynach elektrycznych wirujących. Zauważono, że dla niektórych materiałów izolacyjnych przy zasilaniu z falowników PWM następuje zmniejszenie czasu zużycia izolacji nawet o 80%.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2005, 71; 83-86
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Derating of an Induction Machine under Voltage and Frequency Deviation
Obciążalność mocą silnika indukcyjnego w warunkach występowania odchylenia napięcia i częstotliwości
Autorzy:
Pepliński, M.
Powiązania:
https://bibliotekanauki.pl/articles/342346.pdf
Data publikacji:
2018
Wydawca:
Uniwersytet Morski w Gdyni. Wydawnictwo Uniwersytetu Morskiego w Gdyni
Tematy:
electric machines
induction motors
heating
maszyny elektryczne
silnik indukcyjny
nagrzewanie
Opis:
One of the most frequently appearing power quality disturbances is voltage deviation. In addition in autonomic power systems, e.g. in ships, frequency deviation often occurs. It causes additional power losses and increase in thermal loads of induction machines. This paper deals with an effect of voltage and frequency deviation on derating.
Jednym z najczęściej występujących zaburzeń jakości napięcia jest odchylenie jego wartości skutecznej. Ponadto w autonomicznych systemach elektroenergetycznych, np. na statkach, występują często odchylenia częstotliwości. Zaburzenia te powodują w silnikach indukcyjnych dodatkowe straty mocy i zwiększenie ich obciążalności cieplnej. Artykuł dotyczy wpływu odchyleń wartości skutecznej napięcia i częstotliwości na obniżenie wartości dopuszczalnej mocy i momentu silnika indukcyjnego.
Źródło:
Zeszyty Naukowe Akademii Morskiej w Gdyni; 2018, 106; 60-70
1644-1818
2451-2486
Pojawia się w:
Zeszyty Naukowe Akademii Morskiej w Gdyni
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Determining the Correction Factors of OverheadConductors in 6kV Mining System of QuangNinh, VietNam with the Consideration of Power Harmonic Impact
Autorzy:
Giang, Vu Hoang
Thanh, Le Xuan
Powiązania:
https://bibliotekanauki.pl/articles/25212175.pdf
Data publikacji:
2023
Wydawca:
Polskie Towarzystwo Przeróbki Kopalin
Tematy:
medium voltage grid
skin effect
correction factor
algorithm
górnictwo
Wietnam
maszyny elektryczne
Opis:
Understanding the impact of power harmonic on energy transmission play an important role not only in the operation process but also in the designing procedure of MV grid. In 6kV mining grids of Vietnamese coal mines, because of rapidly utilizing the power electronic machines, the power quality violation occurs very frequently. This lead to many disadvantages such as: the increase of power losses, voltage distortion, over-heating in transformers and conductors. Moreover, the presence of power harmonic bring the bad impact of skin effect and proximity on conductor including overhead-conductors and cables. The actual operation exhibits that the losses of transmission lines are approximately over 50% of total network losses. If there are power quality violation, this amount could be higher. Basing on investigating the fact of power harmonic violations in 6kV grid of both underground and surface mines, the paper will analyze this kind of impact. An algorithm relying on Matlab programming is used to calculate the energy losses. Results are compared with on-site measurement datas and lab-measurement to obtain series of correction factors corresponding to individual line’s cross section. The outcomes of research could be applicable for power utilities to have better analysis in the designing stage of mining MV grids.
Źródło:
Inżynieria Mineralna; 2023, 2; 71--78
1640-4920
Pojawia się w:
Inżynieria Mineralna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Mathematical model of the permanent magnet field in the air gap of electrical machine
Matematyczny model pola magnesu trwałego w szczelinie powietrznej maszyny elektrycznej
Autorzy:
Afanasyev, A.
Nikolaev, A.
Powiązania:
https://bibliotekanauki.pl/articles/159653.pdf
Data publikacji:
2014
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Elektrotechniki
Tematy:
Electrical machines
magnetic field
permanent magnets
maszyny elektryczne
pole magnetyczne
magnesy trwałe
Opis:
The paper deals with an analytical model of the magnetic field in the air gap of electrical machine with permanent magnets. In this model, the source of radial and tangential magnet fields can be assumed as a system of equivalent current-carrying buses, which thickness depends on permanent magnet properties. Appropriate formulas that describe the problem in question have been derived.
W artykule zaproponowano oryginalny analityczny model pola magnetycznego w szczelinie powietrznej maszyny elektrycznej z magnesami trwałymi. W modelu tym źródłami składowych: radialnej i tangensjalnej pola magnetycznego są ekwiwalentne układy przewodów z prądem, których grubość zależy od własności materiałowych magnesu trwałego. Wyprowadzono wzory i zależności matematyczne opisujące rozważany model pola.
Źródło:
Prace Instytutu Elektrotechniki; 2014, 267; 21-33
0032-6216
Pojawia się w:
Prace Instytutu Elektrotechniki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Rapid design and development of control applications for electrical engineering
Szybkie tworzenie aplikacji kontrolno-pomiarowych na potrzeby elektrotechniki
Autorzy:
Wojnicki, I.
Rad, M.
Powiązania:
https://bibliotekanauki.pl/articles/282188.pdf
Data publikacji:
2013
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
programming
control systems
software design
electric machines
programowanie
systemy sterowania
projektowanie oprogramowania
maszyny elektryczne
Opis:
This paper presents a control application programming concept based on attributive logic and context-based reasoning. General features and benefits, comparied with other contemporary approaches, are given. The proposed solution is targeted at electric machine tests and diagnostics. An illustrative example of programming an induction motor no-load test which compares the proposed solution with a Matlab-based application is also given.
Artykuł prezentuje koncepcję programowania aplikacji kontrolno-pomiarowych opartą na logice atrybutowej i wnioskowaniu kontekstowym. Przedstawione są ogólne zasady proponowanego podejścia i osiągane korzyści w stosunku do używanych obecnie metod. Przykładem, na którym omówiono sposób tego rodzaju programowania są aplikacje kontrolno-pomiarowe tworzone z myślą o próbach i diagnostyce maszyn elektrycznych. Zamieszczono przykład zaimplementowanej procedury pomiarowej: próby biegu jałowego maszyny indukcyjnej.
Źródło:
Automatyka / Automatics; 2013, 17, 2; 263-270
1429-3447
2353-0952
Pojawia się w:
Automatyka / Automatics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modeling of the electric field grading at conductor-dielectric interfaces under fast rise time pulses
Modelowanie rozkładu pola elektrycznego na powierzchniach granicznych metal-dielektryk przy wymuszeniach impulsowych
Autorzy:
Adamczyk, B.
Florkowka, B.
Powiązania:
https://bibliotekanauki.pl/articles/268110.pdf
Data publikacji:
2013
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
electric field grading
modeling
electric machines
układ izolacyjny
rozkład pola elektrycznego
modelowanie
maszyny elektryczne
Opis:
The insulation systems are subjected to different exploitation stresses. There are electrical stresses due to the time dependence and spatial distribution of the electric field. A differentiation has to be made between sinusoidal (power network) and pulsed stresses. In spite of the overvoltages (lightning and switching) they are also a result of power converters. The power converters technology leads to different and higher electrical stresses in machine windings insulation and cable terminations. Then the interfaces in insulation systems generally consist of combination of conducting, semiconducting and insulation materials adjacent to each other. A criterion for the electrical stresses in insulation systems are partial discharges which occur at these interfaces. The effectiveness of stress-grading systems under fast rise time pulses is discussed in the article. Simulations using Finite Element Method are presented.
Narażenia eksploatacyjne urządzeń elektrycznych są przyczyną degradacji ich układów izolacyjnych, przy czym intensywność i dynamika tych procesów zależą od poziomu natężenia pola elektrycznego, jego przebiegu czasowego i częstotliwości. W grupie narażeń szybkozmiennych szczególne znaczenie mają przepięcia impulsowe, oddziaływujące na układy izolacyjne maszyn elektrycznych, gdy stosowane jest sterowanie z modulacją szerokości impulsów zasilania. Narażenia napięciowe w układach przekształtnikowych stanowią ciągi szybkich impulsów przełączających, formułujących powtarzalne sekwencje, charakteryzujące się modulowaną szerokością i krótkimi czasami narastania i opadania zboczy. Takie warunki mają zasadnicze znaczenie dla powstawania i rozwoju wyładowań niezupełnych w układach izolacyjnych maszyn elektrycznych i kabli elektroenergetycznych. Problem ten dotyczy między innymi elementów układów izolacyjnych tworzących tzw. punkt potrójny (ang. tripple point), a więc wyprowadzeń uzwojeń ze stojana maszyn elektrycznych oraz głowic kablowych, w których natężenie pola elektrycznego może osiągać wartości przekraczające natężenie początkowe wyładowań niezupełnych. Stosowane jest wówczas sterowanie pola elektrycznego przez zastosowanie kombinacji materiałów przewodzących, półprzewodzących i izolacyjnych. Kryterium projektowania tego typu układów izolacyjnych jest między innymi wartość natężenia pola elektrycznego.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2013, 36; 13-16
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Partial discharge test with surge voltage in electric motors windings
Pomiar wyładowań niezupełnych podczas testu surge w uzwojeniach silników elektrycznych
Autorzy:
Ciążyński, M.
Powiązania:
https://bibliotekanauki.pl/articles/1367800.pdf
Data publikacji:
2015
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
electrical machines
partial discharge
surge voltage test
maszyny elektryczne
wyładowania niezupełne
test napięciem skokowym
Opis:
W artykule w prosty sposób przedstawiono typowe uszkodzenia izolacji w maszynach elektrycznych oraz sposoby ich wykrywania. Jako jedną z wielu metod badań diagnostycznych wybrano test surge oraz detekcję wyładowań niezupełnych. Autorzy w przystępny sposób opisują mechanizm powstawania wyładowań niezupełnych.
A typical damages of insulation in electrical machines and methods for their detection are shown in the article in a simple way. As one of many diagnostic methods surge test and partial discharge detection are selected. The author describes in the simple way the mechanism of the partial discharge formation.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2015, 2, 106; 253-255
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modelling and analysis of a synchronous generator in more electric aircraft power system using Synopsys/Saber simulator
Modelowanie i analiza generatora synchronicznego w systemie elektroenergetycznym nowoczesnego samolotu. Zastosowanie symulatora Synopsys/Saber
Autorzy:
Michna, M.
Kutt, F.
Chrzan, P.
Ronkowski, M.
Powiązania:
https://bibliotekanauki.pl/articles/159291.pdf
Data publikacji:
2009
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Elektrotechniki
Tematy:
maszyny elektryczne
modelowanie maszyn elektrycznych
generator synchroniczny
electric machines analysis
electric machines modelling
synchronous generator
Opis:
A model for studying synchronous machine (SM) dynamic behaviour in more electric aircraft (MEA) power system is developed and implemented in the Synopys/Saber simulation environment. The modelling language MAST has been used to elaborate the SM model. The elaborated model exhibit a network with the same number of external terminals/ports as the real SM, and represents its behaviour in terms of the electrical (stator and rotor windings) and mechanical (shaft) variables as well. The main advantage of the approach is the ease of describing MEA power system in terms of its topology. Thus, normal and fault operation of any MEA power system can be effectively investigated. The proposed model was applied to study the short-circuit transients of a synchronous generator. The simulation results have proved that the proposed approach can be recommended for analysis of MEA power systems.
W artykule przedstawiono model do badania stanów dynamicznych generatora synchronicznego (GS) w systemie elektroenergetycznym nowoczesnego samolotu (ang. more electric aircraft). Opracowany model GS implementowano do symulatora Synopsys/Saber. Wykorzystano język modelowania MAST tego symulatora do zapisu równań modelu GS. Opracowany model reprezentuje sieć o tej samej liczbie zacisków/bram zewnętrznych co rzeczywisty GS i jednocześnie opisuje zachowanie GS w funkcji wielkości elektrycznych (uzwojeń stajana i wirnika) oraz mechanicznych (wału). Zasadniczą zaletą takiego podejścia jest łatwy sposób opisania systemu elektroenergetycznym nowoczesnego samolotu w oparciu o jego topologię. Stąd badania pracy systemu w stanach normalnych i awaryjnych są bardziej efektywne. Opracowany model zastosowano do badania procesu zwarcia udarowego GS. Przedstawione wyniki symulacji wskazują, że proponowane podejście do modelowania można rekomendować od analizy systemu elektroenergetycznego nowoczesnego samolotu.
Źródło:
Prace Instytutu Elektrotechniki; 2009, 240; 31-46
0032-6216
Pojawia się w:
Prace Instytutu Elektrotechniki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Examination the robustness of slip-ring induction motor drive controlled by DTC-SVM method
Autorzy:
Smoleń, A.
Mazur, D.
Powiązania:
https://bibliotekanauki.pl/articles/1199273.pdf
Data publikacji:
2017
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
maszyny elektryczne
izolacja zwojowa
badania diagnostyczne prądem stałym
electrical machines
winding insulation
DC diagnostic tests
Opis:
The robustness of DTC-SVM control method applied to a maintain a speed reference value of induction machine has been analysed in this paper. The simulation study were performed based on ideal constant mathematical model of electrical drive implemented in Matlab. The linearized models of torque and flux control loops has been presented and examined in terms of frequency response. The performance of control method was tested in case of significant load torque variations and short-lived inverter supply voltage distortion. The obtained results showed that analysed control system reveals very good dynamic properties in case of load torque changes. Further studies have shown that DTC method is much more susceptible for a supply voltage distortions.
W artykule przedstawiono wyniki testów symulacyjnych układu sterowania maszyny indukcyjnej, wykorzystującego metodę DTC-SVM, pracującego w trybie utrzymywania zadanej wartości prędkości obrotowej. Symulację przeprowadzono w systemie Matlab z wykorzystaniem modelu matematycznego o stałych współczynnikach. Efektywność badanej metody regulacji została przetestowana w przypadku znacznych wahań momentu obciążenia oraz krótkotrwałych zapadów napięcia zasilania falownika. Uzyskane wyniki pokazują że badana metoda zapewnia bardzo dobrą dynamikę regulacji w przypadku zmian momentu obciążenia oraz jej znacznie większą wrażliwość w przypadku zaburzeń napięcia zasilania.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2017, 3, 115; 45-50
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Representation of permanent magnets in the 3-D finite element description of electrical machines
Odwzorowanie magnesów trwałych w dyskretnych trójwymiarowych modelach maszyn elektrycznych
Autorzy:
Demenko, A.
Stachowiak, D.
Powiązania:
https://bibliotekanauki.pl/articles/159929.pdf
Data publikacji:
2006
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Elektrotechniki
Tematy:
magnes trwały
metoda reprezentacyjna
odwzorowanie
maszyny elektryczne
metoda elementów skończonych
permanent magnets
representation method
finite element method
FEM
Opis:
Finite element methods for 3-D magnetic field calculation in permanent magnet motors are discussed. An edge element method using a magnetic vector potential and the nodal element method using a scalar magnetic potential are considered. For both formulations the methods of field source description are presented. Attention is paid to sources in the permanent magnet regions. The methods have been successfully applied in the analysis of motors with inhomogeneously magnetized permanent magnets.
W pracy przedstawiono metody formułowania wektora wymuszeń dla obszarów z magnesami trwałymi. Rozpatrzono dwie metody opisu pola magnetycznego: metodę potencjału skalarnego oraz potencjału wektorowego. Do rozwiązywania równań pola zastosowano metodę elementów skończonych (MES). Rozpatrzono nowe ujęcie MES, w którym wielkości wektorowe opisuje się za pomocą funkcji interpolacyjnych elementów krawędziowych i funkcji interpolacyjnych elementów ściankowych. W metodzie skalarnego potencjału magnetycznego wykorzystuje się funkcje interpolacyjne elementu krawędziowego i wielkości krawędziowe. Wielkościami krawędziowymi są napięcia magnetyczne. Poszukiwane wartości krawędziowe wyraża się za pomocą wartości węzłowych potencjału skalarnego i rozwiązuje się równania opisujące wartości węzłowe. W metodzie potencjału wektorowego wykorzystuje się funkcje interpolacyjne elementu ściankowego i wielkości ściankowe. Wielkościami ściankowymi są strumienie przenikające przez ścianki elementów. Posłużywszy się językiem teorii obwodów strumienie przenikające przez ścianki można nazwać strumieniami gałęziowymi. W algorytmach obliczeniowych strumienie gałęziowe wyraża się za pomocą strumieni oczkowych. Reprezentantami tych strumieni są wielkości krawędziowe wektorowego potencjału magnetycznego A tj. zorientowane całki liniowe z A wzdłuż krawędzi elementów. W pracy przedstawiono metody opisu źródeł od prądów magnetyzacji w przestrzeni elementów krawędziowych i ściankowych. Przyjęto, że w obrębie magnesu wektor H natężenia pola opisany jest wyrażeniem: H = v(w)B - Hm przy czym v(w) jest tensorem reluktywności "wewnętrznej" magnesu, a Hm zastępczym natężeniem powściągającym reprezentowanym przez wektor namagnesowania Tm, Tm = Hm. Przy zapisywaniu powyższej relacji przyjęto, że dotyczy ona lokalnego układu współrzędnych, w którym wektor Hm ma tylko jedną składową w kierunku namagnesowania. W obszarze z magnesami trwałymi źródłami pola są prądy magnetyzacji o gęstości Jm. Przy opisie źródeł w przestrzeni elementów krawędziowych i ściankowych posługiwano się krawędziowymi wartościami wektora magnesowania Tm, uwzględniano, że Jm = rot Tm. Krawędziowe wartości wektora Tm odpowiadają oczkowym prądom magnetyzacji iom w oczkach wokół krawędzi elementów. Na podstawie tych prądów można wyznaczyć iniekcje strumieni źródłowych w metodzie potencjału skalarnego oraz wymuszenia reprezentujące oczkowe siły magnetomotoryczne w metodzie potencjału wektorowego. Przedstawiono przykład zastosowania opracowanych metod. Analizowano moment zaczepowy w maszynie o magnesach złożonych z segmentów niejednorodnie namagnesowanych.
Źródło:
Prace Instytutu Elektrotechniki; 2006, 229; 161-173
0032-6216
Pojawia się w:
Prace Instytutu Elektrotechniki
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies