Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "lifetime" wg kryterium: Temat


Tytuł:
Improvement of enzyme stability via non-covalent complex formation with dextran against temperature and storage lifetime
Autorzy:
Altikatoglu, M.
Kuzu, H.
Powiązania:
https://bibliotekanauki.pl/articles/778394.pdf
Data publikacji:
2010
Wydawca:
Zachodniopomorski Uniwersytet Technologiczny w Szczecinie. Wydawnictwo Uczelniane ZUT w Szczecinie
Tematy:
stabilizacja termiczna
enzymy
dekstran
thermal stabilization
complex
enzyme
dextran
storage lifetime
Opis:
The optimal methodology to prepare the novel modified enzyme, polymer-enzyme complex, was developed to give a high catalytic activity in aqueous solution. The non-covalent complexes of two different enzymes (horseradish peroxidase and glucose oxidase) were prepared with various molar ratios (nD/nE 0,05; 0,1; 1; 5; 10; 15; 20) by using 75kDa dextran. The thermal stabilities of the obtained complexes were evaluated with the activities determined at different temperatures (25, 30, 35, 40, 50, 60, 70, 80°C) applying 60 minutes incubation time for pH 7. The complexes with the molar ratio nD/nHRP: 10 and nD/nGOD: 5 showed the highest thermal stability. Its activity was very high (ca. 1,5-fold higher activity than pure enzyme for HRP-dextran complexes) and almost the same between applying one hour incubation time and without incubation, and could also be measured at high temperatures (70, 80 °C). We finally succeeded in preparing dextran-enzyme complexes which showed higher activity than pure enzyme in aqueos solution at all temperatures for pH 7. In addition, the mentioned complexes at pH 7 had very long storage lifetime compared to purified enzyme at +4 °C; which is considered as a good feature for the usage in practice.
Źródło:
Polish Journal of Chemical Technology; 2010, 12, 1; 12-16
1509-8117
1899-4741
Pojawia się w:
Polish Journal of Chemical Technology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A method for estimating the probability distribution of the lifetime for new technical equipment based on expert judgement
Autorzy:
Andrzejczak, Karol
Bukowski, Lech
Powiązania:
https://bibliotekanauki.pl/articles/2038033.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Polskie Naukowo-Techniczne Towarzystwo Eksploatacyjne PAN
Tematy:
uncertainty
expert elicitation of lifetime
quantile function
Weibull distribution
Opis:
Managing the exploitation of technical equipment under conditions of uncertainty requires the use of probabilistic prediction models in the form of probability distributions of the lifetime of these objects. The parameters of these distributions are estimated with the use of statistical methods based on historical data about actual realizations of the lifetime of examined objects. However, when completely new solutions are introduced into service, such data are not available and the only possible method for the initial assessment of the expected lifetime of technical objects is expert methods. The aim of the study is to present a method for estimating the probability distribution of the lifetime for new technical facilities based on expert assessments of three parameters characterizing the expected lifetime of these objects. The method is based on a subjective Bayesian approach to the problem of randomness and integrated with models of classical probability theory. Due to its wide application in the field of maintenance of machinery and technical equipment, a Weibull model is proposed, and its possible practical applications are shown. A new method of expert elicitation of probabilities for any continuous random variable is developed. A general procedure for the application of this method is proposed and the individual steps of its implementation are discussed, as well as the mathematical models necessary for the estimation of the parameters of the probability distribution are presented. A practical example of the application of the developed method on specific numerical values is also presented.
Źródło:
Eksploatacja i Niezawodność; 2021, 23, 4; 757-769
1507-2711
Pojawia się w:
Eksploatacja i Niezawodność
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Advanced lifetime assessment of steam turbine components based on long-term operating data
Autorzy:
Banaszkiewicz, M.
Radulski, W.
Dominiczak, K.
Powiązania:
https://bibliotekanauki.pl/articles/139746.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
steam turbine
lifetime assessment
creep
low cycle fatigue
turbina parowa
szacowanie cyklu życia
pełzanie
zmęczenie niskocyklowe
Opis:
The paper presents a new method of lifetime calculations of steam turbine components operating at high temperatures. Component life is assessed on the basis of creep-fatigue damage calculated using long-term operating data covering the whole operating period instead of representative events only. The data are analysed automatically by a dedicated computer program developed to handle big amount of process data. Lifetime calculations are based on temperature and stress analyses performed by means of finite element method and using automatically generated input files with thermal and mechanical boundary conditions. The advanced lifetime assessment method is illustrated by an example of lifetime calculations of a steam turbine rotor.
Źródło:
Archive of Mechanical Engineering; 2018, LXV, 4; 579-597
0004-0738
Pojawia się w:
Archive of Mechanical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Numerical investigation of creep behaviour of high-temperature steam turbine compone
Autorzy:
Banaszkiewicz, M.
Powiązania:
https://bibliotekanauki.pl/articles/175375.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
creep
lifetime assessment
steam turbine
Opis:
The paper presents a model for creep basing on the so-called characteristic creep strain. It illustrates its application in computations of old steam turbines components. The presented model is a modification of the Norton model which relates the stress exponent to the creep rupture strength and current stress. Creep strain is a function of the above two quantities, i.e., rupture strength and current stress, and acharacteristic creep strain which is material constant for a given time and temperature. Computational examples regard the rotating and pressure components analysed using the finite element method.
Źródło:
Transactions of the Institute of Fluid-Flow Machinery; 2012, 124; 5-15
0079-3205
Pojawia się w:
Transactions of the Institute of Fluid-Flow Machinery
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Concept of advanced lifetime monitoring system for steam turbines
Koncepcja zaawansowanego systemu monitorowania żywotności turbin parowych
Autorzy:
Banaszkiewicz, Mariusz
Powiązania:
https://bibliotekanauki.pl/articles/1840894.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Polskie Towarzystwo Diagnostyki Technicznej PAN
Tematy:
monitoring
steam turbines
lifetime assessment
low-cycle fatigue
creep
monitorowanie
turbina parowa
ocena żywotności
zmęczenie małocyklowe
pełzanie
Opis:
The increasing share of renewables in electricity production adversly affects the operation of thermal plants, including steam turbine units. Intermittency of renewable sources results in high variability of steam turbine operating conditions, which together with the inherent scatter of turbine operating parameters significantly complicates their lifetime assessment. The paper presents a concept of lifetime monitoring system in scope of creep-fatigue damage. The system is based on online and offline calculations, performs online analysis of measurement data and takes into account the results of material tests. Functionality of the system main modules is described and mathematical models suitable for online calculations are presented. A general concept of hardware configuration for the system is proposed as well.
Wzrastający udział odnawialnych źródeł energii w produkcji prądu ma niekorzystny wpływ na pracę elektrowni cieplnych, w tym bloków parowych. Niestabilność źródeł odnawialnych skutkuje dużą zmiennością warunków pracy turbin parowych, co w połączeniu z nieodłącznym rozrzutem parametrów pracy turbin w znaczący sposób komplikuje ocenę ich żywotności. W artykule przedstawiono koncepcję systemu monitorowania żywotności w zakresie zużycia zmęczeniowo-pełzaniowego. System ten oparty jest na obliczeniach w trybie online i offline, wykonuje na bieżąco analizę danych pomiarowych oraz uwzględnia wyniki badań materiałowych. Omówione zostały funkcje głównych modułów systemu wraz z propozycją modeli matematycznych odpowiednich do obliczeń w trybie online. Zaproponowano również ogólną koncepcję konfiguracji sprzętowej systemu.
Źródło:
Diagnostyka; 2021, 22, 1; 23-29
1641-6414
2449-5220
Pojawia się w:
Diagnostyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Maximization of Safety Lifetime of Critical Infrastructure Network with Cascading Effects Considering Climate-Weather Change Influence
Autorzy:
Blokus-Roszkowska, A.
Kołowrocki, K.
Powiązania:
https://bibliotekanauki.pl/articles/2068749.pdf
Data publikacji:
2018
Wydawca:
Uniwersytet Morski w Gdyni. Polskie Towarzystwo Bezpieczeństwa i Niezawodności
Tematy:
critical infrastructure
operation process
climate-weather change process
critical state
critical infrastructure safety lifetime maximization
Opis:
In the paper optimization of operation process and maximization of safety lifetimes for interconnected and interdependent critical infrastructure (CI) networks at variable operation conditions related to the climateweather change are proposed. A multistate series network with assets dependent according to local load sharing (LLS) rule is analyzed and optimization of operation and safety of CI network with the LLS rule is introduced. For such CI network, the optimal transient probabilities of CI network operation process at operation states related to climate-weather change that maximize the mean value of CI network safety lifetimes are found. Finally, the optimal safety and resilience indicators of CI network are presented.
Źródło:
Journal of Polish Safety and Reliability Association; 2018, 9, 1; 35--42
2084-5316
Pojawia się w:
Journal of Polish Safety and Reliability Association
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Fatigue lifetime of 20MnV6 steel with holes manufactured by various methods
Autorzy:
Bokůvka, O.
Jambor, M.
Trško, L.
Nový, F.
Lisiecka, B.
Powiązania:
https://bibliotekanauki.pl/articles/111905.pdf
Data publikacji:
2018
Wydawca:
Stowarzyszenie Menedżerów Jakości i Produkcji
Tematy:
steel 20MnV6
fatigue lifetime
high-cycle fatigue
stal 20MnV6
trwaość zmęczeniowa
zmęczenie wysokocyklowe
Opis:
In this paper, the authors publish their own experimental results of the examination of the different holes (milled, drilled and drilled + shot peened) on the fatigue lifetime of 20MnV6 steel. The experiments were carried out at low-frequency loading (f = 10 Hz, pulsating tension loading) in the region from N = 2×105 up to N = 2×106 cycles. The best fatigue properties were obtained in the parts with drilled + shot peened holes.
Źródło:
Production Engineering Archives; 2018, 19; 3-5
2353-5156
2353-7779
Pojawia się w:
Production Engineering Archives
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
On a general standby system and its optimization
Autorzy:
Cha, J. H.
Yun, W. Y.
Powiązania:
https://bibliotekanauki.pl/articles/2069693.pdf
Data publikacji:
2009
Wydawca:
Uniwersytet Morski w Gdyni. Polskie Towarzystwo Bezpieczeństwa i Niezawodności
Tematy:
warm standby
accelerated life testing
virtual age
switching time
mean lifetime
Opis:
Redundancy or standby is a technique that has been widely applied to improving system reliability and availability in the stage of system design. In this paper, we consider a standby system with two units in which the first unit (unit 1) starts its operation under active state and the other unit (unit 2) is under cold standby state at the starting point. After a specified time s (switching time), the state of unit 2 is changed to warm standby state and, as soon as the operating unit 1 fails, the state of unit 2 is changed to active state. If unit 1 fails before times, the system fails. Units can fail at both active and warm standby states. A general method for modeling the standby system is adopted and, based on it, system performance measures (system reliability and mean life) are derived. We consider the problem of determining optimal switching time which maximizes the expected system life. Some numerical examples are studied.
Źródło:
Journal of Polish Safety and Reliability Association; 2009, 1; 95--100
2084-5316
Pojawia się w:
Journal of Polish Safety and Reliability Association
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
An Innovative Multiple Attribute Based Distributed Clustering with Sleep/Wake Scheduling Mechanism for WSN
Autorzy:
Chavan, Shankar D.
Jagdale, Shahaji R.
Kulkarni, Dhanashree A.
Jadhav, Sneha R.
Powiązania:
https://bibliotekanauki.pl/articles/1844582.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
advanced distributed
energy efficient
adaptive clustering
clustering
lifetime
sleep-wake cluster head scheduling
throughput
wireless sensor network
Opis:
Wireless sensor network is a dynamic field of networking and communication because of its increasing demand in critical Industrial and Robotics applications. Clustering is the technique mainly used in the WSN to deal with large load density for efficient energy conservation. Formation of number of duplicate clusters in the clustering algorithm decreases the throughput and network lifetime of WSN. To deal with this problem, advance distributive energy-efficient adaptive clustering protocol with sleep/wake scheduling algorithm (DEACP-S/W) for the selection of optimal cluster head is presented in this paper. The presented sleep/wake cluster head scheduling along with distributive adaptive clustering protocol helps in reducing the transmission delay by properly balancing of load among nodes. The performance of algorithm is evaluated on the basis of network lifetime, throughput, average residual energy, packet delivered to the base station (BS) and CH of nodes. The results are compared with standard LEACH and DEACP protocols and it is observed that the proposed protocol performs better than existing algorithms. Throughput is improved by 8.1% over LEACH and by 2.7% over DEACP. Average residual energy is increased by 6.4% over LEACH and by 4% over DEACP. Also, the network is operable for nearly 33% more rounds compared to these reference algorithms which ultimately results in increasing lifetime of the Wireless Sensor Network.
Źródło:
International Journal of Electronics and Telecommunications; 2021, 67, 3; 437-443
2300-1933
Pojawia się w:
International Journal of Electronics and Telecommunications
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Lifetime performance evaluation model based on quick response thinking
Autorzy:
Chiou, Kuo-Ching
Chen, Kuen-Suan
Powiązania:
https://bibliotekanauki.pl/articles/2057979.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Polskie Naukowo-Techniczne Towarzystwo Eksploatacyjne PAN
Tematy:
lifetime performance index
Type-II right censoring
UMVU estimators
UMP test
Opis:
In practice, lifetime performance index CL has been a method commonly applied to the evaluation of quality performance. L is the upper or lower limit of the specification. The product lifetime distribution is mostly abnormal distribution. This study explored that the lifetime of commodities comes from exponential distribution. Complete data collection is the primary goal of analysis. However, the censoring type is one of the most commonly used methods due to considerations of manpower and material cost or the timeliness of product launch. This study adopted Type-II right censoring to find out the uniformly minimum variance unbiased (UMVU) estimator of the lifetime performance index CL and its probability density function. Afterward this study obtained the 100×(1-α)% confidence interval of the lifetime performance index CL as well as created the uniformly most powerful (UMP) test and the power of the test for the product lifetime performance index. Last, this study came up with a numerical example to demonstrate the suggested method as well as the application of the model.
Źródło:
Eksploatacja i Niezawodność; 2022, 24, 1; 1--6
1507-2711
Pojawia się w:
Eksploatacja i Niezawodność
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
TiO2 modified by ammonia as a long lifetime photocatalyst for dyes decomposition
Autorzy:
Choina, J.
Dolat, D.
Kusiak, E.
Janus, M.
Morawski, A.W.
Powiązania:
https://bibliotekanauki.pl/articles/778832.pdf
Data publikacji:
2009
Wydawca:
Zachodniopomorski Uniwersytet Technologiczny w Szczecinie. Wydawnictwo Uczelniane ZUT w Szczecinie
Tematy:
fotokataliza
TiO2 modyfikowany azotem
żywotność
photocatalysis
nitrogen-modified TiO2
lifetime
Opis:
Ammonia-modified TiO2 (TiO2/N), prepared in a pressure reactor was used as the well- active and longlife photocatalyst for the azo dye (Reactive Red 198) decomposition. The effect of aeration and the different value of the pH of the reaction medium on the photocatalytic degradation of Reactive Red 198 in water has been investigated. It has been reported that the degradation is greatly influenced by the reaction pH and the faster decomposition of azo dye took place at pH 3.5. When the solution was acidic, a larger amount of azo dye on the positively charged surface of TiO2 photocatalysts was adsorbed. From the obtained results it can be seen that the effectiveness of the decolourisation of the solution was faster by using the nitrogen-modified TiO2.
Źródło:
Polish Journal of Chemical Technology; 2009, 11, 4; 1-6
1509-8117
1899-4741
Pojawia się w:
Polish Journal of Chemical Technology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Gas turbine reliability model based on tangent hyperbolic reliability function
Autorzy:
Djeddi, A. Z.
Hafaifa, A.
Salam, A.
Powiązania:
https://bibliotekanauki.pl/articles/280120.pdf
Data publikacji:
2015
Wydawca:
Polskie Towarzystwo Mechaniki Teoretycznej i Stosowanej
Tematy:
reliability estimation
reliability algorithms
lifetime distribution
Weibull distribution
availability
Opis:
The present work deals with the exploration of a new model proposed for the reliability analysis of industrial production systems. This proposed model is mainly based on the tangent hyperbolic function, where the survival function is determined and used in the lifetime distribution modeling taking into account of estimation the parameters of the proposed function. On the other side, tests validation is performed using the real data of a gas turbine installation. The obtained results allow the modeling of damage effects, hence the prediction of the performance of the examined gas turbine using the proposed model gives good results in terms of validity.
Źródło:
Journal of Theoretical and Applied Mechanics; 2015, 53, 3; 723-730
1429-2955
Pojawia się w:
Journal of Theoretical and Applied Mechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Record-based inference and associated cost analysis for the Weibull distribution
Autorzy:
Doostparast, M.
Powiązania:
https://bibliotekanauki.pl/articles/205931.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Instytut Badań Systemowych PAN
Tematy:
cost analysis
likelihood function
record data
total time on test
Weibull model
lifetime model
Opis:
In statistical process control, record schemes are used to reduce the total time on test for the inspection inquiry. In these schemes, units are examined sequentially and successive minimum values are recorded. On the basis of record data, Samaniego and Whitaker (1986) obtained the maximum likelihood (ML) estimate of the mean for an exponential distribution. Since the two parameter Weibull model, as an extension of the exponential distribution, has a wide range of application, Hoinkes and Padgett (1994) derived the record-based ML estimators for the parameters of interest in this model. This paper shows that the ML estimates of the Weibull parameters do not always exist for the basis of records. Thus, a new scheme is proposed, in which the ML estimates of the parameters always exist. An analytic cost-based comparison between the usual and the New scheme is also carried out. Finally, some concluding remarks and open problems are formulated.
Źródło:
Control and Cybernetics; 2015, 44, 1; 163-177
0324-8569
Pojawia się w:
Control and Cybernetics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Diagnostics of control rod drive. Possibilities to extend its lifetime at NPPs
Diagnostyka napędu pręta sterującego. Możliwości zwiększenia czasu eksploatacji napędów w elektrowniach atomowych
Autorzy:
Druzhinin, I.
Sapozhnikova, K.
Taymanov, R.
Powiązania:
https://bibliotekanauki.pl/articles/329298.pdf
Data publikacji:
2008
Wydawca:
Polska Akademia Nauk. Polskie Towarzystwo Diagnostyki Technicznej PAN
Tematy:
elektromagnetyczny liniowy silnik krokowy
czujnik położenia
pręt sterujący
czas eksploatacji
reaktor jądrowy
linear stepping electromagnetic drive
control rod position sensor
lifetime
nuclear reactor
Opis:
According to specifications, lifetime of a linear stepping electromagnetic drive in WWER-1000 nuclear reactors is limited by the pre-assigned lifetimes of the drive components such as electromagnets, a latch assembly, drive rack, and control rod position sensor. The lifetime of the drive components is from 7 to 20 years. On the basis of diagnostics of these components under real conditions, actual lifetimes of the components at nuclear power plant (NPP) were forecasted. It is shown that in order to extend the lifetime of the drive components up to the reactor lifetime (60 years), it is necessary to replace the sensor of the DPL-type by the new one (of the DPL-KV type) and to decrease the electromagnet temperature. The Measuring and Diagnostic System with the DPL-KV sensor enables diagnosing the sensor, electronic processing unit and drive. Economic effect due to the cumulative technical decisions is estimated to be 7 mln.euro per NPP unit.
Zgodnie z dokumentacją czas eksploatacji elektromagnetycznych silników krokowych prętów sterujących w reaktorach jądrowych WWER-1000 jest ograniczony ustalonymi czasami eksploatacji ich składników (blok przesunięcia, pręt, elektromagnesy, czujnik) - od 7 do 20 lat. Na podstawie wyników diagnostyki tych składników w warunkach realnych została zrobiona prognoza ich rzeczywistej żywotności w elektrowniach atomowych. Wykazano, że w celu wydłużenia czasu eksploatacji składników do czasu życia reaktora (60 lat) trzeba wymienić czujnik DPL na inny, bardziej niezawodny - DPL-KV i znacznie obniżyć temperaturę elektromagnesów. Układ pomiarowo-diagnostyczny wyposażony w czujnik DPL-KV pozwala przeprowadzać diagnostykę czujnika, osprzętu elektronicznego i silnika. Całkowity efekt ekonomiczny wprowadzenia zaproponowanych rozwiązań technicznych jest szacowany na 7 milionów Euro na blok energetyczny.
Źródło:
Diagnostyka; 2008, 3(47); 89-93
1641-6414
2449-5220
Pojawia się w:
Diagnostyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Implementation of mathematical model of thermal behavior of electronic components for lifetime estimation based on multi-level simulation
Autorzy:
Frivaldsky, M.
Pridala, M.
Drgona, P.
Powiązania:
https://bibliotekanauki.pl/articles/140808.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
electrolytic capacitor
lifetime model
lifetime estimation
system-level simulation
Opis:
The main purpose of the paper is the proposal of multi-level simulation, suited for the evaluation of the lifetime of critical electronic devices (electrolytic capacitors). The aim of this issue is to imagine about the expected operation of complex and expensive power electronic systems, when the failure of the most critical component occurs. For that reason, various operational conditions and various physical influences must be considered (e.g. mechanical, humidity, electrical, heat stress), where nonlinearities are naturally introduced. Verification of the proposal is given, whereby the life-time estimation of an electrolytic capacitor operated in a DC-DC converter during various operational conditions is shown. At this point electrical and heat stress is considered for lifetime influence. First, the current state in the field of mathematical modeling of the lifetime for electrolytic capacitors, considering main phenomena is introduced. Next, individual sub-models for multi-level simulation purposes are developed, including a thermal simulation model and electrical simulation model. Several complexities of individual models are mutually compared in order to evaluate their accuracy and suitability for further use. Proper simulation tools have been mutually linked and data transfer was secured, in order to have the possibility of investigation of a lifetime depend on the changes of various variables.
Źródło:
Archives of Electrical Engineering; 2017, 66, 2; 339-350
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies