Tytuł:
Long lasting transients in power filter circuits
Autorzy:
Warecki, J.
Gajdzica, M.
Powiązania:
https://bibliotekanauki.pl/articles/97714.pdf
Data publikacji:
2014
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
inrush current
arc fumace transformer
harmonic filter
switching transient
Opis:
The practice of operating AC electrical arc fumace power supply systems has shown that energizing unloaded fumace transformer can cause long lasting transients in filter circuits of static VAR compensators used in the supply systems. Examination of the supply system configuration impact on switching transient behaviour has been carried out by example of a 50 MVA arc fumace unit. The transient analysis has been carried out through simulating by Matlab/Simulink software.
Źródło:
Computer Applications in Electrical Engineering; 2014, 12; 324-333
1508-4248
Pojawia się w:
Computer Applications in Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Novel soft-start method for three-phase voltage source rectifier based on virtual resistor control
Autorzy:
He, Kaizhong
Su, Hongsheng
Powiązania:
https://bibliotekanauki.pl/articles/141230.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
equipment safety
inrush current
rectifier
stable operation
virtual resistor
Opis:
The existence of inrush current poses a significant problem during the start-up process within three-phase voltage-source rectifiers. To address this problem, this study proposes a strategy to suppress the inrush current effectively based on the virtual-resistorcontrol method, while preventing the increase in cost of the system and complexity of the algorithm. First, a mathematical model is established based on the dq coordinate frame, and the primary cause of the inrush current is analyzed. Then, the design process of the virtual-resistor-control method is detailed. Finally, the accuracy and effectiveness of the proposed method are verified by simulations and experiments. The results show that the inrush current can be more than two times the rated current before the addition of the virtual resistor. The start-up process can be realized without the inrush current after the addition of the virtual resistor, it does not need to increase hardware costs, there is no secondary inrush current, and the sensitivity of the parameters and the complexity of control are low
Źródło:
Archives of Electrical Engineering; 2020, 69, 1; 215-231
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Extended Feedback Linearisation Control of Non-ideal DCDC Buck Converter in Continuous-conduction Mode
Autorzy:
Csizmadia, Miklos
Kuczmann, Miklos
Powiązania:
https://bibliotekanauki.pl/articles/2175943.pdf
Data publikacji:
2022
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
DC-DC buck converter
feedback linearisation
inrush current
parasitics
Ackermann
Opis:
This paper presents an extended form of Feedback Linearisation Control (FBLC), which is tested in a non-ideal buck converter in Continuous-conduction Mode (CCM). The FBLC is often used in power electronics to control a non-linear system, due to its advantageous properties. The application of the error integrator shows better steady-state and transient properties, such as a decrease of inrush current. The linearised system has been controlled by the pole placement and the technique is illustrated through an example and simulated via Matlab. The results have been compared by using a classical PID controller, allowing the benefits of FBLC to be highlighted.
Źródło:
Power Electronics and Drives; 2022, 7, 42; 1--8
2451-0262
2543-4292
Pojawia się w:
Power Electronics and Drives
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A Study on the Low Frequency Transients in Power Transformers and Some Protection-Related Issues
Autorzy:
Saied, M. M.
Powiązania:
https://bibliotekanauki.pl/articles/1203944.pdf
Data publikacji:
2014
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie
Tematy:
transformer cores
inrush current
protection
transients
modeling
equivalent circuit
low frequency
nonlinear model
simulation
Opis:
This paper presents typical results for the non-linear low frequency transients following the energization of power transformers. The three operating conditions of no-load, full-load and internal faults are considered. A direct analytical procedure is applied for solving the corresponding set of differential equations describing the transformers equivalent circuit. The core representation is based on the use of curve fitting applied to their magnetization curves. The results include plots versus time for the supply current, the core flux, the magnetizing current as well as the internal induced voltage. Moreover, graphs for the hysteresis loops relating the instantaneous values of both the excitation current and the core flux are given. An approach is also presented for the numerical determination of the amplitudes of the different harmonics existing in any of these signals utilizing the corresponding equidistant samples. As examples, the DC offset as well as harmonics up to the fourth order are considered. It is shown that several useful features can be extracted from the results in both the time and harmonic domains that can assist in differentiating between overcurrents resulting from short-circuits or inrush phenomena.
Źródło:
Electrical Power Quality and Utilisation. Journal; 2014, 17, 2; 9-16
1896-4672
Pojawia się w:
Electrical Power Quality and Utilisation. Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-4 z 4

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies