Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "instrument transformers" wg kryterium: Temat


Wyświetlanie 1-3 z 3
Tytuł:
Measuring accuracy of electric energy in HV power networks
Autorzy:
Jałmużny, W.
Powiązania:
https://bibliotekanauki.pl/articles/262655.pdf
Data publikacji:
2005
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie
Tematy:
electric energy measuring
instrument transformers
measuring accuracy
Opis:
The article presents the effect of secondary circuits of inductive current and voltage transformers on measuring accuracy in HV power networks. The basic parameters of instrument transformers were defined, such as errors or rated output. The impedance effect of the leads connecting secondary terminals with measuring instruments and the impact of burden power on the energy measuring error were analyzed. The calculation samples illustrate the procedure when assessing energy (power) measuring error. The algorithm may be applied, with positive results, by the operating personnel of measuring circuits with instrument transformers.
Źródło:
Electrical Power Quality and Utilisation. Journal; 2005, 11, 1; 3-15
1896-4672
Pojawia się w:
Electrical Power Quality and Utilisation. Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Highly accurate calibration system for electronic instrument transformers
Autorzy:
Tong, Y.
Ye, G.
Guo, K.
Li, H.
Powiązania:
https://bibliotekanauki.pl/articles/220441.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
electronic instrument transformers
digital output
calibration system
virtual instrument
Fourthorder Convolution Window
Opis:
A high accurate electronic instrument transformer calibration system is introduced in this paper. The system uses the fourth-order convolution window algorithm for the error calculation method. Compared with Fast Fourier Transform, which is recommended by standard IEC-60044-8 (Electronic current transformers), it has higher accuracy. The relative measuring errors caused by asynchronous sampling could be reduced effectively without any special hardware technique adopted. The results show that the ratio error caused by asynchronous sampling can be reduced to 10-4, and the phase error can be reduced to 10-3 degrees when the deviation of frequency is within š0.5 Hz. The present method of measurement processing is achieved by a high-accuracy USB multifunction data acquisition (DAQ) card and virtual measurement devices, with low cost, short exploitation period and high stability.
Źródło:
Metrology and Measurement Systems; 2011, 18, 2; 315-322
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
An on-site calibration system for electronic instrument transformers based on LabVIEW
Autorzy:
Zhang, M.
Li, K.
Wang, J.
He, S.
Powiązania:
https://bibliotekanauki.pl/articles/221656.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
calibration system
electronic instrument transformers
data acquisition
data synchronization
LabVIEW
Opis:
Electronic voltage transformers (EVT) and electronic current transformers (ECT) are important instruments in a digital substation. For simple, rapid and convenient development, the paper proposed an on-site calibration system for electronic instrument transformers based on LabVIEW. In the system, analog signal sampling precision and dynamic range are guaranteed by the Agilent 3458A digital multimeter, and data synchronization is also achieved based on a self-developed PCI synchronization card. To improve the measurement accuracy, an error correction algorithm based on the Hanning window interpolation FFT has good suppression of frequency fluctuation and inter-harmonics interference. The human-computer interface and analysis algorithm are designed based on LabVIEW, and the adaptive communication technology is designed based on IEC61850 9-1/2. The calibration system can take into account pairs of digital output and analog output of the electronic voltage/current transformer calibration. The results of system tests show that the calibration system can meet the requirements of 0.2 class calibration accuracy, and the actual type test and on-site calibration also show that the system is easy to operate with convenience and satisfactory stability.
Źródło:
Metrology and Measurement Systems; 2014, 21, 2; 257-270
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-3 z 3

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies