Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "industrial hall" wg kryterium: Temat


Wyświetlanie 1-5 z 5
Tytuł:
Expert opinion on the technical condition of purlins and girders in the roof of a slag storage hall
Ekspertyza stanu technicznego płatwi i dźwigarów dachu hali magazynowania żużla
Autorzy:
Czarniawski, Tadeusz
Powiązania:
https://bibliotekanauki.pl/articles/2175031.pdf
Data publikacji:
2021
Wydawca:
Politechnika Częstochowska
Tematy:
metal structures
Eurocodes
industrial hall
strength calculations
konstrukcje metalowe
Eurokody
hala przemysłowa
obliczenia wytrzymałościowe
Opis:
The intensive development of industrial construction imposes the necessity to apply new technological and construction solutions, taking into account changes in legal regulations. At present we are in a situation where a significant part of buildings and structures was designed and constructed during the validity period of standards and regulations which are currently outdated. This situation forces owners and users of existing facilities to assess them in terms of compliance with currently valid Eurocodes
Intensywny rozwój budownictwa przemysłowego narzuca konieczność stosowania nowych rozwiązań technologicznych i konstrukcyjnych, uwzględniając zmiany zachodzące w przepisach prawa. Obecnie znajdujemy się w sytuacji, gdzie istotna część budynków i budowli została zaprojektowana i wykonana w okresie obowiązywania norm i przepisów, które w chwili obecnej są nieaktualne. Sytuacja taka wymusza na właścicielach i użytkownikach istniejących obiektów ich ocenę pod względem zgodności z obecnie obowiązującymi Eurokodami.
Źródło:
Zeszyty Naukowe Politechniki Częstochowskiej. Budownictwo; 2021, 27 (177); 24-29
0860-7214
Pojawia się w:
Zeszyty Naukowe Politechniki Częstochowskiej. Budownictwo
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Resistance of a steel roof stiffening system of industrial halls made from cold formed profiles
Autorzy:
Wojnar, Andrzej
Sieńkowska, Katarzyna
Chernieva, Olena
Powiązania:
https://bibliotekanauki.pl/articles/105560.pdf
Data publikacji:
2019
Wydawca:
Politechnika Rzeszowska im. Ignacego Łukasiewicza. Oficyna Wydawnicza
Tematy:
metal structures
industrial hall
cold formed elements
stability of cold formed elements
hala przemysłowa
konstrukcja metalowa
stabilność elementów
Opis:
Single-nave halls with a steel structure are used in industrial construction and as storage, sports, public facilities, temporary buildings, etc. In terms of design, they consist of: main load-bearing systems, purlins and support systems for the wall casing and roofing. Individual elements of the hall structure can be made of hotrolled profiles or cold formed, thin-walled elements with slender walls. The load capacity of the roof structure of an industrial hall, unconstrained by roofing, was analysed in the paper. The rigidity of the roof structure in its plane was ensured by an appropriate roof bracing system. It was also assumed that the work of the roof structure in a perpendicular direction to the roof plane is to be similar to the behavior of a steel grate - cooperation between purlins and rigid tie rods was assumed, with vertical loads applied only to the purlins.
Źródło:
Czasopismo Inżynierii Lądowej, Środowiska i Architektury; 2019, 66, 4; 17-28
2300-5130
2300-8903
Pojawia się w:
Czasopismo Inżynierii Lądowej, Środowiska i Architektury
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Resistance of a steel roof stiffening system of industrial halls made from cold formed profiles
Autorzy:
Wojnar, Andrzej
Sieńkowska, Katarzyna
Chernieva, Olena
Powiązania:
https://bibliotekanauki.pl/articles/2065747.pdf
Data publikacji:
2019
Wydawca:
Politechnika Rzeszowska im. Ignacego Łukasiewicza. Oficyna Wydawnicza
Tematy:
metal structures
industrial hall
cold formed elements
stability of cold formed elements
hala przemysłowa
konstrukcja metalowa
stabilność elementów
Opis:
Single-nave halls with a steel structure are used in industrial construction and as storage, sports, public facilities, temporary buildings, etc. In terms of design, they consist of: main load-bearing systems, purlins and support systems for the wall casing and roofing. Individual elements of the hall structure can be made of hotrolled profiles or cold formed, thin-walled elements with slender walls. The load capacity of the roof structure of an industrial hall, unconstrained by roofing, was analysed in the paper. The rigidity of the roof structure in its plane was ensured by an appropriate roof bracing system. It was also assumed that the work of the roof structure in a perpendicular direction to the roof plane is to be similar to the behavior of a steel grate - cooperation between purlins and rigid tie rods was assumed, with vertical loads applied only to the purlins.
Źródło:
Czasopismo Inżynierii Lądowej, Środowiska i Architektury; 2019, 66, 4; 17--28
2300-5130
2300-8903
Pojawia się w:
Czasopismo Inżynierii Lądowej, Środowiska i Architektury
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of steel industrial portal frame building subjected to loads resulting from land surface uplift following the closure of underground mines
Analiza żelbetowej hali magazynowej poddanej obciążeniom pochodzącym od wypiętrzenia powierzchni terenu będących skutkiem likwidacji podziemnych kopalń przez zatapianie
Autorzy:
Dudek, Mateusz
Rusek, Janusz
Tajduś, Krzysztof
Słowik, Leszek
Powiązania:
https://bibliotekanauki.pl/articles/1852377.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
likwidacja kopalni
zatapianie kopalni
wypiętrzenie
modelowanie numeryczne
hala stalowa
hala magazynowa
szkoda górnicza
mine closure
mine flooding
uplift
numerical modelling
industrial hall
portal frame hall
mining damage
Opis:
The liquidation of underground mines by the flooding leads to movements of the rock mass and land surface as a result of pressure changes in the flooded zones. The changes resulting from the rising water table caused by the changes in the stress and strain state, as well as the physical and mechanical properties of rock layers, can lead to damage to building structures and environmental changes, such as chemical pollution of the surface water. For this reason, the ability to predict the movements of rock masses generated as a result of mine closure by flooding serves a key function in relation to the protection of the land surface and buildings present thereon. This paper presents an analysis of a steel industrial portal-frame structure under loading generated by the liquidation of a mine by flooding. The authors obtained land surface uplift results for the liquidated mine and used them in a numerical simulation for the example building. Calculations were performed for different cases, and the results were compared to determine whether limit states may be exceeded. A comparison was made between the cases for the design state and for additional loading caused by the uplift of the subsurface layer of the rock mass.
Likwidacja podziemnych kopalń przez zatapianie prowadzi do ruchów górotworu i powierzchni terenu w wyniku zmian ciśnienia w strefach zatapianych. Zmiany wynikające z podniesienia się zwierciadła wody podziemnej, spowodowane zmianami stanu naprężenia i odkształcenia oraz właściwości fizycznych i mechanicznych warstw skał mogą prowadzić do uszkodzeń powierzchniowych obiektów budowlanych oraz zmian środowiskowych, takich jak chemiczne zanieczyszczenie wód przypowierzchniowych. Z tego względu możliwość przewidywania ruchów górotworu powstających w wyniku likwidacji kopalń przez zatapianie pełni kluczową funkcję w odniesieniu do ochrony powierzchni terenu i znajdujących się na nim budynków. W artykule przedstawiono analizę przemysłowej stalowej hali magazynowej pod obciążeniem wynikającym z likwidacji kopalni w wyniku jej zatapiania. Autorzy uzyskali wyniki wypiętrzenia terenu zlikwidowanej kopalni i wykorzystali je w symulacji numerycznej przykładowego budynku. Obliczenia przeprowadzono dla różnych przypadków, a wyniki porównano w celu określenia, czy możliwe jest przekroczenie stanów granicznych. Dokonano porównania pomiędzy stanem projektowym i dla dodatkowego obciążenia spowodowanego wypiętrzeniem przypowierzchniowej warstwy gruntu.
Źródło:
Archives of Civil Engineering; 2021, 67, 3; 283-298
1230-2945
Pojawia się w:
Archives of Civil Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Determining the dynamic resistance of existing steel industrial hall structures for areas with different seismic activity
Wyznaczanie odporności dynamicznej istniejących hal przemysłowych o konstrukcji stalowej dla obszarów o różnej aktywności sejsmicznej
Autorzy:
Rusek, J.
Słowik, L.
Firek, K.
Pitas, M.
Powiązania:
https://bibliotekanauki.pl/articles/1849754.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
odporność dynamiczna
analiza spectrum odpowiedzi
wstrząs górniczy
konstrukcja stalowa
hala przemysłowa
teren sejsmiczny
dynamic resistance
spectrum response analysis
mining tremor
steel structure
industrial hall
seismic activity area
Opis:
The paper presents the results of research concerning the assessment of dynamic resistance of existing industrial hall structures located in areas with different seismic activity. The basis for analyses was a three-nave industrial hall with a steel structure. Numerical calculations were performed using the finite element method (FEM), using the response spectrum method in dynamic analysis. The calculations were carried out in variants, using standard accelerated response spectra according to Eurocode 8 and those determined for the Upper Silesian Coal Basin (USCB) and Legnica-Glogow Copper District (LGCD) area. Using the author's procedure for the assessment of the dynamic resistance, for each of the extortion analysed, the structure's response to the dynamic excitation was compared with the effects of load combinations adopted at the design stage, thus establishing the limit values of the design horizontal ground acceleration αmaxg,H understood as the structure's resistance to tremors. This allowed to assess the impact of seismic activity from a specific area on the dynamic resistance of the subjected object. The article also discusses the way of interpretation and the scope of application of the obtained results and proposed procedure.
W pracy przedstawiono wyniki badań dotyczących oceny odporności dynamicznej istniejących konstrukcji hal przemysłowych zlokalizowanych na terenach o różnej aktywności sejsmicznej. Podstawą do analiz była trójnawowa hala przemysłowa o konstrukcji stalowej. Przeprowadzono obliczenia numeryczne metodą elementów skończonych (MES), wykorzystując w analizie dynamicznej metodę spektrum odpowiedzi. Obliczenia przeprowadzono wariantowo, stosując wzorcowe przyspieszeniowe spektra odpowiedzi według Eurokodu 8 oraz te, wyznaczone dla obszaru Górnośląskiego Zagłębia Węglowego (GZW) i Legnicko-Głogowskiego Okręgu Miedziowego (LGOM). Stosując autorską procedurę oceny odporności dynamicznej, dla każdego analizowanego wymuszenia porównano reakcję konstrukcji na wzbudzenie dynamiczne z efektami od kombinacji obciążeń przyjętych na etapie projektowania, ustalając tym samym wartości graniczne projektowego przyspieszenia poziomego gruntu αmaxg,H rozumianego jako odporność konstrukcji na wstrząsy. Pozwoliło to na ocenę wpływu warunków sejsmicznych z określonego obszaru na odporność dynamiczną badanego obiektu. W artykule przedstawiono sposób interpretacji zaproponowanej procedury i wskazano potencjalne możliwości jej zastosowania.
Źródło:
Archives of Civil Engineering; 2020, 66, 4; 525-542
1230-2945
Pojawia się w:
Archives of Civil Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-5 z 5

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies