Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "fire extinguishing agent" wg kryterium: Temat


Wyświetlanie 1-3 z 3
Tytuł:
Mathematical model of the optimization of fire extinguishing time length in the woodworking enterprises` workshops
Autorzy:
Hulida, E.
Koval, O.
Powiązania:
https://bibliotekanauki.pl/articles/410712.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Oddział w Lublinie PAN
Tematy:
mathematical model
optimization
isolation
fire liquidation
fire extinguishing agent
fire extinguishing equipment
Opis:
On the grounds of an analysis of the existing criteria of decision making during the fire extinguishing organization process the differential criteria is recommended for solving the optimization mathematical models. The mathematical model of the optimization of fire extinguishing time length in the woodworking enterprises` workshops is developed; it is based on the determination of a fire area during the time of its unobstructed development, the amount of the devices for the fire extinguishing agent supply, the amount of the fire and salvage units (hereinafter FSU), equipment and evacuation facilities, the duration of the fire isolation and extinguishing as well as its final liquidation. The Monte Carlo method is used for solving the mathematical optimization model. The solving of the mathematical optimization model is conducted by applying the computer hardware and application program package, written in C++ language.
Źródło:
ECONTECHMOD : An International Quarterly Journal on Economics of Technology and Modelling Processes; 2015, 4, 1; 39-43
2084-5715
Pojawia się w:
ECONTECHMOD : An International Quarterly Journal on Economics of Technology and Modelling Processes
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Interaction of fire-extinguishing agents with flame of diesel bio fuel and its mixtures
Interakcje środków gaśniczych z płomieniem biodiesla i jego mieszankami
Autorzy:
Antonov, Anatolii
Skorobagatko, Taras
Yakovchuk, Roman
Sviatkevych, Oleksandr
Powiązania:
https://bibliotekanauki.pl/articles/136669.pdf
Data publikacji:
2020
Wydawca:
Szkoła Główna Służby Pożarniczej
Tematy:
fire-extinguishing agent
extinguishing
burning
diesel bio fuel
diesel fuel
ester
fat
critical application rate
fire hazard
mixture
środek gaśniczy
gaszenie
spalanie
biodiesel
olej napędowy
tłuszcz
krytyczna prędkość podawania
zagrożenie pożarowe
mieszanka
Opis:
Analytical and experimental data on fire hazard of diesel bio fuel, its mixtures with oilbased diesel fuel, and parameters of processes of their burning and interaction with fire-extinguishing agents. Applicability of the types of fire-extinguishing agents having been used for putting-out of diesel bio fuel was revealed and a number of parameters to describe their efficiency when extinguishing diesel bio fuel were determined. It was revealed that in case of diesel bio fuel content in its mixtures with oil-based diesel fuel up to 30% fire-extinguishing efficiency of foam generated from foam solutions nearly does not differ from that when extinguishing diesel fuel containing no additives.
W artykule przedstawiono dane analityczne i eksperymentalne dotyczące zagrożenia pożarowego biodiesla, jego mieszanek z olejem napędowym, jak również parametry procesu ich spalania i interakcje ze środkami gaśniczymi. Wykazano możliwość zastosowania określonych rodzajów środków gaśniczych przy pożarach biodiesla oraz określono szereg parametrów opisujących ich skuteczność.
Źródło:
Zeszyty Naukowe SGSP / Szkoła Główna Służby Pożarniczej; 2020, 1, 73; 7-24
0239-5223
Pojawia się w:
Zeszyty Naukowe SGSP / Szkoła Główna Służby Pożarniczej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of External Factors on the Strength of Firefighting Hoses Used in Fire Protection Units
Wpływ czynników zewnętrznych na wytrzymałość pożarniczych węży tłocznych stosowanych w jednostkach ochrony przeciwpożarowej
Autorzy:
Dwórska, Karolina
Jurecki, Leszek
Jakubowski, Mateusz
Żurawski, Maksymilian
Pastuszka, Łukasz
Powiązania:
https://bibliotekanauki.pl/articles/35055293.pdf
Data publikacji:
2023
Wydawca:
Centrum Naukowo-Badawcze Ochrony Przeciwpożarowej im. Józefa Tuliszkowskiego
Tematy:
firefighting hose
fire hose strength
adhesion
UV
foam extinguishing agent
pożarniczy wąż tłoczny
wytrzymałość węży pożarniczych
adhezja
pianotwórczy środek gaśniczy
Opis:
Aim: The purpose of this article is to review information on firefighting hoses in terms of their division and the materials used in their production, and to determine if and how external factors affect their strength and durability. Introduction: Firefighting hoses are one of the most important products of technical equipment of Fire Protection Units. Since they are an indispensable element during rescue and firefighting operations, conducting research on the strength of fire hoses is needed and extremely important from the point of view of fire protection. Project and methods: Technological advances in the area of using various types of materials for fire hoses over time have had (and continue to have) a significant impact on the undertaking of rescue and firefighting operations, the speed with which these operations are carried out, as well as their effectiveness. Therefore, at the beginning of the article, a historical outline of the fire hoses used for firefighting in various countries around the world over the years was made. In the following part of the article, the influence of external factors on the adhesive strength of firefighting hoses used in fire protection units in Poland was analysed. The effect of exposure to a 3% foam solution of a fire extinguishing agent on hose tape samples placed in this solution was tested, depending on the time of direct contact of the samples with this agent. The effect of UV exposure (under wetting and drying conditions) on the hose tape samples was also studied, with time intervals of different lengths. Results and conclusions: When testing the exposure of the hose tape samples to UV light (for 90 minutes, at 38 ± 3°C, without water spray, followed by water exposure for 30 minutes, at 50 ± 10% humidity), decreasing trends were observed for the average values of delamination strengths. Tests were also made on a series of samples exposed to a 3% solution of aqueous foam extinguishing agent on the hose tape, both externally and internally. Declining trends were observed for the mean values of adhesive strengths (after 3 and 6 weeks). The impact of factors such as exposure to UV radiation, as well as the impact of the foam extinguishing agent solution negatively affects the hose tape, reducing its strength. The article was prepared on the basis of the authors’ own research results, as well as available sources, both national and foreign, based on the available literature on the raised issues.
Cel: Celem niniejszego artykułu jest przegląd informacji dotyczących pożarniczych węży tłocznych pod względem ich podziału oraz materiałów stosowanych do ich produkcji, a także określenie, czy i w jaki sposób czynniki zewnętrzne wpływają na ich wytrzymałość i trwałość. Wprowadzenie: Węże pożarnicze to jeden z najważniejszych wyrobów technicznego wyposażenia jednostek ochrony przeciwpożarowej. Z uwagi na fakt, że stanowią one niezbędny element podczas działań ratowniczo-gaśniczych, prowadzenie badań w zakresie wytrzymałości węży pożarniczych jest potrzebne i niezwykle istotne z punktu widzenia ochrony przeciwpożarowej. Projekt i metody: Postęp technologiczny w obszarze stosowania różnego rodzaju materiałów do produkcji węży pożarniczych z biegiem czasu miał (i ma nadal) znaczący wpływ na podejmowanie działań ratowniczo-gaśniczych, szybkość prowadzenia tych działań, a także ich skuteczność. Dlatego na początku artykułu dokonano zarysu historycznego pożarniczych węży tłocznych stosowanych do gaszenia pożarów w różnych państwach świata na przestrzeni lat. W dalszej części pracy analizowano wpływ czynników zewnętrznych na wytrzymałość adhezyjną pożarniczych węży tłocznych stosowanych w jednostkach ochrony przeciwpożarowej w Polsce. Sprawdzano wpływ oddziaływania 3-procentowego roztworu pianotwórczego środka gaśniczego na próbki taśmy wężowej, umieszczonych w tym roztworze, w zależności od czasu bezpośredniego kontaktu próbek z tym czynnikiem. Badano również wpływ ekspozycji promieniowania UV (w warunkach zwilżenia i suszenia) na próbki taśmy wężowej, w przedziałach czasowych o różnej długości. Wyniki i wnioski: Podczas badania ekspozycji próbek taśmy wężowej na oddziaływanie promieniowania UV (przez 90 min, w temperaturze 38 ± 3°C, bez zraszania wodą, a następnie działaniu wody przez 30 min, przy wilgotności 50 ± 10%) zaobserwowano tendencje spadkowe w przypadku średnich wartości sił wytrzymałości na rozwarstwienie. Dokonano również badań serii próbek poddanych oddziaływaniu 3-procentowego roztworu wodnego pianotwórczego środka gaśniczego na taśmę wężową, zarówno od zewnątrz, jak i od wewnątrz. Zaobserwowano tendencje spadkowe w przypadku średnich wartości sił wytrzymałości adhezyjnych (po 3 i 6 tygodniach). Czynniki takie jak ekspozycja na promieniowanie UV, a także oddziaływanie roztworu gaśniczego środka pianotwórczego negatywnie wpływają na taśmę wężową, zmniejszając jej wytrzymałość. Artykuł przygotowano na podstawie wyników badań własnych autorów, a także dostępnych źródeł zarówno krajowych, jak i zagranicznych, z wykorzystaniem literatury dotyczącej dotyczącą poruszanych zagadnień.
Źródło:
Safety and Fire Technology; 2023, 62, 2; 150-170
2657-8808
2658-0810
Pojawia się w:
Safety and Fire Technology
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-3 z 3

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies