Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "falownik" wg kryterium: Temat


Tytuł:
Some recent developments in inerter-based devices for vibration mitigation
Autorzy:
Wagg, David J.
Powiązania:
https://bibliotekanauki.pl/articles/27311398.pdf
Data publikacji:
2023
Wydawca:
Polska Akademia Nauk. Czasopisma i Monografie PAN
Tematy:
inerter
vibration
mitigation
damping
falownik
wibracja
łagodzenie
tłumienie
Opis:
Reducing the effect of unwanted vibrations is an important topic in many engineering applications. In this paper we describe some recent developments in the area of passive vibration mitigation. This is based on a new device called the inerter which can be exploited in a range of different contexts. In this paper we consider two recent examples; (i) where a flywheel inerter is combined with a hysteretic damper, and (ii) in which a pivoted bar inerter is developed for a machining application. In both cases, experimental test results show that the devices can outperform existing methods.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2023, 71, 3; art. no. e144617
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of the dead time effect of inverters on the control of sensorless induction motor drives
Autorzy:
Piotuch, R.
Pałka, R.
Powiązania:
https://bibliotekanauki.pl/articles/1372856.pdf
Data publikacji:
2010
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
maszyna asynchroniczna klatkowa
sterowanie bezczujnikowe
falownik napięcia
czas martwy tranzystorów
Opis:
MRAS type flux and speed estimators are very popular in the sensorless induction motor drives. The aim of this article is to analyze the influence of a dead time effect on the work of a classical MRAS structure in a sensorless induction motor drive system. To avoid short circuits in a DC link of a voltage source inverter, there are introduced so called dead times between switching of a complementary power transistors in each leg of the inverter. This causes two harmful effects: loss of fundamental voltage, and low-frequency harmonic distortion. Voltage calculated in the control algorithm differs from the one provided to the stator windings. Calculated voltage is provided to MRAS structure which receives incorrect information on the phase voltage. This leads to improper work of flux reference estimator and also whole control structure. In this paper there are presented the simulation results of influence of a dead time effect on a work of MRAS structure in case of rotor flux linkage and angular speed. Such tests seems to be very important because in extreme cases this effect can lead to instability of a drive system.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2010, 88; 129-133
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Fourier series and wavelet transform applied to stepped waveform synthesis in multilevel convertors
Szereg Fouriera i transformata falkowa zastosowane do syntezy schodkowych przebiegów wyjściowych przekształtników wielopoziomowych
Autorzy:
Iwaszkiewicz, J.
Perz, J.
Powiązania:
https://bibliotekanauki.pl/articles/159944.pdf
Data publikacji:
2006
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Elektrotechniki
Tematy:
falownik wielopoziomowy
przekształtnik wielopoziomowy
przebiegi schodkowe
multilevel converters
stepped waveform synthesis
Opis:
The paper is related to the problem of generating the high quality AC voltage waveforms using multilevel converters. This technique can be applied especially in the distributed power energy systems with renewable DC voltage sources like photovoltaic farms and fuel cells. A novel approach to the synthesis of AC voltage waveforms, applying analytical methods like Fourier transform and Haar wavelets is presented. The analysis of the obtained waveforms is presented as well as examples of chosen parameter optimisation. The comparison of modulation methods and their impact on converter topology is discussed.
W wielu zastosowaniach, takich jak systemy energetyki rozproszonej lub urządzenia zasilania bezprzerwowego, podstawowym wymaganiem jest dostarczanie do odbiorników sinusoidalnego napięcia o częstotliwości 50 Hz, charakteryzującego się niską zawartością harmonicznych. Napięcie dostarczane ze źródeł prądu stałego takich jak akumulatory, systemy fotowoltaiczne czy ogniwa paliwowe jest przetwarzane na napięcie przemienne za pomocą przekształtników energoelektronicznych. Jakość przebiegów generowanych przez te urządzenia, w szczególności zaś współczynnik zawartości wyższych harmonicznych THD (Total Harmonic Distortion), powinny odpowiadać odpowiednim standardom. Typowym rozwiązaniem problemu przekształcania energii elektrycznej jest dwupoziomowy przekształtnik energoelektroniczny (VSI - Voltage Source Inverter), sterowany metodą modulacji szerokości impulsów (PWM - Pulse Width Modulation). Ta metoda kształtowania przebiegów ma dobrze znane niedogodności związane z wysoką częstotliwością przełączeń łączników, takie jak straty mocy w łącznikach półprzewodnikowych oraz potrzeba stosowania dodatkowych filtrów w celu eliminacji z przebiegów wyjściowych składowych wysokiej częstotliwości. Niedogodności te mogą być znacznie zmniejszone przy zastosowaniu przekształtników wielopoziomowych sterowanych metodą modulacji amplitudy. Referat prezentuje nowe metody formowania przebiegów schodkowych falowników wielopoziomowych. Rozdział 1 przedstawia propozycję rozwiązania zagadnienia aproksymacyjnego polegającego na aproksymacji funkcji f(x)=sin(x) za pomocą ciągu funkcji gn(x) opisujących impulsy prostokątne. Parametry tego ciągu określono wykorzystując współczynniki Fouriera szeregu ortogonalnego funkcji gn(x). W rozdziale 2 przeanalizowano spektra harmonicznych przebiegów napięcia schodkowego generowanego w ten sposób i poszukano optymalnego, w sensie minimalnej zawartości wyższych harmonicznych (THD), kształtu takiego przebiegu dla falownika trójpoziomowego. Wykazano, że stosując proponowane metody optymalizacyjne można uzyskać znaczące zmniejszenie współczynnika THD (z 31,09 % do 20,40 %). Rozdział 3 poświęcony został wykorzystaniu nowego narzędzia matematycznego, jakim jest transformata falkowa, do syntezy przebiegów schodkowych. Opisano pierwsze przekształcenie falkowe Haara, a następnie przeanalizowano możliwości wykorzystania dyskretnej odwrotnej transformaty falkowej do syntezy przebiegów przemiennych przekształtników wielopoziomowych.
Źródło:
Prace Instytutu Elektrotechniki; 2006, 229; 59-74
0032-6216
Pojawia się w:
Prace Instytutu Elektrotechniki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Mechatronic system with the control of voltage in permanent magnet synchronous generator
Autorzy:
Tarnapowicz, D.
German-Galkin, S.
Powiązania:
https://bibliotekanauki.pl/articles/27315954.pdf
Data publikacji:
2018
Wydawca:
STE GROUP
Tematy:
PMSG
voltage regulation of PMSG
active inverter
regulacja napięcia PMSG
falownik aktywny
Opis:
In recent years, the use of Permanent Magnet Synchronous Generator (PMSG) in ship power plant system has increased. PMSGs are characterized by better properties than the classic and commonly used synchronous generators. In comparison with classic synchronous generators, PMSGs do not have a voltage regulator, and hence as the load increases, the voltage at the output of the generator decreases. The article presents the use of an active voltage inverter with the task to maintain a constant voltage on the receiver along with the load’s increase. Simulation studies confirming the effectiveness of the proposed method were carried out
Źródło:
New Trends in Production Engineering; 2018, 1, 1; 531-537
2545-2843
Pojawia się w:
New Trends in Production Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of Power Converters on Increasing the Share of Renewable Energy Sources
Wpływ przekształtników energoelektronicznych na wzrost udziału odnawialnych źródeł energii
Autorzy:
Przytuła, K.
Zieliński, D.
Powiązania:
https://bibliotekanauki.pl/articles/396930.pdf
Data publikacji:
2016
Wydawca:
ENERGA
Tematy:
converters
SVM
multi-channel converter
interleaved converter
VOC
falownik
przekształtnik wielokanałowy
THD
Opis:
The article shows various configurations of the topology of grid converters with their control systems, tailored to the needs of the energy market and regulations. Power electronic systems are used for the integration of renewable energy sources with power grids and help to increase the part they play in this network. Of particular note are the multi-channel systems, which form the basis of the modern energy market. They are more efficient and have a higher efficiency than conventional systems. The simulations are performed in the MATLAB/Simulink environment. They consist mainly of an analysis of the high harmonics injected into the grid by converters and analysis of the benefits of implementing the converter with alternating work.
Artykuł przedstawia różne konfiguracje topologii przekształtników sieciowych wraz z systemami sterowania, które są dostosowane do potrzeb rynku energetycznego oraz obowiązujących przepisów. Opisane układy energoelektroniczne stosowane są do integracji źródeł odnawialnych do istniejących sieci elektroenergetycznych i wpływają na wzrost ich udziału w tej sieci. Podkreślone jest znaczenie układów wielokanałowych, które stają się podstawą nowoczesnej energetyki, są wydajniejsze i posiadają wyższą spraw- ność od tradycyjnych układów. Symulacje przeprowadzono w środowisku MATLAB/Simulink. Obejmują one przede wszystkim analizę ilości harmonicznych wprowadzanych do sieci przez przekształtniki oraz analizę korzyści układu przekształtnikowego realizującego pracę naprzemienną.
Źródło:
Acta Energetica; 2016, 1; 125-131
2300-3022
Pojawia się w:
Acta Energetica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The conception of the use of multi-level inverters in the shipping shaft generator systems of high power
Koncepcja wykorzystania falowników wielopoziomowych w układach z okrętową prądnicą wałową dużej mocy
Autorzy:
Tarnapowicz, D.
Powiązania:
https://bibliotekanauki.pl/articles/360407.pdf
Data publikacji:
2010
Wydawca:
Akademia Morska w Szczecinie. Wydawnictwo AMSz
Tematy:
prądnica wałowa
stabilizacja częstotliwości
falownik wielopoziomowy
shaft generator
stability of frequency
multilevel inverter
Opis:
The fundamental problem of using the shaft generators of high power in the shipping systems is bound up with the stability of frequency. Electronic systems used nowadays are based on the thyristor inverters which entails vices of such solutions. The article presents the conception of the use of multi-level inverters built on the basis of fully controllable valves (transistors IGBT).This solution eliminates the defects of thyristor inverters.
Zasadniczy problem stosowania w systemach okrętowych prądnic wałowych dużej mocy związany jest ze stabilizacją częstotliwości. Stosowane obecnie układy energoelektroniczne opierają się na wykorzystaniu falowników tyrystorowych, które implikują wady takich rozwiązań. W artykule przedstawiono koncepcję wykorzystania falowników wielopoziomowych, zbudowanych w oparciu o zawory w pełni sterowalne (tranzystory IGBT), które pozbawione są wad falowników tyrystorowych.
Źródło:
Zeszyty Naukowe Akademii Morskiej w Szczecinie; 2010, 22 (94); 67-70
1733-8670
2392-0378
Pojawia się w:
Zeszyty Naukowe Akademii Morskiej w Szczecinie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Economy and energy analysis in the operation of renewable energy installations – a case study
Autorzy:
Idzikowski, Adam
Cierlicki, Tomasz
Powiązania:
https://bibliotekanauki.pl/articles/1839542.pdf
Data publikacji:
2021
Wydawca:
Stowarzyszenie Menedżerów Jakości i Produkcji
Tematy:
panel fotowoltaiczny
odnawialne źródła energii
falownik
solar panel
renewable sources of energy
inverter
Opis:
In the paper an economic, ecological and energy analysis of a home photovoltaic on grid installation was presented. The increase in ecological awareness of the Polish society contributes to the continuous growth of interest in green energy. However, many people haven’t been aware of the ecological, economic and energy benefits of photovoltaic installations yet, so the following analysis is made. The analysis concerns a photovoltaic installation with a capacity of 3.96 kWp located in Ościęciny near Włocławek. The photovoltaic installation consists of 11 monocrystalline panels with a power of 360 Wp, a 4 KTLM Sofar Solar inverter and other necessary components. The first part presents basic issues related to photovoltaic installations. Parameters related to the proper functioning of the photovoltaic installation were replaced. The analysis of the literature will help to understand the essence of the proper functioning of the photovoltaic installation. In the practical part, an analysis of a selected home photovoltaic installation was carried out. Based on the available data, it has been calculated that the installation will have a payback period of over 9 years. The photovoltaic installation will produce approximately 3 582.61 kWh of electricity and will contribute to the reduction of 70 tons of carbon dioxide during the entire operation.
Źródło:
Production Engineering Archives; 2021, 27, 2; 90-99
2353-5156
2353-7779
Pojawia się w:
Production Engineering Archives
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ground leakage current caused by Common-Mode Voltage of PWM inverter
Prądy upływu doziemnego generowane napięciem wspólnym falownika MSI
Autorzy:
Szymański, Jerzy Ryszard
Żurek-Mortka, Marta
Powiązania:
https://bibliotekanauki.pl/articles/106701.pdf
Data publikacji:
2019
Wydawca:
Uniwersytet Technologiczno-Humanistyczny im. Kazimierza Pułaskiego w Radomiu
Tematy:
common-mode voltage
differential-mode voltage
PWM modulation
three-phase traction voltage inverter
two-level PWM inverter
dwupoziomowy falownik MSI
napięcie różnicowe
napięcie wspólne
modulacja MSI
trójfazowy trakcyjny falownik napięciowy
Opis:
In railway tractive vehicles, three-phase PWM (Pulse Width Modulation) inverters generate parasitic Differential-Mode Voltages (DMV) and Common-Mode Voltages (CMV). Parasitic voltages are a side effect of using the width modulation to shape the phase-to-phase inverter’s voltage. In this article, the authors present a mathematical description of the DM and CM voltages and carry out their spectral analysis. Based on the spectral harmonics analysis, the authors present a method for filtration of harmonics of DM and CM voltages aimed at limiting the capacitance parasitic currents: due to DM voltage – phase-to-phase parasitic current and CM voltage – ground parasitic currents. As the final result of the tests, almost complete elimination of leakage parasitic current form PE shock protection system was achieved.
W kolejowych pojazdach trakcyjnych trójfazowe falowniki MSI (Modulacja Szerokości Impulsów) wytwarzają pasożytnicze napięcia różnicowe (Differential Mode Voltage) i wspólne (Common Mode Voltage). Pasożytnicze napięcia są skutkiem ubocznym stosowania modulacji szerokościowej do kształtowania napięć międzyfazowych falownika. W artykule autorzy przedstawiają opis matematyczny napięć DM oraz CM i przeprowadzają ich analizę widmową. Na podstawie przeprowadzanej analizy autorzy przedstawiają metodę filtracji wybranych harmonicznych napięcia DM i CM dla ograniczania wytwarzanych przez nie prądów pasożytniczych: (DM) - międzyfazowych i (CM) – doziemnych. W wyniku badań osiągnięto prawie całkowitą eliminację pasożytniczego prądu upływu doziemnego z systemu ochrony przeciwporażeniowej PE.
Źródło:
Journal of Civil Engineering and Transport; 2019, 1, 1; 15-25
2658-1698
2658-2120
Pojawia się w:
Journal of Civil Engineering and Transport
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Three-phase voltage outages kompensator with cascaded multilevel converter
Autorzy:
Iwaszkiewicz, J.
Bogusławski, P.
Krahel, A.
Łowiec, E.
Powiązania:
https://bibliotekanauki.pl/articles/141242.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
superkondensator
spadki napięcia
wielopoziomowy falownik
synchronizacja
supercapacitor
voltage dips and sags
multilevel inverter
synchronization
Opis:
The paper presents a laboratory prototype of the three-phase transformer less voltage outages compensator with an energy storage based on high voltage supercapacitors. The system described is able to protect an isolated grid e.g. in industry against short voltage interruptions, dips and sags. An idea of a control method as well as a Digital controller has been presented, too.
Źródło:
Archives of Electrical Engineering; 2012, 61, 3; 325-336
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Flywheel proof mass actuator for active vibration control
Autorzy:
Kras, Aleksander
Gardonio, Paolo
Powiązania:
https://bibliotekanauki.pl/articles/27311402.pdf
Data publikacji:
2023
Wydawca:
Polska Akademia Nauk. Czasopisma i Monografie PAN
Tematy:
inerter
proof mass actuator
velocity feedback
siłownik z masą próbną
sprzężenie zwrotne prędkości
falownik
Opis:
This paper presents the experimental results of a new proof mass actuator for the implementation of velocity feedback control loops to reduce the flexural vibration of a thin plate structure. Classical proof mass actuators are formed by coil–magnet linear motors. These actuators can generate constant force at frequencies above the fundamental resonance frequency of the spring–magnet system, which can be used to efficiently implement point velocity feedback control loops. However, the dynamics of the spring–magnet system limit the stability and control performance of the loops when the actuators are exposed to shocks. The proof mass actuator investigated in this paper includes an additional flywheel element that improves the stability of the velocity feedback loop both by increasing the feedback gain margin and by reducing the fundamental resonance frequency of the actuator. This paper is focused on the stability and control performance of decentralized velocity feedback control loops.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2023, 71, 3; art. no. e144605
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The optimization of the TMDI for efficient mitigation of the vibration
Autorzy:
Mnich, Konrad
Perlikowski, Przemysław
Powiązania:
https://bibliotekanauki.pl/articles/27311383.pdf
Data publikacji:
2023
Wydawca:
Polska Akademia Nauk. Czasopisma i Monografie PAN
Tematy:
tuned mass damper
inerter
optimization
mitigation of vibrations
falownik
optymalizacja
łagodzenie wibracji
tłumik masowy strojony
Opis:
The paper concerns the optimization of a tuned mass damper with inerter (TMDI) based on two strategies, i.e., the minimum amplitude in the resonance peak and minimum area under the frequency response curve. The optimization is based on real, accessible parameters. Both optimization procedures are presented in two steps. In the first one, two parameters of the TMDI are tuned (inertance and damping coefficient), while in the second one, three parameters (mass, inertance, and damping coefficient). We show that both strategies give the optimum sets of parameters and allow the reduction of the amplitude of the damped system.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2023, 71, 3; art. no. e144619
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Optimization of fractional order PI controller using metaheuristics algorithms applied to multilevel inverter for grid connected PV
Autorzy:
Boucheriette, Wafa
Mechgoug, Raihane
Benguesmia, Hani
Powiązania:
https://bibliotekanauki.pl/articles/11541888.pdf
Data publikacji:
2023
Wydawca:
Polska Akademia Nauk. Polskie Towarzystwo Diagnostyki Technicznej PAN
Tematy:
MLI inverter
fractional order PI
meta-heuristic
PSO
ABC
GWO
THD
metaheurystyka
falownik
układ regulacji
Opis:
Due to its multiple advantages in industrial and grid-connected applications, Multi-Level Inverters (MLIs) have increased in popularity in recent years. To improve the efficiency of a grid-connected PV system's integrated multi-level inverter fractional order PI (FOPI) controllers are used to describe the control process. The control system is made up of three control loops based on FOPI controllers: one for controlling the intermediate circuit voltage (Vdc) and the other two for controlling the direct and quadratic currents (Id, Iq) supplied by the multilevel inverter. The proposed controller parameters (Kp, KI, λ) must be selected in order to increase the efficiency of the multi-level inverter while decreasing the total harmonic distortion (THD) of the output current of the inverter as well as voltage. For this we used three meta-heuristic algorithms (PSO, ABC, GWO). The performance of the three controllers PSO-FOPI, ABC-FOPI and GWO-FOPI controller is compared. The findings showed that GWO-FOPI performs better than the other PSO-FOPI and ABC-FOPI in accuracy and total harmonic distortion THD term. The simulation will be conducted using Matlab/Simulink.
Źródło:
Diagnostyka; 2023, 24, 3; art. no. 2023311
1641-6414
2449-5220
Pojawia się w:
Diagnostyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Improved virtual space vector modulation for neutral point voltage oscillation and common-mode voltage reduction in neutral point clamped three-level inverter
Autorzy:
Fang, Junlong
Wang, Guangya
Li, Ran
Liu, Siyuan
Wang, Shuyu
Powiązania:
https://bibliotekanauki.pl/articles/1841339.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
three-level inverter
vector conversion
virtual space vector modulation
falownik trójpoziomowy
konwersja wektorowa
modulacja wektora przestrzeni wirtualnej
Opis:
The neutral point clamped (NPC) three-level inverter is widely used in high-voltage and high-power applications. However, neutral point voltage oscillation (NPVO) and common-mode voltage (CMV) problems exist in the NPC three-level inverter. In this paper, an improved virtual space vector modulation (VSVM) is proposed based on the reconstruction of a virtual small vector and a virtual medium vector. Compared with the traditional VSVM, an improved VSVM can effectively reduce the CMV. On this basis, a vector conversion method is proposed to further reduce the NPVO in the whole range. Simulation results verify the effectiveness and superiority of the improved VSVM.
Źródło:
Archives of Electrical Engineering; 2021, 70, 1; 203-218
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Biomass fuel cell based distributed generation system for Sagar Island
Autorzy:
Kumar, P.
Sikder, P. S.
Pal, N.
Powiązania:
https://bibliotekanauki.pl/articles/200813.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
biomass
fuel cell
distributed generation systems
inverter
cost analysis
biomasa
ogniwo paliwowe
falownik
analiza kosztów
generacja rozproszona
Opis:
Sustainable development of an area is highly dependable on reliable electrical energy supply. Due to the depletion of fossil fuels, and the contamination of the environment due to the generation of energy from primary energy sources, the energy sector is reforming and shifting towards a new era where renewable energy sources will become the primary focus of attention. At present, energy researchers and government organizations are interested in a distributed generation system using local renewable energy sources to electrify the rural areas situated far away from our mainland. Here, a biomass-based power supply system is being analyzed and compared with other potential power supply systems for Sagar Island. Sagar Island is the world’s largest river-based island situated in the Sundarban deltaic complex, where the potential of biomass is huge due to the availability of natural forests, barren coastal areas full of weeds, agricultural by-products, cattle manure and waste materials from other sources. Here, an attempt has been made to provide sustainable electrical energy to the rural areas of the isolated Sagar Island for the sustainable development of the local people. This was done by means of using biomass and a fuel cell based electricity generation system.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2018, 66, 5; 665-674
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Review and comparison of methods for limiting leakage currents in single-phase transformerless PV inverter topologies
Autorzy:
Kołodziejski, Wojciech
Jasielski, Jacek
Kuta, Stanisław W.
Szerszeń, Grzegorz
Machowski, Witold
Powiązania:
https://bibliotekanauki.pl/articles/29521110.pdf
Data publikacji:
2022
Wydawca:
Akademia Tarnowska
Tematy:
Differential Mode (DM) voltage
Common Mode (CM) voltage
grid-tied inverter
leakage current
parasitic capacity
photovoltaic (PV) systems
transformerless inverter
napięcie trybu różnicowego (DM).
napięcie trybu wspólnego (CM).
falownik podłączony do sieci
prąd upływowy
pojemność pasożytnicza
systemy fotowoltaiczne (PV).
falownik beztransformatorowy
Opis:
Transformerless inverters are widely used in different photovoltaic nonisolated ac module applications, mainly in grid-tied photovoltaic (PV) generation systems, due to the benefits of achieving high efficiency over a wide load range, and low cost. Various transformerless inverter topologies have been proposed to meet the safety requirement of low ground leakage currents, such as specified in the VDE-4105 standard and low-output ac-current distortion. Topology modifications of transformerless full bridge inverters are designed to balance and maintain a constant common mode output voltage, thereby eliminating or reducing leakage currents. This article reviews and compares the different methods for limiting leakage currents in known topologies of the full-bridge transformerless inverters, such as: H4, H5, H6, HERIC, and their improvements. The main topologies and strategies used to reduce the leakage current in transformerless schemes are summarized, highlighting advantages and disadvantages and establishing points of comparison with similar topologies. To compare the properties of different medium to high power inverters, PV inverter topologies were implemented using IGBTs and tested with the same components, same simulation parameters in PSPICE to evaluate their performance in terms of energy efficiency and leakage current characteristics. The detailed power stage operating principles, extended PWM modulator, and integrated universal gate driver with galvanic isolation in the transmission path of control signal for all IGBTs of the inverter, as well isolated and floating bias power supply for gate drivers are described.
Źródło:
Science, Technology and Innovation; 2022, 16, 3-4; 1-19
2544-9125
Pojawia się w:
Science, Technology and Innovation
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies