Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "gas absorption" wg kryterium: Temat


Wyświetlanie 1-12 z 12
Tytuł:
Gamma-ray computed tomography SCANNERS for applications in multiphase system COLUMNs
Autorzy:
Calvo, W. A. P.
Hamada, M. M.
Sprenger, F. E.
Vasquez, P. A. S.
Rela, P. R.
Martins, J. F. T.
de Matos Pereira, J. C. S.
Omi, N.
de Mesquita, C. H.
Powiązania:
https://bibliotekanauki.pl/articles/148082.pdf
Data publikacji:
2009
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
industrial computed tomography
multiphase flow systems
non-destructive testing
gas absorption column
industrial process optimization
packed distillation columns
scanning systems
Opis:
Gamma-ray tomography experiments have been carried out to detect spatial patterns in the porosity, in a 0.27 m diameter packed steel column using a first generation computed tomography (CT) system. The CT scanner consists of a NaI(Tl) detector 5.08 cm in diameter, and an encapsulated 137Cs (3.7 GBq) radioactive source, located opposite to the center of the detector. The detector and the source, mounted on a fixed support and the column, can rotated and dislocate by two stepping motors controlled through a microprocessor. Different sizes of stainless steel Raschig rings (12.6, 37.9 and 76 mm) have been examined. The primary objective of this work is to detect spatial patterns and statistical information on porosity variation in packed distillation columns. Horizontal scans, at different vertical positions of the packed bed were made for each size of Raschig rings. Radial porosity variation within the packed bed has been determined. This study has demonstrated that the porosity and its spatial distribution in a metallic packed column can be measured with adequate spatial resolution using the gamma-ray tomography technique. After validation of this first generation CT, the turntable design to rotate and dislocate the 60Co or 137Cs sealed gamma-ray sources and multidetector array for the third generation industrial computed tomography was also developed.
Źródło:
Nukleonika; 2009, 54, 2; 129-133
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Simultaneous removal of NOx, SO2, CO and Hg from flue gas by ozonation. Pilot plant studies
Autorzy:
Głomba, M.
Kordylewski, W.
Powiązania:
https://bibliotekanauki.pl/articles/950039.pdf
Data publikacji:
2014
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
carbon dioxide
flue gases
ozone
ozonization
pilot plants
sulfur dioxide
gas absorption
NOx removal
So2 removal
CO removal
dwutlenek węgla
tlenki azotu
spaliny
ozon
ozonowanie
instalacje pilotażowe
dwutlenek siarki
absorpcja gazu
usuwanie NOx
usuwanie SO2
usuwanie CO
Opis:
The results of pilot plant investigations of simultaneous removal of NOx, SO2 and Hg from flue gas with ozone as the oxidizing agent and the spray tower absorber with NaOH solution as the absorbent have been presented. Flue gas was delivered into the pilot plant at the flow rate of 200 m3/h from the coal fired OP-430 boiler. The effectiveness of NOx removal was over 95% when the molar ratio O3/NO reached 2.0. Sulfur dioxide was practically completely washed out from flue gas in the absorber at the liquid-to-gas ratio 7.5 dm3/m3. The effectiveness of Hg removal in the studied system was approximately 80%. It was pointed out that CO concentration in flue gas could considerably increase the ozone consumption. The effect of carbon dioxide in flue gas on the chemistry of absorption due to hydroxides conversion into carbonates and bicarbonates was noticed.
Źródło:
Environment Protection Engineering; 2014, 40, 3; 113-125
0324-8828
Pojawia się w:
Environment Protection Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Application of a Gas Sensor Array to Effectiveness Monitoring of Air Contaminated with Toluene Vapors Absorption Process
Autorzy:
Dobrzyniewski, Dominik
Szulczyński, Bartosz
Gębicki, Jacek
Powiązania:
https://bibliotekanauki.pl/articles/2202183.pdf
Data publikacji:
2022
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
gas sensor
sensor array
absorption
deodorization
process control
Opis:
This article demonstrates the application of a gas sensor array to monitor the effectiveness of the absorption process of air stream purification from odorous compounds (toluene vapors). A self-constructed matrix consisting of five commercially available gas sensors was used. Multiple linear regression (MLR) was selected as the statistical technique used to calibrate the matrice. Gas chromatography coupled with a flame ionization detector (GC-FID) was used as a reference analytical technique, which enabled to obtain reliable quantitative determinations of toluene concentration in the samples. A commercially available absorption liquid dedicated to non-polar compounds was used as an absorbent. The process was carried out in two identical systems: in first, pure toluene was absorbed and in the second, toluene vapor contaminated with acetone. This approach allowed verifying the selectivity of the prepared MLR calibration model for process control in the case of the presence of more or less expected pollutants in the treated gas. The results obtained with the gas sensor array were related to the reference technique and they confirm the usefulness and advisability of using these devices to monitor the absorption processes as a cheaper and more time-efficient alternative to chromatographic methods. The root mean square error (RMSE) in absorptivity determination between the results received with the analytical and sensor techniques was 0.019 and 0.041 when treating pure toluene vapors and its vapors with acetone, respectively. Compared to instrumental techniques, sensor matrices are technologically less complex, useful for laboratory purposes, as well as showing application potential for field studies. However, it is necessary to develop more sensitive and selective chemical gas sensor arrays and better master advanced data processing and identification techniques.
Źródło:
Journal of Ecological Engineering; 2022, 23, 10; 269--282
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Experimental study of the membrane contactor systems for gas dehumidification
Autorzy:
Usachov, V.
Laguntsov, N.
Okunev, A.
Teplyakov, V.
Glukhov, S.
Powiązania:
https://bibliotekanauki.pl/articles/346999.pdf
Data publikacji:
2003
Wydawca:
Politechnika Bydgoska im. Jana i Jędrzeja Śniadeckich. Wydział Technologii i Inżynierii Chemicznej
Tematy:
gas/vapour separation
dehumidification
polymeric membranes
membrane absorption
membrane contactor
Opis:
The paper presents a pilot active membrane contactor system (AMCS) description and experimental results for air dehumidification. Triethyleneglycol was used as a hygroscopic liquid carrier. Polydimethylsiloxane based membranes (Lestosil) were used in a spiral wound membrane contactor. The experiments with AMCS demonstrated effective air-drying under a high ratio-feed gas flux/liquid carrier flux (10²-10³). The developed contactor system allows to achieve air dehumidification up to Tdew point= –20 °C.
Źródło:
Ars Separatoria Acta; 2003, 2; 36-46
1731-6340
Pojawia się w:
Ars Separatoria Acta
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Detection of Gaseous Compounds with Different Techniques
Autorzy:
Mikołajczyk, J.
Bielecki, Z.
Stacewicz, T.
Smulko, J.
Wojtas, J.
Szabra, D.
Lentka, Ł.
Prokopiuk, A.
Magryta, P.
Powiązania:
https://bibliotekanauki.pl/articles/220919.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
gas sensors
laser absorption spectroscopy
CEAS
MUPASS
breath analyses
medical screening
Opis:
Sensing technology has been developed for detection of gases in some environmental, industrial, medical, and scientific applications. The main tasks of these works is to enhance performance of gas sensors taking into account their different applicability and scenarios of operation. This paper presents the descriptions, comparison and recent progress in some existing gas sensing technologies. Detailed introduction to optical sensing methods is presented. In a general way, other kinds of various sensors, such as catalytic, thermal conductivity, electrochemical, semiconductor and surface acoustic wave ones, are also presented. Furthermore, this paper focuses on performance of the optical method in detecting biomarkers in the exhaled air. There are discussed some examination results of the constructed devices. The devices operated on the basis of enhanced cavity and wavelength modulation spectroscopies. The experimental data used for analyzing applicability of these different sensing technologies in medical screening. Several suggestions related to future development are also discussed.
Źródło:
Metrology and Measurement Systems; 2016, 23, 2; 205-224
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The use of air-bottoming cycle as a heat source for the carbon dioxide capture installation of a coal-fired power unit
Autorzy:
Chmielniak, T.
Lepszy, S.
Czaja, D.
Powiązania:
https://bibliotekanauki.pl/articles/240691.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
absorpcja chemiczna
cykl powietrza
system gazowo-powietrzny
turbina gazowa
air bottoming cycle
CCS
chemical absorption
gas-air systems
gas turbine
Opis:
The installations of CO2 capture from flue gases using chemical absorption require a supply of large amounts of heat into the system. The most common heating medium is steam extracted from the cycle, which results in a decrease in the power unit efficiency. The use of heat needed for the desorption process from another source could be an option for this configuration. The paper presents an application of gas-air systems for the generation of extra amounts of energy and heat. Gas-air systems, referred to as the air bottoming cycle (ABC), are composed of a gas turbine powered by natural gas, air compressor and air turbine coupled to the system by means of a heat exchanger. Example configurations of gas-air systems are presented. The efficiency and power values, as well as heat fluxes of the systems under consideration are determined. For comparison purposes, the results of modelling a system consisting of a gas turbine and a regenerative exchanger are presented.
Źródło:
Archives of Thermodynamics; 2011, 32, 3; 89-101
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Sensitive detection of acetylene by second derivative spectra with tunable diode laser absorption spectroscopy
Autorzy:
Deng, H.
Sun, J.
Li, P.
Liu, Y.
Yu, B.
Li, J.
Powiązania:
https://bibliotekanauki.pl/articles/174963.pdf
Data publikacji:
2016
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
tunable diode laser absorption spectroscopy
TDLAS
signal processing
Savitzky–Golay filter
trace gas detection
Opis:
A tunable diode laser absorption spectrometer was developed for trace acetylene gas analysis, the system performance was evaluated by combing an appropriate digital signal processing methods, i.e., Savitzky–Golay smoothing and differentiation algorithm. The calculation of the derivative spectra by this method is accompanied by simultaneous data smoothing. Based on the 2nd deriv- ative spectra detection method, the Allan variance technique indicates a C2H2 detection limit of 1.7ppm for 1-s averaging time, and a minimum noise level of 62ppb (parts per billion), at the optimum integration time of ~60s. The calculated 2nd derivative spectra with better resolution, lower detection limits, save signal processing time, and improve the ability to distinguish unresolved spectral signals.
Źródło:
Optica Applicata; 2016, 46, 3; 353-363
0078-5466
1899-7015
Pojawia się w:
Optica Applicata
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Investigations of the materials for carbon monoxide optoelectronic sensors
Badania materiałów do zastosowań w optoelektronicznych czujnikach tlenku węgla
Autorzy:
Sushynskyy, O.
Rudyy, A.
Chapran, M.
Powiązania:
https://bibliotekanauki.pl/articles/408774.pdf
Data publikacji:
2012
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Tematy:
tlenek węgla
ciekły kryształ
czujnik gazu
widmo absorpcyjne
carbon monoxide
liquid crystal
gas sensor
absorption spectrum
Opis:
In this paper, experimental investigations of carbon monoxide (CO) influence on organic materials, namely the plasma of human blood, natural proteins in egg white (albumin) and liquid crystal materials, are presented.
W artykule opisano eksperymentalne badania wpływu tlenku węgla (CO) na wybrane materiały organiczne: osocze ludzkiej krwi i naturalne białko jaj (albuminę), oraz materiały ciekłokrystaliczne.
Źródło:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska; 2012, 1; 18-20
2083-0157
2391-6761
Pojawia się w:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Application of CCHP in deep mine thermal hazard control
Zastosowanie systemu trójgeneracji w systemie kontroli zagrożeń termicznych w kopalni głębinowej
Autorzy:
Yang, D. D.
Wang, B. S.
Zhou, S. G.
Qin, R. X.
Powiązania:
https://bibliotekanauki.pl/articles/348684.pdf
Data publikacji:
2012
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
system trójgeneracji
kopalnia o wysokiej metanowości
kontrola zagrożeń cieplnych
chłodzenie absorpcyjne
CCHP
high gas mine
thermal hazard control
absorption refrigeration
Opis:
Due to the characteristics of high gas, high geothermal temperature and high strength development in Huainan mine area, thermal hazard problem has become more and more serious and also affects safety and productivity in coal mine. The CCHP (combined cooling heating and power), as a new mode to control thermal hazard, is put forward after advantages and disadvantages of all kinds of cooling methods are investigated. The CCHP method not only takes full advantage of gas but also reduces the greenhouse gas emission. At the same time, the application of CCHP remits the pressure of the power supply in summer, providing guarantee for safe and high efficiency exploitation.
W związku z wysoką gazonośnością, wysoką temperaturą pierwotną górotworu i wysokimi wartościami zawartości metanu w kopalni Huainan zaobserwowano zagrożenia natury cieplnej, wpływające również na bezpieczeństwo i wydajność produkcji w kopalni. Po zbadaniu wad i zalet różnych metod klimatyzacji podjęto decyzję o wprowadzeniu systemu trójgeneracji jako nowego sposobu kontroli zagrożeń natury cieplnej. Metoda trójgeneracji nie tylko wykorzystuje pełen potencjał ujętego gazu, ale również pozwala obniżyć emisję gazów cieplarnianych. Zastosowanie tego systemu zmniejsza ponadto pobór energii zasilającej w porze letniej, dając gwarancję bezpiecznej i wydajnej eksploatacji kopalni.
Źródło:
AGH Journal of Mining and Geoengineering; 2012, 36, 3; 443-451
1732-6702
Pojawia się w:
AGH Journal of Mining and Geoengineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Application of quantum cascade lasers to trace gas detection
Autorzy:
Bielecki, Z.
Stacewicz, T.
Wojtas, J.
Mikołajczyk, J.
Powiązania:
https://bibliotekanauki.pl/articles/201703.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
absorption spectroscopy
biomarkers
sensors
gas sensors
cavity enhanced spectroscopy
photoacoustic spectroscopy
spektroskopia absorpcyjna
biomarkery
czujniki gazu
spektroskopia wzmocniona
spektroskopia fotoakustyczna
Opis:
The potential of Quantum Cascade Laser technology has been recently harnessed in industry, medicine and military to create a range of original infrared gas sensors. These sensors have opened up many new applications due to compact size, excellent sensitivity, robust construction and low power requirements. They rely on infrared absorption spectroscopy to determine identity and quantity of gases. The measurement of these gases has relied on different technologies including multi-pass spectroscopy, photoacoustic spectroscopy, cavity ring down spectroscopy, and their various modifications. In this review paper some technologies are described in terms of its advantages/disadvantages in many application. The results of own works about methane, ammonia, nitric oxide, nitrous oxide, and carbonyl sulfide detection are presented as well.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2015, 63, 2; 515-525
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Automatic control of concentration of flue gases
Automatyczna kontrola stężenia gazów spalinowych
Autorzy:
Kucheruk, V.
Kurtynik, I. P.
Dudatiev, I.
Powiązania:
https://bibliotekanauki.pl/articles/152729.pdf
Data publikacji:
2013
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
boiler installation
optic-absorption infrared method
control system
flue gas
frequency regular
controller
algorithm
kotłownia
metoda optyczno-absorbcyjna infraczerwona
system kontroli
gaz dymowy
falownik
kontroler
algorytm
Opis:
Functional scheme of control subsystem of flue gas content by means of optic – absorption infrared method, compensating the impact of atmospheric dust and excess humidity is developed on the basis of boiler unit control system. Automatic control system provides high energy resources efficiency of boiler unit operation.
Wykorzystując układ sterowania kotłownią, został opracowany funkcjonalny schemat systemu kontroli składu gazów dymowych na podstawie metody optyczno-absorbcyjnej infraczerwonej z kompensacją wpływu pyłu atmosferycznego i nadmiernej wilgotności. Fizyczne zasady działania tego systemu polegają na tym, że mierzy się pochłanianie optyczne wypromieniowanego gazu. Pod wpływem światła, które przechodzi przez gazowa kuwetę, molekuły gazu pochłaniając kwanty promieniowania pewnych częstotliwości, wzbudzają się. W zależności od składu gazu dymowego, infraczerwone widma pochłaniania molekuł (gazowej mieszanki) mają indywidualny charakter, który pozwala identyfikować konkretny gaz. System zawiera blok stabilizacji wejściowych parametrów, przetwornik pomiarowy, bloki przetwarzania i wizualizacji informacji. Dla obróbki informacji służy mikrokontroler firmy VIPA serii System 200 V; dla konfiguracji wykorzystali programowy pakiet WINPLC7, język programowania – Lauder Diagram. Zaproponowana technologia umożliwia wysoką wydajność energetyczną kotłowni.
Źródło:
Pomiary Automatyka Kontrola; 2013, R. 59, nr 7, 7; 621-623
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The complementary structural studies of the double metal cyanide type catalysts for the ring opening polymerization of the oxiranes
Komplementarne badania strukturalne dimetalocyjankowych katalizatorów polimeryzacji z otwarciem pierścienia oksiranowego
Autorzy:
Chruściel, A.
Hreczuch, W.
Czaja, K.
Ławniczak-Jabłońska, K.
Janik, J.
Powiązania:
https://bibliotekanauki.pl/articles/947469.pdf
Data publikacji:
2016
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Chemii Przemysłowej
Tematy:
double metal cyanide catalysts (DMC)
thermal analysis
thermogravimetric analysis (TG)
differential scanning calorimetry (DSC)
evolved gas analysis (EGA)
X-ray absorption spectroscopy (XAS)
X-ray absorption near edge structure (XANES)
extended X-ray absorption fine structure (EXAFS)
katalizatory dimetalocyjankowe (DMC)
analiza termiczna
analiza termograwimetryczna (TGA)
różnicowa kalorymetria skaningowa (DSC)
analiza wydzielanych gazów (EGA)
rentgenowska absorpcyjna spektroskopia struktury przykrawędziowej (XANES)
synchrotronowa absorpcyjna spektroskopia rentgenowska (EXAFS)
Opis:
The extensive complementary experimental studies of the double metal catalysts (DMC) with two kinds of the organic ligands were performed. The chemical justification of the observed TG/DSC (thermogravimetric analysis/differential scanning calorimetry) steps was proposed. Several organic ligand complexing states were found in both types of catalysts. X-ray absorption spectroscopy (XAS) analysis established that only Zn atoms are the active metallic centers in DMC catalyst regardless the used ligand. Cl atoms were detected near some of Zn atoms. Contrary to the common suppositions no significant amount of oxygen atoms was detected in the closest coordination spheres of Zn.
Przeprowadzono badania strukturalne katalizatorów dimetalocyjankowych (DMC) z dwoma rodzajami ligandów organicznych. Zaproponowano wyjaśnienie etapów przebiegu krzywych otrzymanych metodą analizy termograwimetrycznej i różnicowej kalorymetrii skaningowej (TG/DSC) badanych katalizatorów. Wykazano obecność kilku stopni związania ligandów w kompleksach DMC. Na podstawie wyników badań z wykorzystaniem absorpcji rentgenowskiej (XAS) stwierdzono, że centrum aktywne katalizatora stanowi atom cynku. W bezpośrednim sąsiedztwie atomów Zn wykryto obecność atomów Cl, natomiast w najbliższych sferach koordynacyjnych atomu Zn nie wykryto atomów tlenu.
Źródło:
Polimery; 2016, 61, 6; 421-432
0032-2725
Pojawia się w:
Polimery
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-12 z 12

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies