Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "electrochemical impedance spectroscopy" wg kryterium: Temat


Tytuł:
Physicochemical analysis of phosphatidylcholine-ceramide system in bilayer lipid membranes
Autorzy:
Naumowicz, Monika
Petelska, Aneta
Figaszewski, Zbigniew
Powiązania:
https://bibliotekanauki.pl/articles/1040678.pdf
Data publikacji:
2008
Wydawca:
Polskie Towarzystwo Biochemiczne
Tematy:
equilibrium
ceramide
complex formation
electrochemical impedance spectroscopy
phosphatidylcholine
bilayer lipid membrane
Opis:
Electrochemical impedance spectroscopy was used for the study of two-component lipid membranes. Phosphatidylcholine and ceramide were to be investigated, since they play an important biochemical role in cell membranes. The research on biolipid interaction was focused on quantitative description of processes that take part in a bilayer. Assumed models of interaction between amphiphilic molecules and the equilibria that take place there were described by mathematical equations for the studied system. The possibility of complex formation for two-component system forming bilayers was assumed that could explain the deviation from additivity rule. Equilibria were described by mathematical equations that were further verified experimentally. The determined values of parameters (stability constant, molecular area of complex, capacitance and conductance of the lipid membranes formed from molecules and complexes) were used for calculation of model curves. The comparison of model curves and experimental points verified the assumed model.
Źródło:
Acta Biochimica Polonica; 2008, 55, 4; 721-730
0001-527X
Pojawia się w:
Acta Biochimica Polonica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
EIS research of AW - 7020 alloy joints welded by MIG
Autorzy:
Dudzik, K.
Charchalis, A.
Powiązania:
https://bibliotekanauki.pl/articles/248097.pdf
Data publikacji:
2012
Wydawca:
Instytut Techniczny Wojsk Lotniczych
Tematy:
electrochemical impedance spectroscopy (EIS)
aluminium alloys
MIG welding
corrosion
Opis:
The results of corrosion properties research of aluminum alloy AW 7020 (AlZn5Mg1) welded by MIG were presented. In the article the parameters for MIG welding of sheets made of AlZn5Mg1 (7020) alloy was presented. Metallographic analysis of bonds showed a proper structural construction MIG welded 7020 aluminum alloy. EIS measurement was performed in three electrode system in artificial seawater (3.5% NaCl). Impedance studies were carried out at the corrosion potential. Changed voltage signal amplitude in the range plus or minus 10 mV and frequency range of changes was as follows: 100 kHz - 0.1 Hz. Atlas 0531 EU and IA potentiostat was used for studies. Model in the form of an electrical equivalent circuit replacement was chosen for the test object. The results of electrochemical impedance spectroscopy are presented graphically in the Nyquist charts matched with the theoretical curve to them and in the form of parameters characterizing the corrosion process. Obtained results were statistically analyzed. Much better resistance to electrochemical corrosion was found for the native material then joint welded by MIG of 7020 aluminum alloy. The most important parameter - charge transfer resistance value of a double layer Rct for sample of native material is higher than for the sample welded by MIG. Original value is received results of the corrosion properties of MIG welded AlZn5Mg1 alloy compared with the native material.
Źródło:
Journal of KONES; 2012, 19, 1; 83-88
1231-4005
2354-0133
Pojawia się w:
Journal of KONES
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Electrochemical impedance characteristics of sintered 7075 aluminum alloy under SSRT condition
Charakterystyka spieku stopu aluminium 7075 metodą elektrochemicznej spektroskopii impedancyjnej (EIS) w warunkach próby rozciągania z małą prędkością odkształcenia (SSRT)
Autorzy:
Sunada, S.
Nunomura, N.
Powiązania:
https://bibliotekanauki.pl/articles/357000.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
sintered material
pitting corrosion
electrochemical impedance spectroscopy
materiał spiekany
wżery korozji
elektrochemiczna spektroskopia impedancyjna
Opis:
Powder metallurgy (P/M) process has the advantage of better formability to fabricate complex shape products without machining and welding. And recently this P/M process has been applied to the production of aluminum alloys. The P/M aluminum alloys thus produced also have received considerable interest because of their fine and homogeneous structure. Many papers have been published on the mechanical properties of the aluminum alloys produced by P/M process while there have been few on their corrosion properties from the view point of electrochemistry. In this experiment, therefore, two kinds of 7075 aluminum alloys prepared by the conventional ingot metallurgy (I/M) process and P/M process were used, I/M material is commercially available. and their corrosion behavior were investigated through the electrochemical tests such as potentiodynamic polarization test, slow rate strain tensile (SSRT) test and electrochemical impedance spectroscopy (EIS) measurement under SSRT test in the corrosion solution and the deionized water.
Zaletą procesu metalurgii proszków (P/M) jest lepsza formowalność podczas wytwarzania produktów o złożonym kształcie nie wymagająca późniejszej obróbki mechanicznej i spawania. Ostatnio ten proces stosowano do wytwarzania stopów aluminium. Tak wytworzone stopy aluminium spotkały się z dużym zainteresowaniem ze względu na ich rozdrobnioną i jednorodną strukturę. Opublikowano wiele prac na temat właściwości mechanicznych stopów aluminium wytworzonych metodą metalurgii proszków, ale niewiele jest prac poświęconych ich korozji z punktu widzenia elektrochemii. W przedstawionej pracy badano korozje dwóch rodzajów stopu 7075, przygotowanych poprzez konwencjonalne odlewanie oraz metoda metalurgii proszków. Badania korozyjne wykonano z wykorzystaniem technik elektrochemicznych takich jak: metoda polaryzacji potencjodynamicznej, próby rozciagania z mała predkoscia odkształcenia (SSRT), pomiarów elektrochemicznej spektroskopii impedancyjnej (EIS) podczas próby rozciągania z małą prędkością odkształcenia w roztworze korozyjnym oraz w wodzie dejonizowanej.
Źródło:
Archives of Metallurgy and Materials; 2013, 58, 2; 505-508
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Physicochemical and electrochemical properties of AISI 316L stainless steel used for implants in human urinary system
Ocena własności fizykochemicznych i elektrochemicznych stali AISI 316L stosowanej na implanty w urologii
Autorzy:
Walke, W.
Przondziono, J.
Powiązania:
https://bibliotekanauki.pl/articles/351228.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
AISI 316L stainless steel
electrochemical impedance spectroscopy (EIS)
X-ray photoelectron spectroscopy (XPS)
scanning electron microscopy (SEM)
austenityczna stal nierdzewna AISI 316L
elektrochemiczna spektroskopia impedancyjna EIS
rentgenowska spektroskopia fotoelektronów XPS
skaningowa mikroskopia elektronowa (SEM)
Opis:
The main purpose of this study was to evaluate physicochemical and electrochemical properties of AISI 316L stainless steel with modified surface, used for implants in human urinary system. In order to simulate conditions, which occur in the tissue environment of the urinary system, the test pieces were exposed in a urinary solution at temperature of T=37 ±1ºC, for a period of 30 days. Evaluation of physicochemical properties of biomaterial was made on the basis of surface chemical analysis (XPS). To evaluate the effects which occur on the surface of the examined steel, Electrochemical Impedance Spectroscopy (EIS) method was also employed. Analysis of test results shows favourable influence of the suggested surface treatment of AISI 316L stainless steel. Samples having electrolytically polished and chemically passivated surface featured the best physicochemical and electrochemical characteristics.
Podstawowym kryterium przydatności biomateriału metalowego na implanty urologiczne (stenty urologiczne) jest biokompatybilność. Jest ona w głównej mierze związana z własnościami fizykochemicznymi powierzchni implantu, które powinny być dostosowane do cech środowiska tkanek układu moczowego człowieka. W celu poprawy biokompatybilności stali Cr-Ni-Mo ustalono warunki wytwarzania warstw pasywnych na jej powierzchni. Wytworzenie warstwy pasywnej obejmowało etap polerowania elektrolitycznego i pasywowania. Taki sposób obróbki powierzchniowej zapewnił chropowatość Ra < 0,16 μm wymaganą dla tego rodzaju implantów. W pracy tej szczególną uwagę skoncentrowano na analizie długotrwałego oddziaływania środowiska sztucznego moczu na własności fizykochemiczne wytypowanej stali. Zasadniczym celem pracy była ocena własnosci fizykochemicznych i elektrochemicznych stali AISI 316L o modyfikowanej powierzchni stosowanej na implanty w układzie moczowym człowieka. W celu zasymulowania warunków występujących w środowisku tkankowym układu moczowego próbki poddawano ekspozycji w roztworze sztucznego moczu o temperaturze T=37±1ºC przez okres 30 dni. O przydatności zaproponowanej warstwy pasywnej do uszlachetniania powierzchni stali w znacznym stopniu decyduje jej skład chemiczny. Dlatego w pracy wykonano badania składu chemicznego metodą spektroskopii fotoelektronów (XPS), z użyciem wielofunkcyjnego spektrometru elektronów PHI 5700/660 firmy Physical Electronics, podczas których zidentyfikowano i wyznaczono stężenia atomowe pierwiastków w badanych warstwach pasywnych. Dla próbek przeprowadzono pomiar widma fotoelektronów w szerokim zakresie energii wiązania od 0÷1400 eV oraz dokładne pomiary linii widmowych poszczególnych pierwiastków składowych z warstwy powierzchniowej. Dla oceny zjawisk zachodzacych na powierzchni badanej stali zastosowano również metodę elektrochemicznej spektroskopii impedancyjnej (EIS). Pomiary przeprowadzono z wykorzystaniem systemu pomiarowego AutoLab PGSTAT 302N wyposażonego w moduł FRA2 (Frequency Response Analyser). Badania przeprowadzono w alternatywnym roztworze symulującym środowisko moczu człowieka. Zastosowana w pracy mikroskopia skaningowa pozwoliła na ocene stanu powierzchni stali AISI 316L przed i po ekspozycji w sztucznym moczu. Analiza wyników badań wskazuje na korzystny wpływ zaproponowanej obróbki powierzchniowej stali AISI 316L. Najkorzystniejszą charakterystykę fizykochemiczną i elektrochemiczną miały próbki o powierzchni polerowanej elektrolitycznie i pasywowanej chemicznie. Przeprowadzone w pracy badania stanowią podstawę do dalszych analiz związanych z zagadnieniem biokompatybilności stali Cr-Ni-Mo stosowanej na implanty w urologii.
Źródło:
Archives of Metallurgy and Materials; 2013, 58, 2; 625-630
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Corrosive properties distribution in AW-7020 alloy joints welded by FSW
Autorzy:
Dudzik, K.
Powiązania:
https://bibliotekanauki.pl/articles/247352.pdf
Data publikacji:
2014
Wydawca:
Instytut Techniczny Wojsk Lotniczych
Tematy:
electrochemical impedance spectroscopy
EIS
friction stir welding
FSW
welding
corrosion
Opis:
The results of corrosion properties research of aluminum alloy AW 7020 (AlZn5Mg1) welded by Friction Stir Welding were presented. In the article the parameters for friction stir welding of sheets made of AlZn5Mg1 (7020) alloy were presented. Corrosion tests were performed on the surface of the FSW joined sheets depending on the distance from the centre of the weld. EIS measurement was performed in three-electrode system in an artificial seawater (3.5% NaCl). Impedance studies were carried out at the corrosion potential. Changed voltage signal amplitude in the range ± 10 mV and frequency range of changes was as follows: 100 kHz - 0.1 Hz. Atlas 0531 EU & IA potentiostat was used for studies. Model in the form of an electrical equivalent circuit replacement was chosen for the test object. The results of electrochemical impedance spectroscopy are presented graphically in the Nyquist charts matched with the theoretical curve to them and in the form of parameters characterizing the corrosion process. Obtained results were statistically analysed. Better resistance to electrochemical corrosion was found for the native material then joint welded by FSW of 7020 aluminum alloy. Worse corrosion properties were observed in the advancing side of the weld than in the retreating side of the weld. Original value are received results of the corrosion properties distribution of FSW welded AW-7020 aluminium alloy.
Źródło:
Journal of KONES; 2014, 21, 4; 79-85
1231-4005
2354-0133
Pojawia się w:
Journal of KONES
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ethanol oxidation reaction at Pd-modified nickel foam obtained by PVD method
Autorzy:
Mikołajczyk, T.
Turemko, M.
Pierożyński, B.
Powiązania:
https://bibliotekanauki.pl/articles/949482.pdf
Data publikacji:
2015
Wydawca:
Zachodniopomorski Uniwersytet Technologiczny w Szczecinie. Wydawnictwo Uczelniane ZUT w Szczecinie
Tematy:
PVD
nickel foam
electrochemical impedance spectroscopy
Opis:
In this study, palladium-modified nickel foam substrate was applied to examine ethanol oxidation reaction (EOR) in 0.1 M NaOH supporting solution. An EOR catalyst was prepared by physical vapour deposition (PVD) of palladium onto Ni foam material. Temperature-dependent kinetics of the EOR were studied over the temperature range: 20-60°C by means of a.c. impedance spectroscopy and cyclic voltammetry techniques. Deposition of a noble metal additive was clearly exposed through scanning electron microscopy: SEM/EDX-supported analysis. Most importantly, this work investigated the effect of pre-deposited fullerene on nickel foam, on the catalytic (EOR) properties of such-produced Ni foam/Pd composite material.
Źródło:
Polish Journal of Chemical Technology; 2015, 17, 2; 47-50
1509-8117
1899-4741
Pojawia się w:
Polish Journal of Chemical Technology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Kinetics of electrooxidation of phenol on polycrystalline platinum
Autorzy:
Pierożyński, B.
Piotrowska, G.
Mikołajczyk, T.
Powiązania:
https://bibliotekanauki.pl/articles/779691.pdf
Data publikacji:
2015
Wydawca:
Zachodniopomorski Uniwersytet Technologiczny w Szczecinie. Wydawnictwo Uczelniane ZUT w Szczecinie
Tematy:
Phenol electrooxidation
PhER
polycrystalline Pt
electrochemical impedance spectroscopy
Opis:
This work reports on kinetics of phenol electrooxidation reaction (PhER), examined at polycrystalline Pt electrode in 0.5 M H2SO4 and 0.1 M NaOH supporting solutions. Important aspects of PhER kinetics were analysed based on potential-dependent, a.c. impedance-derived values of charge-transfer resistance and capacitance parameters. Special attention was also given to the influence of supporting electrolyte ions on the process of phenol oxidation (pH dependence of the PhER), in relation to an important role of anion adsorption on the Pt catalyst surface.
Źródło:
Polish Journal of Chemical Technology; 2015, 17, 2; 126-130
1509-8117
1899-4741
Pojawia się w:
Polish Journal of Chemical Technology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Structural and Electrical Properties of the Selected Rare-Earth Oxychlorides
Strukturalne i elektryczne własności wybranych tlenochlorków metali ziem rzadkich
Autorzy:
Dziubaniuk, M.
Wyrwa, J.
Bućko, M.
Rękas, M.
Powiązania:
https://bibliotekanauki.pl/articles/354326.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
solid electrolytes
electrochemical impedance spectroscopy
rare-earth oxychlorides
stałe elektrolity
elektrochemiczna spektroskopia impedancyjna
tlenochlorki ziem rzadkich
Opis:
The preparation and sintering conditions of the selected rare-earth oxychlorides REOCl (Re=La, Nd, Sm, Gd) were determined. The purity of materials phase compositions was confirmed by X-ray diffraction method. Further analysis of the data enabled lattice parameters and average grain size determination. The electrical properties of the single phase REOCl materials were investigated by Electrochemical Impedance Spectroscopy in wide temperature range in atmospheric air. The spectra were analyzed by the equivalent circuit fitting. Basing on the values of equivalent circuits parameters the specific conductivities were calculated and presented in the Arrhenius coordinates. Energies of activation were calculated. The determined structural and electrical properties of four different rare-earth oxychlorides were directly compared.
Ustalono warunki syntezy i spiekania wybranych tlenochlorków metali ziem rzadkich, a mianowicie LaOCl, NdOCl, SmOCl oraz GdOCl. Czystość składów fazowych materiałów potwierdzono metodą dyfrakcji promieniowania rentgenowskiego. Analiza uzyskanych danych pozwoliła na wyznaczenie wartości stałych sieciowych oraz średniej wielkości ziaren. Własności elektryczne materiałów wyznaczono metodą elektrochemicznej spektroskopii impedancyjnej w szerokim zakresie temperatur w powietrzu atmosferycznym. Do każdego z widm dopasowano układ zastępczy. Na tej podstawie wyznaczono wartości przewodnictw właściwych i sporządzono wykresy Arrheniusa oraz wyznaczono wartości energii aktywacji. Przeprowadzone badania pozwoliły na bezpośrednie porównanie własności strukturalnych i elektrycznych tlenochlorków czterech różnych metali ziem rzadkich.
Źródło:
Archives of Metallurgy and Materials; 2015, 60, 3A; 1595-1601
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Influence of Passivation Type on Corrosion Resistance of Ti15Mo Alloy in Simulated Body Fluids
Wpływ rodzaju pasywacji powierzchni stopu Ti15Mo na jego odporność korozyjną w środowisku płynów ustrojowych
Autorzy:
Szklarska, M.
Dercz, G.
Rak, J.
Łosiewicz, B.
Simka, W.
Powiązania:
https://bibliotekanauki.pl/articles/353709.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
biomaterial
electrochemical impedance spectroscopy
corrosion resistance
passivation
titanium alloys
biomateriały
elektrochemiczna spektroskopia impedancyjna
odporność na korozję
pasywacja
stopy tytanu
Opis:
This work reports on determination of the influence of passivation type of Ti15wt.%Mo implant alloy surface on its corrosion resistance in simulated body fluids. The alloy under investigation was subjected to natural self-passivation in air, and forced passivation by autoclaving in steam, boiling in 30 % solution of H2O2, and electrochemical passivation in 0.9 % NaCl solution. Resistance of the passivated Ti15Mo alloy to pitting corrosion was studied at 37ºC in 0.9 % NaCl solution using open circuit potential method, anodic polarization curves, and electrochemical impedance spectroscopy (EIS). Comparative estimation of the determined parameters of corrosion resistance revealed that the obtained passive layers improve anticorrosive properties of the tested alloy. Surface of the alloy subjected to passivation in steam autoclave reveals the highest protection against pitting corrosion. Anodic potentiodynamic curves showed that the Ti15Mo alloy after different passivation types of the surface is characterized by a lack of susceptibility to pitting corrosion up to potential of 9 V. Based on the EIS investigations, the thickness of the formed oxide layers (TiO2, anatase) was determined to be in the range from 2.0 to 7.8 nm in dependence on the applied type of passivation. It was ascertained that electrochemical properties of the Ti15Mo alloy and possibility of its surface passivation using simple methods, make it an attractive material for use in biomedicine for long-term implants.
Praca dotyczy określenia wpływu rodzaju pasywacji powierzchni stopu Ti15%wag.Mo na jego odporność korozyjną w środowisku płynów ustrojowych. Badany stop poddano naturalnej samopasywacji w powietrzu oraz wymuszonej pasywacji w autoklawie parowym, w gotującym się 30 % roztworze H2O2 oraz elektrochemicznej pasywacji w 0,9 % roztworze NaCl. Odporność pasywowanego stopu Ti15Mo na korozję wżerową badano w temperaturze 37°C w roztworze 0,9 % NaCl metodą potencjału obwodu otwartego, krzywych polaryzacji anodowej oraz elektrochemicznej spektroskopii impedancyjnej (ESI). Ocena porównawcza wyznaczonych parametrów odporności korozyjnej wykazała, że wytworzone warstwy pasywne poprawiają właściwości antykorozyjne badanego stopu. Powierzchnia stopu poddana pasywacji w autoklawie parowym wykazuje najwyższą ochronę przed korozją wżerową. Anodowe krzywe potencjodynamiczne ujawniły, że stop Ti15Mo poddany różnym sposobom pasywacji powierzchni wykazuje brak podatności na korozję wżerową aż do potencjału wynoszącego 9 V. W oparciu o badania ESI wyznaczona została grubość otrzymanych warstw tlenkowych (TiO2, anataz), która w zależności od zastosowanego sposobu pasywacji mieściła się w zakresie od 2,0 do 7,8 nm. Stwierdzono, że właściwości elektrochemiczne stopu Ti15Mo oraz możliwość pasywowania jego powierzchni prostymi metodami, czynią go atrakcyjnym materiałem do zastosowań w biomedycynie na implanty długoterminowe.
Źródło:
Archives of Metallurgy and Materials; 2015, 60, 4; 2687-2694
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ba0.5Sr0.5Co0.8Fe0.2O3-σ and La0.6Sr0.4Co0.8Fe0.2O3-σ composite cathode for solid oxide fuel cell
Autorzy:
Mosiałek, M.
Kędra, A.
Krzan, M.
Bielańska, E.
Tatko, M.
Powiązania:
https://bibliotekanauki.pl/articles/355878.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
barium strontium cobalt ferrite
lanthanum strontium cobalt ferrite
solid oxide fuel cell
oxygen reduction reaction
electrochemical impedance spectroscopy
Opis:
Composite cathodes contain Ba0.5Sr0.5Co0.8Fe0.2O3-σ and La0.6Sr0.4Co0.8Fe0.2O3-σ were tested in different configuration for achieving cathode of area specific resistance lower than Ba0.5Sr0.5Co0.8Fe0.2O3-σ and La0.6Sr0.4Co0.8Fe0.2O3-σ cathodes. Electrodes were screen printed on samaria-doped ceria electrolyte half-discs and tested in the three electrode setup by the electrochemical impedance spectroscopy. Microstructure was observed by scanning electron microscopy. The lowest area specific resistance 0.46 and 2.77 Ω cm-2 at 700 °C and 600 °C respectively revealed composite cathode contain Ba0.5Sr0.5Co0.8Fe0.2O3-σ and La0.6Sr0.4Co0.8Fe0.2O3-σ in 1:1 weight ratio. The area specific resistance of this cathode is characterized by the lowest activation energy among tested cathodes.
Źródło:
Archives of Metallurgy and Materials; 2016, 61, 3; 1483-1488
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of Friction Stir Welding (FSW) on mechanical and corrosion properties of AW-7020M and AW-7020 alloys
Autorzy:
Dudzik, K.
Jurczak, W.
Powiązania:
https://bibliotekanauki.pl/articles/260119.pdf
Data publikacji:
2016
Wydawca:
Politechnika Gdańska. Wydział Inżynierii Mechanicznej i Okrętownictwa
Tematy:
Al alloys
mechanical properties
electrochemical impedance spectroscopy (EIS)
corrosion
FSW
friction welding
Opis:
Friction welding associated with mixing the weld material (FSW - Friction Stir Welding ) is an alternative to MIG and TIG welding techniques for Al-alloys. This paper presents experimental results obtained from static tension tests on specimens made of AW-7020M and AW-7020 alloys and their joints welded by using FSW method carried out on flat specimens, according to Polish standards : PN-EN ISO 4136:2011 and PN-EN ISO 6892-1:2010. Results of corrosion resistance tests are also presented. The tests were performed by using the electrochemical impedance spectroscopy (EIS). EIS measurement was conducted with the use of three-electrode system in a substitute sea water environment (3,5% NaCl - water solution). The impedance tests were carried out under corrosion potential. Voltage signal amplitude was equal to 10mV, and its frequency range - 100 kHz ÷ 0,1 Hz. Atlas 0531 EU&IA potentiostat was used for the tests. For the tested object an equivalent model was selected in the form of a substitute electric circuit. Results of the impedance spectroscopy tests are presented in the form of parameters which characterize corrosion process, as well as on Nyquist’s graphs together with the best-fit theoretical curve. Analysis of the test results showed that the value of charge transfer resistance through double layer , Rct , for the FSW- welded specimen , was lower than that for the basic material, and that much greater difference was found in the case of AW-7020M alloy. The impedance spectroscopy tests showed that both the FSW-welded joints and basic material of AW-7020M and AW-7020 alloys were characterized by a good resistance against electrochemical corrosion in sea water environment , and that FSW –welded joints revealed a greater corrosion rate. The performed tests and subject-matter literature research indicate that application of FSW method to joining Al-alloys in shipbuilding is rational.
Źródło:
Polish Maritime Research; 2016, 3; 86-90
1233-2585
Pojawia się w:
Polish Maritime Research
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A Fast Method of Identifying Rechargeable Batteries Condition and Defects
Autorzy:
Kuliński, K.
Nowrot, A.
Powiązania:
https://bibliotekanauki.pl/articles/2064967.pdf
Data publikacji:
2018
Wydawca:
STE GROUP
Tematy:
lithium-ion batteries
electrochemical impedance spectroscopy
Opis:
The paper presents fast method of identifying industrial and general use rechargeable batteries condition and defects exemplary lithium-ion cells. The proposed method is based on measuring a internal battery electrical impedance for selected frequency points and the next the results are compare with reference characteristics. Diagnostic process is performed for a few minutes when the battery is charging or discharging. So far used, the most popular methods require controlled charging and discharging cells to determine approximately of their capacity and need a long time of the diagnostic process (about few hours to over a dozen hours). The new method allows the dramatically reduction of measurement time and in effect reduces financial work costs of service. The paper shows a various setup systems with commonly use RLC impedance bridges were used in the research. The analysis of measurements allowed to determine the specific spectral function, which indicates rechargeable battery condition. Moreover, it is also possible to apply the obtain method to another electrochemical cell type.
Źródło:
Multidisciplinary Aspects of Production Engineering; 2018, 1, 1; 301--305
2545-2827
Pojawia się w:
Multidisciplinary Aspects of Production Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Fractional model of the electrochemical capacitor relaxation phenomenon
Autorzy:
Martynyuk, V.
Ortigueira, M. D.
Fedula, M.
Savenko, O.
Powiązania:
https://bibliotekanauki.pl/articles/200913.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
electrochemical capacitor transfer function
impulse response
potential relaxation
electrochemical impedance spectroscopy
odpowiedź impulsowa
elektrochemiczna spektroskopia impedancyjna
relaksacja
kondensatory elektrochemiczne
Opis:
The fractional model of the electrochemical capacitor (EC) relaxation phenomenon is presented herein. The EC relaxation phenomenon occurs when EC impedance measurements are performed after charge or discharge current interruption during potential relaxation. The EC fractional model is obtained based on the fractional order transfer function, obtained in turn by means of fitting the EC impedance data. The inverse Laplace transform is used to obtain the EC impulse response. Meanwhile, the EC charge and discharge simulations are performed using the EC impulse response.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2018, 66, 4; 441-448
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Sustainable use of Natural Resources as Alternative for the Hazardous Corrosion Inhibitor of Mild Steel/Dilute Sulfuric Acid Interface: Weight Loss, EIS, AFM and FTIR Studies
Autorzy:
Tezeghdenti, M.
Etteyeb, N.
Dhouibi, L.
Kanoun, O.
Powiązania:
https://bibliotekanauki.pl/articles/351244.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
Acacia Cyanophylla
inhibition
corrosion
mild steel
electrochemical impedance spectroscopy
adsorption
AFM
Opis:
Point of present exploration was to figure out the anticorrosion activity of Acacia Cyanophylla (Saligna leaves) extract on the corrosion of mild steel in dilute sulfuric acid medium, using weight loss measurements and electrochemical impedance spectroscopy. The result of the study revealed that the extract act as a potent inhibitor on mild steel in acid medium. The increase in inhibitor concentration and immersion time showed a positive effect on inhibition efficiency. EIS exhibited one capacitive loop which indicates that the corrosion reaction is controlled by charge transfer process. The increase of phase shift (n) in presence of (ACLE) lower surface roughness. This change reveals the adsorption of the inhibitor compound on the steel surface. According to the results of weight loss measurements, the adsorption of the extract on the steel surface can be described by the Langmuir isotherm. The inhibition mechanism of (ACLE) molecules involves physical interaction between the inhibitor and metal surface. Additionally, Protective film formation against acid attack was confirmed by FT-IR and AFM techniques.
Źródło:
Archives of Metallurgy and Materials; 2018, 63, 2; 697-707
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effect of Cold Rolling on Electrochemical Impedance Behavior of New β-Type Ti-6Mo-6V-5Cr-3Sn-2.5Zr Alloy
Autorzy:
Song, Hocheol
Zakiyuddin, Ahmad
Kim, Sinhye
Lee, Kwangmin
Powiązania:
https://bibliotekanauki.pl/articles/351262.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
beta-titanium alloy
electrochemical impedance spectroscopy
potentiodynamic polarization
Opis:
In this study, the corrosion properties of Ti-6Mo-6V-5Cr-3Sn-2.5Zr alloy were investigated as a function of the cold rolling ratio and annealing temperature. The annealing treatment was carried out at temperature of 680°C, 730°C, and 780°C. The highest corrosion potential observed in the specimen with a 10% rolling ratio was 179 mV, which was more positive than that of the nonrolled specimen (–0.214 VSSC). The lowest corrosion current density (1.30×10-8 A/cm2) was observed in the non-rolled specimen which suggested that the integrity of its passive oxide layer was superior to that of the cold-rolled specimens. Time-dependent EIS evaluation revealed that the consistency of the passive oxide layer was highly affected by the subjected rolling ratio over time.
Źródło:
Archives of Metallurgy and Materials; 2019, 64, 2; 487-490
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies