Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "flushing" wg kryterium: Temat


Wyświetlanie 1-6 z 6
Tytuł:
The influence of the flushing method on the stable oxygen content in the scr1 crabe breathing loop in the decompression phase
Autorzy:
Woźniak, Arkadiusz
Powiązania:
https://bibliotekanauki.pl/articles/1375136.pdf
Data publikacji:
2020
Wydawca:
Polskie Towarzystwo Medycyny i Techniki Hiperbarycznej
Tematy:
diving apparatus
breathing gas for hyperbaric purposes
flushing process
diving technology
Opis:
Maintaining a stable oxygen content in the breathing loop of the diving apparatus with a semi-closed respiratory circuit is essential for the safety of underwater mine clearance operations. This article discusses the influence of modified methods of flushing the breathing apparatus on the quality of the breathing loop ventilation process. The problem of flushing an apparatus is presented in light of the Polish Naval Academy's change from statistical to deterministic decompression schedules, based on the model of apparatus ventilation, oxygen toxicity hazard and decompression. The examination and determination utilising the required accuracy of the method used for flushing the breathing loop of the device allowed to assess the stable oxygen content during the decompression phase. The assumptions were verified based on a system for measuring oxygen content in the breathing loop.
Źródło:
Polish Hyperbaric Research; 2020, 1(70); 21-42
1734-7009
2084-0535
Pojawia się w:
Polish Hyperbaric Research
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Flushing water and sediments utilization from selected water treatment station
Uzdatnianie wód popłucznych i utylizacja osadów na stacjach uzdatniania wody
Autorzy:
Hirol, A. M.
Boychuk, S. D.
Girol, A. M.
Hirol, M. M.
Kowalski, D.
Łagód, G.
Powiązania:
https://bibliotekanauki.pl/articles/127538.pdf
Data publikacji:
2009
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
water treatment station
flushing water
sediments
stacje uzdatniania wody
wody popłuczne
osady
Opis:
The development of urbanized areas increases the intensity of problems connected to wastes utilization. The products formed during water treatment are usually omitted as irrelevant. These products cover flushing water and sediment. The researches reported in the literature show that pollutant concentration in these products may reach very high values. The effects of their utilization absence may be very significant for the environment. The existing methods of water treatment by-products utilization are still not satisfactory and usually cause significant ecological problems. The problem is not solved by sediments storage, even after its primary dewatering. Sediments combustion, after significant reduction of its volume, may cause increase of the water treatment station functioning costs and also is not commonly accepted by the public. The Authors, basing on the water treatment station in Simferopol, Ukraine, present the method of flushing water treatment and sediments utilization. The proposed technology, based on application of several reagents, enables limitation of water loss. Application of sediments as cement component, in road construction etc. additionally reduces the costs of system functioning. The results of rinsed sewage of Simferopol water treatment station researches are presented as an example of the described problems. The methods of drains treatment and sediments usage in order to break stone chips production are offered and substantiated. The studies are supported by the preliminary economical analysis.
Postępująca urbanizacja prowadzi do nasilenia problemów z utylizacją powstających odpadów. Pośród nich często pomija się jako mało ważne (zdaniem niektórych) produkty powstające w procesie uzdatniania wody. Należą do nich wody i osady popłuczne. Badania dostępne w literaturze wskazują, że koncentracja zanieczyszczeń w tych produktach może być bardzo wysoka. Konsekwencje braku ich utylizacji mogą być bardzo znaczące dla środowiska. Istniejące metody utylizacji produktów ubocznych stacji uzdatniania wody wciąż nie są satysfakcjonujące i często prowadzą do znacznych ekologicznych problemów. Składowanie osadów, nawet po wstępnym ich odwodnieniu, nie rozwiązuje problemu. Spalanie osadów przy znacznym ograniczeniu ich objętości podnosi także znacząco koszty pracy stacji uzdatniania. Nie jest ono tażże powszechnie akceptowalne przez opinię publiczną. Na przykładzie stacji uzdatniania wody w Symferopolu autorzy prezentują metodę uzdatniania wód popłucznych i utylizacji osadów. Zaproponowana technologia, przy zastosowaniu szeregu reagentów, umożliwia ograniczenie strat wody. Zastosowanie osadów jako komponentów do cementu, budowy dróg itp. dodatkowo zmniejsza koszty funkcjonowania stacji uzdatniania. Autorzy prezentują wyniki badań zanieczyszczeń zawartych w wodach popłucznych wybranej stacji uzdatniania, omawiają zastosowany proces technologiczny oraz prezentują wyniki badań jego efektywności. Rozważania uzupełnione zostały o wstępną analizę ekonomiczną.
Źródło:
Proceedings of ECOpole; 2009, 3, 2; 311-316
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of Water Age and Flushing of the Water Supply Network of the Pressure Reduction Zone
Autorzy:
Świętochowska, Martyna
Bartkowska, Izabela
Powiązania:
https://bibliotekanauki.pl/articles/2202171.pdf
Data publikacji:
2022
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
water distribution system
water age
water quality
flushing water system
pressure zone
Opis:
The water of appropriate quality introduced in the water system changes its chemical properties. Depending on the chemical properties of water and pipe materials, various phenomena may occur, e.g. corrosion, and biofilm structure. The decreasing water demand in existing water systems leads to a reduction in the water flow velocity in the pipes. Accordingly, the age of the water in the system increases. It is especially visible at connections and long sections of the network. The deteriorating water quality along with the elapsing time of its stay in the pipes makes it necessary to perform appropriate measures, e.g. flushing the network. Water supply services usually perform them intuitively. The choice of flushing sites, times, or flow rates is not measured and verified. The age of the water and the efficiency of flushing can be simulated in computer programs. EPANET provides tools for such simulations. The research aimed to check the effects of flushing the network and the age of water in the pressure reduction zone. This is a case that is particularly prone to the increasing age of water. The research has shown that the network flushing sites used so far contribute to the exchange of water in the main water pipes. The simulations showed the need for the additional flush in new places, and in the tested case, the age of the water in the pipes is as much as the intervals between subsequent rinses.
Źródło:
Journal of Ecological Engineering; 2022, 23, 10; 229--238
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effect of applying flushing fluid on lubricity properties of refrigerant compressor oils
Wpływ środka do czyszczenia układów chłodniczych na właściwości smarowe olejów sprężarkowych
Autorzy:
Górny, K.
Stachowiak, A.
Tyczewski, P.
Zwierzycki, W.
Powiązania:
https://bibliotekanauki.pl/articles/188722.pdf
Data publikacji:
2017
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
oil/refrigerant mixture
lubricity
flushing fluid
mieszanina olej/czynnik chłodniczy
właściwości smarne
środek myjący
Opis:
There has currently been a dynamic return to applying natural refrigerants such as hydrocarbons. They are substances containing neither fluorine nor chlorine, which contribute to the enlargement of the ozone hole and the greenhouse effect. However, hydrocarbons are the substances from the A3 safety group (flammable) and, at present, are mainly used in appliances of low efficiency. The most widely used refrigerant in this category of appliances is R600a (isobutene). While repairing refrigeration appliances, there is often the need to remove the refrigerant and compressor oil from the system. Any impurities in the system are also removed. Should incorrect removal of the used oil from the installation occur, there is the risk that a certain amount of the oil and flushing fluid shall remain in the refrigeration system. The article presents an evaluation of the effect of a flushing fluid for refrigeration systems on lubricity properties of compressor oils. The article also describes the research on the use of R600a, a mineral oil of VG ISO 32 and commercially available FF1 flushing fluid, for refrigeration systems. The evaluation was made on the basis of the sample wear volume in the block-on-ring node under the conditions similar to compressor exploitation following a longer shut-off period. Three different lubricants were compared: a mixture of mineral oil with FF1 flushing fluid for refrigeration systems in the amount 20% by volume, a mixture of mineral oil with FF1 flushing fluid for refrigeration systems in the amount 50% by volume, and a mixture of mineral oil with FF1 flushing fluid for refrigeration systems in the amount 50% by volume with R600a.
Obecnie w chłodnictwie następuje dynamiczny powrót do stosowania naturalnych czynników chłodniczych takich jak węglowodory. Są to substancje niezawierające fluoru i chloru, które przyczyniają się do powiększania dziury ozonowej oraz efektu cieplarnianego. Węglowodory to jednak substancje z grupy bezpieczeństwa A3 (palne) i są obecnie głównie wykorzystywane w urządzeniach o małej wydajności. Najpowszechniej stosowanym czynnikiem chłodniczym w tej grupie urządzeń jest R600a (izobutan). Przy czynnościach naprawczych urządzeń chłodniczych istnieje często potrzeba usunięcia z układu czynnika chłodniczego i oleju sprężarkowego. Usuwa się również wszelakie zanieczyszczenia znajdujące się w instalacji. W tym celu często używa się płynów do płukania instalacji chłodniczej. Przy nieprawidłowym wykonaniu operacji usuwania z instalacji zużytego oleju istnieje niebezpieczeństwo, że pewna ilość tego oleju i środka czyszczącego pozostanie w instalacji chłodniczej. W artykule przedstawiono ocenę wpływu środka do czyszczenia układów chłodniczych na właściwości smarowe olejów sprężarkowych. Przedstawiono badania z wykorzystaniem czynnika chłodniczego R600a, oleju mineralnego z klasy lepkości VG ISO 32 oraz dostępnego w sprzedaży środka do czyszczenia układów chłodniczych FF1. Oceny dokonano na podstawie zużycia objętościowego próbki w węźle rolka–klocek w warunkach zbliżonych do eksploatacji sprężarki po długim okresie wyłączenia. Porównano trzy różne substancje smarne: mieszaninę oleju mineralnego ze środkiem do czyszczenia układów chłodniczych FF1 w ilości 20% objętości, mieszaninę oleju mineralnego ze środkiem do czyszczenia układów chłodniczych FF1 w ilości 50% objętości oraz mieszaninę oleju mineralnego ze środkiem do czyszczenia układów chłodniczych FF1 w ilości 50% objętości wraz z czynnikiem chłodniczym R600a.
Źródło:
Tribologia; 2017, 272, 2; 59-66
0208-7774
Pojawia się w:
Tribologia
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Improving the efficiency of cleaning annular space with a new flushing fluid
Autorzy:
Kremieniewski, M.
Rzepka, M.
Stryczek, S.
Wiśniowski, R.
Powiązania:
https://bibliotekanauki.pl/articles/298916.pdf
Data publikacji:
2018
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
flush fluid
buffer fluid
cementing casing columns
flushing annular space
surface active agents
surfactants
annular space
Opis:
One of the most important conditions to be met when cementing casing columns is obtaining appropriate tightness of the sealed interval, otherwise gas will have to be released from the annular space due to the dangerously high pressure in the upper part of the well. Gas migrating along the well in the annular space can penetrate directly the soil, groundwater or atmosphere. To counteract these unfavorable effects the casing columns are sealed and the annular space filled with appropriate cement slurry. During injection, the slurry displaces mud from the annular space. However mud residue left out in the wellbore walls may cause that the slurry does not bond the rock sufficiently well and consequently gas may flow on the hardened cement slurry/rock/casing contact. This effect can be eliminated by thorough cleaning of the annular space from mud cake with flush fluid, followed by its complete displacement with buffer fluid and cement slurry. Hence it is crucial for the efficiency of cementing to precede this job with thorough cleaning of the annular space with appropriate flush fluids. Laboratory experiments were undertaken to work out a new flush fluid with which the efficiency of removal of filtration cake from the wellbore walls and the cleaning of the annular space will be improved. Tests were performed for a group of agents, which appropriately selected as far as their quantity and quality is concerned, could create bases for a new type of fluid with very good flushing properties. The efficiency of mud cake removal was analyzed in a mud flow simulator. The analysis of the results revealed that the efficiency of removal of the mud cake on the rock surface can be improved by synergic operation of surfactants and surface active agent, when they are used in good concentrations. The influence of the injection volume and duration of contact of the flush fluid with the rock were taken into account as the main emphasis was on how to increase the efficiency of the designed fluid on the near well zone. The works on the new recipe of flush fluid and its efficiency were based on the measurement of adhesiveness of hardened cement slurry and the rock sample, from which mud cake was removed with the use of flush fluid. The analysis of the laboratory results shows that the efficiency of mud cake removal was considerably increased when the presented flush fluid was applied.
Źródło:
AGH Drilling, Oil, Gas; 2018, 35, 1; 219-233
2299-4157
2300-7052
Pojawia się w:
AGH Drilling, Oil, Gas
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Influence of the Degree of Filling the Packade with Oil and Flushing the Oil Nitrogen on the Oxidative Stability of Cold-Pressed Rapeseed Oil®
Wpływ stopnia napełniania opakowania olejem i płukania oleju azotem na stabilność oksydacyjną oleju rzepakowego tłoczonego na zimno®
Autorzy:
Wroniak, Małgorzata
Hilal, Adonis
Ratusz, Katarzyna
Powiązania:
https://bibliotekanauki.pl/articles/2051345.pdf
Data publikacji:
2021
Wydawca:
Wyższa Szkoła Menedżerska w Warszawie
Tematy:
cold-pressed rapeseed oil
flushing nitrogen
storage
oxidative stability
łoczony na zimno olej rzepakowy
przepłukiwanie azotem
przechowywanie
stabilność oksydacyjna
Opis:
The paper discusses the effect of filling the package with oil, as well as oil nitrogen flushing, on the oxidative stability of cold pressed rapeseed oil during storage in an accelerated test at 3°C, and a long-term test at 20°C. Filling the package with minimal headspace, along with nitrogen flushing the cold pressed rapeseed oil before sealing it, was a very effective way of reducing oxidation damage. Although the formation of peroxides was inhibited, the content of secondary oxidation products increased, and the oxidative stability in the Rancimat test decreased due to peroxide decomposition.
W pracy określono wpływ stopnia wypełnienia opakowania olejem oraz przepłukiwania oleju rzepakowego tłoczonego na zimno azotem na stabilność oksydacyjną w czasie przechowywania w teście przyspieszonym w 63°C i długoterminowym w 20°C. Napełnienie opakowania z minimalną wolną przestrzenią nad olejem jak również przepłukiwanie azotem oleju rzepakowego tłoczonego na zimno przed zamknięciem opakowania, było bardzo efektywnym sposobem ograniczenia zmian spowodowanych utlenianiem. Zahamowane zostało powstawanie nadtlenków, jednakże w wyniku rozpadu nadtlenków, rosła zawartość wtórnych produktów utlenienia i obniżała się stabilność oksydatywna w teście Rancimat.
Źródło:
Postępy Techniki Przetwórstwa Spożywczego; 2021, 2; 84-90
0867-793X
2719-3691
Pojawia się w:
Postępy Techniki Przetwórstwa Spożywczego
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-6 z 6

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies